Records from 1984 to 2012. Most recent: operational control imposed, 24 February 2012.
Inspection history · 72
24 February 2012
ISPS III Exam · PI Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4250537
24 February 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4253498
23 February 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4249947
6 February 2012
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4239341
20 January 2012
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4227421
15 December 2011
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4208618
12 December 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4206894
29 December 2010
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3917406
9 December 2010
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3907301
16 November 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3889638
16 November 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3890150
18 March 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3435823
16 March 2009
NPV Safety Exam · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3434568
16 March 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3435767
17 February 2009
ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3419067
27 January 2009
PII Safety Exam · Deficiency Check · ISM Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3395496
15 December 2008
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3379998
10 November 2008
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3360592
3 November 2008
Deficiency Check · PI Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3356371
3 November 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3366189
18 August 2008
ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3301976
27 May 2008
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3219020
25 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3192171
21 April 2008
Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3189378
17 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3186548
14 April 2008
PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3182003
3 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3176973
31 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3175212
18 March 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3167158
5 July 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2984345
3 July 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2699591
26 September 2005
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2501810
21 July 2005
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2434384
11 July 2005
Ballast Water Examination · NPV Safety Exam · ISPS III Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2421249
20 May 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2369873
6 April 2005
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2327864
14 March 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2309951
18 October 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2223146
22 September 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2202313
8 September 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2190645
13 July 2004
PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2130464
14 June 2004
MTSA/ISPS Verification · Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2095323
15 March 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2025118
15 March 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2026640
7 September 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1900052
12 May 2003
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1794981
6 November 2002
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1701846
2 May 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1611120
29 September 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 294385
4 October 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 282687
5 June 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 417228
29 May 1997
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 404027
24 February 1997
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 485318
17 November 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 384915
28 October 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 647615
26 January 1994
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 364146
7 January 1992
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 348077
16 October 1991
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 437064
5 June 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 523862
17 December 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 340952
27 August 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 490773
26 February 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 335536
22 August 1989
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 523970
28 February 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 328756
8 November 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 493456
29 February 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 321704
23 August 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 530935
17 February 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 314369
4 February 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 471018
29 May 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 302254
19 March 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 467655
12 September 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 297961
Engineering › Diesel Engine (propulsion-direct drive) › Piston Ring
Issued 27 February 2012
Resolved
1410 (Propulsion Main Engine) - After any survey of the ship has been completed, no change shall be made in the machinery without sanction of the administration. Due to main engine casualty, special maintenance has been performed, which requires approval from Recognized Organization. Cite: SOLAS74 I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2012
Resolution: NKK Class Surveyor attended M/V VALENCIA CARRIER and attested to proper repairs and working condition of M/E.
Navigation › Piloting/Steering › Gyro Compass
Issued 27 February 2012
Resolved
1540 (Gyro Compass) - The gyro compass shall be subject to initial and subsequent surveys. Vessel's gyro compass is inoperable. Cite: SOLAS74 I/8
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2012
Resolution: Gyro technician attended M/V VALENCIA CARRIER and issued tech-report attesting to the repair and working condition of the vessel''s gyro.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 15 December 2011
Resolved
The normal equipment of every lifeboat shall consist of food rations kept in airtight receptacles. (05) food rations in the port lifeboat are not airtight. SOLAS 74 CH. III/Reg. 11 (9)(xii). Deficiency to be rectified prior to departure to the satisfaction of the CG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2011
Resolution: PSCO witnessed satisfactory starting of motor lifeboat.
Lifesaving › Lifeboat › Propulsion Engine
Issued 15 December 2011
Resolved
A motor lifeboat shall be fitted with a compression engine and kept so as to be at all times ready for use. Motor lifeboat will not start. SOLAS 74 CH. III/Reg 9(a)(i). Deficiency to be rectified prior to departure to the satisfaction of the CG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2011
Resolution: Master showed PSCOs receipt for 05 food rations dated 15DEC2011.
Lifesaving › Launching Appliances › Winch
Issued 16 November 2010
Resolved
SOLAS 74 CH III REG 36
VESSEL'S CREW WAS UNABLE TO DEMONSTRATE PROPER OPERATION OF THE LAUNCHING AND RECOVERY OF THE STARBOARD LIFE BOAT. VESSEL'S PNEUMATIC WINCH WAS UNABLE TO RECOVER THE LIFE BOAT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: crew showed competency in the lowering and recovery of the lifeboat. the recovery winch worked as designed.
Lifesaving › Lifeboat › Propulsion Engine
Issued 16 November 2010
Resolved
SOLAS 74 CH III REG 9(a)(i)
STARBOARD SIDE LIFE BOAT ENGINE FAILED TO START WITHOUT THE USE OF STARTING FLUID.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: lifeboat engine started first try without starting fluid.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 16 November 2010
Resolved
SOLAS 74 CH II-1 REG 23
ALL SHIP SERVICE GENERATORS HAVE EXCESSIVE LUBE AND FUEL OIL LEAKS CREATING A MAJOR FIRE HAZARD IN THE ENGINE ROOM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: oil was cleaned up and general overhual was conducted on generators.
Engineering › Fuel Oil Service System › Piping
Issued 16 November 2010
Resolved
SOLAS 74 CH II-1 REG 23
VESSEL'S EMERGENCY GENERATOR HAS EXCESSIVE FUEL OIL LEAKS CAUSING A MAJOR FIRE HAZARD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: emergency generator operated without fuel oil leaks.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 16 November 2010
Resolved
SOLAS 74 CH II-1 REG 23
THE VESSEL HAS EXCESSIVE EXHAUST LEAKS ON THE #1 SHIP SERVICE GENERATOR RESULTING IN ELEVATED LEVELS OF CARBON MONOXIDE CREATING AN UNSAFE WORKING ENVIRONMENT .
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: ehaust leaks were repaired and generator remains in class.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 16 November 2010
Resolved
MULTIPLE SMOKE DETECTORS IN THE ENGINE ROOM WERE BROKEN OR NOT WORKING PROPERLY, MANY WERE FOUND COVERED WITH PLASTIC BAGS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: all smoke detectors were found to operate as designed.
Engineering › Bilge Water Management System › Not Operational
Issued 16 November 2010
Resolved
SOLAS 74 CH I REG 11
BILGE ALARMS FAILED TO OPERATE PROPERLY AS DESIGNED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: bilge alarms operated as designed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 16 November 2010
Resolved
SOLAS 74 CH II-2 REG 23
MULTIPLE CLASS "A" FIRE DOORS IN THE ENGINE ROOM ARE BROKEN OR NOT WORKING PROPERLY.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: Broken doors and hardware were replaced or repaired and operate as designed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 16 November 2010
Resolved
SOLAS 74 CH1 REG 11
VESSEL WAS FOUND TO HAVE SMOLDERING EMBERS COMING FROM EXHAUST STACK OF THE #1 MAIN GENERATOR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: class inspected and generators were cleaned and operated without producing embers.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 16 November 2010
Resolved
SOLAS 74(2009 CONS) CH IX REG 5, ISM CODE REG 10.2
THE ONLY NON CONFORMITIES FOUND REPORTED TO THE COMPANY WERE PORT STATE CONTROL ISSUED DEFICIENCIES. VESSEL WAS UNABLE TO PROVIDE ANY RESPONSES FROM THE COMPANY.
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: Audit and Training were carried out.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 November 2010
Resolved
SOLAS 74 CH1 REG 11
MULTIPLE HANDRAILS IN THE ENGINE ROOM WERE BROKEN OR REMOVED.
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: new sections of hand rails were welded in. vessel remains within class.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 16 November 2010
Resolved
SOLAS 74 CH II-2 REG 23
MULTIPLE CLASS "A" FIRE DOORS FOR THE GALLEY DO NOT OPERATE PROPERLY AS REQUIRED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: all doors and bulkheads were repaired and operated as designed.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 16 November 2010
Resolved
SOLAS 74 CH II-2 REG 33 (a)(vi)
MULTIPLE SOUNDING TUBES TERMINATING IN THE ENGINE ROOM WERE MISSING SUITABLE MEANS OF CLOSURE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: cleared by PSC and Class. All self closing devices were operating as designed and new caps were ordered and installed.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 16 November 2010
Resolved
MARPOL 2006 ANNEX I CH 2 REG 4.2
VESSEL HAD NON-APPROVED PIPING INSTALLED INTO THE SLUDGE / BILGE/ BALLAST SYSTEM IN THE ENGINE ROOM THAT WAS NOT IN ACCORDANCE WITH THE VESSELS PIPING DIAGRAM. THIS PIPING WAS ADDED TO DRAIN THE EXCESSIVE FUEL AND LUBE OIL LEAKS FROM THE GENERATOR BILGE TO THE SLUDGE TANK.
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: pipeing was inspected by class and flag and was detemined to be unapproved pipeing. pipes were removed.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 16 November 2010
Resolved
SOLAS 74 CH II-2 REG 1(g)(ii)
PROVISIONS COULD NOT BE MADE FOR TESTING THE CORRECT OPERATION OF THE SHIP'S INSTALLED SMOKE DETECTORS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: all broken smokedetectors were replaced and tested.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 November 2010
Resolved
VESSEL HAS UNAUTHORIZED WIRES RUNNING THROUGHOUT THE ENGINE ROOM, INCLUDING SOME WITH EXPOSED WIRING CAUSING AN UNSAFE WORKING ENVIRONMENT.
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: PSC Examiners cleared deficiency. All wires were removed from engine room.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 16 November 2010
Resolved
SOLAS 74 CH II-1 REG 27 (a)(ii)
VESSEL DOES NOT HAVE NON-CONDUCTING MATS OR GRATING AT THE HIGH VOLTAGE PANEL FOR THE MAIN CONTROL PANELS OF THE SHIP SERVICE GENERATORS.
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: All non-conduting mating was replaced and spare matting is on board.
Fire Fighting › International Shore Connection › Washers
Issued 16 November 2010
Resolved
SOLAS 74 CH II-2 REG 5(h)
VESSELS INTERNATIONAL SHORE CONNECTION WAS MISSING 4 WASHERS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: all required hardware for the international shore connection was presant.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 November 2010
Resolved
SOLAS 74 CH II-1 REG (a)(ii)1
EMERGENCY LIGHTING FOR THE PORT SIDE EMBARKATION DECK DID NOT OPERATE PROPERLY.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: Light bulbs were replaced on emergency lighting.
Lifesaving › Launching Appliances › Release Mechanism
Issued 16 November 2010
Resolved
SOLAS 74 CH III REG 15 (p)(ii)
VESSELS HYDROSTATIC RELEASE EXPIRATION DATE FOR THE PORT SIDE LIFERAFT HAD MULTIPLE MONTHS PUNCHED OUT AND NO YEAR. VESSEL COULD NOT PROVIDE A CERT. TO CONFIRM DATE OF EXPIRATION.
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: three new hydostatic releases were ordered and installed on the liferafts.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 16 November 2010
Resolved
SOLAS 74 CH III REG 12
LIFEBOATS FOOD RATIONS AND PYROTECHNICS WERE NOT STORED IN THE LIFEBOAT AS REQUIRED.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: All food and and pyro was placed in weatherproof boxes and was in the lifeboats.
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 16 November 2010
Resolved
33 USC 1223(b)
THE VESSEL WAS NOT ABLE TO PROVIDE HOT WATER TO THE SHIPS HOSPITAL, GALLEY, SHOWERS, OR CREW CABINS CAUSING AN UNSANITARY ENVIRONMENT FOR THE CREW.
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: Water heater was repaired, and operated as designed.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 16 November 2010
Resolved
33 USC 1223(b)
AN INFESTATION OF ROACHES WERE FOUND IN VESSELS DRY STORES. VESSEL IS TO PROVIDE DOCUMENTATION FOR PROOF OF FUMIGATION TO VESSELS DRY FOOD STORES.
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: fumigation was carried out.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 16 November 2010
Resolved
33 USC 1223(b)
VESSEL WAS NOT ABLE TO PROVIDE A WORKING MARINE SANITATION SYSTEM TO FLUSH THE VESSELS TOILETS.
Action required: 705 - Other - as specified
Resolved 21 November 2010
Resolution: system repaired. toilets in working order.
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 16 November 2010
No resolution recorded
33 USC 1223(b)
VESSEL HAS NO OPERATIONAL SHOWERS. CREW IS USING HOSES TEMPORARLY ATTACHED FROM THEIR SINK TO SHOWER STALL.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolution: pipeing and fixtures were ordered and installed.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 27 January 2009
Resolved
A 3” to 4” hole was found in the PORT forward engine room bulkhead is compromising the class (A) fire boundary. Vessel must make proper repairs to bulkhead prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper and permanent repairs to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 27 January 2009
Resolved
PORT forward class (A) fire door leading to engine room held open by tie downs. To allow cables to run through the door opening. Vessel must remove electrical cables running through door to allow door to function as designed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper removal of electrical cables to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Engineering › Generator (propulsion/auxiliary-electric) › Heating Element Circuitry
Issued 27 January 2009
Resolved
The vessel has excessive exhaust leaks on 3 out of 4 ship service generators. Resulting in elevated levels of carbon monoxide in engine room causing unsafe working conditions. Vessel must make proper repairs to affected generators.
Action required: 705 - Other - as specified
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper and permanent repairs to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Fire Fighting › Combustible Materials › Grounds
Issued 27 January 2009
Resolved
3 out of 4 of the ship service generators have excessive lube oil, fuel oil, and jacket water leaks. This is causing excessive lube oil to cover engine and pool up into the bilge causing a major fire hazard. Vessel must eliminate fire hazard and ensure machinery arrangement remains in class.
Action required: 705 - Other - as specified
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper machinery arrangement to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 27 January 2009
Resolved
Vessel has unapproved high voltage cable running from the main switchboard through engine room and out on deck to power the refrigerated containers. Vessel has exposed cable connections on back of vessels main switchboard that are causing a high risk of electrical shock to vessel crew. Vessel must establish watertight integrity, fire boundaries, shock hazard prevention, reinstall all panels to mai
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper and permanent repairs to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Deck/Cargo › Holds/Tanks › Cargo Tank Drainage
Issued 27 January 2009
Resolved
No 1 fuel oil tank vent piping system has 3 wasted holes along piping that run through the forward hydraulic room. Vessel must make proper repairs to piping to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper and permanent repairs to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 27 January 2009
Resolved
Class (A) fire door is held fully open leading to the forward hydraulic room due to 3 barrels of hydraulic oil blocking the door. Vessel must properly stow the barrels of hydraulic oil to allow the fire door to function as designed.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper stowage to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Stability › Watertight Integrity › General
Issued 27 January 2009
Resolved
Water tight door held open by tie downs to allow high voltage cables to run through the oil spill contamination room going out on deck. Vessel must remove cables to allow water tight door to function as designed and ensure vessels water tight integrity prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper removal of cables to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 27 January 2009
Resolved
Vessel has no electrical mating by the high voltage panel on the starboard side of the engine room. Vessel must install mating prior to departure from port.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper installation of mating to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Electrical › Electric Supply System (service) › Cable
Issued 27 January 2009
Resolved
Vessel has exposed wires on the refrigerator A/C compressor and thermostat. Vessel must make proper repair prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper and permanent repairs to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 27 January 2009
Resolved
Vessel sewage treatment discharge line is leaking due to wasted piping. Make permanent repairs no later than 03FEB2009 to satisfaction of certification issuing authority.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2009
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper and permanent repairs to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 January 2009
Resolved
Vessel has multiple light covers missing in the engine room and through the accommodation spaces. Vessel must make proper repairs to all effected lights not later than 03FEB2009.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 February 2009
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper and permanent repairs to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 27 January 2009
Resolved
The vessel is not incompliance with guidelines in their SMS section 8.7.1 of the operations manual, this is evidenced by lack of reporting and lack of maintains to the vessel’s ship service diesel generators.
Action required: 705 - Other - as specified
Resolved 3 February 2009
Resolution: Received Class survey report attesting to the implementation of Safey Managment System guidelines to properly report non-conformities to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 27 January 2009
Resolved
Vessel was unable to successfully complete an abandon ship drill.
Action required: 705 - Other - as specified
Resolved 3 February 2009
Resolution: Port State Control Officers witnessed a successful abandon ship drill. The deficiency has been rectified.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 27 January 2009
Resolved
Clear grounds were established due to general impressions and observations that serious deficiencies exist in the safety, firefighting, water tight integrity, structural fire protection & crew training. Based on the deficiencies listed above the local OCMI/COTP zone Houston/Galveston has determined your vessel is to be detained under SOLAS 74 Ch. 1, Reg. 19.
Action required: 705 - Other - as specified
Resolved 3 February 2009
Resolution: Port State Control Officers re-inspected all the deficiencies rectified by attending Class surveyors and are satisfied with the findings. Vessel is released from IMO Detention.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 January 2009
Resolved
Both vessel’s steering gears motors have fractured guards on motor’s cooling fan. Vessel must make proper repairs to motor guards not later than 03FEB2009.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2009
Resolved 3 February 2009
Resolution: Received Class survey report attesting to proper and permanent repairs to the satisfaction of local Officer in Charge of Marine Inspections. The deficiency has been rectified.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 15 December 2008
Resolved
Vessel main propulsion cannot go astern. Prior to departure from COTP Houston/Galveston, provide a detailed report from certificate issuing authority to local OCMI attesting to the cause of the machinery failure, completion of satisfactory repairs, verification the machinery is fully operational, and machinery remains in Class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2008
Resolved 15 December 2008
Resolution: Recieved class report attesting to the repairs of the MDE.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 10 November 2008
Resolved
All 4 of the ship service generators are leaking exhaust. Prior to departure.
Action required: 705 - Other - as specified
Due 10 November 2008
Resolved 10 November 2008
Engineering › Compressed Air System (control) › Valve
Issued 3 November 2008
Resolved
Vessel's main diesel engine is unable to go astern. Vessel must make proper repairs and submit attestation from certificate issuing authority prior to departure from Pier 18, Galveston, TX.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Resolution: Received surveyor’s report satisfying requirement of 03 NOV 2008 Op Control.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 November 2008
Resolved
Vessel has excessive oil and exhaust leaks on all 4 ship service generators. Vessel must make proper repair to generators by 10NOV08.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2008
Resolved 10 November 2008
Resolution: Re-issued same deficiency.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 14 April 2008
Resolved
During inspection of hospital space, Port State Control Officers found crew utilizing hospital as crew accommodation. Vessel's Master was quickly notified and crew was immediately removed from the hospital space.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Resolution: The deficiency was rectified on the spot to the satisfaction of attending Port State Control Officers.
Electrical › Electric Supply System (service) › Cable
Issued 18 March 2008
Resolved
Vessel was found with exposed wires (not hot) on bridge. Vessel is to make repairs to satisfaction of class and provide report to local [name withheld] 18 APR 2008. SOLAS 04 CH II-1/45/1.1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 14 April 2008
Resolution: The deficiency has been rectified by attending CG Inspector.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 March 2008
Resolved
Vessel was found with nine light fixtures in engine room with broken or missing bulb covers. Vessel is to make repairs to satisfaction of class and provide report to local [name withheld] 18 APR 2008. SOLAS 04 CH II-1/45/1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 14 April 2008
Resolution: The deficiency has been rectified by attending CG Inspector.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 18 March 2008
Resolved
Vessel was found with crew member living in hospital space. Vessel placed crew member in owners cabin, and cleaned hospital. PWSA 33 USC 1223
Condition: Placed in Improper Service
Due 18 March 2008
Resolved 18 March 2008
Personnel › Training › Fire Fighting Basic
Issued 18 March 2008
Resolved
Vessel failed three fire and three abandon ship drills, after crew training vessel passed their fourth fire and abandon ship drill. SOLAS CH III/19/2.1
Condition: Improper/Lack of Maintenance
Due 18 March 2008
Resolved 18 March 2008
Engineering › Diesel Engine (auxiliary) › Valve
Issued 18 March 2008
Resolved
Vessel has multiple leaks of oil and fuel oil on all three gen-sets. Repair or replace valve packing and fuel fittings prior to 18 Apr 2008.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 21 April 2008
Resolution: Engine was repaired with new gaskets.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 July 2007
Resolved
#1 Main diesel generator did not have insulation covering the exhaust side of the turbo, to protect it from fuel failure impringment.
SOLAS 74/78 (2004) II-2 reg. 4.2.2.6
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 23 August 2007
Resolution: Received report from NKK attesting to renewal and proper installation of insulation covering the MDG. Deficiency cleared.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 July 2007
Resolved
Steering gear compartment did not have non-slip surfaces and or including grating.
SOLAS 74/78 (2004) II- 2 reg 29.13.2
Condition: Improper Installation
Due 10 August 2007
Resolved 23 August 2007
Resolution: Received report from NKK regarding vessel''s non-slip surface and grating in emergency steering space. Class attested to vessel installation of wood stepping area in space. Deficiency cleared.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 11 July 2005
Resolved
Vessels fire control plan does not clearly reflect Class A and B fire boundries. Ammend plan to show proper boundries.
Action required: 705 - Other - as specified
Due 11 August 2005
Resolved 21 July 2005
Resolution: RECIEVED CLASS REPORT ATTESTING TO REPAIRS
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 July 2005
Resolved
Have class attest to the proper operation and fit of class A fire doors in the galley.
Action required: 705 - Other - as specified
Due 25 July 2005
Resolved 21 July 2005
Resolution: RECIEVED CLASS REPORT ATTESTING TO REPAIRS
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 July 2005
Resolved
Ships air compressor port side missing fan guard.
Due 11 July 2005
Resolved 11 July 2005
Engineering › Lubricating Oil Service System › Piping
Issued 11 July 2005
Resolved
Ships Aux Gen #1 and #2 oil return lines were disconeted allowing oil to drip down the hot engine.
Due 11 July 2005
Resolved 11 July 2005
Navigation › Piloting/Steering › Gyro Compass
Issued 14 March 2005
Resolved
Provide service tecnicians documentation attesting to the proper operation of the vessels gyrocompass prior to departure from port.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2005
Resolution: RADIO HOLLAND COMPLETED REPAIRS TO GYROCOMPASS
Construction/Loadline › Structures › Plowshare Breakwater
Issued 14 June 2004
Resolved
Have Certificate Issuing Authority address handrail damage on both sides of main deck and provide report to USCG IAW ICLL 66 REG 25(2)
Due 13 July 2004
Resolved 13 July 2004
Resolution: Received class report attesting to correction of deficiency
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 14 June 2004
Resolved
Ensure all deck containments close properly IAW 33 CFR 155.320.
Due 13 July 2004
Resolved 13 July 2004
Resolution: received class report attesting to correction of deficiency.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 14 June 2004
Resolved
Door to engine room starboard side not closing. Fix or replace door/spring assembly.
Due 13 July 2004
Resolved 13 July 2004
Resolution: received class report attesting to correction of deficiency.
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 14 June 2004
Resolved
Repair oil leaks on port side outboard generator to the satisfaction of Certificate Issuing Authority IAW Solas 4 Ch II-2 Reg 33(a).
Due 13 July 2004
Resolved 13 July 2004
Resolution: received class report attesting to correction of deficiency.
Navigation › Collision/Grounding Avoidance
Issued 12 May 2003
Resolved
Radar not working upon arrival. Make repairs to number 2 radar and provide technician report attesting to proper operation of the radar. LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2003
Resolution: Received technician report attesting to the proper operation of the number 2 radar.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 2 May 2002
Resolved
EMERGENCY GENERATOR NOT EQUIPPED WITH AN INDEPENDENT SECONDARY MEANS OF STARTING GENERATOR. SOLAS 74/78 CHAPTER II-1 REG 44.2.1
LEGACY COMPONENT DESC: Starter
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 24 October 2002
Resolution: Previously corrected by MSO Tampa.
Pollution Prevention/Response › Prevention Equipment
Issued 2 May 2002
Resolved
WASTE OIL DISCHARGE CONNECTIONS HAVE NO CONTAINMENT. LEGACY COMPONENT DESC: Fixed Containment
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 24 October 2002
Resolution: Previously corrected by MSO Tampa.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 2 May 2002
Resolved
TOILET IN HOSPITAL LEAKING AT BASE. ILO 147 LEGACY COMPONENT DESC: Toilet
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 24 October 2002
Resolution: Corrected on site.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 May 2002
Resolved
LUBE OIL DISTRUBUTION PIPES LEAKING FROM LUBE OIL PURIFIERS ONTO DECK OF ENGINE ROOM PORT SIDE FORWARD (FROM OVERHEAD) SOLAS 74/78 CHAPTER II-1 REG 26. SOLAS 74/78 CHAPTER-2 REG 15/3
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 24 October 2002
Resolution: Deficiency Previously cleared by MSO Tampa.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 May 2002
Resolved
DECK PLATING AROUND ALL FOUR OF SHIPS SERVICE GENERATORS COVERED WITH OIL. SOLAS 74/78 CHAPTER II-1 REG 26. SOLAS 74/78 CHAPTER II-2 REG 15/3.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 24 October 2002
Resolution: Deficiency previously cleared by MSO Tampa.
Engineering
Issued 4 October 2000
Resolved
REPAIR OR RENEW THE 6 BALLAST WATER GAUGES, AND THE FIRE AND FUEL PUMP GAUGES. GAUGES ARE BROKEN. 74 II/33-5 AMENDED
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Fire Fighting
Issued 4 October 2000
Resolved
NOTED ALL FIRE DOORS TO ENGINE ROOM DO NOT CLOSE PROPERLY. ADJUST AND/OR REPAIR SO THAT ALL FIRE DOORS CLOSE WITHOUT ASSISTANCE. SOLAS 74 II-2/23 UNAMENDED
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Lifesaving
Issued 4 October 2000
Resolved
OBTAIN PROPER LIFE RAFT LAUNCHING INSTRUCTIONS FOR PORT AND STARBOARD LIFE RAFT STATIONS. NOTED INSTRUCTIONS TO HAVE DIFFERENT RELEASE DEVICE. SOLAS 74/ III-9 AMENDED
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Navigation
Issued 4 October 2000
Resolved
REPLACE HOUSINGS TO BOTH STEERING GEAR PUMPS. NOTED TO BE COMPLETELY WASTED. SOLAS II-1/29 UNAMENDED
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Engineering
Issued 5 June 1998
Resolved
Small discharge containment not plugged while vsl was recieving bunkers.
Condition: Unknown
Due 5 June 1998
Resolved 26 June 1998
Navigation
Issued 5 June 1998
Resolved
Charts 12311 and 12304 not currently corrected.
Condition: Unknown
Due 5 June 1998
Resolved 26 June 1998
Navigation
Issued 5 June 1998
Resolved
U.S. Coast Pilot not corrected.
Condition: Unknown
Due 5 June 1998
Resolved 26 June 1998
Documentation
Issued 17 December 1990
Resolved
PRE-ARRIVAL TEST NOT LOGGED AS PER 33 CFR 164.25_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1990
Resolved 17 December 1990
Documentation
Issued 17 December 1990
Resolved
PERSON IN CHARGE OF VESSEL FAILED TO GIVE ADVANCE NOTICE OF ARRIVAL TO THE C.O.T.P., AS PER 33 CFR 160.207._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1990
Resolved 17 December 1990
Navigation
Issued 26 February 1990
Resolved
VESSEL MHAD NO CURRENT U.S. COAST PILOT FOR AREA TRANSITTED AS PER 33CFR164.33(A)(2)(I)
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Navigation
Issued 26 February 1990
Resolved
VESSEL HAD NO CURRENT LARGE SCALE CHART FOR AREA TRANSITTED AS PER 33CFR164.33(A)(1)(II)
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Navigation
Issued 26 February 1990
Resolved
VESSEL HAD NO FOREIGN EQUIVALENT OR USCG LIGHT LIST FOR AREA TRANSITTED AS PER 33CFR164.33(A)(2)(II)
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Navigation
Issued 28 February 1989
Resolved
CHARTS 18720, 18740, 18749, 18746, 18751 NOT CORRECTED TO DATE. CORRECTIONS REQUIRED BY 33CFR164.33(A)(1)
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Navigation
Issued 29 February 1988
Resolved
U.S. COAST GUARD LIGHT LIST VOL. VI, 1987 ED. NOT CORRECTED TO DATE AS REQUIREDBY 33CFR164.33. FOLLOWING NTM CORRECTION NOT POSTED: 88/05. NO FOREIGN EQUIVALENT ONBOARD.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Navigation
Issued 17 February 1987
Resolved
USCG LIGHT LIST VOL. VI AND CURRENT YEAR TIDE AND TIDAL CURRENT TABLES NOT ON BOARD. NOS CHART 18720 AND COAST PILOT VOL. 7 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 17 February 1987
Resolved 17 February 1987
Navigation
Issued 12 September 1984
Resolved
NOS CHARTS 18720,18751,NOS VOL 7 COAST PILOT, USCG VOL III LIGHT LIST NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 12 September 1984
Resolved 12 September 1984