Records from 1985 to 2026. Most recent: inspection, 2 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 53
2 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8340256
22 May 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8141420
18 April 2025
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8113793
24 April 2024
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7900951
17 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7690332
27 April 2023
In-Service Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7676575
10 January 2022
Plan Review "T" Boat · Simplified Stability Test · Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7378150
6 December 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7367688
6 April 2021
Deficiency Check · COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7168899
20 May 2020
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6956370
17 April 2019
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6663363
2 November 2018
Administrative Inspection · Hull Examination
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6567865
18 April 2018
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6393105
10 April 2017
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6117354
22 March 2016
Deficiency Check · COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5838127
22 October 2010
DAPI Audit
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3879188
10 April 2009
Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3447882
4 November 2008
Hull Examination
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3049409
15 April 2008
Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3184395
18 April 2007
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3033539
17 April 2007
Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2909581
18 April 2006
COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2592604
6 June 2005
Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2381140
10 May 2004
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2065967
5 November 2003
Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1942822
5 May 2003
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1788994
20 May 2002
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1617145
30 April 2001
COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1453896
16 May 2000
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1373200
17 May 1999
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1404761
11 December 1998
Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1454615
5 May 1998
COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1460188
29 May 1997
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 117127
2 May 1997
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1457446
6 May 1996
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1416297
24 May 1995
Deficiency Check
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 870802
4 May 1995
Deficiency Check · COI Inspection · Inclining Experiment
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1374275
15 September 1994
Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1382834
20 May 1993
COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1354338
20 May 1992
Administrative
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 949538
19 May 1992
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 944747
21 May 1991
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 921856
1 June 1990
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1232679
15 May 1990
COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1242586
16 April 1990
Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 923974
31 July 1989
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1198571
4 May 1989
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1032761
13 June 1988
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1205212
5 May 1988
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1349402
7 May 1987
COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1326729
22 May 1986
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 997938
24 May 1985
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 983973
22 April 1985
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 979228
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2025
Resolved
Flexible nonmetallic hose may be used in non-vital water and pneumatic systems, subject to the limitations of paragraph (d)(1) through (d)(4) of this section.
Vessel fresh water system hoses penetrate bulkheads and do not have metallic fittings and valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2025
Resolved 22 May 2025
Resolution: Received photos of metallic fittings and valves installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2023
Resolved
Provide means to stow child size PFD's separate from Adult.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 15 May 2023
Resolution: Photo provided that child pfd's are segregated.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2023
Resolved
Install Covers on 12 vdc panel lights in the Pilothouse.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 10 May 2023
Resolution: Item was corrected, owner provided photo
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 9 May 2023
Resolved
Provide onboard lighted magnetic compass.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2023
Resolved 11 May 2023
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 9 May 2023
Resolved
Provide PA speaker on bow and stern of vessel.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 15 May 2023
Resolution: Speakers installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 May 2023
Resolved
Provide pressure gauge at a fire pump.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 11 May 2023
Resolution: photo of gauge provided.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 9 May 2023
Resolved
Provide suitable ladder and plateform to recover a Man Overboard.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2023
Resolved 11 May 2023
Resolution: Ladder provided for recovery.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 May 2023
Resolved
Provide capture chains on forward and aft hatches on the weather deck.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 10 May 2023
Resolution: Photos provided that chains where installed. Cleared 835
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 May 2023
Resolved
Properly mount, with approved brackets fire extinguishers throughout the vessel.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2023
Resolved 11 May 2023
Resolution: Proper brackets installed, photo provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 May 2023
Resolved
Seal all penetrations in the watertight bulkheads.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 15 May 2023
Resolution: photos provided of penetrations being sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2023
Resolved
Properly support 1 1/2" PVC pipe on the port side of the fresh water tank space.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 15 May 2023
Resolution: Supports provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 May 2023
Resolved
Install lids on genetator starting batteries.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 11 May 2023
Resolution: Covers installed and photo provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 May 2023
Resolved
Replace flame screen on the port diesel fuel tank vent.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 11 May 2023
Resolution: Flame screen renewed and photo provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 December 2021
Resolved
Prior to carrying passengers complete new to zone inspection and drill for change in service.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 May 2022
Resolved 9 May 2023
Resolution: Complete COI done this date.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 6 April 2021
Resolved
Marine employer must have sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel did not have any alcohol testing swabs. Obtain sufficient amount of alcohol testing devices.
CITE: 46 CFR 4.06-15(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 23 April 2021
Resolution: Obtained new testing devices
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 April 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts, Coast Pilots [name withheld] navigation publications and charts were from 2018. Obtain up-to-date publications and charts for intended voyage area.
CITE: 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 23 April 2021
Resolution: Obtained up-to-date charts and publications for area of operation
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 April 2021
Resolved
All emergency exits used for means of escape must be marked on both sides with "EMERGENCY EXIT, KEEP CLEAR". Forward emergency escape from upper deck not marked. Mark emergency escape.
CITE: 46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 23 April 2021
Resolution: Marked means of escape
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 April 2021
Resolved
Vessel must carry a first aid kit. In first aid kit 03 of the medicine bottles were expired. Remove expired items and replace.
CITE: 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 23 April 2021
Resolution: Removed and replaced medicine.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 April 2021
Resolved
Found old PVC piping in engine compartment that was not capped off. Piping to be capped off or removed from space.
CITE: 46 CFR 182.700
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 8 April 2021
Resolution: Piping capped.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 April 2021
Resolved
In stern void, hydraulic piping was being held up by zip ties. Remove zip ties and replace with suitable supports.
CITE: 46 CFR 182.700
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 8 April 2021
Resolution: Zip ties removed and new supports installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 April 2021
Resolved
Hatch exposed to the weather must be watertight. Forward void space's hatch gasket coming off the cover. Repair gasket.
CITE: 46 CFR 179.360(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 8 April 2021
Resolution: Gasket repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 April 2021
Resolved
Each Life jacket must be marked in clearly legible block capital letters with the vessel's name. Multiple life jackets markings were worn and not legible. Re-mark life jackets.
CITE: 46 CFR 185.604(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 18 June 2021
Resolution: Life jackets were marked.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 6 April 2021
Resolved
Vessel must comply with applicable requirements for any radio. Inspected Small passenger vessels that transport 7-12 passengers for hire must be equipped with a VHF-DSC. Vessel does not have a VHF-DSC installed. Install VHF-DSC.
CITE: 46 CFR 185.502
Policy Ltr 15-06 CH-2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 23 April 2021
Resolution: Installed DSC and MMSI number for VHF.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 April 2021
Resolved
Vessel unable to provide any log books from the previous 2 seasons and to show completion of drills per requirement. Vessel conducted fire, abandon ship, and man overboard drills on 6 APR 2021 during inspection and started new log book.
CITE: 46 CFR 185.520(f)
46 CFR 185.524(d)
Action required: 10 - Deficiency Rectified
Resolved 6 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2019
Resolved
Replace/renew 01 defective lifejacket, 07 need retro tape, 06 need repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 23 April 2019
Resolution: Lifejacket(s) were replaced, repaired, and retro renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2019
Resolved
Repair life ring.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2019
Resolved 23 April 2019
Resolution: Life ring was repaired.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 March 2016
Resolved
Retro Reflective material needs to be affixed to the ring bouy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 15 April 2016
Resolution: Installation satisfactory.
Engineering › Fuel Oil Service System › Piping
Issued 22 March 2016
Resolved
Fuel oil return line is leaking in the engine room and the fuel tank space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 15 April 2016
Resolution: Examined two new fuel line unions. No leakage noted. All sat.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 22 March 2016
Resolved
Storage bins for both Adult quantity (19) and Child (09) requires re-marking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 15 April 2016
Resolution: Forward under steat stowage areas restenciled with proper complement.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 April 2008
Resolved
Remove all open ended wires behind steering console and 12 volt pannel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2008
Resolution: Open ended wires have been removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 April 2008
Resolved
Replace extention cord with approved wiring for the vessels horn air flask.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2008
Resolution: Approved electrical wiring in place.
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 17 April 2007
Resolved
Replace port M/E aft outboard mount.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2007
Resolution: Mount has been replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 17 April 2007
Resolved
Install a machinery guard on STBD M/E pulley.
Due 17 May 2007
Resolved 30 April 2007
Resolution: Guard installed
Engineering › Steering Gear System › Ram
Issued 18 April 2006
Resolved
Repair/replace stbd. side hydro steering ram.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Inspected satisfactory.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 18 April 2006
Resolved
Provide proof of first aid/cpr training.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Inspected satisfactory.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 18 April 2006
Resolved
Make permanent repairs to MSD tank failed weld.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Inspected satisfactory.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 18 April 2006
Resolved
Clean deck on port side aft. of diesel tank void.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 27 April 2006
Resolution: Inspected satisfactory.
Operations/Management › Passenger Operations › Safety Orientation
Issued 18 April 2006
Resolved
Permantly mount rule pump and wiring in lazeret.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 27 April 2006
Resolution: Inspected satisfactory.
Stability › Watertight Integrity › General
Issued 18 April 2006
Resolved
Repair watertight bulkheads where rule pump wiring paases.
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 27 April 2006
Resolution: Inspected satisfactory.
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 10 May 2004
Resolved
Replace Retroreflective material on lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Unknown
Due 10 July 2004
Resolved 9 July 2004
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 May 2004
Resolved
Provide Life preserver donning placard in vicinity of life preservers.
Condition: Improper/Lack of Maintenance
Due 10 July 2004
Resolved 9 July 2004
Fire Fighting › Fire Hoses › Condition
Issued 10 May 2004
Resolved
Replace holed fire hose. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 10 July 2004
Resolved 9 July 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 10 May 2004
Resolved
Remove all extension cords used for power supply from vessel. LEGACY COMPONENT DESC: Power Requirement
Condition: Improper Installation
Due 30 June 2004
Resolved 9 July 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 10 May 2004
Resolved
Removed unused exposed bilge switch wire in galley space. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 10 July 2004
Resolved 9 July 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 10 May 2004
Resolved
Properly cover or remove exposed radio wires on bridge. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 10 July 2004
Resolved 9 July 2004
Lifesaving › Lifejacket/PFD (General)
Issued 5 May 2003
Resolved
Renew retro-reflective tape on lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Due 19 May 2003
Resolved 23 June 2003
Fire Fighting › Fire Hoses
Issued 5 May 2003
Resolved
Renew fire hose. LEGACY COMPONENT DESC: Condition
Due 19 May 2003
Resolved 23 June 2003
Electrical › Electric Supply System (service)
Issued 5 May 2003
Resolved
Properly dead end wires in liquor storage area. LEGACY COMPONENT DESC: Cable
Due 19 May 2003
Resolved 23 June 2003
Electrical › Electrical Distribution System (service)
Issued 5 May 2003
Resolved
Provide cover for grounding blocks located in engineroom below the deck entrance. LEGACY COMPONENT DESC: Grounding Conductor
Due 19 May 2003
Resolved 23 June 2003
Electrical › Electrical Distribution System (service)
Issued 5 May 2003
Resolved
Provide covers for exposed speaker backs. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Due 19 May 2003
Resolved 23 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 20 May 2002
Resolved
Remove bilge pump starting switch and wiring from small liquor storage area. LEGACY COMPONENT DESC: Spark Producing Device
Due 3 June 2002
Resolved 20 August 2002
Lifesaving › Lifebuoys
Issued 20 May 2002
Resolved
Renew aft ring buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 3 June 2002
Resolved 20 August 2002
Lifesaving
Issued 4 May 1995
Resolved
Provide labeling of all PFD storage areas.
Condition: Unknown
Due 18 May 1995
Resolved 9 May 1995
Navigation
Issued 4 May 1995
Resolved
Prove proper operation of horn.
Condition: Unknown
Due 18 May 1995
Resolved 9 May 1995
Unknown
Issued 4 May 1995
Resolved
Prove compliance with drug testing regulations.
Condition: Unknown
Due 18 May 1995
Resolved 9 May 1995
Lifesaving
Issued 4 May 1995
Resolved
Provide 3rd ring buoy for aft rail of upper passenger deck.
Condition: Unknown
Due 18 May 1995
Resolved 9 May 1995
Fire Fighting
Issued 4 May 1995
Resolved
Provide guard for fire pump pulley.
Condition: Unknown
Due 18 May 1995
Resolved 9 May 1995
Lifesaving
Issued 4 May 1995
Resolved
Complete drills in the presence of USCG Marine Inspector.
Condition: Unknown
Due 15 May 1995
Resolved 9 May 1995
Accommodation/Occupational Safety
Issued 4 May 1995
Resolved
Prove proper operation of toilets.
Condition: Unknown
Due 18 May 1995
Resolved 9 May 1995
Documentation
Issued 4 May 1995
Resolved
Provide documentation with proper owner._x001C_
Condition: Unknown
Due 18 May 1995
Resolved 9 May 1995
Lifesaving
Issued 4 May 1995
Resolved
Provide and mount Primary Lifesaving equipment.
Condition: Unknown
Due 15 May 1995
Resolved 9 May 1995
Engineering
Issued 4 May 1995
Resolved
Provide label for Emergency Fuel Oil Shutoff.
Condition: Unknown
Due 18 May 1995
Resolved 9 May 1995
Documentation
Issued 4 May 1995
Resolved
Provide copy of current Great Lakes Agreement Radiotelegraph Certificate._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Fire Fighting
Issued 4 May 1995
Resolved
Relocate two BII fire extinguishers from engineroom to both passenger decks.
Condition: Unknown
Due 18 May 1995
Resolved 9 May 1995
Electrical
Issued 20 May 1993
Resolved
ELECTRICAL LIGHTS MISSING GLOBES.
Condition: Unknown
Due 20 May 1993
Resolved 20 May 1993
Engineering
Issued 15 May 1990
Resolved
PROVIDE GUARD OVER BELT AND PULLEY TO BILGE PUMP ON PORT ENGINE.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
PROVIDE GLOBE FOR LIGHT IN WOMEN'S RESTROOM.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Navigation
Issued 4 May 1989
Resolved
REPAIR OR PROVIDE PROPERLY OPERATING DEPTH FINDER.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Fire Fighting
Issued 4 May 1989
Resolved
PROVIDE A HAND OPERATED FIRE AND BILGE PUMP.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Electrical
Issued 4 May 1989
Resolved
PROVIDE LIGHT GLOBES FOR LIGHTS IN LADIES HEAD AND ON FANTAIL.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Accommodation/Occupational Safety
Issued 4 May 1989
Resolved
PROVIDE CAP FOR FRESH WATER TANK.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Navigation
Issued 5 May 1988
Resolved
EMERGENCY CHECKOFF LIST MISSING. LIST RE-WRITTEN AND POSTED BY END OF INSPECTION.
Condition: Unknown
Due 5 May 1988
Resolved 5 May 1988
Electrical
Issued 5 May 1988
Resolved
ELECTRICAL FUSE BOX ON BRIDGE HAD EMERGENCY FLARES AND PAPER BOOKS STORED IN IT. DEFICIENCY CORRECTED BY END OF INSPECTION.
Condition: Unknown
Due 5 May 1988
Resolved 5 May 1988
Lifesaving
Issued 5 May 1988
Resolved
PROVIDE 4 ADDITIONAL PFD'S AND CARRY NO MORE THAN 314 PASSENGERS UNTIL SUCH ADDITIONAL PFD'S ARE ONBOARD.
Condition: Unknown
Due 5 May 1988
Resolved 5 May 1988