MAURY USCG vessel records Sign in
← All vessels

SICHEM CARIBBEAN

SICHEM CARIBBEAN is a 1984 tank ship. The Coast Guard has recorded 45 inspections since 1986, most recently in November 2004, along with 52 deficiencies — 2 with no resolution recorded — and 3 operational controls.

Records from 1986 to 2004. Most recent: inspection, 2 November 2004.

Built
1984
Last inspected
2 November 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8400438 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
229504
Flag
BAHAMAS, THE
—
Maury page id
psix-229504

Inspections, by type

…with no type recorded27
Years with a record 18 calendar years (1986–2004)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6815 - Dead Weight, Ton
9131 - Displacement, Ton
2207 - Convention (Subpart B), Net Ton
4215 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 45

2 November 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2233353
27 September 2004 Enhanced Seaway Inspection (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2203877
29 July 2004 PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2148666
15 July 2004 ISPS II Exam · COC-CHEM Annual · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2134566
14 July 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1859548
19 May 2003 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1797005
19 August 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1663386
11 March 2002 In-Service Inspection · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1492886
4 January 2002 Administrative Inspection
Administrative · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1476417
28 December 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1473684
6 December 2001 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 296021
4 September 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 293035
4 September 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1071385
26 July 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 431110
26 July 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1107156
29 July 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 418715
29 July 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 801902
1 May 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403130
3 April 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 389346
1 February 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 387100
5 July 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 4187
5 July 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 380219
5 July 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1374336
11 October 1994 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 645799
10 October 1994 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 510007
19 March 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 855336
14 March 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 854384
8 January 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355506
29 October 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 354044
29 October 1992 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141231
14 September 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253714
3 April 1990 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 986273
13 July 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 453447
13 July 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 524798
27 October 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 326459
27 October 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 888672
28 January 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 321057
28 January 1988 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1016982
26 January 1988 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 463909
4 January 1988 Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1007511
4 July 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 317127
24 April 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 443069
18 April 1987 MARPOL Annex II Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1327965
15 September 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1004963
13 September 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 311366

Deficiency record · 52

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 15 July 2004 Resolved
MAKE CARGO PUMP ROOM AVAILABLE FOR INPECTION BY THE U.S. COAST GUARD AT NEXT US PORT. THIS REQUIRES A CERTIFIED MARINE CHEMIST TO ATTEND THE VSL.
Action required: 705 - Other - as specified
Resolved 29 July 2004
Resolution: Inspected pumproom. No def. noted.
Accommodation/Occupational Safety › Potable Water System › General
Issued 15 July 2004 No resolution recorded
Stbd side, at xfer manifold, emergency shower not operation. (Could not find correct MISLE entry).
Action required: 705 - Other - as specified
Resolution: FIXED PRIOR TO DEPARTURE.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 15 July 2004 No resolution recorded
#5 stbd CT high level alarm not operational.
Action required: 705 - Other - as specified
Resolution: C/M CORRECTED PRIOR TO MY DEPARTURE
Unknown
Issued 4 September 2001 Resolved
Make permanent repairs to the satisfaction of class to the approximately 12" crack in weldment connecting pumproom vent to the port side mast riser prior to next US port or 06OCT01.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Unknown
Issued 4 September 2001 Resolved
Make permanent repairs to the satisfaction of class to mast riser ladder rungs prior to next US port or 06OCT01
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Lifesaving
Issued 4 September 2001 Resolved
Make repairs to cracks at weldment connecting horizontal bulkhead stiffenerand vertical bulkhead stiffener at forward cargo pump bulkhead approximately 3 feet from the over head - totaling eigth cracks.
Condition: Unknown
Due 6 September 2001
Resolved 16 September 2001
Lifesaving
Issued 4 September 2001 Resolved
Make repairs to the satisfaction of class to doublers at skin valve sea chest/sea water piping in the cargo pump room.
Condition: Unknown
Due 6 October 2001
Resolved 16 September 2001
Engineering › Sea-water System (primary cooling)
Issued 4 September 2001 Resolved
Make repairs to the satisfaction of class to the pumproom sea chest/sea water piping at the five doublers. LEGACY COMPONENT DESC: Sea Chest
Condition: Improper/Lack of Maintenance
Due 30 November 2002
Resolved 30 August 2002
Resolution: Class has faxed report indicating that temp. repairs have been made, permanent repairs to be made at dry dock Nov. 02
Lifesaving
Issued 4 September 2001 Resolved
Renew gooseneck for potable water aft starboard side.
Condition: Unknown
Due 6 September 2001
Resolved 16 September 2001
Lifesaving
Issued 4 September 2001 Resolved
Make repairs to the satisfaction of class to numbers 1 and 3 cargo pump discharge at the connection for the pressure gage sending units where holed.
Condition: Unknown
Due 6 September 2001
Resolved 16 September 2001
Lifesaving
Issued 4 September 2001 Resolved
Make repairs to the satisfaction of class to doubler on discharge side of tank cleaning pump.
Condition: Unknown
Due 6 October 2001
Resolved 16 September 2001
Lifesaving
Issued 4 September 2001 Resolved
Make repairs to tank cleaning suction piping where holed.
Condition: Unknown
Due 6 September 2001
Resolved 16 September 2001
Lifesaving
Issued 4 September 2001 Resolved
Make repairs to ballast pump suction soft patch at the skin valve.
Condition: Unknown
Due 6 September 2001
Resolved 16 September 2001
Lifesaving
Issued 4 September 2001 Resolved
Renew flame screens as needed.
Condition: Unknown
Due 6 September 2001
Resolved 16 September 2001
Documentation
Issued 29 July 1998 Resolved
PROVIDE GAS FREE CERTIFICATE TO EXAMINE PUMP ROOM AND BALLAST TANK AT NEXT_x001C_U.S. PORT IN ACCORDANCE WITH 46 U.S.C. 3714(a)(2).
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Engineering
Issued 29 July 1998 Resolved
PROVIDE EMERGENCY LIGHTERING EQUIPMENT IN ACCORDANCE WITH 33CFR157.410._x001C_ PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Deck/Cargo
Issued 29 July 1998 Resolved
PROVIDE PROOF THAT AVAILABLE HIGH LEVEL ALARM IS OPERATIONAL PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Fire Fighting
Issued 1 February 1996 Resolved
PIPING AT THE BASE OF MONITOR NO.5 WAS HOLED AND TEMPORARY REPAIRED, MUST BE PERMANENTLY REPAIRED PRIOR TO NEXT U.S. PORT AS PER SOLAS 74 CHP. II, REGULATION 21.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Documentation
Issued 1 February 1996 Resolved
OUTSTANDING REQUIREMENTS ISSUED BY CLASS SOCIETY WERE NOT CORRECTED BY REQUIRED DATE. MUST PROVIDE REPORT THAT DEFICIENCIES HAVE BEEN CORRECTED OREXTENDED BY CLASS.
Condition: Unknown
Due 1 February 1996
Resolved 6 February 1996
Lifesaving
Issued 1 February 1996 Resolved
STARBOARD SIDE LIFEBOAT RUDDER COUPLING OUT OF ITS SHAFT. MUST BE REPAIR PRIOR TO DEPARTURE AS PER SOLAS 74 CHAPTER II, REGULATION 21.
Condition: Unknown
Due 1 February 1996
Resolved 6 February 1996
Deck/Cargo
Issued 1 February 1996 Resolved
DO NOT CONDUCT TRANSFERING OPERATIONS UNTIL REQUIREMENT PS01 AND PS02 ARE SATISFIED.
Condition: Unknown
Due 1 February 1996
Resolved 6 February 1996
Documentation
Issued 1 February 1996 Resolved
SAFETY CONSTRUCTION AND SAFETY EQUIPMENT CERTIFICATE WERE EXPIRED. MUST BE PROVIDED BY CLASS SOCIETY AS PER SOLAS 74.
Condition: Unknown
Due 1 February 1996
Resolved 6 February 1996
Electrical
Issued 1 February 1996 Resolved
LIGHTING FIXTURES WERE MISSING LIGHT COVERS IN THE ENGINE ROOM. MUST PROVIDE LIGHT COVERS FOR ALL MISSING FIXTURES PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Documentation
Issued 14 March 1994 Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE AN APPROVED P&A MANUAL THAT HAS BEEN REVIEWED BY EITHER LLOYDS OR BAHAMAS FLAG AUTHORITY.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Deck/Cargo
Issued 14 March 1994 Resolved
AT NEXT U.S. PORT, DEMONSTRATE PROPER OXYGEN METER CALIBRATION IN THE PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Documentation
Issued 14 March 1994 Resolved
PROVIDE MSC-3 WITH UPDATED CERTIFICATE OF FITNESS AND OBTAIN NEW SUBCHAPTERO ENDORSEMENT.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Navigation
Issued 14 March 1994 Resolved
OBTAIN COAST PILOT VOL V PRIOR TO DEPARTURE PORT HOUSTON.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Deck/Cargo
Issued 14 March 1994 Resolved
PRIOR TO NEXT U.S. VOYAGE PROVIDE TWO REQUIRED LEL METERS.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Deck/Cargo
Issued 14 March 1994 Resolved
PRIOR TO NEXT U.S. VOYAGE MAKE PERMANENT REPAIRS TO (ONE) OXYGEN METER.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Deck/Cargo
Issued 14 March 1994 Resolved
PRIOR TO NEXT U.S. VOYAGE MAKE PERMANENT REPAIRS TO THE NUMBER 4 CARGO PIPLINE IN WAY OF THE NUMBER 3 PORT CARGO TANK. PIPING IS HOLED WHERE OLD REPAIR HAS BEEN MADE. THE BAD SECTION OF CARGO PIPING IS TO BE REPLACED BEFORE ANY REGULATED CARGOES CAN BE LOADED.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Documentation
Issued 14 March 1994 Resolved
PRIOR TO NEXT U.S. VOYAGE, UPDATE NLS CARGO AUTHORIZATION PAGES INTO P & A MANUAL.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Fire Fighting
Issued 29 October 1992 Resolved
PRIOR TO ENTERING NEXT U.S. PORT REPLACE BOLTS ON THE FWD AND AFT PORT FIREMONITORS. NEITHER WILL MOVE UP/DOWN.
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Deck/Cargo
Issued 29 October 1992 Resolved
PRIOR TO EENTERING NEXT U.S. PORT REPLACE MISSING BOLTS ON THE #1 SLOP TANKSTBD & PORT.
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Lifesaving
Issued 29 October 1992 Resolved
PRIOR TO DEPARTING PORT OF NEW ORLEANS COVER AND STOW OPEN CANS OF PAINT AND PAINT THINNER IN THE PAINT LOCKER OR INSTALL A CO2 SYSTEM. ALSO FREE ALL DOGS ON THE PORT DOOR TO PAINT LOCKER.
Condition: Unknown
Due 29 October 1992
Resolved 3 December 1992
Deck/Cargo
Issued 29 October 1992 Resolved
PRIOR TO DEPARTING PORT OF NEW ORLEANS REPAIR ALL P/V VALVES.
Condition: Unknown
Due 29 October 1992
Resolved 3 December 1992
Lifesaving
Issued 29 October 1992 Resolved
PRIOR TO ENTERING NEXT U.S. PORT REPAIR EMERGENCY SHOWER AND EYEWASH. IT CANNOT BE OPERATED FROM THE INTENDED KNOB OR HANDLE.
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Deck/Cargo
Issued 29 October 1992 Resolved
PRIOR TO ENTERING NEXT U.S. PORT MARK TANK CONNECTIONS "LIQUID" OR "VAPOR".
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Navigation
Issued 29 October 1992 Resolved
PRIOR TO DEPARTING PORT OF NOLA PROVE THAT THE FOLLOWING CHARTS ARE ONBOARD: 11370; 11368 OR 11367.
Condition: Unknown
Due 29 October 1992
Resolved 3 December 1992
Documentation
Issued 29 October 1992 Resolved
PRIOR TO DEPARTING PORT OF NEW ORLEANS PROVIDE COPIES OF: COFR; LOAD LINE CERTIFICATE; CERTIFICATE OF REGISTRY.
Condition: Unknown
Due 29 October 1992
Resolved 3 December 1992
Engineering
Issued 29 October 1992 Resolved
PRIOR TO ENTERING NEXT U.S. PORT REPLACE FLAME SCREENS ON FUEL OIL VENTS ONTHE PORT SIDE OF HOUSE.
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Fire Fighting
Issued 29 October 1992 Resolved
PRIOR TO ENTERING NEXT U.S. PORT REPAIR HYDRANT ON PORT SIDE OF STERN (HYDRANT WAS LEAKING ON 29OCT92).
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Documentation
Issued 29 October 1992 Resolved
PRIOR TO ENTERING NEXT U.S. PORT PROVIDE PROOF OF ILO MEDICAL EXAMS FOR ALLCREWMEMBERS (ON 29OCT92 THE FOLLOWING WERE MISSING: BALIC; BEMIC; CECIC- VENJIR; MIJOLOVIC; NIZIC; TOMASKOVIC; ZUVELA.
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Fire Fighting
Issued 29 October 1992 Resolved
PRIOR TO ENTERING NEXT U.S. PORT REPAIR/REPLACE #5 HOSE STATION FIRE EQUIPMENT ROOM DOOR AND HINGES.
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Construction/Loadline
Issued 29 October 1992 Resolved
PRIOR TO ENTERING NEXT U.S. PORT REPAIR/REPLACE FAULTY HATCH GASKETS ON HATCH LOCATED ON THE PORT SIDE OF THE PUMP ROOM.
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Fire Fighting
Issued 29 October 1992 Resolved
PRIOR TO ENTERING NEXT U.S. PORT FREE FIRE CONTROL PLAN CONTAINER LOCATED ON PORT SIDE OF HOUSE (COVER IS FROZEN PREVENTING ACCESS).
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Deck/Cargo
Issued 29 October 1992 Resolved
PRIOR TO ENTERING NEXT U.S. PORT MAKE PERMANENT REPAIRS TO THE CARGO PIPINGIN WAY OF THE #3 CARGO TANK PORT SIDE. PIPE CURRENTLY HAS A SOFT PATCH.
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Navigation
Issued 27 October 1988 Resolved
CHART 18720 ONBOARD BUT NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33. NO FOREIGN EQUIVALENTS ONBOARD.
Condition: Unknown
Due 27 October 1988
Resolved 27 October 1988
Navigation
Issued 28 January 1988 Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE U.S.COAST PILOT VOLUME 4 AS REQ BY33 CFR 164.3(A)(2)(I) WAS NOT O/B.
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Deck/Cargo
Issued 15 September 1986 Resolved
PORTABLE CARGO HOSES NOT MARKED IAW 33CFR154.500(E)1-4
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Deck/Cargo
Issued 15 September 1986 Resolved
#2 CARGO PUMP CONTROL GUAGE INOPERATIVE IN CARGO CONTROL ROOM
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Deck/Cargo
Issued 15 September 1986 Resolved
TOXIC GAS DETECTOR, DRAEGER TUBES, EXPIRED
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Navigation
Issued 13 September 1986 Resolved
NOS CHARTS 18720, 18740, 18749, AND 18751 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 13 September 1986
Resolved 13 September 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.