MAURY USCG vessel records Sign in
← All vessels

ONEGO PRIDE

ONEGO PRIDE is a 1984 freight ship. The Coast Guard has recorded 28 inspections since 1986, most recently in August 2006, along with 21 deficiencies and 6 operational controls.

Records from 1986 to 2006. Most recent: operational control imposed, 12 August 2006.

Built
1984
Last inspected
12 August 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8002822 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
229572
Flag
NORWAY
—
Maury page id
psix-229572

Inspections, by type

…with no type recorded21
Years with a record 9 calendar years (1986–2006)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9600 - Dead Weight, Ton
12630 - Displacement, Ton
3287 - Convention (Subpart B), Net Ton
5941 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

12 August 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2747996
7 August 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2739140
16 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2650486
14 May 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2744889
6 April 2006 ISPS III Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2618515
10 December 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2549182
5 October 2005 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2508237
25 August 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2474904
8 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2419279
14 January 2005 ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2274122
21 August 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 474825
24 July 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 698415
14 July 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 380611
6 March 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 649083
20 February 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 184376
20 February 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1158085
4 June 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 450993
4 June 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1367067
29 April 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 366384
7 April 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 367367
16 February 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 490527
29 June 1993 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 506038
21 March 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 481717
11 June 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 337616
11 March 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 321863
3 September 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 462074
23 May 1986 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 308953
16 May 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1297423

Deficiency record · 21

Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 16 May 2006 Resolved
While at anchorage the M/V ONEGO PRIDE discovered that they had an engine failure. Upon futher investigation it was determined to be a leaking head of the #6 cylinder. Issued COTP Order 038-06 requiring vessel to maintain a two tug escort during the inbound transit of the Savannah River.
Action required: 705 - Other - as specified
Due 16 May 2006
Resolved 16 May 2006
Resolution: Recieved class report attesting to repairs made to the #6 cylinder head.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 April 2006 Resolved
fie control plan indicates a class "A" door between galley and crew mess door has been cut in half to create pass through. provide class "A" door as per SOLAS
Condition: Placed in Improper Service
Due 7 May 2006
Resolved 17 May 2006
Resolution: The class "A" door has been repaired to the Satisfaction of Class.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 6 April 2006 Resolved
vessel has a crew of 15 members and is on a voyage of more than 3 days. 1 crew member is currently living in the hospital space and a laundry washer has been installed. crew member must be relocated and laundry must be removed prior to departing.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2006
Resolution: hospital space is now free of any crew members and the washing machine was reinstalled and removed.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 6 April 2006 Resolved
SOLAS training manual only supplied in crew mess 2nd copy needs to be provided for officer mess.
Condition: Improper/Lack of Maintenance
Due 7 May 2006
Resolved 7 April 2006
Resolution: training manual was copied and placed in officers mess
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 6 April 2006 Resolved
during operational test of emergency fire pump room filled with exhust gasses leak discovered at head and exust pipe correct leak.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 17 May 2006
Resolution: The exhaust gas piping of the emergency fire pump has been replaced and class examined the piping and found no leaks.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 6 April 2006 Resolved
machinery guard for emergency fire pump fell off during operational test. reinstall guard.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 17 May 2006
Resolution: The machinery guard for the emergency fire pump has been fitted to the satisfaction of class
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 6 April 2006 Resolved
FWD Store room in Bosun store being used as paint locker door does not secure and bulkhead has openings. administration needs to attend to appropriate fire extinguishing arrangements.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2006
Resolved 7 August 2006
Resolution: Attended vessel to complete inspection of paint locker. Class Survey was posted in paint locker attesting to proper repairs and visual inspection of space was satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 October 2005 Resolved
Engine room spaces not kept free of excess oil and debris.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 December 2005
Resolution: Inspected Engineering spaces and found them in satisfactory condition.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 January 2005 Resolved
During the inspection of the oily water separator (ows), oil and water well in excess of 15ppm was found in the overboard piping after the oil content sensor and three way valve. The PSCO believes that the system is not operating nor installed as designed. A bypass line was found welded to the ows filter output line which bypassed the ows 15ppm sensor equipment. The vessel is to prove proper opera
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 15 January 2005
Resolution: Oily water separator (OWS) by-pass piping was removed, all OWS overboard piping was cleaned and inspected, the OWS was operationally tested with satisfactory results and the current piping arrangement is in accordance with the approved plans.
Documentation
Issued 14 July 1995 Resolved
PRIOR TO DEPARTURE AND PRIOR TO BUNKERING IN THE PORT OF HOUSTON, PROVIDE ADMINISTRATION APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP)._x001C_ _x001C_ MARPOL ANNEX I REG.26 & 33 CFR 156.29
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Documentation
Issued 14 July 1995 Resolved
PROVIDE CYPRUS ADMINISTRATION CERTIFICATES FO COMPETENCY OR ACCEPTANCE OF NATIONAL CERTIFICATES FOR ALL OFFICERS._x001C_ _x001C_ STCW ART.VI
Condition: Unknown
Due 23 August 1995
Resolved 23 August 1995
Fire Fighting
Issued 14 July 1995 Resolved
REPLACE FIRE HYDRANT HANDLE ON HYDRANT LOCATED ON STBD SIDE AFT OF #3 CRANE.
Condition: Unknown
Due 23 August 1995
Resolved 23 August 1995
Navigation
Issued 14 July 1995 Resolved
PROVIDE MANEUVERING DIAGRAM INFORMATION ON BRIDGE (MISSING BALLAST CONDITION)._x001C_ _x001C_ 33 CFR 164.35(g)(6)
Condition: Unknown
Due 23 August 1995
Resolved 23 August 1995
Fire Fighting
Issued 14 July 1995 Resolved
PROVIDE ADEQUATE OPERATION INSTRUCTIONS AT CO2 CONTROL STATION FOR FIRE IN #1 HOLD, #2 HOLD, AND ENGINE ROOM. LABEL BOTTLES AS NECESSARY._x001C_ _x001C_ SOLAS II-2/REG.5
Condition: Unknown
Due 23 August 1995
Resolved 23 August 1995
Accommodation/Occupational Safety
Issued 4 June 1994 Resolved
PROVIDE AND INSTALL A LOCKING DEVICE FOR OILY WATER SEPERATOR OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 4 June 1994
Resolved 4 June 1994
Navigation
Issued 4 June 1994 Resolved
PROVIDE AND INSTALL SAFTEY NUTS/PINS/COTTER KEYS IN STEERING GEAR LINKAGE.
Condition: Unknown
Due 4 June 1994
Resolved 4 June 1994
Lifesaving
Issued 4 June 1994 Resolved
PROVIDE AND MAINTAIN AN ON BOARD MAINTENANCE MANUAL FOR LIFE SAVING APPLIACNE AS PER SOLAS III/52
Condition: Unknown
Due 4 June 1994
Resolved 4 June 1994
Lifesaving
Issued 4 June 1994 Resolved
PROVIDE AND INSTALL LIFE SAVING PLACARDS NEAR LIFE RAFTS.
Condition: Unknown
Due 4 June 1994
Resolved 4 June 1994
Navigation
Issued 11 March 1988 Resolved
BRITISH ADMIRALTY COAST PILOT VOLUME 8, 1975ED., FOREIGN EQUIVALENT TO U.S.COAST PILOT VOL. 7, ONBOARD BUT NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33. BRITISH ADMIRALTY COAST PILOT WAS MISSING SUPPLEMENT 7.
Condition: Unknown
Due 15 March 1988
Resolved 11 March 1988
Navigation
Issued 11 March 1988 Resolved
CHART 18749, NECESSARY FOR SAFE NAVIGATION INTO THE PORT OF LONG BEACH, OR ANY FOREIGN EQUIVALENT NOT ONBOARD AS REQUIRED BY 33CFR164.33.
Condition: Unknown
Due 15 March 1988
Resolved 11 March 1988
Navigation
Issued 11 March 1988 Resolved
CHART 18751, NECESSARY FOR SAFE NAVIGATION INTO THE PORT OF LONG BEACH, OR ANY FOREIGN EQUIVALENT NOT ONBOARD AS REQUIRED BY 33CFR164.33.
Condition: Unknown
Due 15 March 1988
Resolved 11 March 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.