Records from 1984 to 2026. Most recent: inspection, 13 February 2026.
Inspection history · 78
13 February 2026
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8310474
21 January 2025
Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8067331
12 March 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7878545
29 November 2023
Damage Survey
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7831235
27 November 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7830231
10 January 2023
Drydock Exam · In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7618856
9 February 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7393785
21 June 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7234907
6 January 2021
Administrative Inspection · Annual Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7073098
7 February 2020
COI Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6904639
4 March 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6636040
8 February 2019
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6622426
7 February 2019
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6633438
9 January 2019
Plan Review "T" Boat · Drydock Exam · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6607836
24 April 2018
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6402672
6 March 2018
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6372877
16 January 2018
Examination of Repairs · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6343620
17 May 2017
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6152487
24 April 2017
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6125992
23 January 2017
Drydock Exam · Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6073425
2 February 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5808883
7 May 2014
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4853201
29 May 2012
Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4328758
3 March 2010
Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3689297
2 March 2010
COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3684811
29 January 2010
Hull Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3672367
13 April 2009
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3445789
4 February 2009
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3412324
5 May 2008
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3199213
8 February 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3143982
16 July 2007
Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2973449
24 April 2006
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2630378
24 February 2006
Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2610471
18 January 2005
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2276233
19 April 2004
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2047311
24 February 2004
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2009039
24 June 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1825693
22 April 2003
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1777773
1 May 2002
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1611333
20 February 2002
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1487714
29 July 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 154178
21 February 2001
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1391489
3 July 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 42068
8 February 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 717074
2 February 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 154251
2 February 2000
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1449290
20 January 2000
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1430810
10 May 1999
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 799052
8 March 1999
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1444108
8 July 1998
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 796430
25 February 1998
Hull Examination · Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1406274
4 February 1997
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1406043
19 July 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1086814
22 February 1996
COI Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1452112
1 March 1995
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 854776
6 February 1995
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1389985
4 February 1994
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1461552
18 January 1994
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1436835
3 February 1993
MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1438022
26 February 1992
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 959559
14 February 1992
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1267581
19 February 1991
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1214536
14 January 1991
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 914407
26 February 1990
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 904444
29 January 1990
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1224767
22 February 1989
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1348174
30 January 1989
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 896998
25 February 1988
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1025364
14 January 1988
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1319903
24 July 1987
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1029887
18 June 1987
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1312158
27 March 1987
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1326219
18 February 1987
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1326062
10 April 1986
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 998455
29 January 1986
Credit Drydock
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 997466
1 November 1985
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1299755
25 April 1985
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 978890
11 May 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280900
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2025
Resolved
Electrical equipment on a vess must be installed and maintained to minimize accidental personnel contact with energized parts. 46 183.200(c).
03 outlets were found with loose wiring and open receptical boxes. One forward and one aft in the Engine Room and one in the Engineer’s workspace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2025
Resolved 25 February 2025
Resolution: Crew replaced all the noted outlets and propely secured the wiring.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 February 2025
Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
Seal on watertight door on forward bulkhead of the engine room did not seal on the upper inboard corner of the door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2025
Resolved 25 February 2025
Resolution: Crew has replaced the gasket and demonstrated a proper seal.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 February 2025
Resolved
Suitable guards shall be installed in way of all exposed and hazardous places such as gears, machinery, etc.
Unsafe conditions. No guards installed around PTO of the port and starboard fire pumps.
46 CFR 177.35-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2025
Resolved 25 February 2025
Resolution: Guards were installed over the belt drives for the fire pumps.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
Vessel was found missing 01 life vest. Maximum number of passengers is reduced to 149 until a replacement life vest is obtained.
Action required: 705 - Other - as specified
Resolved 1 March 2025
Resolution: Crew replaced 01 missing lifevest.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 March 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards. Vsl had terminated wires mounted above port side engine. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2024
Resolved 2 May 2024
Resolution: Recieved photo of repaired wires.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 March 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards. Vsl had electrical wire not properly secured to housing of aft engine room light. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2024
Resolved 2 May 2024
Resolution: Recieved photo of repaired wire inside electrical housing.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 March 2024
Resolved
Vessels must have on board a properly installed, operational Coast Guard type-approved AIS. Vsl AIS was inoperable. 33 CFR 164.46(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2024
Resolved 2 May 2024
Resolution: Recieved photo of AIS transmitting VAGABOND data.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 May 2023
Resolved
Each vessel subject to Title III of the Communications Safety Act must have an inspection of required equipment once every 5 years. Vessels Safety Radio Certificate and Bridge-to-Bridge Certificate are expired.
705: Vessel is restricted to 1000 feet from shore until deficiency is rectified.
47 CFR 80.59 (a)(2)
Action required: 705 - Other - as specified
Due 15 May 2023
Resolved 19 May 2023
Resolution: Received renewed Safety Radio and B-to-B Certificates.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 January 2023
Resolved
Where cable protection is carried through watertight decks or bulkheads, the installation shall be such
that will insure the watertight integrity of the structure. There are several wire runs penetrating subdivision bulkheads that require sealing. Wire run for new bow thruster, replaced upper bulkhead of E/R and new wire run to the steering gear going through 2 bulkheads.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 1 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2023
Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. Wire splices for step light, port side, are not enclosed in a junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 1 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2023
Resolved
All lights, receptacles, and switches exposed to the weather shall be watertight. Light cover, starboard side main weatherdeck is missing cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 1 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 January 2023
Resolved
Suitable covers, guards, or rails
shall be installed in way of all exposed
and hazardous places such as gears,
machinery, etc. Port and Starboard engines are missing guards in way of gears and belts.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 1 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 February 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section.
10 BC portable fire extinguisher was mounted in machinery space. 40 BC required. Vessel restricted from the carriage of passengers.
46 CFR 181.500(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2022
Resolution: Owner purchased and installed 40 BC for machinery space.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 February 2022
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge.
Pressure gauge broken on fire pump.
46 CFR 181.300(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2022
Resolved 9 March 2022
Resolution: New gauge put into service. Received video of satisfactory operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2022
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant.
Retroreflective tape deteriorated on aft life ring.
46 CFR 185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2022
Resolved 9 March 2022
Resolution: New retroreflective tape put on life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 04 life jackets found in unsatisfactory condition. Prove proper number and type of life jacket for each person carried on board. Limited to the carriage of 146 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 April 2021
Resolution: Replace the 04 lifejackets
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 25 March 2021
Resolved
A vessel of more than 65 feet in length must carry at least one rescue boat unless the cognizant OCMI determines that the vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. Current rescue platform is too long. Prove sufficient installation of platform.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2021
Resolved 26 April 2021
Resolution: Vessel modified platform to allow proper operation
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 25 March 2021
Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station; the compass must be illuminated. Compass light is inopperable. Restricted to day light operations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 26 April 2021
Resolution: Vessel repaired compass light
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 March 2021
Resolved
Construction of the vessel must be adequate for the intended route and service. Vessel is missing flat bar iwo of port shaft. Show proper replacement of flat bar to satisfy structural conditions.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2021
Resolved 26 April 2021
Resolution: vessel replaced the flat bar.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2021
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. All equipment, including switches, fuses, lampholders, etc., must be suitable for the voltage and current utilized. Extension cord and non-marine type inverter wired in workshop area feeding cash register. Demonstrate suitable installation of marine type inverter and cable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2021
Resolved 26 April 2021
Resolution: Vessel hard wired in a marine type power inverter
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 January 2021
Resolved
A vessel of more than 65 feet in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. 01 ring buoy found to be in wasted condition beyond serviceable condition. 01 ring buoy missing retro-reflective tape. Provide evidence of (03) satisfactory ring buoys on board vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 26 April 2021
Resolution: replaced ring bouy and replaced retro on others
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 February 2020
Resolved
A vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under 67.9(c) must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. COD is expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2020
Resolved 9 March 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 7 February 2020
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator and hold a marine radio operator permit or higher class license. Master is missing radio operator permit. 47 CFR 80.159(e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 9 March 2020
Resolution: Master has Marine Radio Operator Permit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 February 2020
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which no floating waterlight is required. Floating waterlight battery is expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 9 March 2020
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 7 February 2020
Resolved
The stability letter must be posted under glass or suitable transparent material, such that all pages are visible, at the operation station of the vessel. Post stability letter.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 9 March 2020
Resolution: Stability Letter posted under glass.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 7 February 2020
Resolved
All escape hatches and other emergency exits used as a means of escape must be marked on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary
by the cognizant [name withheld] emergency exit labels to meet requirement on emergency escape hatches.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 9 March 2020
Resolution: Updated emergency escape means to say "Emergency Exit, Keep Clear"
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 February 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and nautical publications. Need up-to-date navigation rules.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 9 March 2020
Resolution: Up-to-date nav rules onboard
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 February 2020
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Mount portable light outside machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 9 March 2020
Resolution: Flashlight mounted O/S mach space
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 February 2020
Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. Forward emergency escape hatch stuck closed, corrected on spot.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 7 February 2020
Resolution: Hatch corrected so it is able to open easier.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 March 2019
Resolved
Vessel's propulsion system and associated emergency equipment must be readily available for immediate use. Vessel was conducting repairs on engines and could not show operation of the fire pump, bilge pump, or propulsion system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2019
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 6 March 2018
Resolved
Replace mechanical seal on port MDE PTO pump.
Condition: Invalid
Due 6 April 2018
Resolved 24 April 2018
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 24 April 2017
Resolved
Reapply retro tape to PFD's as marked.
Due 24 May 2017
Resolved 17 May 2017
Navigation › Piloting/Steering › Marine Charts
Issued 24 April 2017
Resolved
Update marine chart with currently corrected copy.
Due 24 May 2017
Resolved 17 May 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 24 April 2017
Resolved
Repair excessive oil leaks at valve cover.
Due 24 May 2017
Resolved 17 May 2017
Engineering › Lubricating Oil Service System › Gauge
Issued 29 May 2012
Resolved
Properly repair or replace lube oil pressure gauge.
Due 29 June 2012
Resolved 23 January 2013
Documentation › Certificates/Documents › Stability Letter
Issued 29 May 2012
Resolved
Issued CG-835 reducing maximum persons allowed to 134 based on the assumed average weight per person of 185 pounds and in accordance with 46 CFR 178.320 amended by FR vol. 75, No. 239, USCG-2007-0030. Reduction will remain in effect until Owner/Operator submits stability certification compliance to Coast Guard.
Due 29 May 2013
Resolved 13 September 2012
Resolution: New Stability Letter has been issued by the Marine Safety Center allowing a maximum of 160 persons.
Engineering › Bilge Water Management System › Not Operational
Issued 2 March 2010
Resolved
Prove proper operation of the vessel's fixed bilge system. System unable to pump out from the storage void space all other compartments system worked satisfactory.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 2 March 2010
Resolved
Properly repair stbd main diesel engine jacket water temp and lube oil pressure gauges in the pilot house.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 April 2010
Resolved 4 May 2010
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 2 March 2010
Resolved
Remove all flammable liquids fm vessels work shop space prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2010
Communications › Visual Communication › Warning Sign (gangway)
Issued 2 March 2010
Resolved
Properly label emergency exits EMERGENCY EXIT KEEP CLEAR on both sides of hatch and clear stored gear from escape ways.
Condition: Improper/Lack of Maintenance
Due 2 April 2010
Resolved 4 May 2010
Fire Fighting › Combustible Materials › Linings
Issued 2 March 2010
Resolved
Replace trash receptacles with metal cans and lids or receptacles made of non combustible materials.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 April 2010
Resolved 4 May 2010
Construction/Loadline › Structures › Superstructure
Issued 2 March 2010
Resolved
Properly repair pilot house port side door window.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 April 2010
Resolved 4 May 2010
Personnel › Training › First Aid/CPR
Issued 2 March 2010
Resolved
Provide proof of first aid / CPR training for 50% of vsl's crew.
Action required: 705 - Other - as specified
Due 2 April 2010
Resolved 4 May 2010
Stability › Watertight Integrity › General
Issued 13 April 2009
Resolved
Properly repair engine room escape hatch on the main deck currently frozen in the open position.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2009
Resolved 14 April 2009
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 13 April 2009
Resolved
Properly repair vessels' e-lighting.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 14 April 2009
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 13 April 2009
Resolved
Provide two portable flash lights at the vessels operating station and engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 20 April 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 April 2009
Resolved
Remove or properly cap off dead end wires fwd in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 14 April 2009
Operations/Management › Passenger Operations › Safety Orientation
Issued 13 April 2009
Resolved
Properly post vsl's COI and stability letter visible to passengers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 14 April 2009
Lifesaving › Lifebuoys › Serviceable
Issued 13 April 2009
Resolved
Properly repair of replace vessels' aft life ring buoy. Buoy has a large crack in the had plastic shell.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 14 April 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 April 2009
Resolved
Install exhaust lagging on both MDE non water cooled turbo chargers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 14 April 2009
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 May 2008
Resolved
Replace worn retro material
Condition: Improper/Lack of Maintenance
Due 21 May 2008
Resolved 21 May 2008
Resolution: Replaced worn retro material
Communications › Radio Communications › VHF Radiotelephone
Issued 5 May 2008
Resolved
Replace or repair VHF radio
Condition: Improper/Lack of Maintenance
Due 21 May 2008
Resolved 21 May 2008
Resolution: Added new VHF
Engineering › Bilge Water Management System › Strainer
Issued 5 May 2008
Resolved
Replace bilge strainer in engineroom
Condition: Improper/Lack of Maintenance
Due 21 May 2008
Resolved 21 May 2008
Resolution: Replaced bilge strainer.
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 April 2006
Resolved
Maintain log of monthly drills
Due 24 May 2006
Resolved 3 March 2008
Lifesaving › Hand Flares › Storage
Issued 24 April 2006
Resolved
Properly Mark Distress Signal storage container with words "Distress Signals".
Due 24 May 2006
Resolved 5 March 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 April 2006
Resolved
[name withheld] storgae lockers with quantity
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 April 2006
Resolved
Seperate child and adult PFD's in storage lockers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 April 2006
Resolved
Mark vessel name on starboard life ring.
Due 24 May 2006
Resolved 5 March 2008
Documentation › Certificates/Documents › FCC SSL
Issued 24 April 2006
Resolved
Renew all FCC certificates
Due 24 May 2006
Resolved 5 March 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 April 2006
Resolved
Mark starboard hatch and door as Emergency Exit, Keep Clear.
Due 24 May 2006
Resolved 5 March 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 April 2006
Resolved
[name withheld] doors with signs indicating PFD storage is inside space
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2006
Personnel › Training › First Aid/CPR
Issued 24 April 2006
Resolved
Provide valid first aid and CPR cards for 50% of the crew to USCG marine inspector IAW NVIC 1-91
Due 24 May 2006
Resolved 5 March 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 April 2006
Resolved
Renew to original port engine guard on pump clutch
Due 24 May 2006
Resolved 5 March 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 24 April 2006
Resolved
Determine cause of oil leak on stbd main diesel engine turbo drain and reattach exhaust lagging after repair.
Due 24 May 2006
Resolved 5 March 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 April 2006
Resolved
Install watertight battery box
Due 24 May 2006
Resolved 5 March 2008
Stability › Watertight Integrity › General
Issued 24 April 2006
Resolved
Renew top outboard dog on engine room watertight door
Due 24 May 2006
Resolved 5 March 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 24 April 2006
Resolved
Replace missing light cover in shop area next to electrical switch board
Due 24 May 2006
Resolved 5 March 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 April 2006
Resolved
Replace expired items in first aid kit
Due 24 May 2006
Resolved 5 March 2008
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 24 April 2006
Resolved
Obtain copy of current USCG Coast Pilot and Light List for area transited
Due 24 May 2006
Resolved 5 March 2008
Engineering › Bilge Water Management System › Not Operational
Issued 24 April 2006
Resolved
Demonstrate that all bilge pumps and piping are operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2006
Construction/Loadline › Hull › Hull Plating
Issued 24 February 2006
Resolved
C&R 28" x 70" bottom plate in E/R outboard of port engine.
Action required: 705 - Other - as specified
Resolved 14 March 2006
Construction/Loadline › Hull › Hull Plating
Issued 24 February 2006
Resolved
C&R stbd bottom plate below fuel tank.
Action required: 705 - Other - as specified
Resolved 14 March 2006
Construction/Loadline › Structures › Deck Plating
Issued 24 February 2006
Resolved
Replace 3 minor transverse members & 1 longitudinal member above port hull plate insert.
Action required: 705 - Other - as specified
Resolved 14 March 2006
Construction/Loadline › Structures › Deck Plating
Issued 24 February 2006
Resolved
C & R 2 minor transverse members outboard & forward of stbd engine.
Action required: 705 - Other - as specified
Resolved 14 March 2006
Construction/Loadline › Structures › Deck Plating
Issued 24 February 2006
Resolved
C & R 1 & 2 minor transverse members & 1 long. member outboard of fuel tank on stbd side back to E/R WTB & fwd to transverse framing member.
Action required: 705 - Other - as specified
Resolved 14 March 2006
Construction/Loadline › Penetrations › Weld
Issued 24 February 2006
Resolved
Reweld outboard long. member to fwd bulkhead in fwd compartment below wine cellar.
Action required: 705 - Other - as specified
Resolved 14 March 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 February 2006
Resolved
C & R 36" x 15 " of E/R watertight bulkhead.
Action required: 705 - Other - as specified
Resolved 14 March 2006
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 24 February 2006
Resolved
Refurbish both props to repair bent blades & cracks at the end of 2 blades on stbd prop. Provide service reports to show props are balanced.
Action required: 705 - Other - as specified
Resolved 14 March 2006
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 24 February 2006
Resolved
Crop & renew 10 inches of wasted metal from fuel tank on port, fwd, and stbd sides, from deck plate up. Test tank to 5 psi in presence of marine inspector.
Action required: 705 - Other - as specified
Resolved 14 March 2006
Engineering › Bilge Water Management System
Issued 19 April 2004
Resolved
Repair audible alarm for high-level bilge alarm system.
Repair visual indicator for forepeak LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Due 26 April 2004
Resolved 3 May 2004
Lifesaving
Issued 2 February 2000
Resolved
PROVIDE LIFE JACKET PLACARD FOR EACH TYPE OF PFD.
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000
Engineering
Issued 2 February 2000
Resolved
INSTALL FLAME SCREENS (30 X 30 MESH) IN WAY OF THE FUEL TANK VENTS.
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000
Navigation
Issued 2 February 2000
Resolved
PROVIDE CURRENT COAST GUARD LIGHT LIST.
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000
Fire Fighting
Issued 2 February 2000
Resolved
PROVIDE TWO (2) PORTABLE BII FIRE EXTINGUISHERS FOR ENGINE ROOM AND MAIN SALON (HYDROES OUT OF DATE).
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000
Lifesaving
Issued 8 March 1999
Resolved
Forward accommodation space is restricted to passengers unit hatch is operable from the interior.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Lifesaving
Issued 8 March 1999
Resolved
Provide orange smoke signals prior to sailing
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Construction/Loadline
Issued 8 March 1999
Resolved
Install bilge high level alarm by 11MAR
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Lifesaving
Issued 8 March 1999
Resolved
Install reflective tape on all life rings.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Construction/Loadline
Issued 8 March 1999
Resolved
Replace all gaskets on all deck hatches.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Construction/Loadline
Issued 25 February 1998
Resolved
Replace gasket material on forward hold portlights.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Construction/Loadline
Issued 25 February 1998
Resolved
Replace cracked glass located aft of wheel house on both port and starboardsides.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Lifesaving
Issued 6 February 1995
Resolved
Provide 63 additional Type I PFD's. Vessel limited to 92 total adults untilprovided.
Condition: Unknown
Due 6 February 1995
Resolved 6 February 1995
Lifesaving
Issued 6 February 1995
Resolved
Provide one additional orange hand held flare. Vessel not to operate until provided.
Condition: Unknown
Due 6 February 1995
Resolved 6 February 1995
Lifesaving
Issued 6 February 1995
Resolved
Provide operating waterlight for ring buoy. Vessel not to operate until provided.
Condition: Unknown
Due 6 February 1995
Resolved 6 February 1995
Navigation
Issued 6 February 1995
Resolved
Provide copy of NAV rules.
Condition: Unknown
Due 6 February 1995
Resolved 6 February 1995
Fire Fighting
Issued 3 February 1993
Resolved
Prior to vessel carrying passengers have portable fire extinguishers service.
Condition: Unknown
Due 3 March 1993
Resolved 19 February 1993
Lifesaving
Issued 26 February 1992
Resolved
VESSEL NEEDS TO OBTAIN 24 ADULT LIFE PRESERVERS.
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Engineering
Issued 26 February 1992
Resolved
OILY WATER IN BILGES.
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Lifesaving
Issued 19 February 1991
Resolved
provide 3 CG approved PFD's, total persons allowed is reduced to 153 adults_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Documentation
Issued 19 February 1991
Resolved
provide up to date tide tables, tidal current tables, light list and nav rules._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Construction/Loadline
Issued 19 February 1991
Resolved
free up and make operable the escape hatch in the forward corner of engineroom_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Construction/Loadline
Issued 19 February 1991
Resolved
Stencil emergency fuel shut off on main deck_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Lifesaving
Issued 26 February 1990
Resolved
ISSUED CG-835 TO OBTAIN 8 ADULT LIFE PRESERVERS.
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Lifesaving
Issued 22 February 1989
Resolved
PROVIDE 5 CG APPROVED ADULT PFD'S.
Condition: Unknown
Due 22 February 1989
Resolved 22 February 1989
Fire Fighting
Issued 22 February 1989
Resolved
PROVIDE SERVICING FOR CO2 FIRE EXTINGUISHER IN FWD SALON.
Condition: Unknown
Due 22 February 1989
Resolved 22 February 1989
Navigation
Issued 22 February 1989
Resolved
PROVIDE 8 INCH BELL.
Condition: Unknown
Due 22 February 1989
Resolved 22 February 1989
Electrical
Issued 22 February 1989
Resolved
REPLACE WIRE CONNECTORS ON LIGHT FIXTURES IN OVERHEAD IN ENGINEROOM.
Condition: Unknown
Due 22 February 1989
Resolved 22 February 1989
Construction/Loadline
Issued 25 February 1988
Resolved
PROVIDE CAPTURE CHAINS ON ALL FLUSH DECK HATCHES.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Engineering
Issued 25 February 1988
Resolved
PROVIDE 30X30 FLAME SCREENS ON ALL FUEL TANK VENTS.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Construction/Loadline
Issued 25 February 1988
Resolved
PROPERLY STENCIL EMERGENCY FUEL SHUTOFFS AND EMERGENCY ESCAPE HATCHES.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Fire Fighting
Issued 25 February 1988
Resolved
SERVICE PORTABLE CO2 IN FWD WINE CELLAR.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Construction/Loadline
Issued 25 February 1988
Resolved
FREE UP AND LOOSEN DOG ON WT DOOR TO WINE CELLAR.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Construction/Loadline
Issued 25 February 1988
Resolved
FREE UP ABND LOOSEN UP EMERGENCY ESCAPE TO WINE CELLAR
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Lifesaving
Issued 25 February 1988
Resolved
PROVIDE 16 ADULT LIFE JACKETS
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Construction/Loadline
Issued 18 February 1987
Resolved
MAKE WATERTIGHT DOOR TO ENGINE ROOM PROPERLY FIT.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Lifesaving
Issued 18 February 1987
Resolved
PROVIDE 3 ADDITIONAL PERSONAL FLOTATION DEVICES.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Unknown
Issued 11 May 1984
Resolved
STENCIL WATERTIGHT DOORS LOCATED BELOW DECKS BULKHEADS IN 1" LETTERS"WATER-TIGHT DOOR, CLOSE IN EMERGENCY" 46 CFR 185.30-25
Condition: Unknown
Due 11 May 1984
Resolved 11 May 1984
Unknown
Issued 11 May 1984
Resolved
STENCIL EMER.ESCAPE HATCHES EXTERIOR"EMERGENCY ESCAPE, KEEP CLEAR" (1" - LETTERS) AND THE INTERIOR"EMERGENCY ESCAPE HATCH" 1" LETTERS 46CFR185.30-15
Condition: Unknown
Due 11 May 1984
Resolved 11 May 1984
Unknown
Issued 11 May 1984
Resolved
PLACE 2 HAND LANTERNS ON BOARD 46 CFR 184.30-1
Condition: Unknown
Due 11 May 1984
Resolved 11 May 1984
Unknown
Issued 11 May 1984
Resolved
PLACE ON AUTOMATICALLY OPERATED EMERGENCY LIGHT IN THE FWD. WINE CELLAR PASSENGER SPACE. 46 CFR 184.30-5(A)+(B) STENCIL SAME WITH 1" E.
Condition: Unknown
Due 11 May 1984
Resolved 11 May 1984