VENGEANCE

VENGEANCE is a 1984 commercial fishing vessel. The Coast Guard has recorded 16 inspections since 2016, most recently in August 2023, along with 14 deficiencies.

Records from 2016 to 2023. Most recent: inspection, 6 August 2023.

Built
1984
Last inspected
6 August 2023
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDG3371
230073
Flag
UNITED STATES
Maury page id
psix-230073

Inspections, by type

…with no type recorded3
Years with a record 8 calendar years (2016–2023)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 15.0 ft × 9.0 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG & S BOATS INC · DESTIN, FL, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 19 December 2025 · expires 31 December 2026
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 16

6 August 2023 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7764654
26 April 2023 Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 7685421
20 October 2022 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7580819
22 June 2022 Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7484938
3 December 2021 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7361826
2 August 2021 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7276700
22 June 2021 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7233661
3 August 2020 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7024000
29 April 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6948010
3 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6826549
21 May 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6705254
22 May 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6416767
29 March 2018 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6376517
11 April 2017 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6117650
3 May 2016 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5867866
24 March 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5837528

Deficiency record · 14

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 June 2022 Resolved
Inspect hull in accordance 46 CFR 176.802. Hull has numerous blistering/delaminations above waterline. To be addressed within one year.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2023
Resolved 9 May 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 October 2019 Resolved
Escape hatches are required to be labeled on both sides EMERGENCY EXIT-KEEP CLEAR. Vsl missing labeling on outside. 46 CFR 185.30-15.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: Crew marked the outside of the emergency exit as required.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 October 2019 Resolved
Waterlight for lifefloat should be attached to lifefloat with 3/8" 18ft line wrapped around teh body of lifefloat. Currently line for waterlight is attached to lifefloat grab lines. 46 CFR 180.175 (f)(4)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: Crew properly attached the waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2019 Resolved
Waterlight for ring buoy must be attached around body of ring buoy with 3ft of line with corrosion resistant clip. Current clip does not open/close easily. 46 CFR 180.70(d)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: New clip was installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 October 2019 Resolved
Emergency fuel shut off shall be marked in letters 1" high indicating purpose and direction of operation. 46 CFR 180.30-20
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: Crew marked emergency fuel shut offs.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 October 2019 Resolved
Vsl required to have emergency radio instructions at radio installation. Vessel had none. 46 CFR 184.506
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: Rep printed out instructions and posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 October 2019 Resolved
Stowage of life jackets should annotate number stored. Current numbers are incorrect. 46 CFR 185.604(f)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: Stowage was properly marked as required.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 October 2019 Resolved
Provisions shall be made to prevent admission of air into space protected. ER is protected with fireboy system. The ventilation to ER does not close properly. 46 CFR 181.20-35
Action required: 60 - Rectify deficiencies prior to movement
Due 4 October 2019
Resolved 4 October 2019
Resolution: Crew replaced vents and they worked properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 October 2019 Resolved
Flexible hose installed for fuel supply lines shall be complete with factory assembled end fittings. If under 30 inches may meet USCG Type A1 SAE 1527. If over 30 inches must meet SAE J 1942 and SAE J1475. Lines on generator fuel supply and return are backing off at fittings. 46 CFR 182.720
Action required: 60 - Rectify deficiencies prior to movement
Due 4 October 2019
Resolved 4 October 2019
Resolution: Crew replaced lines with CG approved lines.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 April 2017 Resolved
Provide alcohol test equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 11 April 2017
Resolution: bought new equipment
Lifesaving › Lifefloat › Retroreflective Material
Issued 11 April 2017 Resolved
Replace the reflective tape on the life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 11 April 2017
Lifesaving › Lifefloat › Serviceable
Issued 11 April 2017 Resolved
Life float has multiple small cracks, repair with the manufactors kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 11 April 2017
Resolution: repaired
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 May 2016 Resolved
Provide FCC Safety Radio Telephony certificate for vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 3 May 2016
Resolution: Was found in the office files same day.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 3 May 2016 Resolved
Rewire and test SSB radio
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 3 May 2016
Resolution: Rewired and tested...