MAURY USCG vessel records Sign in
← All vessels

BW HERMES

BW HERMES is a 1982 tank ship. The Coast Guard has recorded 56 inspections since 1985, most recently in May 2012, along with 14 deficiencies and 5 operational controls.

Records from 1985 to 2012. Most recent: inspection, 25 May 2012.

Built
1982
Last inspected
25 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8131104 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
230227
Flag
LUXEMBOURG
—
Maury page id
psix-230227

Inspections, by type

…with no type recorded36
Years with a record 19 calendar years (1985–2012)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6804 - Convention (Subpart B), Net Ton
36060 - Displacement, Ton
26970 - Dead Weight, Ton
18152 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LINDA L Tank Barge · MISLE 43402 · 10 May 1995 · activity 60175

Inspection history · 56

25 May 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4321513
14 May 2012 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4310977
12 December 2011 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4206475
11 March 2009 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3431401
21 November 2008 Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3367005
6 October 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3074188
5 September 2007 COC-GAS Renew · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3049473
5 July 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2702537
5 July 2006 Type not recorded
No type recorded · USCG Heartland District (dpb) · USCG Heartland District (CGD-H) · Activity 2708598
6 February 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2580854
3 February 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2579131
5 January 2006 Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 2561823
3 January 2006 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2559967
30 October 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2525773
26 October 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2522957
18 July 2005 ISPS II Exam · COC-GAS Renew
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2434524
17 July 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2429320
17 July 2005 Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 2430619
24 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2264488
24 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2307315
22 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2264304
21 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2263408
7 September 2004 ISPS II Exam · MARPOL Annex V Examination · COC-TVE Annual · STCW 95 Exam · MARPOL Annex I Examination · ILO-147 Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2189299
15 April 2003 Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1773656
15 February 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 400525
10 January 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 399384
10 January 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1098288
13 September 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 382629
25 May 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 703091
10 May 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 60175
2 March 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 375819
28 February 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 375827
9 February 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 16959
18 October 1994 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1176570
16 September 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1178843
11 April 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 365836
9 February 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 439538
3 October 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 537821
2 May 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 357848
21 April 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1133742
20 April 1993 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1387321
16 October 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 540749
14 October 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 353706
14 October 1992 Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 953231
30 July 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1251233
13 April 1991 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1241835
8 February 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 535277
8 February 1989 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1349632
21 March 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 524983
23 July 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 310302
23 July 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1000115
23 January 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 455581
22 October 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 463031
9 July 1985 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 476920
9 July 1985 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 978203
21 April 1985 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 982921

Deficiency record · 14

Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 September 2007 Resolved
The Ship has several fire doors within the stairway that was refitted with a self closing mechanism. The modifications left open holes within the fire doors and the self closing mechanism has not been adjusted as to allow the door to fully close. The Master/Owner/Operator shall ensure that the fire doors meet the minimum fire integrity that was originally designed for the ship.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 September 2007
Resolution: Fire doors integrity and self closing mechanism were corrected.
Construction/Loadline › Markings › Load Line Mark
Issued 5 September 2007 Resolved
The ship did not have load line markings to that of the valid Int'l Load Line Certificate. The ship shall verify the correct load line and ensure that the load line displayed is the issued load line by the ship's classification society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 September 2007
Resolution: Loadline marks corrected and resembles the ship''s valid ILLC.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 7 September 2004 Resolved
Instructions for fixed dry-chemical (CO2 activated) fire stations at port & stbd manifolds are either missing or do not show proper instructions. re-new instructions prior to 07Oct04.
Condition: Unknown
Due 7 October 2004
Resolved 18 July 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 7 September 2004 Resolved
Transfer & Vapor hoses have not been hydrostatically tested within the past 12 months. (46CFR153) Hydrostatically test cargo hoses prior to next use in cargo operations.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 7 September 2004 Resolved
The No. 1 Stbd liquid line quick closing valve does not operate properly. (IMO Gas Carrier Code Chap. V.5.3.) Have Class Society provide a report attesting to proper operation prior to use.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2005
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 7 September 2004 Resolved
Ventilation for Emergency Generator Room does not have any closure devices. (Solas II-1, Reg-43) Provide closures by 07Oct04.
Condition: Improper/Lack of Maintenance
Due 7 October 2004
Resolved 18 July 2005
Fire Fighting › Means of Escape › Blocked
Issued 7 September 2004 Resolved
Steering gear Room emergency escape hatch dogs are inoperable. (Solas II-2, Reg. 45) Master to provide notice of repair prior to departure from Tampa.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2004
Resolution: Received written report from vessel Master that repairs have been made to escape trunk hatch on poop deck.
Pollution Prevention/Response › Prevention Equipment
Issued 15 April 2003 Resolved
Discharge piping leading to overboard valve from OWS burst. Repair or replace to the satisfaction of class prior to departure. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Due 15 April 2003
Resolved 2 May 2003
Resolution: Pipe was renewed and surveyed for class by chief engineer [name withheld]
Deck/Cargo
Issued 10 January 1997 Resolved
REPAIR AND PROVE OPERATION OF THE INERT GAS SYSTEM PRIOR TO THE NEXT U.S. VOYAGE.
Condition: Unknown
Due 15 January 1997
Resolved 18 February 1997
Deck/Cargo
Issued 10 January 1997 Resolved
PROVIDE A SATISFACTORY TEST AND PROVE OPERATION OF THE DECK CARGO TANK HIGHPRESSURE ALARM PRIOR TO THE NEXT U.S. VOYAGE.
Condition: Unknown
Due 15 January 1997
Resolved 18 February 1997
Deck/Cargo
Issued 16 September 1994 Resolved
MAKE REPAIRS & DEMON. PROPER OPER. OF FOLLOWING ALARMS TO SAT. OF FLAG STATE; 1) OILY WATER SEP., 2)CARGO HIGH LEVEL & OVERFILL, 3)HIGH & LOW PRES., 4)TEMP. FOR CARGO, 5)ALL INERT GAS ALARMS, 6)LIQ. LEVEL 7) PRESS/VAC. HIGH/LOW PRESS. SENSOR PROVIDE SAT. REPORT TO LOCAL U.S.C.G.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Documentation
Issued 16 September 1994 Resolved
PROVIDE ON BOARD CURRENT REGULATIONS, 46 CFR 35 & 46 CFR 150, 153, & 154, PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Deck/Cargo
Issued 20 April 1993 Resolved
PORTABLE CARGO HOSES MUST BE MARKED W/MAWP AND TYPE OF CARGO FOR WHICH THEYARE USED.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Deck/Cargo
Issued 20 April 1993 Resolved
PROVE PROPER OPERATION OF INERT GAS SYSTEM PRIOR TO NEXT LOADING OF CARGO THAT REQUIRES INERTING. MUST BE WITNESSED BY U.S.C.G. INSPECTOR
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.