APL CORAL

APL CORAL is a 1997 freight ship. The Coast Guard has recorded 30 inspections since 2006, most recently in May 2017, along with 20 deficiencies — 4 with no resolution recorded —, 1 operational control and 3 casualty investigations between 2012 and 2015.

Records from 2006 to 2017. Most recent: inspection, 22 May 2017.

Built
1997
Last inspected
22 May 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9139749 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF6832
Flag
MALTA
367478280 (licence lapsed)
Maury page id
psix-23024

Inspections, by type

…with no type recorded8
…past their stated due date4
Years with a record 9 calendar years (2006–2017)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it65475 - Convention (Subpart B), Gross Ton
28825 - Convention (Subpart B), Net Ton
871216 - Displacement, Ton
641566 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDF6832MMSI 367478280 · cancelled · compulsorily equipped · granted 5 February 2011, cancelled 7 December 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 30

22 May 2017 Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6152001
14 July 2016 Deficiency Check · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5940122
2 June 2016 Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 5894732
12 April 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5852282
3 March 2016 Internal Structural Exam · Hull Examination · Underwater Inspection in lieu of Drydock
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5825992
28 August 2015 Type not recorded
No type recorded · Activities Europe · Activity 5230910
28 August 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5231986
2 August 2015 MTSA/ISPS Verification · Annual Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5201006
8 October 2014 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5001144
19 August 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4959937
15 August 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4955405
1 August 2014 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4945944
21 March 2014 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4820144
15 March 2014 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4816756
3 July 2012 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4366394
27 June 2012 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4358046
15 December 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4209115
22 August 2011 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4123573
21 August 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4232628
21 August 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4232657
15 August 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4118286
12 July 2011 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4078990
9 March 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3161054
1 February 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3140294
8 June 2007 ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2955311
26 April 2007 PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2916433
24 May 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2658070
22 April 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2629215
20 April 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2629273
16 April 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2625852

Deficiency record · 20

Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 29 July 2016 No resolution recorded
Measures shall be taken to the satisfaction of the Administration to ensure that equipment is functioning in a reliable manner & that satisfactory arrangements are made for regular inspections & routing tests to ensure continuous reliable operation. There is no record of OCMI and/or ABS witnessing PSTP’s for Revision 6.
Action required: 705 - Other - as specified
Due 29 September 2016 — due date passed with no resolution recorded
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 29 July 2016 No resolution recorded
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routing tests to ensure continuous reliable operation. Several PSTP step-by-step descriptions are generic, with several steps associated with specific machinery missing or vague.
Action required: 705 - Other - as specified
Due 29 September 2016 — due date passed with no resolution recorded
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 29 July 2016 No resolution recorded
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routing tests to ensure continuous reliable operation. Standard Procedure PRS-2 of the vessel’s PSTP’s does not fully describe the means of identifying the local parameters to be tested.
Action required: 705 - Other - as specified
Due 29 September 2016 — due date passed with no resolution recorded
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 29 July 2016 No resolution recorded
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routing tests to ensure continuous reliable operation. PSTP’s do not indicate at what intervals the required tests are to be conducted.
Action required: 705 - Other - as specified
Due 29 September 2016 — due date passed with no resolution recorded
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 29 July 2016 Resolved
Measures shall be taken to the satisfaction of the Administration to ensure the equipment is functioning in a reliable manner & that satisfactory arrangements are made for regular inspections and routing tests to ensure continuous reliable operation. Crewmembers were unable to complete required Standard Procedures PRS-3, PRS-4, & TMP-2 because the required testing equipment was not onboard.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 29 July 2016
Resolution: Test equipment purchased locally.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 29 July 2016 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Wilden pump installed on the Gray Water piping before the educator. Restore as original or submit proposal to ABS to modify pumping & piping arrangements.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 29 July 2016
Resolution: Piping re-installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 July 2016 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Found a dead-end electrical wire located in the overhead below the purifier room.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 12 August 2016
Resolution: Junction box installed.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 29 July 2016 Resolved
Any main and auxiliary steering gear control system operable from the bridge shall, in the event of failure of electrical power supply to the control system, an audible and visual alarm shall be given on the bridge. When testing the loss of power function, the audible alarm was not functioning.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 29 July 2016
Resolution: Corrected.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 1 August 2014 Resolved
Emergency fire pump discharge side check valve did not work resulting in blown gasket in strainer on suction side. Replace/ repair check valve and gasket to satisfaction of marine inspector.
Due 15 September 2014
Resolved 1 August 2014
Resolution: Cleared during inspection
Engineering › Freshwater Generation System › Piping
Issued 1 August 2014 Resolved
Wastage and leaking pipe found on drain line on stbd side of engine room on the lower level. Repair/replace to the satisfaction of a CG Marine Inspector.
Due 15 September 2014
Resolved 15 August 2014
Resolution: Vessel provided evidence of replacing the wasted drainage pipe. Vessel cropped and renewed the wasted section of pipe and renewed with a new piece and welded it in place.
Engineering › Freshwater Generation System › Piping
Issued 1 August 2014 Resolved
Provide repair proposal at leaking / wasted drain pipe found in the paint locker to the satisfaction of CG Marine Inspector.
Due 15 September 2014
Resolved 20 August 2014
Resolution: Vessel provided evidence of repairing the leaking drain line. Vessel removed the pipe coupling, renewed it and reinstalled it.
Electrical › Electric Supply System (service) › Cable
Issued 1 August 2014 Resolved
Electrical wires bound with plastic zip ties in BOS'N stores locker on main deck amidships. Secure properly to satisfaction of CG Marine Inspector.
Due 15 September 2014
Resolved 15 August 2014
Resolution: Vessel provided evidence of removing the wire plastic zip ties in the BOS''N stores. Vessel installed new wire runs and secured wires with metal cable ties.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 August 2014 Resolved
Junction box in BOS'N store locker not supported properly. Secure J Box properly to satisfaction of CG Marine Inspector.
Due 15 September 2014
Resolved 15 August 2014
Resolution: Vessel provided evidence of properly securing the Junction boxes located in the BOS''N Stores. Plastic zip ties were removed and the J box was properly mounted using welded studs and nuts.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 August 2014 Resolved
Exhaust ventilation insulation missing on ventilation in paint locker stores. Replace to satisfaction of CG Marine Inspector.
Due 15 September 2014
Resolved 20 August 2014
Resolution: Vessel provided evidence that the insulation was replaced in the paint locker around exhaust ventilation.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 August 2014 Resolved
Deck light on main deck on stern found damaged. Repair or replace to satisfaction of CG Marine Inspector.
Due 15 September 2014
Resolved 15 August 2014
Resolution: Vessel provided evidence of renewing the deck light on the main deck on the fantail on the stern.
Engineering › Bilge Water Management System › Valve
Issued 1 August 2014 Resolved
Starboard side ballast overboard valve found leaking in engine room. Repair/replace to satisfaction of CG Marine Inspector.
Due 15 September 2014
Resolved 20 August 2014
Resolution: Vessel provided evidence of the starboard side ballast overboard valve being overhauled. Valve was removed and overhauled to the satisfaction of a marine inspector.
Engineering › Lubricating Oil Service System › Piping
Issued 27 June 2012 Resolved
#1 SSDG has numerous l/o leaks. There is excessive l/o in the containment area. l/o shall be removed properly.
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 3 July 2012
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 27 June 2012 Resolved
Purifier room lagging is saturated with f/o. lagging needs to be replaced in kind.
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 3 July 2012
Engineering › Fuel Oil Service System › Piping
Issued 27 June 2012 Resolved
HFO pump and piping lagging is saturated with f/o. replace in kind.
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 3 July 2012
Lifesaving › Launching Appliances › Davit
Issued 27 June 2012 Resolved
Adjust limit switch on the stbd lifeboat davit and retest during lifeboat retreival.
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 3 July 2012

Casualty record · 3

27 April 2012Routine · role: Transiting Vicinity of Primary Subject · activity 4297237
2 February 2014Routine · role: Involved in a Marine Casualty · activity 4798439
6 April 2015Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 5097201
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.