← All vessels
RIP CURRENT
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named RIP CURRENT
RIP CURRENT is a 1984 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1984, most recently in July 2026, along with 98 deficiencies, 1 operational control and 1 casualty investigation in 2007.
Records from 1984 to 2026. Most recent: inspection, 29 July 2026.
- Built
- 1984
- Last inspected
- 29 July 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 98 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2007
Identity
667476
WDB9922
230500
Flag
UNITED STATES
368229750
Maury page id
psix-230500
Inspections, by type
…with no type recorded6
Years with a record
29 calendar years (1984–2026)
The 60 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)37.4 ft × 13.6 ft × 5.8 ft
Registered tonnagegross 20 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMICHAEL FITZ CUSTOM BOATS · NAPLES, FL, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 17 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDM6972MMSI 368229750 · active · compulsorily equipped · granted 3 December 2021, expires 3 December 2031
WDB9922MMSI 366985110 · expired · compulsorily equipped · granted 22 October 2004, cancelled 27 December 2014
WCZ8936MMSI not assigned · expired · compulsorily equipped · granted 20 June 2000, cancelled 21 August 2010
WCX8059MMSI not assigned · expired · compulsorily equipped · granted 22 October 1997, cancelled 22 December 2007 · licensed under a name not among this hull’s recorded names (not shown)
WCW9755MMSI not assigned · expired · compulsorily equipped · granted 11 December 1996, cancelled 10 February 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 60
29 July 2026
Type not recorded
No type recorded · USCGC OLIVIA HOOKER (WPC 1161) · USCG Heartland District (CGD-H) · Activity 8455281
6 March 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8321168
20 May 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8126885
1 April 2025
Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 8109261
3 February 2025
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8074002
24 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7900975
23 May 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7712817
31 March 2023
Administrative Inspection · Inclining Experiment
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7660422
2 February 2023
Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631270
3 October 2022
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7571584
25 May 2022
Administrative Inspection · Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7459833
31 March 2022
In-Service Inspection · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7422386
24 February 2022
Administrative Inspection · COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7401669
8 September 2021
Administrative Inspection · Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7307713
3 February 2021
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7135099
13 June 2007
Type not recorded
No type recorded · Commandant (CG-INV) · Activity 2960249
7 June 2007
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2953143
29 March 2006
Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2611796
20 October 2005
Damage Survey · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2493086
11 May 2005
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2355197
16 February 2005
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2294060
15 February 2005
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2292746
25 October 2004
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2227708
29 June 2004
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2114697
12 August 2003
Annual Inspection · Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1873921
19 April 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465635
6 July 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1052204
23 May 2000
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1437727
21 October 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1126527
17 September 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 784899
23 April 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410076
21 May 1998
Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1418529
29 September 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1390630
23 July 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1390596
5 December 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1392605
23 July 1996
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1392604
12 September 1995
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1181503
25 May 1995
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1190222
1 June 1994
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1171905
8 June 1993
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 960709
17 July 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1257981
1 June 1992
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 949392
28 May 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 949550
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1309701
14 August 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 942269
9 July 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 940945
12 July 1990
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214234
7 June 1990
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1232681
18 April 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 906650
24 January 1990
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1238587
17 January 1990
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 918035
26 July 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1198572
7 June 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1343135
14 September 1988
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1351917
12 August 1987
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1337231
25 February 1987
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1311570
7 August 1986
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 999987
18 October 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 994509
26 September 1985
Credit Drydock · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1298819
22 August 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1282747
Deficiency record · 98
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 20 May 2025
Resolved
A durable placard must be posted next to all radiotelephone installations with emergency broadcast instructions and information, specific to the individual vessel. Top of vessel's placard was worn off and missing first step of instructions. Replace placard.
46 CFR 184.506
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 23 May 2023
Resolved
Crew members were not listed as being part of the random drug testing through vessel's drug consortium.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 31 March 2022
Resolved
Vessel prohibited from adding any type of canopy or covering to top deck pilothouse IAW COI and Stability letter. Vessel found with canopy in place. Remove covering and complete satisfactory in-service inspection.
Documentation › Certificates/Documents › FCC SSL
Issued 7 June 2007
Resolved
Provide a FCC Marine Radio Operator Permit as required by 47CFR
Operations/Management › Passenger Operations › Safety Orientation
Issued 7 June 2007
Resolved
Provide means to keep a correct written count of all passengers ashore as required by 46 CFR 185.504
Lifesaving › Hand Flares › Quantity
Issued 7 June 2007
Resolved
Provide one daytime distress signal as required by 46 CFR 180.68
Construction/Loadline › Structures › Superstructure
Issued 7 June 2007
Resolved
Replace missing glass in accommodation space as required by 46 CFR 176.800
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 June 2007
Resolved
Make aft rail meet courses of the rest of the vessel as required by 46 CFR 177.900
Lifesaving › Lifefloat › Quantity
Issued 7 June 2007
Resolved
Provide an approved lifefloat as required by 46 CFR 1800.200 Until this item is cleared by an attending Coast Guard Marine Inspector to vessel is restricted to a Lakes, Bays, and Sounds Route.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 June 2007
Resolved
Provide an approved battery for the waterlight on the lifefloat and ring life buoy as required by 46 CFR 180.70 and 180.175
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 June 2007
Resolved
Properly splice the lifeline to the ring life buoy and properly splice the lanyard for the waterlight to the non-corrosive clip as required by 46 CFR 180.70
Engineering › Fuel Oil Service System › Filter
Issued 7 June 2007
Resolved
Provide a metal plug for both fuel strainers and a strainer bowl for the port fuel strainer as required by 46 CFR 182.455
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 7 June 2007
Resolved
Tighten or repack the starboard shaft log to reduce the excessive leak as required by 46 CFR 176.800
Engineering › Bilge Water Management System › Not Installed
Issued 7 June 2007
Resolved
Properly mount the float switch for the bilge pump in the forward compartment as required by 46 CFR 182.520
Electrical › Electric Generation Source (service) › Power Requirement
Issued 7 June 2007
Resolved
Prove operation of generator as required by 46 CFR 176.500
Electrical › Electrical Distribution System (service) › Cable
Issued 7 June 2007
Resolved
Remove dead-end wires in aft part of engine room and under console in pilot house as required by 46 CFR 183.340
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 June 2007
Resolved
Properly mount the loose circuit breaker in tool room as required by 46 CFR 183.330
Documentation › Certificates/Documents › FCC SSL
Issued 29 March 2006
Resolved
Provide a FCC safety certificate.
Documentation › Logs/Records › Logbook (official)
Issued 29 March 2006
Resolved
Provide a current training logbook IAW 46 CFR 185.420
Documentation › Logs/Records › Logbook (official)
Issued 29 March 2006
Resolved
Provide a life saving equipment maintenance manual IAW 46 CFR 185.702
Documentation › Logs/Records › Logbook (official)
Issued 29 March 2006
Resolved
Provide a ships bridge logbook with all required entries IAW 46CFR 185.702
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 29 March 2006
Resolved
Provide and install retro reflective tape on the life jackets as needed IAW 46 CFR 185.604
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 29 March 2006
Resolved
Properly label the life jacket stowage area IAW 46 CFR 180.78
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 March 2006
Resolved
Provide and install machinery guards over rotating machinery in the engine room as required by 46 CFR 177.960 to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2006
Resolved
Properly install the electrical wiring connection for the anchor windless in a watertight box. 46CFR 183.210
Stability › Watertight Integrity › General
Issued 29 March 2006
Resolved
Provide and install a new dog for the port light in the accommodation space. 46 CFR 179.350
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 March 2006
Resolved
Replace cracked lens on both port and starboard running lights. IAW 46 CFR 176.800
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 March 2006
Resolved
Properly secure and provide illumination for the magnetic compass IAW 46 CFR 184.402
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 29 March 2006
Resolved
Properly secure the water light to the lifefloat IAW 46 CFR 180.175
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2006
Resolved
Remove dead ended electrical wiring in the engine room IAW 46 CFR 183.340
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2006
Resolved
Secure all electrical wiring in the engine room IAW 183.340
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 March 2006
Resolved
Prove the rails on the aft deck to meet the height requirement in 46 CFR 177.35-1
Electrical › Electrical Distribution System (service) › Switchboard
Issued 29 March 2006
Resolved
Provided and install a volt and frequency meter at the control panel for the ship service generator IAW 46 CFR 183.10-5
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 16 February 2006
Resolved
Provide proper anchor 46CFR184.300
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 16 February 2006
Resolved
Properly secure starboard propeller to shaft (Key) 46 CFR 176.630
Construction/Loadline › Structures › Superstructure
Issued 16 February 2006
Resolved
Make proper repairs to cracking of bulwarks on stbd side. 46CFR176.800
Construction/Loadline › Hull › Hull Plating
Issued 16 February 2006
Resolved
Make repairs to blister on hull, inboard of port fwd strut. 46CFR176.800
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 February 2006
Resolved
Make proper repairs to loose rails.46CFR177.900
Construction/Loadline › Structures › Door
Issued 16 February 2006
Resolved
Repair 2 cracked windows on main cabin, one on port side, one on starboard. 46CFR176.800
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 16 February 2006
Resolved
Make proper repairs to anchor guide system, replace guide bolt.46CFR184.300
Lifesaving › Lifejacket/PFD (Type II) › Marking
Issued 15 April 2005
Resolved
Mark lifejackets with vessel's name in accordance with 46 CFR 185.604.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 April 2005
Resolved
Repair or renew sternlight as per 72 COLREGS to the satisfaction of the attending marine inspector..
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 15 April 2005
Resolved
Prove proper operation of shutdown of engines, generator, and power ventilation as required by 46 CFR 182.465(h).
Construction/Loadline › Hull › Side Shell
Issued 28 February 2005
Resolved
Repair 55 areas of blistering/delamination of bottom and side shell fiberglass reinforced plastic hull noted during hull examination in accordance with NVIC 8-87 to the satisfaction of the attending marine inspector.
Construction/Loadline › Hull › Side Shell
Issued 28 February 2005
Resolved
Repair 9 holes in hull along the chine in accordance with NVIC 8-87 to the satisfaction of the attending marine inspector.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 28 February 2005
Resolved
Renew worn cutlass bearings on port/starboard shafts to the satisfaction of the attending marine inspector.
Lifesaving › Hand Flares
Issued 26 August 2003
Resolved
Provide six hand held smoke distress signals approved IAW 160.037 as required by 46 CFR 180.68(a)(2). LEGACY COMPONENT DESC: Quantity
Lifesaving › Hand Flares
Issued 26 August 2003
Resolved
Provide six red flare distress signals approved IAW 160.021 as per 46 CFR 180.68(a)(1). LEGACY COMPONENT DESC: Quantity
Engineering › Fuel Oil Service System
Issued 26 August 2003
Resolved
Remount generator F/O flex hose and provide proper support IAW 46 CFR 182.20-40(b)(2). LEGACY COMPONENT DESC: Hose
Engineering › Sea-water System (primary cooling)
Issued 26 August 2003
Resolved
Replace saltwater flex hose on both main diesel engines going to heat exchanger from raw water pump. LEGACY COMPONENT DESC: Piping
Unknown
Issued 23 May 2000
Resolved
PROVIDE SATISFACTORY DOCUMENTATION THAT THE MARINE EMPLOYER HAS AN ESTABLISHED CHEMICAL TESTING PROGRAM AS IDENTIFIED IN 46 CFR PART 16. PROVIDE DOCUMENTATION TO MSO NEW ORLEANS DAPI OFFICER [phone withheld].
Lifesaving
Issued 23 May 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline
Issued 23 May 2000
Resolved
PROPERLY REMOVE ALL EXCESS OILY SLOPS FROM BILGE SPACES.
Construction/Loadline
Issued 23 May 2000
Resolved
PROVIDE PROPER AUDIBLE ALARM FOR BILGE HIGH WATER ALARM.
Fire Fighting
Issued 23 May 2000
Resolved
PROVIDE VISUAL AND AUDIBLE DISCHARGE ALARM AT OPERATING STATION FOR FIXED FF SYSTEM IAW 46 CFR 181.420.
Lifesaving
Issued 23 May 2000
Resolved
PROVIDE 03 SMOKE DISTRESS SIGNALS.
Construction/Loadline
Issued 23 May 2000
Resolved
RENEW DAMAGED BILGE SYSTEM PIPING IN MACHINERY SPACE.
Lifesaving
Issued 23 May 2000
Resolved
PROVIDE PROPER EPIRB HYDROSTATIC RELEASE. VESSEL IS RESTRICTED TO OPERATIONNOT MORE THAN 03 MILES FROM SHORE UNTIL THIS ITEM IS CLEARED.
Fire Fighting
Issued 23 May 2000
Resolved
PROVIDE CURRENT SERVICING REPORT FOR ALL PORTABLE FIRE EXTINGUISHERS AND FIXED FF SYSTEM.
Engineering
Issued 23 May 2000
Resolved
PROVIDE METAL FIRE BOWL FOR GENERATOR FUEL FILTER.
Documentation
Issued 23 May 2000
Resolved
PROVIDE VALID FCC RADIO STATION LICENSE.
Unknown
Issued 23 April 1999
Resolved
INSTALL FIXED FIRE FIGHTING SYSTEM IN ENG ROOM.
Lifesaving
Issued 29 September 1997
Resolved
Provide emergency broadcast placard.
Lifesaving
Issued 29 September 1997
Resolved
Provide drug testing program as required by 46 C.F.R. 16.
Lifesaving
Issued 29 September 1997
Resolved
Provide emergency drills and log same.
Fire Fighting
Issued 25 May 1995
Resolved
Service 2 B-II fire extinguishers prior to operating.
Lifesaving
Issued 25 May 1995
Resolved
Label adult and child pfd stowage on main deck.
Engineering
Issued 25 May 1995
Resolved
Install flame shields on 2 racor filters.
Lifesaving
Issued 25 May 1995
Resolved
Repair ringbuoy and lifefloat waterlights.
Lifesaving
Issued 25 May 1995
Resolved
Renew 15 man lifefloat.
Construction/Loadline
Issued 25 May 1995
Resolved
Re-install aft deck hatch.
Lifesaving
Issued 25 May 1995
Resolved
Renew ringbuoy or repair lines, also renew 60' line.
Lifesaving
Issued 25 May 1995
Resolved
Renew flares prior to operation.
Navigation
Issued 25 May 1995
Resolved
Repair mast head light prior to operating.
Electrical
Issued 25 May 1995
Resolved
Permanently mount battery switch.
Navigation
Issued 1 June 1992
Resolved
Repair radar
Lifesaving
Issued 1 June 1992
Resolved
Repair waterlight for ring buoy. Vessel limited to daylight operation until complete.
Engineering
Issued 1 June 1992
Resolved
REPAIR EMERGENCY FUEL SHUTOFF VALVE CABLES FOR FORWARD TANK.
Electrical
Issued 1 June 1992
Resolved
Clean corrosion from battery terminals.
Documentation
Issued 1 June 1992
Resolved
Provide copy of FCC certificate.
Navigation
Issued 9 July 1991
Resolved
REPAIR STBD SIDELIGHT & STERN LIGHT PRIOR TO CARRYING PASSENGERS AND NO LATER THATN 16JUL91.
Engineering
Issued 9 July 1991
Resolved
RESTENCIL FORWARD FUEL TANK EMERGENCY SHUTOFF PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 16JUL91.
Lifesaving
Issued 9 July 1991
Resolved
REPAIR WATERLIGHT FOR LIFEFLOAT PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 16JUL91.
Engineering
Issued 9 July 1991
Resolved
REPLACE CABLE ON PORT FUEL TANK EMERGENCY SHUTOFF PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 16JUL91.
Construction/Loadline
Issued 7 June 1990
Resolved
GRIND ALL MARKED BLISTERS TO GOOD FIBERGLASS (NO DELAMINATION). 68 BLISTERS
Construction/Loadline
Issued 7 June 1990
Resolved
REGLASS AS ORGINAL THE BLISTERS IN REQUIREMENT #1.
Engineering
Issued 7 June 1990
Resolved
INSTALL FLAME SCREEN ON PORT AFT FUEL TANK VENT.
Construction/Loadline
Issued 7 June 1990
Resolved
EPOXY OTHER BLISTERS (NOT MARKED). 80 BLISTERS.
Documentation
Issued 24 January 1990
Resolved
POST THE CERTIFICATE OF INSPECTION IAW 46 CFR 176.01-40 PRIOR TO CARRYING PASSENGERS.
Construction/Loadline
Issued 24 January 1990
Resolved
REMOVE WASHDOWN HOSE THROUGH MAIN DECK AND RENEW PLASTIC ACCESS PLATE TO MAKE MAIN DECK WATERTIGHT PRIOR TO CARRYING PASSENGERS.
Engineering
Issued 24 January 1990
Resolved
MAKE SHUTOFF VALVES ON ALL 3 FUEL TANKS REMOTELY OPERABLE FROM OUTSIDE THE FUEL TANK SPACE.
Documentation
Issued 26 July 1989
Resolved
DRYDOCK DUE 14MAR90. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Engineering
Issued 7 June 1989
Resolved
REPAIR BOND FOR FWD F/O TANK.
Engineering
Issued 7 June 1989
Resolved
PROVIDE RACOR HEAT SHIELD KITS ON TWO FUEL FILTERS.
Lifesaving
Issued 7 June 1989
Resolved
PROVIDE 3/8" POLYPROPELENE PENDANTS IN 12' LENGTHS AROUND OUTER CIRCUMFERENCE AT 18" SPACES.
Construction/Loadline
Issued 7 June 1989
Resolved
PROVIDE WATERTIGHT ACCESS HATCH FOR FOREPEAK PRIOR TO NEXT SCHEDULED DRYDOCK. (14MAR90)
Documentation
Issued 14 September 1988
Resolved
OBTAIN FCC RADIO SAFETY CERTIFICATE.
Construction/Loadline
Issued 22 August 1984
Resolved
PROVIDE SUITABLE ACCESS TO THE AREA FORWARD OF THE COLLISION BULKHEAD.
Casualty record · 1
13 June 2007Routine · role: Involved in a Marine Casualty · activity 2960249
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
GABRIELLA (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.