Inspection history · 19
15 June 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8404951
31 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8334164
3 July 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8203145
23 April 2024
Plan Review "T" Boat · Simplified Stability Test · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7900418
3 April 2024
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886452
20 March 2024
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7872854
29 November 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7831316
12 July 2022
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7498650
20 June 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7483881
18 November 2021
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7354120
23 November 2020
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7100297
27 June 2020
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6990600
19 March 2020
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6929889
5 November 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6850445
26 November 2018
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6587011
22 March 2018
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6373055
2 November 2017
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6296136
13 December 2016
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6122137
15 March 2016
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5832887
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 3 July 2025
Resolved
vessel did not have employee assistance program available
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 March 2026
Resolution: employee assistance program on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 July 2025
Resolved
FCC Station authorization cert missing
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 July 2025
Resolution: operator sent in photos of station authorization
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 July 2025
Resolved
Vessel log missing
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 March 2026
Resolution: Logbook installed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 3 July 2025
Resolved
Placard for garbage.oil pollution missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 March 2026
Resolution: Placard for garbage installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 July 2025
Resolved
First aid kit medicine expired
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 March 2026
Resolution: First aid kit medicine on board
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 July 2025
Resolved
Flares expired
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2025
Resolution: operator purchased and got flares on the vessel prior to us leaving
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 July 2025
Resolved
Portable lights at operating station missing
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 March 2026
Resolution: Portable lights installed
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 July 2025
Resolved
EPIRB registration missing
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 July 2025
Resolution: operator sent photo of EPPIRB registration
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 July 2025
Resolved
Fire buckets missing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2025
Resolution: fire buckets placed on board prior to us leaving
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2025
Resolved
Remote fuel shut-off not labled
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 March 2026
Resolution: Remote fuel shut-off labeled
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 April 2024
Resolved
VESSEL IS OUTFITTED WITH A LITHIUM-ION BATTERY AND CHARGING SYSTEM, WHICH HAS NOT BEEN EVALUATED OR APPROVED. SUBMIT LITHIUM-ION SYSTEM DRAWINGS AND SPECIFICATIONS TO MARINE SAFETY CENTER (MSC) ELECTRICAL BRANCH FOR REVIEW WITHIN 14 DAYS. CONTINUE TO KEEP SYSTEM DE-ENERGIZED AND DISABLED / TAGGED-OUT UNTIL ACCEPTABILITY IS DETERMINED BY OCMI.
46CFR183.100/115
CG-ENG-PL 02-19
26 June 2024 - Update: Li-Ion batteries confirmed removed. MSC plan submission & approval of charging system (solar & wind) required prior to use with ANY battery type (AGM or Lead-Acid).
Action required: 705 - Other - as specified
Resolved 3 December 2024
Resolution: put def as special note since the operator does not intend on submitting to MSC
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 April 2024
Resolved
VESSEL DOES NOT HOLD A STABILITY LETTER, NOR RECORD OF SATISFACTORILY CONDUCTING A SIMPLIFIED STABILITY TEST (SST). VESSEL IS TO PREPARE FOR AND SCHEDULE TO CONDUCT AN ACCEPTABLE STABILITY STUDY / SST WITH USCG M.I. ATTENDANCE WITHIN 30 DAYS.
46CFR178.210
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 June 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 April 2024
Resolved
VESSEL IS OUTFITTED WITH LITHIUM-ION BATTERIES AND CHARGING SYSTEM, WHICH HAS NOT BEEN EVALUATED OR APPROVED. SUBMIT LITHIUM-ION SYSTEM DRAWINGS AND SPECIFICATIONS TO MARINE SAFETY CENTER (MSC) ELECTRICAL BRANCH FOR REVIEW --OR-- REMOVE SUBJECT LITHIUM-ION BATTERIES FROM THE VESSEL, PRIOR TO THE CARRIAGE OF ANY PASSENGERS.
46CFR183.100/115
CG-ENG-PL 02-19
PLACED ON SEC NY COMCEN / VTS OP CONTROL TRACKER 5/8/24.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2024
Resolution: VERIFIED LI-ION BATTERIES HAVE BEEN REMOVED FROM VSL.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 April 2024
Resolved
VESSEL IS REQUIRED OPERABLE VHF RADIO. UNABLE TO PERFORM RADIO CHECK ON INSTALLED VHF. REPAIR / REPLACE.
47CFR80
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 April 2024
Resolved
VESSEL REQUIRED NAVIGATIONAL LIGHTS PER NAVIGATIONAL RULES. STERN LIGHT WAS INOPERABLE.
REPAIR / REPLACE PRIOR TO NIGHT-TIME AND/OR REDUCED VISIBILITY OPS.
33CFR83.20
Action required: 705 - Other - as specified
Resolved 11 April 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 April 2024
Resolved
TO OPERATE BEYONG 3 MILES FROM LAND, VESSEL IS REQURIED CAT 1 EPIRB. CURRENT VSL EPIRB AND HRU WERE NOT MOUNTED TO BE FLOAT FREE. INSTALL PROPERLY.
46CFR180.64
OPS LIMITED TO WITHIN 3 MI. OF SHORE.
Action required: 705 - Other - as specified
Resolved 11 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 April 2024
Resolved
VESSEL LIFE-FLOAT (08 PERSON) IS REQURIED TO BE ARRANGED WITH PAINTER AND WEAK-LINK IN FLOAT FREE MANNER AND EQUIPPED WITH 4FT PADDLE AND WATERLIGHT. AT TIME OF INSPECTION, LF WAS LASHED DOWN, NOT CONNECTED TO PAINTER, MISSING PADDLE, AND WATERLIGHT WAS INOP. PROVIDE REQURIED EQUIPMENT AND ARRANGE PROPERLY.
46CFR180.205
46CFR180.175
OPS LIMITED TO WITHIN 1NM OF SHORE.
Action required: 705 - Other - as specified
Resolved 6 May 2024
Resolution: O/O PROVIDED EVIDENCE OF APPROPRIATE WEAK-LINK (B.S) AND ARRANGEMENT / EQUIPPING OF L.F.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 April 2024
Resolved
PROTECTIVE GUARDS & INSULATION ARE REQURIED ON PIPING, ETC. OVER 150 degF. PROVIDE INSULATION / LAGGING ON MDE EXHAUST ELBOW.
46CFR176.402
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2024
Resolved
LITHIUM ION BATTERY INSTALLATIONS REQUIRE ASSESSMENT PER CG-ENG-POLICY LETTER 02-19 OR SUBMITTED USCG APPROVED PLANS. PROVIDE ASSOCIATED DOCUMENTATION OF INSTALL OR DISCONNECT BATTERIES WITH VERIFIABLE MEANS.
701-C - O/O DISCONNECTED / DISABLED BATTERY INSTALL (OPENED / TRIPPED BREAKERS, POWER SWITCH SECURED), TAMPER SEALED CABINET, ADDED ENTRY TO REMAIN OFF & CHECK IN VSL LOG, AND POSTED WARNING TO PAX / CREW NOT TO ENERGIZE OR TAMPER WITH.
705-C - SEE MISLE ACTIVITY NO. 7900418 FOR SEPARATE CG-835 ISSUING 14 DAYS TO SUBMIT PLANS TO MSC
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2024
Resolution: 705-C - SEE MISLE ACTIVITY NO. 7900418 FOR SEPARATE CG-835 ISSUING 14 DAYS TO SUBMIT PLANS TO MSC
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 April 2024
Resolved
PROVIDE FCC STATION LICENSE AND CURRENT VALID C.O.D. POSTED.
47CFR80
46CFR67
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 November 2023
Resolved
"Your vessel must undergo an annual inspection w/in 3 months before or after each anniversary date." Vessel missed its annual inspection date and must apply for a new COI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2024
Resolution: Received Valid COI
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 November 2021
Resolved
Prove proper operation of VHF DSC functionality.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2022
Resolution: MI witnessed satisfactory operation of vessel's VHF.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 November 2020
Resolved
Bilge Pump switch inoperable. Repair and replace
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2020
Resolved 4 December 2020
Resolution: Bilge pump switch replaced and operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2020
Resolved
Repair fuel hose line with solid copper or proper hose in kind.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 4 December 2020
Resolution: Fuel hose line replaced with proper hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 November 2020
Resolved
Properly mount oil pressure gauge at operating station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 4 December 2020
Resolution: Vessel master properly and securely mounted the oil pressure guage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2020
Resolved
Properly provide Engine Room ventiliation covers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 4 December 2020
Resolution: Engine Room ventiliation covers replaced with proper equipment.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 November 2020
Resolved
Bilge alarm inoperable. Repair and replace.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2020
Resolved 4 December 2020
Resolution: High water alarms replaced and operational.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 November 2017
Resolved
Provide a fire servicing report for the fixed system and extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 November 2017
Resolved
Provide Alchol testing equipment for vessel to meet the 2 hour requirement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Lifesaving › Lifebuoys › Serviceable
Issued 2 November 2017
Resolved
Life Ring Buoy hand line is dry rotted and needs to be replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Lifesaving › Lifefloat › Painter
Issued 2 November 2017
Resolved
Life FLoat sea painter is dry rotted and needs to be replaced/renewed. 100' in the can.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017