EDITH M BECKER

EDITH M BECKER is a 1984 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1984, most recently in June 2026, along with 150 deficiencies and 1 casualty investigation in 2005.

Records from 1984 to 2026. Most recent: inspection, 30 June 2026.

Built
1984
Last inspected
30 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG4122
230850
Flag
UNITED STATES
369300000 (licence lapsed)
Maury page id
psix-230850

Inspections, by type

…with no type recorded8
Years with a record 36 calendar years (1984–2026)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.0 ft × 14.5 ft × 6.7 ft
Registered tonnagegross 22 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHERB SMITH · LITTLETON, NH, UNITED STATES · built 1984
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeSail (Faired Keel)
Hull configurationMonohull
Hailing portSISTER BAY, WI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG4122MMSI 369300000 · expired · compulsorily equipped · granted 1 June 2012, cancelled 6 August 2022
WDB4591MMSI 369300000 · cancelled · compulsorily equipped · granted 30 June 2003, cancelled 30 May 2012
WCY5220MMSI not assigned · expired · voluntarily equipped · granted 1 July 1998, cancelled 6 September 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 78

30 June 2026 Annual Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8420579
23 June 2025 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8160606
25 April 2025 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8120314
1 August 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7972583
22 May 2024 In-Service Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7971849
26 June 2023 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7724418
17 May 2023 Special Consideration
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7736363
10 May 2022 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7458147
4 May 2022 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7458110
16 February 2022 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7397188
29 June 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7239097
1 July 2020 Examination of Repairs · Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7005889
27 May 2020 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6963533
8 July 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6742288
1 July 2019 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6732161
22 June 2019 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6724265
13 June 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6713215
13 June 2018 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6444398
26 January 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6562384
10 January 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6371235
9 May 2017 Deficiency Check · COI Inspection · Examination of Repairs · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6166410
14 September 2016 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6000875
22 June 2016 Examination of Repairs · Plan Review "T" Boat · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5931689
25 April 2016 Damage Survey · Examination of Repairs · Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5892437
24 August 2015 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5232538
22 July 2015 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5212015
27 July 2012 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4392352
14 June 2012 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4336753
15 July 2011 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4120372
13 July 2011 COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4080810
2 October 2008 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3337015
4 June 2008 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3228119
7 May 2008 Periodic Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3200691
4 June 2007 Re-Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2951364
10 July 2006 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2707726
2 October 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2507630
17 August 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2465614
18 May 2005 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2361051
8 June 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2149264
1 July 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1960550
21 May 2003 Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1798475
17 September 2002 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1676261
10 July 2001 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1472989
2 July 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1408779
14 May 1998 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1125838
15 October 1997 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1110805
9 July 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 778413
19 November 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1388177
7 May 1996 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1083802
7 December 1995 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 872948
31 October 1995 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1193517
11 May 1995 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 871041
12 July 1994 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1175479
28 April 1994 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1168903
21 October 1993 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1155660
1 June 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 73859
10 May 1993 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1141992
15 April 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1255641
25 March 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 952314
27 March 1991 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 901237
27 March 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 903348
25 February 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1228750
28 November 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 914204
7 September 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 905461
8 April 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1225298
15 March 1990 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1231675
20 February 1990 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1232307
18 May 1989 Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1277195
27 March 1989 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1209795
12 May 1988 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1349839
10 May 1988 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1039932
12 May 1987 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1022252
7 May 1987 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1019213
28 August 1986 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1322877
14 August 1986 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1293929
16 May 1986 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 996562
14 May 1986 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1304426
22 June 1984 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 980670

Deficiency record · 150

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2025 Resolved
Life jacket stowage was not marked with number and size of pfds.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 8 July 2025
Resolution: Operator sent photographs of newly installed signage with numerical count for adults/child pfds.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 June 2025 Resolved
EPIRB battery expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 8 July 2025
Resolution: Vessel operator sent photos and videos of new battery, installing the battery, and performing a test of the EPIRB.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 June 2025 Resolved
MMSI not listed on FCC documentation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 8 July 2025
Resolution: Vessel operator emailed new FCC documentation with MMSI
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 June 2025 Resolved
Fire buckets exceeded 2.5 gallon capacity.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 8 July 2025
Resolution: Vessel operator provided evidence of drilling holes into the 5 gallon buckets at the halfway point to prevent overloading.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 23 June 2025 Resolved
The vessel did not have a current Preventative Maintenance Plan IAW NVIC 02-16 for sail rigging.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 8 July 2025
Resolution: Operator sent updated PMP with evidence of recent rig survey by crew.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 August 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from with the protected space. Unable to verify servicing of shutdowns or conduct test of the shutdowns due to the arrangement of the system. Vessel to conduct servicing of the system to verify shutdowns, and carry 02 40-B;C portable fire extinguishers until servicing is conducted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2024
Resolution: Fire servicing tech attended vessel, verified shutdowns. Operator was able to demonstrate the tests. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 August 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB hydrostatic release was expired. Vessel restricted to less than 3 nm from shore until hydrostatic release is renewed.
Action required: 705 - Other - as specified
Resolved 16 September 2024
Resolution: Vessel renewed hru on EPIRB.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2024 Resolved
Fuel shutoff valves shall be fitted to the fuel supply lines, at the tank connections, which shall be operable from outside the tank compartment. Remote fuel shut off disconnected from the shut off valve due to improper operation. Vessel temporarily secured reach rod to valve to demonstrate closure. Make permanant repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2024
Resolution: Permanent connection was made to the reach rod to ensure it would not seperate. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2024 Resolved
Remote fuel shutoff stations shall be marked indicating the direction of operation. Valve was not marked resulting in its disconnection from the fuel shut off valve. Mark fuel shut off with at least 1 inch lettering.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2024
Resolution: Marked correctly. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 August 2024 Resolved
A vessel on Great Lakes route must carry 6 hand red flares and 6 hand smoke flares or 12 combination flares. Vessel did not have flares available on board at the time of the inspection. Ensure vessel has the correct number of flares for the route.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2024
Resolution: Vessel rep sent photographs of 12 flares on board the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 August 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Visual indicator was extinguished. Conduct necessary repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2024
Resolution: Received video from vessel representative indicating fully operational bilge alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2024 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2024
Resolution: Verified operator had properly seperated and marked lifejacket stowage.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 August 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. The testing strips on board were expired. Renew testing strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2024
Resolution: New strips provided onboard. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2024 Resolved
Placards containing instructions for the donning and use of the life jackets on board must be posted in conspicuous locations. Vessel has two styles of life jackets; and is missing instruction for one of the styles.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2024
Resolution: Received images from vessel representative of additional pfd style placard mounted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 August 2024 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather deck accessible to crew and passengers. Numerous stanchions were loose. Conduct necessary repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2024
Resolution: Stanchions tighten. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 1 August 2024 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and inflates automatically. Vessel's painter line attached to life raft was not properly routed through weak link. Painter line was rerouted to be properly functional.
Action required: 10 - Deficiency Rectified
Resolved 1 August 2024
Resolution: Advised crew of the operations of the hydrostatic release unit, and verified the proper installation of the painter line.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2024 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Action required: 10 - Deficiency Rectified
Resolved 1 August 2024
Resolution: Vessel rep purchased new buckets, labeled, and installed lanyards. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2024 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation. Vessel's waterlight was inoperable.
Action required: 10 - Deficiency Rectified
Resolved 1 August 2024
Resolution: Vessel rep purchased a new waterlight with an approved corresponding battery. All Sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 August 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit contained several expired items, crew replaced prior to USCG MI's departure.
Action required: 10 - Deficiency Rectified
Resolved 1 August 2024
Resolution: Vessel rep purchased new medicines for kits. All Sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 June 2023 Resolved
Vessel's FCC's Radio Station Licenses expired. Certificate to be renewed as required by 47 CFR Part 80 on or before July 13th, 2023
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2023
Resolved 7 July 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 June 2021 Resolved
Life raft servicing certificate was not available for inspection, provide copy of life raft servicing certificate. 46 CFR 185.730
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 6 July 2021
Resolution: Life raft service report received and reviewed, reflected last annual inspection on April 13, 2021. Requirement satisfied and cleared.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 June 2021 Resolved
Several items in the first aid kit were expired. Required o/o to replace items as needed IAW contents listed in CFR. 46 CFR 160.041-4(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 10 January 2022
Resolution: verified with O/O that items were replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 June 2021 Resolved
Alcohol test strips required for DAPI were expired. Required O/O to replace. 46 CFR 16.240
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 12 July 2021
Resolution: E-mail with Photos received reflected 24 Alcohol test strips procured, with expiration date May 09, 2023. Requirement satisfied and cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 June 2021 Resolved
During inspection of the main mast MI noted what appeared to be rotten wood right above the gooseneck for the main boom. O/O will have shipwright ([name withheld]) come look at the mast while he also inspects some of the padeyes for repair. 46 CFR 177.330
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 July 2021
Resolved 25 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 July 2020 Resolved
Vessels Chart missing. Required O/O to obtain locate and or replace missing navigational chart(s) for areas where vessel operates.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2020
Resolved 14 July 2020
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 July 2020 Resolved
Reviewed official log book, entries for July, Aug, & September 2019 did not reflect EPIRB was tested monthly. CG-835 issued requiring O/O or Master to test & log monthly EPIRB inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 6 August 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2020 Resolved
Chemical testing documentation not available for Master. O/O required to submit documentation reflecting Master passed and enrolled in companies chemical testing program.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 17 July 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 July 2020 Resolved
Provide a photo reflecting repair of the main mast new scarf.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 24 July 2020
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 1 July 2020 Resolved
Reviewed official log book, entries for July, Aug, & September 2019 did not reflect required monthly Fire & Abandon Ship drills. CG-835 issued requiring O/O or Master to conduct & log monthly Fire & Abandon ship drills.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 6 August 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2020 Resolved
Noted chemical testing report reflected prior master tested positive during a random test on Oct, 22, 2019. Inquired if O/O reported to CG. O/O stated he did not, stated random discovered after vessels operating season & that prior master was informed he would not be hired during vessels next operating season. Informed O/O per 46 CFR 16, he was required to report to CG. Follow-up with Sector IO reflected he was aware of individuals’ positive test & working with the Mariner.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 14 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2019 Resolved
Starboard side MCT navigation light is not watertight and the wire is damaged. Electrical equipment exposed to weather must be watertight. Repair/replace MCT and damaged wire.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 8 July 2019
Resolution: MCT has been sealed and wire has been replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2019 Resolved
Vessel is required 3 B-II fire extinguishers per COI. Vessel only has 2 working fire extinguishers that are size B-II. Provide additional B-II extinguisher (equivalent 2A).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2019
Resolved 23 June 2019
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 22 June 2019 Resolved
Berthing reading lights pose electrical hazard. Remove all berthing reading lights and associated wiring.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2019
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 22 June 2019 Resolved
Remove and replaced damaged wiring in port berthing area. Circuits shall be locked and tagged out at the breaker panel until wiring is replaced.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2019
Resolved 1 July 2019
Resolution: Wiring has been replaced.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 17 June 2019 Resolved
EPIRB battery Expired. Renew EPIRB Battery. Vessel limited to within three miles from shore until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 1 July 2019
Resolution: EPIRB Battery has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2019 Resolved
Ring Buoy light not operable. Correct. Vessel limited to daylight operations until correct.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 1 July 2019
Resolution: Ring buoy light has been replaced and is operable.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 June 2019 Resolved
Life raft hydrostatic release, expiration date not marked. Max year date 2019. Renew life raft hydrostatic release, & mark expiration date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 1 July 2019
Resolution: Hydrostatic release has been replaced and is expiration date is properly marked.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 June 2019 Resolved
Great Lake light list outdated, 2016. Replace existing Great Lake light list with most updated edition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 1 July 2019
Resolution: 2019 Light List is onboard.
10 - Safety of Navigation › N/A - No Subsystem › Type approval equipment
Issued 17 June 2019 Resolved
Renew expired alcohol saliva test strips, expired May 31, 2019.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 1 July 2019
Resolution: New test strips are onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 June 2019 Resolved
Missing one fire bucket, and existing two fire buckets capacity of 2 gallons. Fit vessel with three fire buckets, at least 2.5 gallons. All fitted with adequate lanyards and stenciled Fire Bucket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 1 July 2019
Resolution: Vessel has 3 fire buckets with lanyards and properly marked.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 June 2019 Resolved
Obtain & fit vessel with air vent closing devices for the engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 1 July 2019
Resolution: Vessel is fitted with air vent closing devices.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2019 Resolved
Check all railing support station foundations, where loose tighten.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 1 July 2019
Resolution: Stanchion foundations were repaired.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 June 2018 Resolved
Ring buoy floating waterlight lanyard was not between 3-6 feet and not secured around the body of the ring buoy. Properly secure waterlight around ring buoy and ensure lanyard is of sufficient length.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2018
Resolved 27 June 2018
Resolution: Ring buoy was properly attached to ring buoy and lanyard was of required length.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 June 2018 Resolved
Unable to conduct drills due to weather. Complete drills in the presence of a CG MI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2018
Resolved 27 June 2018
Resolution: Drills were completed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 June 2018 Resolved
Pre-engineered system has not been operationally inspected by servicing company. Provide operational inspection report to CGMI.7dys.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 June 2018
Resolved 21 June 2018
Resolution: Fire Servicing Company attended vessel and conducted testing of the pre-engineered system. Report provided.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 13 June 2018 Resolved
Bilge Pump electrial wires were not properly secured and laying in bilge. Properly secure wiring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2018
Resolved 27 June 2018
Resolution: Electrical wires were properly secured.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 June 2018 Resolved
Vessel does not have alcohol testing equipment on board for use. Provide approved means for CG testing requirements.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2018
Resolved 27 June 2018
Resolution: Alcohol testing equipment was on board.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 13 June 2018 Resolved
Company has not submitted last years MIS reports to the CG as required. Submit MIS report within 2 weeks.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2018
Resolved 27 June 2018
Resolution: Report submitted.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 16 June 2017 Resolved
Required EAP information not Displayed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 19 July 2017
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 16 June 2017 Resolved
EAP Policy Statement not available.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 19 July 2017
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 16 June 2017 Resolved
EAP Hotline Number was not Posted
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 19 July 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 June 2017 Resolved
No documentation reflecting supervisor received one hour of EAP training.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 19 July 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 June 2017 Resolved
No documentation reflecting employer has a substance abuse professional (SAP) name and contact information
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 19 July 2017
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 16 June 2017 Resolved
No documentation reflecting a MIS report was submitted by March 15, 2017
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 19 July 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 June 2017 Resolved
A copy of the latest MIS form, or Consortium letter stating report was filled for the employer, was unavailable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 19 July 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 June 2017 Resolved
A copy of the contract or proof of enrolment in a Consortium was unavailable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 19 July 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 June 2017 Resolved
Noted several items expired in the first aid kit. Inventory items, verify compliant with 46 CFR 160.04 and renew all expired items.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 16 June 2017
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 7 June 2017 Resolved
Charts outdated. Update or obtain new charts for Lake Michigan waters per 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 16 June 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 June 2017 Resolved
Noted looses fasteners supporting life rail station. Properly secure all loose fasteners per 46 CFR 177.900
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 16 June 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 7 June 2017 Resolved
Documentation unavailable to verify compliance with chemical testing requirements IAW 46 CFR part 16. Make all chemical testing available to attending CG MI and complete a Chemical testing compliance audit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 16 June 2017
Resolution: With O/O conducted a Chemical Testing program Compliance Audit. Several areas were none compliant.
Communications › Radio Communications › EPIRB
Issued 7 June 2017 Resolved
EPIRB registration decal was not fixed to the EPIRB. Locate and place current registration decal on the EPIRB per 46 CFR 180.64 & 185.702
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 20 June 2017
Resolution: Received an e-mail with photo attached reflecting valid decal was attached to the EPIRB
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 7 June 2017 Resolved
Life raft hydrostatic release was not installed and missing. Procure an approved Life raft hydrostatic release and install per manufacture instructions per 46 CFR 180.130
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 16 June 2017
Resolution: Attended and verified
Lifesaving › Lifebuoys › Serviceable
Issued 7 June 2017 Resolved
Observed lifelines on both ring buoys were worn. Renew both ring buoy lifelines per 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 16 June 2017
Resolution: Attended vessel verified proper repairs
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 7 June 2017 Resolved
Vessels name note marked on four adult life jackets. [name withheld] jackets with vessels name per 46 CFR 180.71. Corrected and verified before CG MI’s departed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2017
Resolved 7 June 2017
Resolution: Verified corrected prior to completing the exam.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 7 June 2017 Resolved
Observed three adult life jackets marked “Appledoor III” Cross/blacken out and mark with vessels name per 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2017
Resolved 7 June 2017
Resolution: Corrected and verified before CG MI’s departed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 June 2017 Resolved
Aft lifejacket stowage compartment, marked with an excessive number. Relabeled the life jacket stowage compartment to reflect proper number of life jackets per 46 CFR 180.78
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 16 June 2017
Resolution: Attended vessel and verified
Construction/Loadline › Penetrations › Gasket
Issued 7 June 2017 Resolved
Noted several main deck stuffing tubes were open or not properly sealed. Where stuffing tubes open or not caulked, re-caulk and seal per 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 16 June 2017
Resolution: Attended and verified stuffing tubes were resealed
Sail Rigging › Deck Hardware › Boom Vang
Issued 7 June 2017 Resolved
Observed de-lamination of the staysail boom. Make proper repairs to re laminate staysail boom or renew as required per 46 CFR 184.300
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 16 June 2017
Resolution: Attended and verified proper repairs
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 5 August 2016 Resolved
Newly installed exhaust anti-stipend loop, observed intermittently spitting water from the vent. Installation unacceptable and required to be corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 5 August 2016
Resolution: The anti-stipend loop was replaced and thereafter operated as designed without water discharging from the vent.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 August 2016 Resolved
Unable to confirm the engine could restart after activation of the newly installed fixed Fire Boy extinguishing unit. O/O to correct and demonstrate proper operation of the Fire Boy Engine Shutdown/Override System.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 15 August 2016
Resolution: Sister Bay Yacht Works called rep tested & verified proper operation, requirement cleared
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 5 August 2016 Resolved
Exhaust gas back pressure; check at all speeds and verify within manufactures limits (max 3.4 psi) per 46 CFR 182.200.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 15 August 2016
Resolution: Ship yard rep checked, at all speeds max exhaust pressure 3.0 psi Found to be within mfg limits
Documentation › Logs/Records › Record Book of Engine Parameters
Issued 5 August 2016 Resolved
Provide the YANMAR engine installation pressures and temperatures readings to confirm all within manufactures limits per 46 CFR 182.200.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 15 August 2016
Fire Fighting › Combustible Materials › Insulation
Issued 5 August 2016 Resolved
Modify, fit and install noncombustible insulation on the interior side of the engine cover per 46 CFR 177.410(c)(4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 14 September 2016
Resolution: Vessel installed non-combustible insulation material on engine cover.
Sail Rigging › Chainplates › Materials
Issued 9 July 2016 Resolved
Per [name withheld] 2016 3rd Party Rigging Survey Report, make repairs to the exposed wood in way of the starboard chain plate under the wooden rub rail.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 14 July 2016
Resolution: Attended vessel, viewed and verified satisfactory repairs
Sail Rigging › Mast Step › Mast Partners
Issued 30 June 2016 Resolved
O/O shall provide an independent 3rd party surveyor report, which addresses the condition of the vessels rigging and the delamination, checking and cracks on the Fore & main Masts. During the 3rd party surveyor’s attendance, a CG Marine Inspector must be contacted and present
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 14 July 2016
Resolution: Attended vessel, O/O provided a 3rd parties rigging survey report
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 June 2016 Resolved
Observed CG Light List for the Great Lakes was outdated. Obtain a new CG Light List for the Great Lakes per 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 24 June 2016
Resolution: Received an e-mail from vessel rep with photos and statements reflecting a Great Lake Light List was obtained
Navigation › Piloting/Steering › US Coast Pilot
Issued 22 June 2016 Resolved
Observed U.S. Coast Pilot for the Great Lakes was outdated. Obtain a new U.S. Coast pilot for the Great Lakes per 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 6 July 2016
Resolution: Received an e-mail from vessel rep, statement & attached photo reflected compliance
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 June 2016 Resolved
Observed four adult life jackets retro reflective tape was worn. Renew retro-reflective tape or renewed the four life jackets per 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 24 June 2016
Resolution: Received an e-mail with photos, reflecting retro-reflective tape was renewed on four life jackets.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 22 June 2016 Resolved
Monthly checks of the vessels EPIRB, Survival Craft, Life Saving & Fire Fighting Equipment were not documented. Per 46 CFR 185.728/702/524/520 monthly, inspect and log equipment was inspected and tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2016
Resolved 22 June 2016
Resolution: O/O inspected and documented inspections
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 22 June 2016 Resolved
Aft bilge alarm was not operational. Make repairs and demonstrated proper operator of the aft bilge alarm per 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2016
Resolved 22 June 2016
Resolution: Resolved and verified prior to CG MI departure
Sail Rigging › Mast Step › Mast Partners
Issued 22 June 2016 Resolved
Evaluate, measure and document (with photos) areas of delaminating and checking on the Fore & Main Mast per 46 CFR 176.840. Submit finding/report to attending CG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 28 June 2016
Resolution: O/O inspected, documented finding and submitted report to CG MSD Sturgeon Bay MI
Sail Rigging › Mast Step › Mast Partners
Issued 22 June 2016 Resolved
Owner/Operator & Master shall monitor areas of delamination on the Mainmast at least once a week, or more frequently if vessel operated in strong winds or waves. If delamination or crack increase in size, depth, or starts working, Master shall immediately cease sailing operations and O/O shall notify the Cognizant CG Marine Inspector per 46 CFR 176.840.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 14 July 2016
Resolution: 3rd party survey report provided, reviewed, with permanent repairs made on the main mast verified.
Sail Rigging › Mast Step › Mast Partners
Issued 22 June 2016 Resolved
Make repairs to fix crack & delamination in the Mainmast per 46 CFR 176.840. Permanent repairs shall be completed on or before 1 November 2016
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 14 July 2016
Resolution: Verified & Cleared
Operations/Management › Pollution › Control of Garbage
Issued 22 June 2016 Resolved
A written Waste Management Plan was not onboard. Draft or post a waste management plan per 33 CFR 151.57.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 24 June 2016
Resolution: Received an e-mail with a statement and photo reflecting a waste management placard (sticker) was obtained posted on the schooner.
Sail Rigging › Mast Step › Compression Post
Issued 22 June 2016 Resolved
Delamination observed in vessels foremast. Owner, operator & Masters shall monitor and notify the Cognizant OCMI if conditions change. If conditions remain the same, permanent repairs to correct the foremast delamination shall be completed when the mast is un-stepped during vessels next winter layup and prior to the next operating season, and no later than 15 May 2017
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 July 2016
Engineering › Fuel Oil Service System › Hose
Issued 22 June 2016 Resolved
Observed one non-approved fuel oil hose, between the diesel fuel oil filter to the fuel oil pump (suction side). Fitting barbed & supplied by engine manufacture, regardless hose required to be removed and fitted with a J1942 or A1, A2, B1, or B2 fuel hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 15 August 2016
Resolution: Informed & confirmed non-approved hose removed & new USCG approved hose installed. Cleared the requirement.
Sail Rigging › Mast Step › Mast Partners
Issued 30 May 2016 Resolved
IAW 46 CFR 176.840, pending permanent repairs to both masts, the vessels limited to the waters of Green Bay, not more than three miles from shore between Sturgeon Bay and Ellison Bay, WI, Mainsail will hoisted or restricted to ¾ sail. In winds greater than 25 kts, only the Gib and Stay Sails will be hoisted.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 19 July 2016
Resolution: Discussed 3rd party survey report & repairs with office supervisor [name withheld] to crack noted in main mast completed, concur with 3rd party surveyors report, required cleared.
Communications › Radio Communications › EPIRB
Issued 14 June 2012 Resolved
Install FCC Type Accepted Category 1 406 MHz EPIRB to automatically float free and activate prior to carrying passengers beyond 1 mile from land. 46 CFR 180.205 (e)(3). Type I EPIRB ordered & expected to arrive 27July2012.
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 1 August 2012
Resolution: Category 1 EPIRB installed, all dates current, and tested sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 June 2012 Resolved
Provide ring buoy light a lanyard with detachable clip. 46 CFR 180.70 (d)
Due 15 June 2012
Resolved 15 June 2012
Resolution: Ring buoy light attached to ring buoy via lanyard with detachable clip.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 14 June 2012 Resolved
Install type II retroreflective material on the ring buoy. 46 CFR 185.604(i)
Due 15 June 2012
Resolved 15 June 2012
Resolution: Retroreflective tape installed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 7 October 2011 Resolved
Provide required number of CG approved type I PFDs, current count is 17 adult and 3 child. 46 CFR 180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2012
Resolution: Required amount of PFDs onboard.
Engineering › Bilge Water Management System › Pump
Issued 7 October 2011 Resolved
Provide additional bilge pump (fixed hand pump onboard & portable hand pump missing). (old T) 46 CFR 182.25
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Resolution: Both bilge pumps onboard & operational.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 October 2011 Resolved
Provide operable visual & audible bilge high level alarm. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2012
Resolution: Bilge high level visual & audible alarm operational.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 7 October 2011 Resolved
Bring drug testing policy/program into compliance, see audit sheet dated 07Oct2011. 46 CFR 16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Resolution: DAPI program sat.
Personnel › Training › Watchkeeping
Issued 7 October 2011 Resolved
Obtain FCC radio operator permit. 47 CFR 13
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 7 October 2011 Resolved
Obtain FCC safety certificate. 47 CFR 13
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Resolution: FCC safety certificate issued 10Jun2012.
Lifesaving › Hand Flares › Quantity
Issued 7 October 2011 Resolved
Provide required number of approved distress signals (12 total). 46 CFR 180.68
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Resolution: 12 CG approved flares onboard.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 October 2011 Resolved
Post emergency broadcast placard. 46 CFR 184.506 & 184.510
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Resolution: Emergency broadcast placard posted.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 October 2011 Resolved
Post emergency instruction list. 46 CFR 185.510 & 185.512
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Resolution: Emergency instruction list posted.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 7 October 2011 Resolved
Properly mark hull with name and hailing port. 46 CFR 67.120-123
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Resolution: Hull marked with correct name & hailing port.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 7 October 2011 Resolved
Provide acceptable site glass or gauge for fuel tank. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 October 2011 Resolved
Remove and replace all non J1942 approved hoses for fuel tank. 46 CFR 182.720(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2012
Communications › Alarms/Indicators › Fire Alarm
Issued 7 October 2011 Resolved
Renew or remove inoperable fire alarm system. 46 CFR 181.120
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Resolution: Inoperable fire alarm system removed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 July 2011 Resolved
Stow child PFDs separately from adult PFDs. 46 CFR 180.78
Action required: 705 - Other - as specified
Resolved 14 June 2012
Resolution: Child PFDs stowed separately from adult PFDs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 July 2011 Resolved
Wiring throughout vessel is fastened to overhaead with plastic. Replace plastic fasteners/holds with metal prior to the carriage of passengers.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 7 October 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 July 2011 Resolved
Dead/improperly terminated wires throughout vessel. Remove wiring no longer in use.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 7 October 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 July 2011 Resolved
Conduct new-to-zone inspection prior to operating/carrying passangers outside of Sector Boston's AOR.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 7 October 2011
Resolution: New to zone exam conducted.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 13 July 2011 Resolved
Vessel is missing 2 Adult PFDs. Vessel is limited to 28 total persons onboard until 2 PFDs are provided.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 7 October 2011
Construction/Loadline › Structures › Superstructure
Issued 13 July 2011 Resolved
Swage eye on starboard bowsprit whisker stay is cracked. Renew prior to the carriage of passengers.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 7 October 2011
Resolution: Whisker stay replaced with chains.
Construction/Loadline › Structures › Superstructure
Issued 13 July 2011 Resolved
Wire rope on port bowsprit whisker stay is missing strand section (approx 4") near mid point of stay. Renew prior to carriage of passengers.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 7 October 2011
Resolution: Whisker stay replaced with chain.
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 June 2008 Resolved
Bilge alarm in engine compartment inoperable. Master will notify Coast Guard when alarm fixed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 4 June 2008 Resolved
Overboard discharge valve on MSDS needs to be locked out.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2008
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 4 June 2008 Resolved
Excess oil in engine room bilge. Master will remove excess oil from bilge and notify the Coast Guard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 June 2008 Resolved
11 of the adult TYPE I PFD's torn and not usable. Master will replace destroyed PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2008
Engineering › Bilge Water Management System › Hose
Issued 10 July 2006 Resolved
Replace the discharge hose on the installed hand pump bilge system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2006
Resolved 20 July 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 July 2006 Resolved
Replace the wasted line around the life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2006
Resolved 20 July 2006
Resolution: Replaced entire ring buoy.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 August 2005 Resolved
Service all portable and fixed fire extinquishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2005
Resolved 17 August 2005
Resolution: All fire extinquishers inspected sat.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 17 August 2005 Resolved
Re-connect broken reach rod to shut-off valve for fuel shut-off.
Due 31 August 2005
Resolved 6 September 2005
Resolution: Fuel shut-off reconnected.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 17 August 2005 Resolved
Replace missing flame arrestor for racor filter.
Due 31 August 2005
Resolved 6 September 2005
Resolution: Flame screen replaced.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 August 2005 Resolved
Provide emrgency broadcast placard
Due 31 August 2005
Resolved 6 September 2005
Resolution: Placard installed.
Operations/Management › Passenger Operations › Safety Orientation
Issued 17 August 2005 Resolved
Provide life jacket donning placard.
Due 31 August 2005
Resolved 6 September 2005
Resolution: Placard installed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 August 2005 Resolved
Replace all worn retro tape on all lifejackets.
Due 31 August 2005
Resolved 6 September 2005
Resolution: Retro tape replaced.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 8 June 2004 Resolved
Obtain a Radio Telephony Certificate from the FCC.
Due 22 June 2004
Resolved 22 June 2004
Engineering › Bilge Water Management System › Interface Detector
Issued 8 June 2004 Resolved
Install high level bilge alarm.
Due 22 June 2004
Resolved 22 June 2004
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 8 June 2004 Resolved
Provide boarding ladder for man overboard drills.
Due 22 June 2004
Resolved 22 June 2004
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 8 June 2004 Resolved
Cover existing life line with netting.
Due 22 June 2004
Resolved 22 June 2004
Documentation › Logs/Records › Logbook (official)
Issued 8 June 2004 Resolved
Provide a log book for recording drills a passenger count.
Due 22 June 2004
Resolved 22 June 2004
Fire Fighting › Fire Bucket › Availability
Issued 8 June 2004 Resolved
Provide 2 1/2 gallon fire buckets with lanyard.
Due 22 June 2004
Resolved 22 June 2004
Operations/Management › Drug and Alcohol Testing
Issued 17 September 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2002
Documentation › Certificates/Documents
Issued 17 September 2002 Resolved
CERTIFICATE OF DOCUMENTION DID NOT HAVE A VALIDATION STICKER FOR YEAR 2002, PROVIDE AND AFFIX VALID STICKER TO BACK OF CERTIFICATE. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 30 September 2002
Resolution: Valid sticker provided
Lifesaving › Lifejacket/PFD (Type IV)
Issued 17 September 2002 Resolved
PROCURE REPLACEMENT RING BUOY, BUOY DAMAGED DUE TO AGE AND EXPOSURE. BUOY WAS CRACKED FADED AND LINE WAS WASTED. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2002
Navigation › Piloting/Steering
Issued 17 September 2002 Resolved
PROVIDE NAVIGATIONAL CHARTS FOR VESSELS OPERATING AREA. LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 30 September 2002
Documentation › Logs/Records
Issued 17 September 2002 Resolved
PROVIDE VESSEL LOG BOOKLET STATING DRILLS TIMES AND DATES ALONG WITH CREWMEMBERS. VESSEL HAD NO OFFICIAL BRIDGE LOG OR ENTERIES. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 30 September 2002
Resolution: log book provided along with proper enteries
Lifesaving › Lifejacket/PFD (General)
Issued 17 September 2002 Resolved
PROVIDE PFD DONNING INSTRUCTION PLACARD FOR PASSENGERS
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2002
Resolution: placard provided
Engineering › Fuel Oil Storage/Transfer System
Issued 17 September 2002 Resolved
PROVIDE FLAME SHIELD BOWL FOR GALLEY STOVE FUEL FILTER. LEGACY COMPONENT DESC: Filter/Strainer
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2002
Engineering › Bilge Water Management System
Issued 17 September 2002 Resolved
REPLACE OR REPAIR BILGE PUMP FLOAT SWITCH, SWITCH WAS INOPERABLE. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2002
Engineering › Fuel Oil Service System
Issued 17 September 2002 Resolved
RESTENCIL FUEL CUT-OFF PLACARD. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 30 September 2002
Resolution: overboard discharge valve wire tie closed inport.
Unknown
Issued 10 July 2001 Resolved
Provide retro tape on life buoy's
Condition: Unknown
Due 23 July 2001
Resolved 24 July 2001
Unknown
Issued 10 July 2001 Resolved
Provide additional fire bucket.
Condition: Unknown
Due 23 July 2001
Resolved 24 July 2001
System not recorded
Issued 10 July 2001 Resolved
Install engine compartment heat detection system to the satisfaction of theattending marine inspector.
Condition: Unknown
Due 12 August 2001
Resolved 28 October 2002
Unknown
Issued 10 July 2001 Resolved
Install metal flame bowl under fuel filter.
Condition: Unknown
Due 23 July 2001
Resolved 24 July 2001
Unknown
Issued 10 July 2001 Resolved
Prove enrollment in drug testing program.
Condition: Unknown
Due 23 July 2001
Resolved 24 July 2001
Unknown
Issued 10 July 2001 Resolved
Update charts
Condition: Unknown
Due 23 July 2001
Resolved 24 July 2001
Unknown
Issued 10 July 2001 Resolved
Mark emergency escape exit
Condition: Unknown
Due 23 July 2001
Resolved 24 July 2001
Unknown
Issued 10 July 2001 Resolved
label life jackets
Condition: Unknown
Due 23 July 2001
Resolved 24 July 2001
Construction/Loadline
Issued 31 October 1995 Resolved
SUBMIT WRITTEN PROPOSAL FOR PULLING A REPRESENTIVE SAMPLE OF FASTENERS TO BE MADE AVAILABLE FOR INSPECTION BY ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Electrical
Issued 28 November 1990 Resolved
PROVIDE ADEQUATE EMERGENCY LIGHTING THAT OPERATE AUTOMATICALLY UPON LOSS OFPRIMARY LIGHTING SYSTEM IN LOUNGE AREAS BELOW THE MAIN DECK IAW 46 CFR 184.30-5.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Unknown
Issued 15 March 1990 Resolved
PREPARE AND POST EMERGENCY CHECK OFF LIST IN ACCORDANCE WITH 46 CFR 185.25
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Construction/Loadline
Issued 15 March 1990 Resolved
MAKE VESSEL AVAILABLE FOR UNDERWAY OPERATIONAL TEST FOR EXAMINATION OF HULLAND RIGGING.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Accommodation/Occupational Safety
Issued 27 March 1989 Resolved
PROVIDE VESSEL'S INSTALLED TOILET FIXTURE WITH APPROVED MARINE SANITATION DEVICE IN ACCORDANCE WITH 33 CFR 159 PRIOR TO 15 APRIL 1989.
Condition: Unknown
Due 27 March 1989
Resolved 27 March 1989

Casualty record · 1

2 October 2005Routine · role: Involved in a Marine Casualty · activity 2507630
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

APPLEDORE III (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.