MAURY USCG vessel records Sign in
← All vessels

WEST REEF

WEST REEF is a 1955 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 1985, most recently in July 2009, along with 23 deficiencies.

Records from 1985 to 2009. Most recent: inspection, 19 July 2009.

Built
1955
Last inspected
19 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WXF4771
230609
Flag
UNITED STATES
—
Maury page id
psix-230609

Inspections, by type

…with no type recorded3
Years with a record 24 calendar years (1985–2009)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it7 - Regulatory (Subpart C or D), Net Ton
11 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 34

19 July 2009 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3570468
6 June 2008 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3228780
1 May 2007 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2919695
5 October 2006 Simplified Stability Test · Hull Examination · Plan Review "T" Boat
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2794482
26 July 2006 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2725443
5 June 2006 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2671054
14 June 2005 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2390489
2 September 2004 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2199964
27 July 2004 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2146398
2 June 2004 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2084954
2 July 2003 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1826329
14 May 2002 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1617419
3 May 2001 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1418897
5 May 2000 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1468574
12 April 1999 Plan Review "T" Boat · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 787208
26 May 1998 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 791841
21 July 1997 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1378181
21 May 1997 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1107774
9 May 1997 Hull Examination · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1413160
17 April 1996 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1374631
18 May 1995 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1187907
21 April 1994 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1431347
22 April 1993 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 830031
19 May 1992 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 951744
16 April 1992 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 947952
7 May 1991 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 926371
27 June 1990 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 908065
3 May 1990 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 907056
30 May 1989 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1039339
10 May 1988 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1347383
17 June 1987 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1005797
14 May 1987 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1027003
21 April 1987 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1023764
4 October 1985 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 985183

Deficiency record · 23

Lifesaving › Buoyant Apparatus › Not on Board
Issued 1 May 2007 Resolved
Install new 25 man B/A for updated passenger count.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2007
Resolved 1 May 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 May 2007 Resolved
Replace outdated hydro release for EPIRB.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2007
Resolved 1 May 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 1 May 2007 Resolved
Install plugs in de-icing valves.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2007
Resolved 1 May 2007
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 1 May 2007 Resolved
Update current life jacket count on both storage boxes.
Condition: Placed in Improper Service
Due 30 May 2007
Resolved 5 June 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 May 2007 Resolved
Have all extinguishers (3) annually serviced by 5/30/07 when current inspection date expires.
Condition: Improper/Lack of Maintenance
Due 30 May 2007
Resolved 5 June 2008
Navigation › Piloting/Steering › Magnetic Compass
Issued 1 May 2007 Resolved
Rewire compass light to work properly.
Condition: Improper/Lack of Maintenance
Due 30 May 2007
Resolved 5 June 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 May 2007 Resolved
Properly attach battery box cover.
Condition: Improper Installation
Due 30 May 2007
Resolved 5 June 2008
Stability › Watertight Integrity › General
Issued 1 May 2007 Resolved
Install watertight hatch on steering compartment.
Condition: Design Flaw
Due 30 May 2007
Resolved 5 June 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 June 2006 Resolved
Raise anchor light as per Navigation Rules
Action required: 705 - Other - as specified
Due 1 January 2007
Resolved 5 June 2008
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 5 June 2006 Resolved
Leaky fuel return on #4 injector. (Very minor, no drips, opposite side from any hot spots on the opposing piston engine.
Due 23 August 2006
Resolved 23 August 2006
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 5 June 2006 Resolved
Tighten or replace fresh water pump belt.
Due 23 August 2006
Resolved 30 August 2006
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 5 June 2006 Resolved
Double hose clamp all raw water circuit after the raw water pump.
Due 23 August 2006
Resolved 30 August 2006
Lifesaving › Lifefloat › Markings
Issued 5 June 2006 Resolved
Stencil lifefloat.
Due 23 August 2006
Resolved 30 August 2006
Lifesaving › Lifefloat › Paddle
Issued 5 June 2006 Resolved
Add paddles to lifefloat.
Due 30 August 2006
Resolved 30 August 2006
Engineering › Bilge Water Management System › Pump
Issued 2 June 2004 Resolved
Ensure bilge pumps are U. L. aprroved.
Due 23 August 2004
Resolved 2 September 2004
Engineering › Bilge Water Management System › Pump
Issued 2 June 2004 Resolved
Install visual indicator at operating station for automatic bilge pump.
Due 2 July 2004
Resolved 3 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 June 2004 Resolved
Install metal wire ties/ holders and remove all plastic wire ties used as supports.
Due 2 July 2004
Resolved 3 August 2004
Lifesaving › Buoyant Apparatus
Issued 14 May 2002 Resolved
MAXIMUM NUMBER OF PASSENGERS ALLOWED ON BOARD IS LIMITED TO 19, AND TOTAL PERSONS ON BOARD IS LIMITED TO 20, UNTIL AN APPROVED LIFE FLOAT WITH A MINIMUM CAPACITY OF 11 PERSONS IS PLACED ON BOARD. LEGACY COMPONENT DESC: LIFE FLOAT
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 6 August 2002
Resolution: OPERATOR DOES NOT INTEND TO PROVIDE A LARGER LIFE FLOAT AT THIS TIME/NEAR FUTURE, ISSUE NEW COI WITH MAX PASSENGERS ALLOWED 19, 20 TOTAL PERSONS ALLOWED.
Engineering
Issued 9 May 1997 Resolved
CROP/RENEW AFT. "V" STRUT TAILSHAFT BEARING HOUSING. SEVERLY WASTED. EFFECT REPAIRS PRIOR TO PUTTING VESSEL BACK IN SERVICE. NOTIFY [name withheld] ARE COMPLETE.
Condition: Unknown
Due 20 May 1997
Resolved 30 May 1997
Lifesaving
Issued 17 April 1996 Resolved
REPLACE 6 HAND HELD RED FLARES AND 6 HAND HELD ORANGE SMOKE SIGNALS.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Navigation
Issued 17 April 1996 Resolved
REPAIR OR REPLACE STERN LIGHT FIXTURE.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Construction/Loadline
Issued 3 May 1990 Resolved
MAKE PERMANENT REPAIRS TO THE MAIN ENGINE SEA SUCTION LINE BY HARD PIPING THE CONNECTION BETWEEN THE HULL AND THE SEA VALVE.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Unknown
Issued 14 May 1987 Resolved
REMOVE EXISTING INSULATION FROM ENGINE COMPARTMENT
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.