RIP CURRENT is a 1984 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1984, most recently in July 2026, along with 98 deficiencies, 1 operational control and 1 casualty investigation in 2007.

Records from 1984 to 2026. Most recent: inspection, 29 July 2026.

Built
1984
Last inspected
29 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB9922
230500
Flag
UNITED STATES
368229750
Maury page id
psix-230500

Inspections, by type

…with no type recorded6
Years with a record 29 calendar years (1984–2026)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)37.4 ft × 13.6 ft × 5.8 ft
Registered tonnagegross 20 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMICHAEL FITZ CUSTOM BOATS · NAPLES, FL, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 17 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM6972MMSI 368229750 · active · compulsorily equipped · granted 3 December 2021, expires 3 December 2031
WDB9922MMSI 366985110 · expired · compulsorily equipped · granted 22 October 2004, cancelled 27 December 2014
WCZ8936MMSI not assigned · expired · compulsorily equipped · granted 20 June 2000, cancelled 21 August 2010
WCX8059MMSI not assigned · expired · compulsorily equipped · granted 22 October 1997, cancelled 22 December 2007 · licensed under a name not among this hull’s recorded names (not shown)
WCW9755MMSI not assigned · expired · compulsorily equipped · granted 11 December 1996, cancelled 10 February 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 60

29 July 2026 Type not recorded
No type recorded · USCGC OLIVIA HOOKER (WPC 1161) · USCG Heartland District (CGD-H) · Activity 8455281
6 March 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8321168
20 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8126885
1 April 2025 Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 8109261
3 February 2025 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8074002
24 April 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7900975
23 May 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7712817
31 March 2023 Administrative Inspection · Inclining Experiment
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7660422
2 February 2023 Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631270
3 October 2022 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7571584
25 May 2022 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7459833
31 March 2022 In-Service Inspection · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7422386
24 February 2022 Administrative Inspection · COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7401669
8 September 2021 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7307713
3 February 2021 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7135099
13 June 2007 Type not recorded
No type recorded · Commandant (CG-INV) · Activity 2960249
7 June 2007 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2953143
29 March 2006 Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2611796
20 October 2005 Damage Survey · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2493086
11 May 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2355197
16 February 2005 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2294060
15 February 2005 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2292746
25 October 2004 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2227708
29 June 2004 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2114697
12 August 2003 Annual Inspection · Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1873921
19 April 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465635
6 July 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1052204
23 May 2000 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1437727
21 October 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1126527
17 September 1999 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 784899
23 April 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410076
21 May 1998 Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1418529
29 September 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1390630
23 July 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1390596
5 December 1996 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1392605
23 July 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1392604
12 September 1995 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1181503
25 May 1995 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1190222
1 June 1994 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1171905
8 June 1993 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 960709
17 July 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1257981
1 June 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 949392
28 May 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 949550
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1309701
14 August 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 942269
9 July 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 940945
12 July 1990 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214234
7 June 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1232681
18 April 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 906650
24 January 1990 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1238587
17 January 1990 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 918035
26 July 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1198572
7 June 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1343135
14 September 1988 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1351917
12 August 1987 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1337231
25 February 1987 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1311570
7 August 1986 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 999987
18 October 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 994509
26 September 1985 Credit Drydock · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1298819
22 August 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1282747

Deficiency record · 98

05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 20 May 2025 Resolved
A durable placard must be posted next to all radiotelephone installations with emergency broadcast instructions and information, specific to the individual vessel. Top of vessel's placard was worn off and missing first step of instructions. Replace placard. 46 CFR 184.506
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 5 June 2025
Resolution: New sticker installed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 23 May 2023 Resolved
Crew members were not listed as being part of the random drug testing through vessel's drug consortium.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2023
Resolved 26 June 2023
Resolution: Received satisfactory documentary evidence; vessel cleared
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 31 March 2022 Resolved
Vessel prohibited from adding any type of canopy or covering to top deck pilothouse IAW COI and Stability letter. Vessel found with canopy in place. Remove covering and complete satisfactory in-service inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2022
Resolved 1 April 2022
Resolution: In-service complete. Cover had been removed.
Documentation › Certificates/Documents › FCC SSL
Issued 7 June 2007 Resolved
Provide a FCC Marine Radio Operator Permit as required by 47CFR
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: FCC operators permit was valid.
Operations/Management › Passenger Operations › Safety Orientation
Issued 7 June 2007 Resolved
Provide means to keep a correct written count of all passengers ashore as required by 46 CFR 185.504
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: Passenger count is kept at the office.
Lifesaving › Hand Flares › Quantity
Issued 7 June 2007 Resolved
Provide one daytime distress signal as required by 46 CFR 180.68
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: Required distress signals are onboard.
Construction/Loadline › Structures › Superstructure
Issued 7 June 2007 Resolved
Replace missing glass in accommodation space as required by 46 CFR 176.800
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: All glass was installed in accommodation spaces.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 June 2007 Resolved
Make aft rail meet courses of the rest of the vessel as required by 46 CFR 177.900
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: Adequate rail height throughout the vessel.
Lifesaving › Lifefloat › Quantity
Issued 7 June 2007 Resolved
Provide an approved lifefloat as required by 46 CFR 1800.200 Until this item is cleared by an attending Coast Guard Marine Inspector to vessel is restricted to a Lakes, Bays, and Sounds Route.
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: Lifefloats were installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 June 2007 Resolved
Provide an approved battery for the waterlight on the lifefloat and ring life buoy as required by 46 CFR 180.70 and 180.175
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: Approved battery was installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 June 2007 Resolved
Properly splice the lifeline to the ring life buoy and properly splice the lanyard for the waterlight to the non-corrosive clip as required by 46 CFR 180.70
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: Proper lifeline was installed on the ring life buoy.
Engineering › Fuel Oil Service System › Filter
Issued 7 June 2007 Resolved
Provide a metal plug for both fuel strainers and a strainer bowl for the port fuel strainer as required by 46 CFR 182.455
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: Filters with approved plugs were installed.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 7 June 2007 Resolved
Tighten or repack the starboard shaft log to reduce the excessive leak as required by 46 CFR 176.800
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: There was no noted excessive leakage in the location noted.
Engineering › Bilge Water Management System › Not Installed
Issued 7 June 2007 Resolved
Properly mount the float switch for the bilge pump in the forward compartment as required by 46 CFR 182.520
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: Float switch was installed.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 7 June 2007 Resolved
Prove operation of generator as required by 46 CFR 176.500
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: Generator was working during exam.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 June 2007 Resolved
Remove dead-end wires in aft part of engine room and under console in pilot house as required by 46 CFR 183.340
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: Wires were removed.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 June 2007 Resolved
Properly mount the loose circuit breaker in tool room as required by 46 CFR 183.330
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 25 February 2022
Resolution: Circuit breaker was mounted.
Documentation › Certificates/Documents › FCC SSL
Issued 29 March 2006 Resolved
Provide a FCC safety certificate.
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Provided a FCC safety certificate.
Documentation › Logs/Records › Logbook (official)
Issued 29 March 2006 Resolved
Provide a current training logbook IAW 46 CFR 185.420
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Provided a current training logbook
Documentation › Logs/Records › Logbook (official)
Issued 29 March 2006 Resolved
Provide a life saving equipment maintenance manual IAW 46 CFR 185.702
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Provided a life saving equipment maintenance manual.
Documentation › Logs/Records › Logbook (official)
Issued 29 March 2006 Resolved
Provide a ships bridge logbook with all required entries IAW 46CFR 185.702
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Provided a ships bridge logbook.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 29 March 2006 Resolved
Provide and install retro reflective tape on the life jackets as needed IAW 46 CFR 185.604
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Installed retro tape on life jackets.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 29 March 2006 Resolved
Properly label the life jacket stowage area IAW 46 CFR 180.78
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Labeled life jacket stowage locker.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 March 2006 Resolved
Provide and install machinery guards over rotating machinery in the engine room as required by 46 CFR 177.960 to the satisfaction of the attending marine inspector.
Action required: 10 - Deficiency Rectified
Due 29 April 2006
Resolved 25 February 2022
Resolution: Machinery guards were installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2006 Resolved
Properly install the electrical wiring connection for the anchor windless in a watertight box. 46CFR 183.210
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Installed electrical wiring in a watertight box for anchor windless.
Stability › Watertight Integrity › General
Issued 29 March 2006 Resolved
Provide and install a new dog for the port light in the accommodation space. 46 CFR 179.350
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Installed a new dog for the port light.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 March 2006 Resolved
Replace cracked lens on both port and starboard running lights. IAW 46 CFR 176.800
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Replaced both port and starboard running lights.
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 March 2006 Resolved
Properly secure and provide illumination for the magnetic compass IAW 46 CFR 184.402
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Secured compass and provided compass illumination.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 29 March 2006 Resolved
Properly secure the water light to the lifefloat IAW 46 CFR 180.175
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Secured water light to lifefloat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2006 Resolved
Remove dead ended electrical wiring in the engine room IAW 46 CFR 183.340
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Removed dead ended cable from engine room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2006 Resolved
Secure all electrical wiring in the engine room IAW 183.340
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Secured all electrical wiring in the engine room.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 March 2006 Resolved
Prove the rails on the aft deck to meet the height requirement in 46 CFR 177.35-1
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Provided proof of hand rail height.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 29 March 2006 Resolved
Provided and install a volt and frequency meter at the control panel for the ship service generator IAW 46 CFR 183.10-5
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 2 May 2006
Resolution: Installed a volt and frequency meter.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 16 February 2006 Resolved
Provide proper anchor 46CFR184.300
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 7 March 2006
Resolution: New anchor onboard.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 16 February 2006 Resolved
Properly secure starboard propeller to shaft (Key) 46 CFR 176.630
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 7 March 2006
Resolution: Prop properly attached.
Construction/Loadline › Structures › Superstructure
Issued 16 February 2006 Resolved
Make proper repairs to cracking of bulwarks on stbd side. 46CFR176.800
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 7 March 2006
Resolution: Cracking re-fiberglassed.
Construction/Loadline › Hull › Hull Plating
Issued 16 February 2006 Resolved
Make repairs to blister on hull, inboard of port fwd strut. 46CFR176.800
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 7 March 2006
Resolution: Blister ground out and faired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 February 2006 Resolved
Make proper repairs to loose rails.46CFR177.900
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 7 March 2006
Resolution: Rails are now sturdy
Construction/Loadline › Structures › Door
Issued 16 February 2006 Resolved
Repair 2 cracked windows on main cabin, one on port side, one on starboard. 46CFR176.800
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 7 March 2006
Resolution: Windows replaced.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 16 February 2006 Resolved
Make proper repairs to anchor guide system, replace guide bolt.46CFR184.300
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 7 March 2006
Resolution: Anchor guide system propelry repaired.
Lifesaving › Lifejacket/PFD (Type II) › Marking
Issued 15 April 2005 Resolved
Mark lifejackets with vessel's name in accordance with 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 15 May 2005
Resolved 10 May 2005
Resolution: PFDs were marked w/ the vessel''s name and found satisfactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 April 2005 Resolved
Repair or renew sternlight as per 72 COLREGS to the satisfaction of the attending marine inspector..
Action required: 705 - Other - as specified
Due 15 May 2005
Resolved 10 May 2005
Resolution: Sternlight was renewed and operable.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 15 April 2005 Resolved
Prove proper operation of shutdown of engines, generator, and power ventilation as required by 46 CFR 182.465(h).
Action required: 705 - Other - as specified
Due 15 May 2005
Resolved 10 May 2005
Resolution: Shutdowns were installed and operational.
Construction/Loadline › Hull › Side Shell
Issued 28 February 2005 Resolved
Repair 55 areas of blistering/delamination of bottom and side shell fiberglass reinforced plastic hull noted during hull examination in accordance with NVIC 8-87 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 14 March 2005
Resolved 14 March 2005
Resolution: All repairs were made in accordance with NVIC 8-87 and found satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 28 February 2005 Resolved
Repair 9 holes in hull along the chine in accordance with NVIC 8-87 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 14 March 2005
Resolved 4 March 2005
Resolution: Holes were ground and glassed IAW NVIC 8-87.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 28 February 2005 Resolved
Renew worn cutlass bearings on port/starboard shafts to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 14 March 2005
Resolved 4 March 2005
Resolution: New cutlass bearings were installed and found satisfactory.
Lifesaving › Hand Flares
Issued 26 August 2003 Resolved
Provide six hand held smoke distress signals approved IAW 160.037 as required by 46 CFR 180.68(a)(2). LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 3 September 2003
Lifesaving › Hand Flares
Issued 26 August 2003 Resolved
Provide six red flare distress signals approved IAW 160.021 as per 46 CFR 180.68(a)(1). LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 3 September 2003
Engineering › Fuel Oil Service System
Issued 26 August 2003 Resolved
Remount generator F/O flex hose and provide proper support IAW 46 CFR 182.20-40(b)(2). LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 3 September 2003
Engineering › Sea-water System (primary cooling)
Issued 26 August 2003 Resolved
Replace saltwater flex hose on both main diesel engines going to heat exchanger from raw water pump. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 3 September 2003
Unknown
Issued 23 May 2000 Resolved
PROVIDE SATISFACTORY DOCUMENTATION THAT THE MARINE EMPLOYER HAS AN ESTABLISHED CHEMICAL TESTING PROGRAM AS IDENTIFIED IN 46 CFR PART 16. PROVIDE DOCUMENTATION TO MSO NEW ORLEANS DAPI OFFICER [phone withheld].
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Lifesaving
Issued 23 May 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 June 2000
Resolved 31 May 2000
Construction/Loadline
Issued 23 May 2000 Resolved
PROPERLY REMOVE ALL EXCESS OILY SLOPS FROM BILGE SPACES.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 23 May 2000 Resolved
PROVIDE PROPER AUDIBLE ALARM FOR BILGE HIGH WATER ALARM.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Fire Fighting
Issued 23 May 2000 Resolved
PROVIDE VISUAL AND AUDIBLE DISCHARGE ALARM AT OPERATING STATION FOR FIXED FF SYSTEM IAW 46 CFR 181.420.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Lifesaving
Issued 23 May 2000 Resolved
PROVIDE 03 SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 23 May 2000 Resolved
RENEW DAMAGED BILGE SYSTEM PIPING IN MACHINERY SPACE.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Lifesaving
Issued 23 May 2000 Resolved
PROVIDE PROPER EPIRB HYDROSTATIC RELEASE. VESSEL IS RESTRICTED TO OPERATIONNOT MORE THAN 03 MILES FROM SHORE UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 23 June 2000
Resolved 31 May 2000
Fire Fighting
Issued 23 May 2000 Resolved
PROVIDE CURRENT SERVICING REPORT FOR ALL PORTABLE FIRE EXTINGUISHERS AND FIXED FF SYSTEM.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Engineering
Issued 23 May 2000 Resolved
PROVIDE METAL FIRE BOWL FOR GENERATOR FUEL FILTER.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Documentation
Issued 23 May 2000 Resolved
PROVIDE VALID FCC RADIO STATION LICENSE.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Unknown
Issued 23 April 1999 Resolved
INSTALL FIXED FIRE FIGHTING SYSTEM IN ENG ROOM.
Condition: Unknown
Due 23 April 1999
Resolved 23 April 1999
Lifesaving
Issued 29 September 1997 Resolved
Provide emergency broadcast placard.
Condition: Unknown
Due 14 November 1997
Resolved 14 November 1997
Lifesaving
Issued 29 September 1997 Resolved
Provide drug testing program as required by 46 C.F.R. 16.
Condition: Unknown
Due 14 November 1997
Resolved 14 November 1997
Lifesaving
Issued 29 September 1997 Resolved
Provide emergency drills and log same.
Condition: Unknown
Due 14 November 1997
Resolved 14 November 1997
Fire Fighting
Issued 25 May 1995 Resolved
Service 2 B-II fire extinguishers prior to operating.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Lifesaving
Issued 25 May 1995 Resolved
Label adult and child pfd stowage on main deck.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Engineering
Issued 25 May 1995 Resolved
Install flame shields on 2 racor filters.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Lifesaving
Issued 25 May 1995 Resolved
Repair ringbuoy and lifefloat waterlights.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Lifesaving
Issued 25 May 1995 Resolved
Renew 15 man lifefloat.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Construction/Loadline
Issued 25 May 1995 Resolved
Re-install aft deck hatch.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Lifesaving
Issued 25 May 1995 Resolved
Renew ringbuoy or repair lines, also renew 60' line.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Lifesaving
Issued 25 May 1995 Resolved
Renew flares prior to operation.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Navigation
Issued 25 May 1995 Resolved
Repair mast head light prior to operating.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Electrical
Issued 25 May 1995 Resolved
Permanently mount battery switch.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Navigation
Issued 1 June 1992 Resolved
Repair radar
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Lifesaving
Issued 1 June 1992 Resolved
Repair waterlight for ring buoy. Vessel limited to daylight operation until complete.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Engineering
Issued 1 June 1992 Resolved
REPAIR EMERGENCY FUEL SHUTOFF VALVE CABLES FOR FORWARD TANK.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Electrical
Issued 1 June 1992 Resolved
Clean corrosion from battery terminals.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Documentation
Issued 1 June 1992 Resolved
Provide copy of FCC certificate.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Navigation
Issued 9 July 1991 Resolved
REPAIR STBD SIDELIGHT & STERN LIGHT PRIOR TO CARRYING PASSENGERS AND NO LATER THATN 16JUL91.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Engineering
Issued 9 July 1991 Resolved
RESTENCIL FORWARD FUEL TANK EMERGENCY SHUTOFF PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 16JUL91.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Lifesaving
Issued 9 July 1991 Resolved
REPAIR WATERLIGHT FOR LIFEFLOAT PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 16JUL91.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Engineering
Issued 9 July 1991 Resolved
REPLACE CABLE ON PORT FUEL TANK EMERGENCY SHUTOFF PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 16JUL91.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Construction/Loadline
Issued 7 June 1990 Resolved
GRIND ALL MARKED BLISTERS TO GOOD FIBERGLASS (NO DELAMINATION). 68 BLISTERS
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Construction/Loadline
Issued 7 June 1990 Resolved
REGLASS AS ORGINAL THE BLISTERS IN REQUIREMENT #1.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Engineering
Issued 7 June 1990 Resolved
INSTALL FLAME SCREEN ON PORT AFT FUEL TANK VENT.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Construction/Loadline
Issued 7 June 1990 Resolved
EPOXY OTHER BLISTERS (NOT MARKED). 80 BLISTERS.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Documentation
Issued 24 January 1990 Resolved
POST THE CERTIFICATE OF INSPECTION IAW 46 CFR 176.01-40 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Construction/Loadline
Issued 24 January 1990 Resolved
REMOVE WASHDOWN HOSE THROUGH MAIN DECK AND RENEW PLASTIC ACCESS PLATE TO MAKE MAIN DECK WATERTIGHT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Engineering
Issued 24 January 1990 Resolved
MAKE SHUTOFF VALVES ON ALL 3 FUEL TANKS REMOTELY OPERABLE FROM OUTSIDE THE FUEL TANK SPACE.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Documentation
Issued 26 July 1989 Resolved
DRYDOCK DUE 14MAR90. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 26 July 1989
Resolved 26 July 1989
Engineering
Issued 7 June 1989 Resolved
REPAIR BOND FOR FWD F/O TANK.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Engineering
Issued 7 June 1989 Resolved
PROVIDE RACOR HEAT SHIELD KITS ON TWO FUEL FILTERS.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Lifesaving
Issued 7 June 1989 Resolved
PROVIDE 3/8" POLYPROPELENE PENDANTS IN 12' LENGTHS AROUND OUTER CIRCUMFERENCE AT 18" SPACES.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Construction/Loadline
Issued 7 June 1989 Resolved
PROVIDE WATERTIGHT ACCESS HATCH FOR FOREPEAK PRIOR TO NEXT SCHEDULED DRYDOCK. (14MAR90)
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Documentation
Issued 14 September 1988 Resolved
OBTAIN FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 14 September 1988
Resolved 14 September 1988
Construction/Loadline
Issued 22 August 1984 Resolved
PROVIDE SUITABLE ACCESS TO THE AREA FORWARD OF THE COLLISION BULKHEAD.
Condition: Unknown
Due 22 August 1984
Resolved 22 August 1984

Casualty record · 1

13 June 2007Routine · role: Involved in a Marine Casualty · activity 2960249
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GABRIELLA (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.