Records from 2016 to 2023. Most recent: inspection, 6 August 2023.
Documentation record
Registered dimensions (L × B × D)48.0 ft × 15.0 ft × 9.0 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG & S BOATS INC · DESTIN, FL, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 19 December 2025 · expires 31 December 2026
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
6 August 2023
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7764654
26 April 2023
Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 7685421
20 October 2022
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7580819
22 June 2022
Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7484938
3 December 2021
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7361826
2 August 2021
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7276700
22 June 2021
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7233661
3 August 2020
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7024000
29 April 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6948010
3 October 2019
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6826549
21 May 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6705254
22 May 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6416767
29 March 2018
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6376517
11 April 2017
COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6117650
3 May 2016
Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5867866
24 March 2016
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5837528
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 June 2022
Resolved
Inspect hull in accordance 46 CFR 176.802. Hull has numerous blistering/delaminations above waterline. To be addressed within one year.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2023
Resolved 9 May 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 October 2019
Resolved
Escape hatches are required to be labeled on both sides EMERGENCY EXIT-KEEP CLEAR. Vsl missing labeling on outside.
46 CFR 185.30-15.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: Crew marked the outside of the emergency exit as required.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 October 2019
Resolved
Waterlight for lifefloat should be attached to lifefloat with 3/8" 18ft line wrapped around teh body of lifefloat. Currently line for waterlight is attached to lifefloat grab lines.
46 CFR 180.175 (f)(4)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: Crew properly attached the waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2019
Resolved
Waterlight for ring buoy must be attached around body of ring buoy with 3ft of line with corrosion resistant clip. Current clip does not open/close easily.
46 CFR 180.70(d)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: New clip was installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 October 2019
Resolved
Emergency fuel shut off shall be marked in letters 1" high indicating purpose and direction of operation.
46 CFR 180.30-20
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: Crew marked emergency fuel shut offs.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 October 2019
Resolved
Vsl required to have emergency radio instructions at radio installation. Vessel had none.
46 CFR 184.506
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: Rep printed out instructions and posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 October 2019
Resolved
Stowage of life jackets should annotate number stored. Current numbers are incorrect.
46 CFR 185.604(f)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 4 October 2019
Resolution: Stowage was properly marked as required.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 October 2019
Resolved
Provisions shall be made to prevent admission of air into space protected. ER is protected with fireboy system. The ventilation to ER does not close properly.
46 CFR 181.20-35
Action required: 60 - Rectify deficiencies prior to movement
Due 4 October 2019
Resolved 4 October 2019
Resolution: Crew replaced vents and they worked properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 October 2019
Resolved
Flexible hose installed for fuel supply lines shall be complete with factory assembled end fittings. If under 30 inches may meet USCG Type A1 SAE 1527. If over 30 inches must meet SAE J 1942 and SAE J1475. Lines on generator fuel supply and return are backing off at fittings.
46 CFR 182.720
Action required: 60 - Rectify deficiencies prior to movement
Due 4 October 2019
Resolved 4 October 2019
Resolution: Crew replaced lines with CG approved lines.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 April 2017
Resolved
Provide alcohol test equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 11 April 2017
Resolution: bought new equipment
Lifesaving › Lifefloat › Retroreflective Material
Issued 11 April 2017
Resolved
Replace the reflective tape on the life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 11 April 2017
Lifesaving › Lifefloat › Serviceable
Issued 11 April 2017
Resolved
Life float has multiple small cracks, repair with the manufactors kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 11 April 2017
Resolution: repaired
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 May 2016
Resolved
Provide FCC Safety Radio Telephony certificate for vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 3 May 2016
Resolution: Was found in the office files same day.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 3 May 2016
Resolved
Rewire and test SSB radio
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 3 May 2016
Resolution: Rewired and tested...