Records from 1984 to 2008. Most recent: inspection, 3 December 2008.
Inspection history · 88
3 December 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3373363
1 November 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3355492
28 October 2008
Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3351115
27 September 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3333653
23 September 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3331262
6 September 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3318998
5 September 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3318641
30 June 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3252476
24 June 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3246891
24 June 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3453806
18 June 2008
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3240396
17 December 2007
STCW 95 Exam · MARPOL Annex V Examination · ILO-147 Exam · Ballast Water Examination · MARPOL Annex I Examination · ISM Exam · ISPS III Exam · Loadline Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3117220
25 June 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2973146
8 June 2007
MARPOL Annex I Examination · Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2955088
27 May 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2660498
27 May 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2660546
24 May 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2657891
21 February 2006
NPV Safety Exam · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2589264
6 February 2006
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2580065
14 September 2005
NPV Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2488459
26 August 2005
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2475161
8 August 2005
MARPOL Annex V Examination · Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex I Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2455919
6 July 2005
Random ISPS/MTSA/PSC · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2417316
8 April 2005
ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2329301
7 April 2005
ISPS II Exam · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2328830
15 March 2005
PII Safety Exam · ISPS II Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2310328
18 February 2005
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2295607
18 February 2005
Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 2296443
18 February 2005
ISPS I Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2366048
15 February 2005
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2293129
26 January 2005
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2281303
26 January 2005
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2281348
1 December 2004
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2253250
21 October 2004
ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2225584
27 July 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2147087
1 July 2004
ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2117180
27 April 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2058015
22 April 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2050273
13 December 2003
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1964548
24 October 2003
MARPOL Annex V Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1935089
22 September 2003
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1910359
13 January 2003
In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1740514
18 June 2002
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1632400
7 June 2002
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1629109
4 June 2002
Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1626238
13 April 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 289030
13 February 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 287132
9 September 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 281887
26 January 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 274054
31 August 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 432199
23 January 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 424762
11 September 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 420313
23 January 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 412141
9 January 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 411492
16 May 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 191435
16 May 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 756474
10 May 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 403474
25 March 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 645813
16 January 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 399428
9 January 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 399181
21 March 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 389190
26 January 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 387167
19 January 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 386967
22 October 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 384177
30 December 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 373826
20 October 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 464863
2 August 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 505980
19 May 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 366972
13 March 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 365179
11 January 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 363641
4 November 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 362176
9 July 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 359425
27 March 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 357181
1 February 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 356002
23 June 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 351522
25 April 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 471984
11 February 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 348735
6 October 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 346272
18 January 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 341394
14 February 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 335329
13 February 1989
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 328472
17 September 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 470804
14 February 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 321201
8 August 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 476428
11 February 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 314276
8 July 1985
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 303138
21 January 1985
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 505286
14 June 1984
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 296694
Engineering › Freshwater System (air cooling) › Piping
Issued 28 October 2008
Resolved
There is a temporary band clamp on the salt water cooling intake pipe to the forward scavenger air cooler for the main engine. Also noted, corrosion and crystallization with a catch bucket located on the same pipe system.
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 1 November 2008
Resolution: Received Class report satisfying requirements.
Operations/Management › Cargo Transfer/Lightering › Pre-transfer Inspection
Issued 28 October 2008
Resolved
A static liquid pressure test has not been conducted to the bunker lines in accordance with 33 CFR 156.170. The vessel is prohibited from bunkering in US waters until the required test is conducted and documented.
Action required: 705 - Other - as specified
Resolved 3 December 2008
Resolution: Received proper documentation satisfying requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 September 2008
Resolved
One of two of the vessel's radars is inoperative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2008
Resolution: Recieved tech report rectifiying discrepancy.
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 September 2008
Resolved
The vessel was granted a deviation to enter The Port of New Orleans with an inoperable X-Band Radar.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2008
Resolved 12 September 2008
Resolution: Received Tech Report from Sperry Marine Service Net satisfying the requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 29 June 2008
Resolved
Main engine turbo charger bearing failure.
Action required: 705 - Other - as specified
Resolved 29 June 2008
Resolution: Received class report from Lloyd’s Registry satisfying the requirements.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 8 June 2007
Resolved
The vessel's Engine Room had several rubber and soft hoses; most notably one rubber hose from the lube oil tank to the Cargo Generator Fuel Tank stretching more than 30 ft and a soft hose similar to a fire hose from the workshop sink running between the Lube Oil & Sludge Tanks and into the bilge. Remove or install hard piping in these locations.
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 20 June 2007
Resolution: The rubber hose at the cargo generator fuel tank was removed. The rubber hose from the workshop sink to the lube and sludge oil tank has been replaced by hard piping.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 8 June 2007
Resolved
A detailed diagram of the OWS Piping has not been approved by the vessels classification society or flag state since modifying it in dry-dock. Obtain an approved diagram.
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 20 June 2007
Resolution: The recently installed testing line before the over board valve has been permanently removed. The OWS drawing of the OWS Piping System has been endorsed for approval and posted by the OWS.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 June 2007
Resolved
The ship's Second Officer's Flag State Endorsement number does not correspond to his new National License. Have the Second Officer submit a new application to the Bahamas and obtain a confirmation receipt.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 20 June 2007
Resolution: the ship''s second officer''s Bahamian license has been verified and the endorsement number matches with his Polish national license.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 May 2006
Resolved
Measures for the containment of smoke and fire violated: Three Class "A" doors in Class "A" boundaries/divisions i vicinity of frames 12-15, port side main deck, fitted with magnetic holdback devices on lower edge of doors. These devices are not connected to the ship's central holdback release system
Action required: 705 - Other - as specified
Resolved 27 May 2006
Resolution: Vessel removed holdback devices; to the satisfaction of the attending Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 15 March 2005
Resolved
Toilet in hospital not functioning properly.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 7 April 2005
Resolution: Conducted deficiency check and the toilet in the hospital was observed to be functioning properly.
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 15 March 2005
Resolved
Hot fresh water not provided in hospital washroom.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 7 April 2005
Resolution: Conducted deficiency check and verified existence of hot fresh water in hospital washroom.
Construction/Loadline › Structures › Scuttle
Issued 1 July 2004
Resolved
Hatch and combing wasted and inset by unknown source
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 July 2004
Resolution: Corrected.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 1 July 2004
Resolved
Master failed to properly maintain and be familiar with the ISPS and ISM Codes.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 July 2004
Resolution: Corrected.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 1 July 2004
Resolved
Numerous fuel and lube oil leaks in the engine room. Excessive hydraulic oil in the steering gear compartment. Fuel leak on the emergency fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2004
Resolution: Corrected.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 1 July 2004
Resolved
No records/anaylsis of non-conformities.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 July 2004
Resolution: Corrected.
Documentation › Safety/Response Plans/Programs
Issued 24 October 2003
Resolved
Fire conrtol plan was unreadable. LEGACY COMPONENT DESC: Fire Control Plans
Due 21 November 2003
Resolved 13 December 2003
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 13 January 2003
Resolved
Make repairs to the inoperable cylinder of the main engine to the satisfaction of Class/Administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2003
Resolution: Received Class report attesting to necessary replacement and satisfactory repairs of the inoperable cylinder of the main engine.
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 June 2002
Resolved
CURRENT COAST PILOT PUBLICATION MISSING
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2002
Resolution: CURRENT COAST PILOT PUBLICATION ON BOARD
Navigation › Piloting/Steering
Issued 4 June 2002
Resolved
BLOCK DIAGRAM FOR REMOTE STEERING GEAR CHANGEOVER PROCEDURES NOT PERMENANTLY DISPLAYED ON BRIDGE OR IN STEERING GEAR ROOM
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 7 June 2002
Resolution: MSO JAX VERIFIED THAT VESSEL NOW HAS BLOCK DIAGRAM AND INSTRUCTIONS FOR REMOTE STEERING GEAR PROCEDURES.
Documentation › Logs/Records
Issued 4 June 2002
Resolved
PREARRIVAL TEST PER 33CFR 164.25 NOT LOGGED IN SHIP'S LOGBOOK LEGACY COMPONENT DESC: Logbook (official)
Action required: 15 - Rectify deficiencies by next port
Resolved 7 June 2002
Resolution: MSO JACKSONVILLE VERIFIED PRE-ARR TEST PRIOR TO JAX WAS LOGGED IN SHIP''S LOGBOOK.
Pollution Prevention/Response › Prevention Equipment
Issued 4 June 2002
Resolved
SOPEP NOT ON BOARD. CLASS SOCIETY TO PROVIDE DOCUMENTATION THAT APPLICATION HAS BEEN MADE TO FLAG STATE OR CLASS FOR APPROVED SOPEP. FAX INFO TO MSO-TAMPA.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2002
Resolution: FAX RECIEVED FROM CLASS THAT SOPEP MANUAL SUBMITTED TO CLASS FOR APPROVAL.
Documentation › Certificates/Documents
Issued 4 June 2002
Resolved
CLASS SOCIETY TO ADDRESS VALIDITY OF IOPP SUPPLEMENT DATED 1997. ACTUAL CERTIFICATE ISSUED 21DEC2001. BOX CHECKED ON SUPPLEMENT REGARDING SOPEP, BUT SOPEP NOT ON BOARD. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2002
Resolution: RESOLVED BY FAX FROM CLASS
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 4 June 2002
Resolved
PROVIDE CURRENT NOTICE TO MARINERS CORRECTIONS FOR TAMPA BAY CHARTS (33CFR 164.33)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2002
Resolution: CORRECTED
Construction/Loadline
Issued 13 February 2001
Resolved
PRIOR TO 13MAR01 REPLACE MISSING DOG AND GASKET TO WATERTIGHT DOOR LEADING TO AFT STEERING COMPARTMENT.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Fire Fighting
Issued 13 February 2001
Resolved
PRIOR TO 13MAR01 REPAIR EXHAUST LEAK ON EMERGENCY FIRE PUMP ENGINE AND PROVIDE ADEQUATE VENTILATION FOR COMPARTMENT.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Lifesaving
Issued 9 January 1998
Resolved
REPAIR OR REPLACE SELF IGNITING LIGHT JUST AFT ON STARBOARD LIFEBOAT DECK.
Condition: Unknown
Due 23 January 1998
Resolved 23 January 1998
Lifesaving
Issued 9 January 1998
Resolved
PLACE RETRO TAPE ON PORT AND STARBOARD LIFEBOATS BOTTOM AND SIDE RAILS AS PER SOLAS TRAINING MANUAL.
Condition: Unknown
Due 23 January 1998
Resolved 23 January 1998
Navigation
Issued 9 January 1997
Resolved
PRIOR TO DEPARTURE OF NEXT U.S. PORT PROVIDE TECH REP REPORT CONFIRMING PROPER OPERATION OF TWO MARINE RADARS.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Fire Fighting
Issued 9 January 1997
Resolved
PRIOR TO 10FEB97 REPAIR SMALL CRACK IN FIRE MAIN PIPING NEXT TO FIRE PUMP IN ENGINE ROOM. CRACK DID NOT AFFECT PRESSURE.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Engineering
Issued 9 January 1997
Resolved
PIC OF EACH COMPLETED OPERATION ENTERED IN THE OIL RECORD BOOK FAILED TO SIGN EACH ENTRY.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Navigation
Issued 9 January 1997
Resolved
WARNING STATEMENT MISSING FROM MANEUVERING FACT SHEET.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Accommodation/Occupational Safety
Issued 9 January 1997
Resolved
PRIOR TO 10FEB97 "HARD PIPE" A/C COOLING WATER SUPPLY LINE (CURRENTLY HOSE).
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Fire Fighting
Issued 9 January 1997
Resolved
PRIOR TO 10FEB97 FINISH WELDING WATER TIGHT BULKHEAD AT PIPING PENETRATION LOCATED AT ENTRY TO THE EMERGENCY FIRE PUMP SPACE. (NEW PIPING INSTALED DURING DDX, PENETRATION WAS NOT COMPLETLY WELDED).
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Fire Fighting
Issued 19 January 1996
Resolved
Missing int'l shore connection. Provide prior to return to U.S. waters.
Condition: Unknown
Due 26 January 1996
Resolved 26 January 1996
Lifesaving
Issued 19 January 1996
Resolved
Correct improper storage of paint and other flammable materials. remove flammable materials from after steering prior to return to U.S. waters.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Navigation
Issued 13 March 1994
Resolved
SUBJ VESSEL'S COAST PILOT #5 WAS OUTDATED.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Navigation
Issued 8 July 1985
Resolved
VSL BOARDED PORT OF TOLEDO BY MSO BOARDING PARTY VSL DID NOT HAVE ON BOARD LIGHT LIST VOLUME 4 ONBOARD
Condition: Unknown
Due 8 July 1985
Resolved 8 July 1985
Navigation
Issued 8 July 1985
Resolved
VSL BOARDED PORT OF TOLEDO VSL DID NOT HAVE ON BOARD U.S.COAST PILOT #6
Condition: Unknown
Due 8 July 1985
Resolved 8 July 1985
Navigation
Issued 8 July 1985
Resolved
VSL BOARDED PORT OF TOLEDO BY MSO BOARDING PARTY THE VSL DID NOT HAVE THE FOLLOWING CHARTS ON BOARD 14847,14820,14768
Condition: Unknown
Due 8 July 1985
Resolved 8 July 1985
Unknown
Issued 14 June 1984
Resolved
40 CFR 140.3(D) THE EFFLUENT SHALL NOT HAVE A FECAL COLIFORM BACTERIAL COUNT OF GREATER THAN 200 PER 100 MILLILTERS NOR SUSPENDED SOLIDS GREATER THAN 150 MG/L IN A TYPE II MSD SYSTEM.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984