Records from 1985 to 2003. Most recent: inspection, 30 April 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
30 April 2003
Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 1765286
26 February 2002
Re-Inspection
Physical examination · Activities Europe · Activity 1492961
31 July 2001
Deficiency Check
Physical examination · Activities Europe · Activity 1069906
22 July 2001
Hull Examination
Physical examination · Activities Europe · Activity 1370321
15 May 2001
Deficiency Check
Physical examination · Activities Europe · Activity 1063528
19 March 2001
Deficiency Check
Physical examination · Activities Europe · Activity 1059761
20 January 2001
COI Inspection
Physical examination · Activities Europe · Activity 1425064
28 August 2000
Administrative
Administrative · Activities Europe · Activity 823841
26 January 2000
Re-Inspection
Physical examination · Activities Europe · Activity 1433602
23 January 1999
COI Inspection
Physical examination · Activities Europe · Activity 1368972
2 March 1998
Re-Inspection
Physical examination · Activities Europe · Activity 1120300
19 January 1997
COI Inspection
Physical examination · Activities Europe · Activity 1098471
1 May 1996
Hull Examination · COI Inspection
Physical examination · Activities Europe · Activity 1082013
30 March 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1078964
18 March 1996
Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 884613
13 February 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 46054
13 February 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 211822
20 January 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424038
13 December 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460678
9 December 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362887
3 August 1993
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154596
22 April 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1150563
19 October 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1256852
20 July 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1260027
16 March 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 953180
5 February 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955673
20 September 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944034
20 February 1991
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236761
22 June 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220044
10 March 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919299
21 November 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 227120
4 April 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040637
11 February 1989
Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1035090
10 May 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040093
17 February 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991965
22 October 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1017993
24 July 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024480
29 April 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019988
29 April 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1324551
7 February 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997583
29 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981879
7 March 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1287612
Electrical › Lighting (emergency)
Issued 30 April 2003
Resolved
Install emergency lighting in both emergency escape trunks in engine room. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 30 May 2003
Resolved 17 May 2003
Resolution: Received attestation from [name withheld], master, for corrective action.
Pollution Prevention/Response › Prevention Equipment
Issued 30 April 2003
Resolved
Repair/replace Oily Water Separator. Vessel my not discharge oily wastewater overboard and must retain all oil slops aboard to be discharged to shore until the OWS is installed and operational. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Due 30 May 2003
Resolved 21 June 2003
Resolution: Received attestation from [name withheld], master, for corrective action.
Navigation
Issued 30 April 2003
Resolved
Ensure magnectic compass is swung and new deviation card is complete
Condition: Improper/Lack of Maintenance
Due 30 May 2003
Resolved 4 June 2003
Resolution: Received attestation from [name withheld], master, for corrective action.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 30 April 2003
Resolved
Ensure manual pulls on fixed CO2 system are marked as per instructions. LEGACY COMPONENT DESC: Operating Controls
Condition: Placed in Improper Service
Due 30 May 2003
Resolved 5 June 2003
Resolution: Received attestation from [name withheld], master, for corrective action.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 30 April 2003
Resolved
Ensure all portable fire extinguishers are with in the hydro test dates.
Condition: Improper/Lack of Maintenance
Due 30 May 2003
Resolved 22 June 2003
Resolution: Received attestation from [name withheld], master, for corrective action.
Pollution Prevention/Response › Prevention Equipment
Issued 30 April 2003
Resolved
Ensure vessel has MARPOL standard discharge connection (MARPOL I) LEGACY COMPONENT DESC: Standard Discharge Connection
Condition: Unknown
Due 30 May 2003
Resolved 12 May 2003
Resolution: Received attestation from [name withheld], master, for corrective action.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 30 April 2003
Resolved
Licensed mate had tonnage for 500 gross tons (ITC). Vessel is 863 gross tons (ITC).
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2003
Resolved 30 April 2003
Resolution: New license mate came aboard.
Deck/Cargo
Issued 30 April 2003
Resolved
Ensure all pressure relief valves for the ships bulk cargo tanks are tested and are with in required relief settings.
Due 30 May 2003
Resolved 12 May 2003
Resolution: Received attestation from [name withheld], master, for corrective action.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 30 April 2003
Resolved
Repair/replace dryer vent- flex hose LEGACY COMPONENT DESC: Laundry
Due 30 May 2003
Resolved 23 May 2003
Resolution: Received attestation from [name withheld], master, for corrective action.
Engineering › Compressed Air System (control)
Issued 30 April 2003
Resolved
Ensure all pressure relief valves for the ships service air tanks are tested and are with in the required relief settings. LEGACY COMPONENT DESC: Valve
Due 30 May 2003
Resolved 12 May 2003
Resolution: Received attestation from [name withheld], master, for corrective action.
Engineering › Generator (propulsion-electric)
Issued 30 April 2003
Resolved
Repair/replace stbd aft generator synchro motor.
Due 30 May 2003
Resolved 12 May 2003
Resolution: Received attestation from [name withheld], master, for corrective action.
Accommodation/Occupational Safety
Issued 30 April 2003
Resolved
Stencil emergency escape hatches - EMERGENCY ESCAPE, KEEP CLEAR.
Due 30 May 2003
Resolved 6 May 2003
Resolution: Received attestation from [name withheld], master, for corrective action.
Accommodation/Occupational Safety
Issued 12 March 2002
Resolved
Replace rotten olywood overhead in Galley.
Due 15 March 2002
Resolved 30 April 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 12 March 2002
Resolved
Complete servicing of Fixed CO2 system in presence of an ABS surveyor and provide service report to USCG.
Action required: 705 - Other - as specified
Due 15 March 2002
Resolved 12 March 2002
Unknown
Issued 22 July 2001
Resolved
Conduct installation test of work boat and davit prior to returning to operation. Test to be to the satisfaction of a US coast Guard Marine Inspector or ABS Surveyor if a USCG Marine Inspector is unavailable.
Condition: Unknown
Due 1 August 2001
Resolved 7 August 2001
Fire Fighting
Issued 20 January 2001
Resolved
Conduct annual servicing of the fixed fire extinguishing system for the engine room. Test all alarms in the presence of a Coast Guard Marine Inspector.
Condition: Unknown
Due 20 January 2001
Resolved 20 January 2001
Navigation
Issued 20 January 2001
Resolved
Install a light and provide a current deviation table for the magnetic compass.
Condition: Unknown
Due 20 January 2001
Resolved 20 January 2001
Lifesaving
Issued 20 January 2001
Resolved
Provide on board vessel a Coast Guard approved Rescue Boat as required by 46 CFR 108.560.
Condition: Unknown
Due 20 January 2001
Resolved 20 January 2001
Electrical
Issued 20 January 2001
Resolved
Repair and proved the proper operation of the Starboard Generator Reverse Power Relay.
Condition: Unknown
Due 20 January 2001
Resolved 20 January 2001
Engineering
Issued 23 January 1999
Resolved
Make repairs to Oily Water Seperator. Upon effecting repairs, test system,log repairs as complete, and send a signed copy of the log (Master's signature) to EURMI to clear the requirement.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Accommodation/Occupational Safety
Issued 1 May 1996
Resolved
REPAIR OR REPLACE THE SHIP'S SANITATION PUMP.
Condition: Unknown
Due 5 May 1996
Resolved 14 May 1996
Fire Fighting
Issued 1 May 1996
Resolved
REPLACE THE VESSEL'S TWO RUPTURED FIRE HOSES.
Condition: Unknown
Due 5 May 1996
Resolved 14 May 1996
Navigation
Issued 1 May 1996
Resolved
REPLACE THE DEFECTIVE 2182KHZ EMERGENCY SIGNAL GENERATING DEVICE.
Condition: Unknown
Due 5 May 1996
Resolved 14 May 1996
Electrical
Issued 1 May 1996
Resolved
PROPERLY WIRE THE DC AND AC ENDS OF THE SHIP'S SERVICE DIESEL GENERATOR STARTING BATTERY CHARGER.
Condition: Unknown
Due 5 May 1996
Resolved 14 May 1996
Deck/Cargo
Issued 1 May 1996
Resolved
REPLACE IN KIND THE TOWING WINCH STARTING AIR RECEIVER. CLEARED 14MAY96.
Condition: Unknown
Due 5 May 1996
Resolved 14 May 1996
Lifesaving
Issued 1 May 1996
Resolved
PROVIDE 2 CG-INSPECTED INFLATABLE LIFERAFTS WITH HYDROSTATIC RELEASES. A COMBINED CAPACITY OF 17 PERSONS MUST BE PROVIDED.
Condition: Unknown
Due 5 July 1996
Resolved 14 May 1996
Lifesaving
Issued 16 March 1992
Resolved
INSTALL MISSING SIGHT GLASS GUARDS IN ENGINEROOM AND MACHINERY SPACES. A SIGNED WRITTEN REPORT FROM [name withheld] TO [name withheld] OF GUARDS TO ALL SIGHT GLASSES WILL SATISFY THIS REQUIREMENT.
Condition: Unknown
Due 16 March 1992
Resolved 16 March 1992
Fire Fighting
Issued 16 March 1992
Resolved
UPON ARRIVAL TO NEXT U.S. PORT HAVE HAND HELD PORTABLE FIRE EXTINGUISHERS SERVICED/HYDROSTATICALLY TESTED AT A U.S. DOT SERVICING FACILITY. PROVIDE A COPY OF SERVICING REPORT TO [name withheld].
Condition: Unknown
Due 16 March 1992
Resolved 16 March 1992
Construction/Loadline
Issued 20 September 1991
Resolved
SUBMIT COPY TO [name withheld], OF ABS REPORT OF REPAIRS MADE TO STBD. SIDE IN WAY OF NUMBER 10 WING FUEL TANK, APPROXIMATELY FROM FRAME 35-40.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Documentation
Issued 10 March 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 March 1990
Resolved 10 March 1990
Navigation
Issued 10 March 1990
Resolved
REPAIR PORT RADAR.
Condition: Unknown
Due 10 March 1990
Resolved 10 March 1990
Engineering
Issued 10 March 1990
Resolved
INSTALL RACOR FUEL FILTER DRIP/FLAME SHIELDS ON PORT & STBD GENERATOR.
Condition: Unknown
Due 10 March 1990
Resolved 10 March 1990
Lifesaving
Issued 11 February 1989
Resolved
PROVIDE TWO ADDITIONAL LIFEJACKETS (CG-APPROVED) WITH LIGHTS, TAPE AND WHISTLES. UNTIL THEY ARE PROVIDED, THE VESSEL MAY CARRY NO MORE THAN 15 TOTAL PEOPLE.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Engineering
Issued 11 February 1989
Resolved
AFTER OVERHAUL OF MAIN ENGINES, PROVIDE A WRITTEN/TELEX REPORT OF THE COMPLETION OF TESTING OF SAFETY DEVICES.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Electrical
Issued 11 February 1989
Resolved
AFTER OVERHAUL OF DIESEL GENERATORS, PROVIDE A WRITTEN/TELEX REPORT OF TESTING OF SAFETY DEVICES.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Construction/Loadline
Issued 17 February 1988
Resolved
FREE UP AND PROVE PROPER OPERATION OF REACHROD IN FOREPEAK TANK.
Condition: Unknown
Due 17 February 1988
Resolved 17 February 1988
Navigation
Issued 17 February 1988
Resolved
REPAIR RUDDER ANGLE INDICATOR AT STEERING STATION IN ENGINE ROOM.
Condition: Unknown
Due 17 February 1988
Resolved 17 February 1988
Engineering
Issued 17 February 1988
Resolved
REPAIR LATCHES FOR MAIN ENGINE DECK COVERS.
Condition: Unknown
Due 17 February 1988
Resolved 17 February 1988
Lifesaving
Issued 17 February 1988
Resolved
HYDROSTATICALLY TEST ALL THREE (3) EMERGENCY BREATHING APPARATUS AIR BOTTLES.
Condition: Unknown
Due 17 February 1988
Resolved 17 February 1988
Lifesaving
Issued 29 April 1987
Resolved
PROVIDE TWO COAST GUARD APPROVED AND SERVICED LIFERAFTS. IF THE USCG APPROVED AND SERVICED LIFERAFTS ARE NOT ABOARD THE VESSEL BY 29MAY87, THE MASTER SHALL NOT OPERATE THE VESSEL UNTIL THE RAFTS ARE INSTALLED ON THE VESSEL.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Electrical
Issued 29 April 1987
Resolved
PROVE PROPER OPERATION OF HIGH WATER TEMPERATURE ALARM ON #1 SHIP'S SERVICEGENERATOR.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Navigation
Issued 29 April 1987
Resolved
REPAIR RUDDER ANGLE INDICATORS AT BRIDGE AFT STEERING STATION AND EMERGENCYSTEERING STATION IN ENGINEROOM.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Engineering
Issued 29 April 1987
Resolved
REPAIR OVERSPEED ON PORT MAIN DIESEL ENGINE.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987
Resolved
CONDUCT MAN OVERBOARD DRILL AND LAUNCH THE RESUCE BOAT.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Engineering
Issued 29 April 1987
Resolved
PROVE PROPER OPERATION OF THE REACH ROD FOR THE BILGE SUCTION LINE VALVE IN THE FORWARD PEAK TANK.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987
Resolved
PROVIDE 12 USCG APPROVED DISTRESS SIGNALS.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Fire Fighting
Issued 29 April 1987
Resolved
RECHARGE FOUR 100 POUND CO2 BOTTLES AND INSTALL IN FIXED FIRE FIGHTING SYSTEM ABOARD THE VESSEL (OR REMOVE SYSTEM FROM VESSEL).
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987
Resolved
PROVIDE LIGHT FOR RING BUOY.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Unknown
Issued 7 February 1986
Resolved
REMOVE LIQUID MUD FROM STERN WRAPPER TANKS.
Condition: Unknown
Due 7 February 1986
Resolved 7 February 1986
Unknown
Issued 7 February 1986
Resolved
MAKE STERN WRAPPER TANKS READY FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 7 February 1986
Resolved 7 February 1986
Engineering
Issued 7 March 1985
Resolved
INSTALL PROPER RELIEF VALVES ON THE AIR SYSTEM SUITABLE FOR 200 MAWP TANK AND COMPRESSOR.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Deck/Cargo
Issued 7 March 1985
Resolved
MAKE THE PORT ANCHOR WINCH OPERABLE.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Engineering
Issued 7 March 1985
Resolved
MAKE THE OILY WATER SEPARATOR OPERABLE AND TEST THE OPERATION IN THE PRESENCE OF A U. S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Engineering
Issued 7 March 1985
Resolved
MAKE OPERABLE THE AUDIBLE ALARM ON THE MAIN ENGINE CONTROL PANEL.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Lifesaving
Issued 7 March 1985
Resolved
INSTALL A GENERAL ALARM BELL IN THE VICINITY OF THE BOW THRUSTER COMPARTMENT.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985