EVELYN is a 1983 freight ship. The Coast Guard has recorded 26 inspections since 1984, most recently in June 2006, along with 25 deficiencies and 6 operational controls.

Records from 1984 to 2006. Most recent: inspection, 23 June 2006.

Built
1983
Last inspected
23 June 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8301644 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
229512
Flag
PHILIPPINES
—
Maury page id
psix-229512

Inspections, by type

…with no type recorded19
Years with a record 15 calendar years (1984–2006)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it26552 - Displacement, Ton
21340 - Dead Weight, Ton
7885 - Regulatory (Subpart C or D), Net Ton
12905 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

23 June 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2689392
15 June 2006 NPV Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2679665
6 December 2005 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2546892
5 August 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2453885
18 July 2005 STCW 95 Exam · MARPOL Annex V Examination · ISPS II Exam · ILO-147 Exam · Ballast Water Examination · NPV Safety Exam · ISM Exam · MARPOL Annex I Examination · Loadline Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2435629
1 December 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1953214
1 December 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1992912
8 August 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1992720
16 July 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1992384
19 June 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1821512
1 June 2003 Deficiency Check · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1799843
12 June 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 290940
5 August 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 104641
4 October 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 433397
5 December 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 372797
5 December 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1151719
13 October 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 729789
12 October 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 371228
28 August 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 352804
24 September 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 345955
12 July 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 338177
10 December 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 327244
3 September 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 318179
10 June 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 308931
10 August 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 303488
19 July 1984 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 515281

Deficiency record · 25

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 June 2006 Resolved
The Oily Water Separator oil content meter and alarm are not operating properly. Do not use Oily Water Separator while in U.S. waters until proper operation of Oily Water Separator is proven.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 22 June 2006
Resolution: Received report from Class NK attesting to OWS proper operation.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 18 July 2005 Resolved
Vessel's fire control plan does not clearly show fire boundaries with respect to class "A" and class "B" bulkheads. SOLAS 74 amended CH. 2-II/Reg. 20. Correct to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 July 2005
Resolved 8 December 2005
Resolution: Deficiency was corrected to the satisfaction of attending class surveyor on 21SEP05.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 July 2005 Resolved
All hydraulic rams and metal piping for hatch covers have hydraulic leaks. SOLAS 74 amended CH. I/Reg. 1. Correct to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 July 2005
Resolved 8 December 2005
Resolution: Deficiency was corrected to the satisfaction of attending class surveyor on 21SEP05.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 July 2005 Resolved
Hydraulic hoses for rams on #2 fwd and aft and #3 aft are rusted and worn. SOLAS 74 amended CH.I/Reg. 11. Correct to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 July 2005
Resolved 8 December 2005
Resolution: Deficiency was corrected to the satisfaction of attending class surveyor on 21SEP05.
Accommodation/Occupational Safety › Occupational Safety
Issued 1 December 2003 Resolved
DECKS IN ENGINE ROOM COVERED WITH EXCESSIVE OIL CREATING SLIPPING AND FIRE HAZARDS. A VIOLATION OF ILO 147. TO BE CORRECTED WITHIN 30 DAYS OR PRIOR TO NEXT U.S. PORT AFETR SAILING FOREIGN..
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 January 2004
Resolved 1 December 2003
Resolution: RECEIVED STATEMENT FROM VESSEL MASTER STATING ABOVE DEFICIENCY ADDRESSED. DEFICIENCY CLEARED.
Lifesaving › Lifeboat Equipment
Issued 1 December 2003 Resolved
VESSEL'S PORT LIFEBOAT LACK 12 FOOD RATIONS, 1 BUCKET, 1 DIPPER WITH LANYARD AND 30 LITRES OF FRESH WATER IN WATERPROOF CONTAINER, A VIOLATION OF SOLAS 74 UNAMENDED, CH III, REG 11(a) (xii), (ii), AND (xiii). CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Food Ration
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2003
Resolved 1 December 2003
Resolution: RECEIVED FAX OF PROOF OF PURCHASE FOR ABOVE ITEMS. DEFICIENCY CLEARED.
Fire Fighting › Fire Hydrants › Condition
Issued 1 December 2003 Resolved
VESSEL'S FIRE HYDRANT ON FORECASTLE, STARBOARD SIDE, WAS FOUND TO BE LEAKING EXCESSIVELY, A VIOLATION OF SOLAS 74 UNAMEND, CH II-1, REG 5 (e). CORRECT WITHIN 30 DAYS OR PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 January 2004
Resolved 18 July 2005
Accommodation/Occupational Safety › Occupational Safety
Issued 1 December 2003 Resolved
VESSEL HAS NUMEROUS OXY/ ACETYLENE CYLINDERS, DRUMS AND EXCESSIVE DUNNAGE ON MAIN DECK, A VIOLATION OF ILO-147 PART 7 PARA B AND D. CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Welding/Hot Work
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2003
Resolved 1 December 2003
Resolution: RECEIVED STATEMENT FROM VESSEL MASTER ADDRESSING ABOVE ITEM. DEFICIENCY CLEARED.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 1 December 2003 Resolved
VESSEL'S SOPEP WAS NOT APPROVED BY EITHER FLAG OR CLASS, A VIOLATION OF 33 CFR 151.29(a). CORRECT WITH IN 30 DAYS OR NEXT U.S. PORT AFTER SAILING FOREIGN. LEGACY COMPONENT DESC: SOPEP
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 January 2004
Resolved 18 January 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 1 December 2003 Resolved
VESSEL'S PORT BUNKER LINE WAS FOUND NOT BLANKED OFF , A VIOLATION OF 33 CFR 156.120(e). CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2003
Resolved 1 December 2003
Resolution: RECEIVED STATEMENT FROM VESSEL MASTER ATTESTING TO BUNKER LINE BEING BLANKED. DEFICIENCY CLEARED.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 1 December 2003 Resolved
VESSEL'S PORT BUNKER STATION WAS FOUND WITH INADEQUATE FIXED CONTAINMENT, A VIOLATION OF 33 CFR 156.130(d). CORRECT WITHIN 30 DAYS OR PRIOR TO NEXT U.S. BUNKERING. LEGACY COMPONENT DESC: Fixed Containment
Condition: Placed in Improper Service
Action required: 703 - Prior to bunkering operations
Due 1 January 2004
Resolved 18 January 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 1 December 2003 Resolved
Observed excessive amounts of various containers and 1/2 drums of oily water within the steering flat, creating a hazardous condition. Violation of ILO 147. To be corrected, prior to departure. LEGACY COMPONENT DESC: Drums
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2003
Resolution: Observed the items were removed. Def. cleared.
Construction/Loadline › Markings
Issued 1 June 2003 Resolved
Load Line must be marked in contrasting color. ICLL 66, Reg. 8, Annex B. Correct within 30 days. LEGACY COMPONENT DESC: Load Line Mark
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 9 June 2003
Resolution: Received faxed report from class society attesting to proper load line markings.
Lifesaving › Lifeboat Equipment
Issued 1 June 2003 Resolved
07 food rations wasted. Solas 74/78, Ch. III, Reg. 38.5.18. Correct prior to departure from port. LEGACY COMPONENT DESC: Food Ration
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2003
Resolution: Received faxed report from class society attesting to new food rations on board the vessel.
Fire Fighting › Emergency Fire Pumps
Issued 1 June 2003 Resolved
Emergency fire pump did not start in a timely manner. Solas 74/78, Ch. II/2, 2.2.7. Correct prior to departure from port. LEGACY COMPONENT DESC: Power Source
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2003
Resolution: Received a faxed report from class society attesting to the proper operation of the emergency fire pump.
Fire Fighting
Issued 12 June 2001 Resolved
Emergency fire pump could not provide adequate water pressure. Solas 74(Amended) II-2/21. Prove proper operation to satisfaction of class.
Condition: Unknown
Due 12 June 2001
Resolved 21 June 2001
Engineering
Issued 12 June 2001 Resolved
Several small soft patches on MDE & Generator sea water cooling lines. SOLAS 74 I/11. Repair to sat of Safety Construction Cert issuing authority.Note: NKK surveyor onboard during exam. NKK issued condition of class for repairs to be completed NLT 12Jul01.
Condition: Unknown
Due 12 July 2001
Resolved 1 June 2003
Resolution: Deficiency cleared by MSO Philadelphia.
Lifesaving
Issued 4 October 1999 Resolved
Repair and prove proper operation of embarkation light in way fo stbd lifeboat where broken prior to departure from this port. SOLAS 74 III/19
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Navigation
Issued 4 October 1999 Resolved
PROVE POROPER OPERATION OF ECHO DEPTH SOUNDER PRIOR TO DEPARTURE FROM THIS PORT. 33 CFR 164.35(i)
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Navigation
Issued 4 October 1999 Resolved
Provide Coast pilot and inland rules of the road prior to departure from this port. 33 CFR 164.33
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Lifesaving
Issued 4 October 1999 Resolved
Renew lifeboat transponders where expired prior to departure from this port. SOLAS 74 amd III/6
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Lifesaving
Issued 4 October 1999 Resolved
Prove proper operation of air motor to life boat davit prior to departure from this port. SOLAS 74 I/11
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Unknown
Issued 4 October 1999 Resolved
Provide an AB and an OS in accordance with the Safe Maning Certificate or aletter from the flag state approving an exemption prior to departure from this port.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Fire Fighting
Issued 12 October 1994 Resolved
THE FEMALE FITTING ON TWO FIRE HOSE WERE BENT AND WOULD NOT FIT ON TO STANDPIPES. SOLAS CH II-2 REG.4(6.1)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Navigation
Issued 12 October 1994 Resolved
VESSEL WAS MISSING CORRECTIONS ON N.O.A.A. CHART #18524.
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994

Ownership record