EBB TIDE PRINCESS

EBB TIDE PRINCESS is a 1984 passenger vessel (inspected). The Coast Guard has recorded 77 inspections since 1985, most recently in May 2025, along with 126 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2012.

Records from 1985 to 2025. Most recent: inspection, 29 May 2025.

Built
1984
Last inspected
29 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAN6419
231177
Flag
UNITED STATES
367052470, 368420990
Maury page id
psix-231177

Inspections, by type

…with no type recorded4
Years with a record 37 calendar years (1985–2025)
The 77 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)66.6 ft × 20.8 ft × 5.7 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1984
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTAUK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9385MMSI 367052470 · active · compulsorily equipped · granted 29 April 2026, expires 29 April 2036
WDQ3918MMSI 368420990 · active · compulsorily equipped · granted 28 May 2025, expires 28 May 2035 · licensed under a name not among this hull’s recorded names (not shown)
WAN6419MMSI 367052470 · expired · compulsorily equipped · granted 17 June 2015, cancelled 23 August 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 77

29 May 2025 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8145365
9 January 2025 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8060500
4 November 2024 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8025622
5 July 2024 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7949996
7 November 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7814354
23 May 2023 Internal Structural Exam · Examination of Repairs · Drydock Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7672234
25 October 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7575307
1 September 2022 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7528298
27 April 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7439299
8 November 2021 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7339048
19 October 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7322111
25 May 2021 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7178487
20 October 2020 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7063725
22 October 2019 COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6829815
10 September 2019 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6808195
22 May 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6669172
16 October 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6534063
24 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6521669
12 October 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6276050
6 June 2017 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6168621
16 May 2017 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6121240
2 January 2017 Type not recorded
No type recorded · Station Point Judith · USCG Northeast District (CGD-NE) · Activity 6064750
18 October 2016 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6024949
29 September 2015 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5731393
21 October 2014 Internal Structural Exam · DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4966808
2 December 2011 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4200451
22 September 2011 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4151736
6 October 2010 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3864636
28 October 2008 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3344369
16 January 2008 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3131645
4 October 2007 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3072994
1 May 2007 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2919136
27 October 2005 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2516935
26 April 2005 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2342386
27 October 2004 COI Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2229349
30 October 2003 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1935412
29 April 2003 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1782583
30 October 2002 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1696697
2 November 2001 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1076388
24 October 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1426681
26 April 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1451769
19 March 2001 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1061414
24 October 2000 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1393592
27 October 1999 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1450355
20 April 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1434852
19 April 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 791590
28 October 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 808839
27 July 1998 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 795021
24 October 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1114504
17 July 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1117113
24 October 1996 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1161055
28 November 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 883052
25 October 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 884245
14 February 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 841359
18 November 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181452
26 October 1994 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 864321
18 October 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1400085
16 November 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1141510
19 October 1993 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1461542
23 November 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1138469
19 October 1992 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1246779
6 April 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 961315
31 October 1991 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 941995
22 October 1991 Deficiency Check · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 941584
26 October 1990 Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 926006
23 July 1990 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 916576
18 October 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1322211
13 October 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1322866
18 October 1988 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199160
16 October 1987 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1323431
19 August 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030997
29 May 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029530
27 March 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329414
30 May 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993116
27 December 1985 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993573
1 November 1985 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1302853
24 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979892

Deficiency record · 126

03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 29 May 2025 Resolved
A penetration in a watertight bulkhead must be … made watertight. The gate valve in bilge piping for fwd compartment is seized. Replace seized gate valve. CITE: 46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025 Resolved
Observed unsafe practices, fire hazards, and other hazardous situations must be corrected …. Excessive build-up of grease/oil was observed on both generators. De-grease both generator sets’ windings. CITE: 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025 Resolved
All cable and wire must … be installed with metal supports spaced not more than 24” apart. Install metal wire straps every 24". CITE: 46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 29 May 2025 No resolution recorded
Ea watertight bulkhead must be … capable of remaining watertight …. Rotted wood was identified in the transverse floor beam IWO bilge piping thru fwd blkhd in bunk room serving fwd compartment. Made temp repair 02July2025. Make permanent repair at next drydock. CITE: 46 CFR 179.320(a)
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 29 May 2025 Resolved
The number of penetrations in a watertight bulkhead must be minimized. There are unsealed blkhd penetrations in tank room, aft stbd side @ deck. Seal all blkhd penetrations in tank room. CITE: 46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 29 May 2025 Resolved
Ea inlet/dischg pipe that penetrates the hull below 6” above the waterline must have means to prevent water from entering the vessel. The overboard gate valve in tank room, port side just above the chine is seized. Replace the seized gate valve. CITE: 46 CFR 179.350(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025 Resolved
Wires are to be installed … in such a manner as to avoid chafing and other damage. The wire for the high-water alarm float in fwd bunk room interferes w/ the float. Secure loose wiring. CITE: 46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 May 2025 Resolved
Lifesaving equipment must be maintained in serviceable condition. One life float was damaged thru the skin along its length. Properly repair damaged life float. CITE: 46 CFR 180.25(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 May 2025 Resolved
Lifesaving equipment must be maintained in serviceable condition. One life float was severely faded. Properly repaint faded life float w/ hi viz paint. CITE: 46 CFR 180.25(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025 Resolved
Electrical equipment exposed to the weather must be watertight. The port & stbd nav light housings are cracked. Replace both nav light housings w/ appropriate weather-tight UL approved housings. CITE: 46 CFR 183.210(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 6 October 2025
Resolution: Verified new installation of nav lights.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 May 2025 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q. The batteries are expired in the waterlights. Replace all expired waterlight batteries. CITE: 46 CFR 180.70(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verfied in person
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangements rescue boats
Issued 29 May 2025 Resolved
Lifesaving equipment, incl. ring buoys, PFDs, L/F paddles, L/Fs, etc., are to be marked w/ the vessel’s name. The vsl’s name is missing from a number of L/S items. Complete properly mark all life-saving equip w/ vsl’s name. CITE: 46 CFR Part 180
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 May 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. The aspirin is expired. Replace expired aspirin in 1st aid kit. CITE: 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2025 Resolved
The vsl name must be marked on the port & starboard bow & the stern of the vessel. The hailing port must be marked on the stern. The old name is currently on the vessel. Place vsl name on hull. CITE: 46 CFR 67.123 C 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 November 2024 Resolved
Inspection of each portable fire extinguisher, semi-portable fire extinguisher, and fixed gas fire extinguishing system to be completed by a certified fire extinguisher servicing agency annually. Annual inspection overdue.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2024
Resolution: 3rd party fire servicing completed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 November 2024 Resolved
A vessel on an oceans, coastwise, limited coastwise, route must carry Six hand red flare distress signals approved in accordance with § 160.021. Flares expired.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2024
Resolution: Expired flares repalced with new
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 4 November 2024 Resolved
Lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter. Lifelines on 01 lifefloat was past its service life.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2024
Resolution: Lifeline replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2024 Resolved
The vessel shall be ready for inspections of fuel piping systems. Leaks found at tank valves to be corrected.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2024
Resolution: Valve packing tightened and tested for leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2024 Resolved
Engine exhaust pipe must be double clamped where practicable. Clamps to be tightened or replaced to prevent leaks
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2024
Resolution: Clamps repaired and system op tested.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 November 2024 Resolved
The EPIRB test required shall be logged or otherwise documented, as applicable. No tests recorded.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 December 2024
Resolution: Epirb tests conducted & logged
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 November 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 December 2024
Resolution: New charts purchased
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 7 November 2023 Resolved
The color of the buoyant apparatus must be primarily vivid reddish orange as defined by sections 13 and 14 of FED–STD–595C. Lifefloat experienced excessive sun damage to outer shell causing for loss of shell, loss of color and degradation of the buoyancy foam.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Replaced buoyant apparatus
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 7 November 2023 Resolved
The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Lanyards have excessive sun damage causing the failure of the line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2023
Resolved 9 November 2023
Resolution: Lines replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 November 2023 Resolved
Each lifeline on a ring life buoy must Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light.Lanyards have excessive sun damage causing the failure of the line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Lines replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 November 2023 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Bilge foot valves seized and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2023
Resolution: Bilge foot valves all opened, inspected cleaned and returned to operation
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 November 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessel storing paint and hazardous material outside of an authorized paint locker.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Removed flammable paints and materials off vessel
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 November 2023 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute and 60 Pounds per square inch. Installed pump only putting out 30 PSI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2023
Resolved 5 July 2024
Resolution: Pump replaced and tested with greater than 60 PSI at the pump using one hose.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 November 2023 Resolved
Vital systems shall be acceptable to the cognizant OCMI, nonferrous metallic piping with a melting temperature above 927 °C (1,700 °F) may be used in vital systems that are deemed to be galvanically compatible. Installed PVC and Flex hose do not meet the melting temperature requirement for vital systems
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2023
Resolved 5 July 2024
Resolution: PVC piping replaced with copper conducted satisfactory test of repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2023 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. STBD Deck rail stanchion loose.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2023
Resolved 8 November 2023
Resolution: Rail stanchions resecured
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 7 November 2023 Resolved
At each inspection for certification and at every other vessel inspection all and all required guards and protective devices must be in satisfactory condition. Port MDE belt drive pump pulley is accessible to crew in engine room main passageway
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 9 November 2023
Resolution: Guard installed at pump pulley
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 May 2023 Resolved
An internal structural exam consists of a complete examinations of a vessel's main strength members including the major framing and planking. Found frame number two aft to fwd on port side of fwd peak cracked on upper section. Found frame number four aft to fwd on port side with some wood decay on upper area IWO deck beam.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 12 June 2023
Resolution: Frames #2, #3, and #4 aft-to-fwd port side repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2022 Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead and made watertight. Penetrations in the engine room and collision bulkhead are not watertight.
Action required: 10 - Deficiency Rectified
Due 25 October 2022
Resolved 25 October 2022
Resolution: Penetrations were made watertight.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 October 2022 Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station to indicate high water. The high water alarm in the engine room does not work. Make/log rounds of the engine room every 30 minutes while underway.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 7 November 2022
Resolution: Replaced the high water alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 September 2022 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead, and made watertight. Penetration in the fwd bulkhead, mid-center needs to be made watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2022
Resolved 11 September 2022
Resolution: Hole sealed up in bulkhead
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 27 April 2022 Resolved
Vessels that have overnight accommodations for passengers must submit plans to the cognizant OCMI by 28Mar2022 for the installation and use of a monitoring device to ensure the wakefulness of the watchmen. The monitoring device must ensure the wakefulness of the crew in the event that the watchman is unresponsive; Remain operable during the nighttime watch; and Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. Submit plans to the OCMI by 27May2022.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 13 July 2022
Resolution: Vessel opted to remove overnight passengers from COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2021 Resolved
Each ring life buoy must be marked with Type II retroreflective material as specified in IMO Resolution A.658(16). Ring life buoy retroreflective tape is worn and needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Applied new retroreflective tape to the ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2021 Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. 12 adult and 2 child lifejacket markings are illegible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Re-stenciled life jackets with vessel name.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 October 2021 Resolved
All escape hatches shall be marked on both sides "Emergency Exit, Keep Clear". Vessel escape hatch markings are faded and need to be redone.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Re-stenciled escape hatch.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 October 2021 Resolved
A vessel must have a first aid kit approved under 160.041 or equivalent contents stowed in a watertight container marked First Aid Kit. First aid kit has expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Obtained replacements for expired items in first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021 Resolved
Remote fuel shutoff valves shall be marked in 1-inch letters indicating the purpose of the valve and direction of operation. Fuel shut off valves do not indicate the purpose of each valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Fuel shut off valves have been marked to indicate purpose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 October 2021 Resolved
For alternating current generators, a means for measuring frequency shall be provided. Hertz frequency meter is not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Verified hertz frequency meter is now working.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 October 2021 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Wiring for the fan in the forepeak is not marine grade.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Wiring for the fan in the forepeak has been replaced with marine grade.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 October 2021 Resolved
Wiring joints and spices shall be mechanically secure and made in junction boxes. Enclose or remove dead end wires in the lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 8 November 2021
Resolution: Dead end wires have been placed in an enclosure.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 October 2021 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Freshwater pump is not hardwired and needs cable hangers in the lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 8 November 2021
Resolution: Freshwater pump has been hardwired and has an on/off switch.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 October 2021 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC licensed technician once every 5 years, after which a Communications Act Safety Radiotelephony Certificate will be issued. Vessel does not have a current radiotelephony certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 9 November 2021
Resolution: Obtained new FCC radio safety certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 October 2021 Resolved
Bridge-to-bridge radiotelephone station will be inspected on vessels subject to regular inspections pursuant to the requirements of Parts II and II of Title III of the Communications Act. Vessel does not have a valid bridge-to-bridge FCC certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 9 November 2021
Resolution: Obtained the FCC bridge to bridge certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 20 October 2020 Resolved
Provide evidence of weak link breaking strength for life floats. Identification tag missing on weak link.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 3 February 2021
Resolution: Purchased new weak link for life floats
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2020 Resolved
Electrical outlet not properly secured into bulkhead in tank/CO2 space creating electrical hazard. Properly insert electrical outlet into bulkhead.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 3 February 2021
Resolution: Electrical outlet properly mounted
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 October 2020 Resolved
Valve for fuel filters needs to have cap or plug to prevent fuel leakage. Provide proper cap/plug to satisfaction of CG marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 3 February 2021
Resolution: Plugs installed on fuel filters
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2019 Resolved
A fire hose must be attached at each fire hydrant. The port side fire hose was worn and leaking.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 22 October 2019
Resolution: Provided evidence that the fire hose was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 October 2019 Resolved
Each lifjacket must be marked in clearly legible block capital letters with the vessel's name. 16 life jackets were found with the vessel's name not clearly legible.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 22 October 2019
Resolution: Provided evidence that the 16 lifejackets were properly marked.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 September 2019 Resolved
Smoke detectors expired. Install proper UL217 smoke detectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 23 September 2019
Resolution: New UL217 smoke detectors installed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 September 2019 Resolved
Verify proper wiring of electrical outlets in galley. 46 CFR 183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 23 September 2019
Resolution: Polarity checked using tester. All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 September 2019 Resolved
Provide proper logs per regulations for primary lifesaving maintenance and watchmen rounds.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 7 October 2019
Resolution: Logs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 September 2019 Resolved
Repair/replace lifefloat as discussed. Max persons onboard reduced by 22 persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 23 September 2019
Resolution: New lifefloat installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 September 2019 Resolved
Replace battery for fire detection system. Battery over 10 years old.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Battery replaced.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 August 2018 Resolved
AIS is not correctly broadcasting the correct vessel name.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 14 September 2018
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 October 2017 Resolved
Provide updated Eldridge book.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 13 October 2017
Navigation › Piloting/Steering › Marine Charts
Issued 12 October 2017 Resolved
Provide updated charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 13 October 2017
Fire Fighting › Fire Pumps › Gland Sealing
Issued 12 October 2017 Resolved
Repair main fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 23 October 2017
Electrical › Lighting (service) › Conductor
Issued 18 May 2017 Resolved
Rewire lighting in tank compartment with approved boat/marine cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 6 June 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 18 October 2016 Resolved
Provide GPS information and enter MMSI number into VHF radio.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 29 November 2016
Documentation › Certificates/Documents › FCC SSL
Issued 18 October 2016 Resolved
Provide FCC station license.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 18 October 2016
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › Marine Charts
Issued 18 October 2016 Resolved
Provide updated charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 29 November 2016
Communications › Radio Communications › EPIRB
Issued 18 October 2016 Resolved
Epirb battery expired. Vessel restricted to no more than 3 miles from shore until new epirb battery has been obtained.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 18 October 2016
Resolution: Corrected via proof of purchase, registration, and installation photos.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 29 September 2015 Resolved
Provide new FCC station and safety radio license, current certs are expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2015
Resolved 24 October 2015
Resolution: Provided new FCC station and radio license.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 December 2011 Resolved
The vessels total persons allowed has been reduced to 111 persons. This requirement is effective until you come into compliance with the requirements of the new stability regulations.
Action required: 705 - Other - as specified
Due 2 December 2011
Resolved 17 October 2012
Resolution: Amended COI to reduce passenger count to 111 persons.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 16 January 2008 Resolved
DEMONSTRATE INSTALLED FIRE DETECTION SYSTEM HAS ELECTRICALLY SUPERVISED DETECTION CIRCUITS OR INSTALL A USCG APPROVED FIRE DETECTION SYSTEM BY 28MAY08.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 May 2008
Resolved 20 May 2008
Resolution: Modified existing fire detection system by installing a test circuit to detect system failure.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 4 October 2007 Resolved
Provide documentation on fire detection to demonstrate approval for system.
Condition: Unknown
Due 23 November 2007
Resolved 24 October 2007
Resolution: DOCUMENTATION PROVIDED. SYSTEM NEED PHYSICAL TEST BY CG INSPECTOR TO VERIFY IF DETECTION CIRCUIT IS ELECRICALLY SUPERVISED. NEW 835 ISSUED UNDER ADMIN CASE.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 4 October 2007 Resolved
Provide a 2 inch extension beyond the last orifices in the distribution lines.
Condition: Improper Installation
Due 26 November 2007
Resolved 24 October 2007
Lifesaving › Lifebuoys › Serviceable
Issued 4 October 2007 Resolved
Renew deteriorated life ring located on the aft bulkhead of the pilothouse
Condition: Damaged By Earlier Event
Due 24 October 2007
Resolved 20 October 2015
Resolution: Life ring renewed.
Fire Fighting › Fire Pumps › Pressure
Issued 4 October 2007 Resolved
Repair or replace pressure guage on fire pump
Due 25 October 2007
Resolved 25 October 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 4 October 2007 Resolved
Provide a PFD donning placard on the top deck in vicinity of PFD stowage.
Condition: Unknown
Due 25 October 2007
Resolved 25 October 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 October 2005 Resolved
Must complete drills (MOB/Fire) prior to carriage of pax.
Action required: 705 - Other - as specified
Due 27 October 2005
Resolved 2 November 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 October 2005 Resolved
Replace all retro reflective tape on all adult/child preservers prior to carriage of pax
Action required: 705 - Other - as specified
Due 27 October 2005
Resolved 2 November 2005
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 October 2005 Resolved
Provide "Emergency Exit, Keep Clear" sign/marking on engine room hatch.
Action required: 705 - Other - as specified
Due 10 November 2005
Resolved 2 November 2005
Lifesaving › Lifebuoys › Serviceable
Issued 27 October 2005 Resolved
Provide retro reflective tape for all (3) ring life buoys--both sides.
Action required: 705 - Other - as specified
Due 10 November 2005
Resolved 2 November 2005
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 October 2005 Resolved
Provide DAPI documentation showing enrollment of all crew members.
Action required: 705 - Other - as specified
Due 10 November 2005
Resolved 2 November 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 October 2005 Resolved
Replace expired items for first aid kit.
Action required: 705 - Other - as specified
Due 10 November 2005
Resolved 2 November 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 27 October 2005 Resolved
Provide FCC operator's permit for [name withheld] 25 Nov 05.
Action required: 705 - Other - as specified
Due 25 November 2005
Resolved 2 November 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 October 2005 Resolved
Provide Emergency Fuel Shutoff sign/markings in proper locations.
Action required: 705 - Other - as specified
Due 10 November 2005
Resolved 2 November 2005
Fire Fighting › Fire Main › Valves
Issued 27 October 2004 Resolved
Properly repair/replace the valve handle for the fire main in the machinery space forward port side in the overhead.
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 9 November 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 27 October 2004 Resolved
Provide servicing certificate for fixed CO2 system indicating proper hydrostatic testing (Mark on inboard cylinder is missing).
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 9 November 2004
Lifesaving › Lifefloat › Painter
Issued 27 October 2004 Resolved
Properly re-install the sea painter.
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 9 November 2004
Lifesaving › Lifebuoys › Serviceable
Issued 27 October 2004 Resolved
Provide reflective tape for the aft ring buoy.
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 9 November 2004
Communications › Radio Communications › EPIRB
Issued 27 October 2004 Resolved
Replace battery in EPIRB. Vessel is restricted to operating inside 3 mile territorial sea limit.
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 9 November 2004
Lifesaving › Hand Flares
Issued 30 October 2003 Resolved
Provide all flares. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2003
Resolved 30 October 2003
Resolution: Provided receipt for flares.
Operations/Management › Drills/Instruction
Issued 30 October 2003 Resolved
Complete MOB drills prior to departure for Florida. LEGACY COMPONENT DESC: Fire
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2003
Resolved 7 November 2003
Resolution: Conducted drills to the satisfaction of Marine Inspector
Communications › Radio Communications › EPIRB
Issued 30 October 2003 Resolved
Replace hydro on EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2003
Resolved 31 October 2003
Resolution: Provided receipt for hydro on EPIRB
Documentation › Safety Management System
Issued 30 October 2003 Resolved
Provide emergency broadcast placard LEGACY COMPONENT DESC: Emergency Drill/Exercise Programs
Action required: 705 - Other - as specified
Due 27 November 2003
Resolved 7 November 2003
Resolution: Provided ship-board made placard.
Lifesaving
Issued 30 October 2003 Resolved
Provided proper flares
Due 31 October 2003
Resolved 7 November 2003
Resolution: Provided proper flares
Documentation
Issued 30 October 2003 Resolved
Provided safety placard
Due 7 November 2003
Resolved 7 November 2003
Resolution: Provided safety placard
Communications
Issued 30 October 2003 Resolved
Vessel did not have comm. safety placard
Due 7 November 2003
Resolved 7 November 2003
Resolution: Provided safety placard
Operations/Management
Issued 30 October 2003 Resolved
Complete MOB drills to the satisfaction of Marine Inspector
Due 7 November 2003
Resolved 7 November 2003
Resolution: Completed MOB drills, all SAT
Operations/Management › Drills/Instruction
Issued 30 October 2002 Resolved
Vessel needs to conduct sat MOB drill with dummy while operating in he PROMS zone to the satisfaction of a Marine Inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 30 May 2003
Resolved 24 June 2003
System not recorded
Issued 24 October 2001 Resolved
Install engineroom ventilation shutdowns. (Vessel is using burlap bags until proper covers are made). _x001C_
Condition: Unknown
Due 8 December 2001
Resolved 4 September 2002
Unknown
Issued 24 October 2001 Resolved
Provide station bill, waste management plan, light list and updated chart.
Condition: Unknown
Due 24 October 2001
Resolved 24 October 2001
Unknown
Issued 24 October 2001 Resolved
Install smoke detectors and PA system in overnight passenger compartments. Vessel is restricted from taking overnight passenger until this is completed._x001C_
Condition: Unknown
Due 24 October 2001
Resolved 24 October 2001
Unknown
Issued 24 October 2000 Resolved
CHANGE OUT RUNNING LIGHTS AND ANCHOR LIGHT, MUST MEET UL 1104/46CFR 183.420
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Unknown
Issued 24 October 2000 Resolved
MOVE EPIRB FROM AFT OF LIFE-FLOATS TO SIDE FOR SAFE ACCESS.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Unknown
Issued 24 October 2000 Resolved
LABEL ALL ENGINE ROOM VENT CLOSURES. "ENGINE ROOM VENT, CLOSE IN THE EVENT OF FIRE".
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Unknown
Issued 24 October 2000 Resolved
PROVIDE AND ESCAPE HATCH FORWARD CREW BERTHING. AT NEXT DRYDOCK.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Unknown
Issued 24 October 2000 Resolved
EXERCISE E/R ESCAPE HATCH & LABEL; "EMERGENCY ESCAPE, KEEP CLEAR". IN ENGINE ROOM AND MAIN DECK.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Unknown
Issued 24 October 2000 Resolved
REPAINT ALL LIFEFLOATS INTERNATIONAL ORANGE.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Unknown
Issued 24 October 2000 Resolved
MAKE PERMANENT REPAIRS TO ORBITROL HELM SEAL.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Unknown
Issued 24 October 2000 Resolved
PROVIDE AN APPROVED OR EQUIVILANT FIRST AID KIT/46CFR184.710 & 160.041.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Unknown
Issued 24 October 2000 Resolved
PROVIDE VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Unknown
Issued 27 October 1999 Resolved
PERMANENTLY MARK HULL WITH DRAFT MARKS IN ACCORDANCE WITH 46 CFR 185.602 (c)(1).
Condition: Unknown
Due 27 October 1999
Resolved 27 October 1999
Unknown
Issued 27 October 1999 Resolved
REPLACE 6 EXPIRED DAY AND 6 EXPIRED NIGHT DISTRESS SIGNALS IN ACCORDANCE WITH 46 CFR 180.68 (a)(1)(2).
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 20 April 1999 Resolved
PROVIDE MEANS OF AUTOMATIC DISCHARGE OF E/R FIXED CO2 SYSTEM OR INSTALL USCG APPROVED FIRE DETECTION SYSTEM.
Condition: Unknown
Due 20 April 1999
Resolved 20 April 1999
Fire Fighting
Issued 20 April 1999 Resolved
PROVIDE VENT CLOSURES FOR E/R.
Condition: Unknown
Due 20 April 1999
Resolved 20 April 1999
Construction/Loadline
Issued 20 April 1999 Resolved
RENEW PORT GENERATOR INTAKE VALVE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Lifesaving
Issued 24 October 1997 Resolved
RESTENCIL PFD STORAGE BOXES ON UPPER DECK.
Condition: Unknown
Due 24 October 1997
Resolved 12 November 1997
Lifesaving
Issued 24 October 1997 Resolved
UPDATE FIRST AID KIT.
Condition: Unknown
Due 24 October 1997
Resolved 12 November 1997
Lifesaving
Issued 24 October 1997 Resolved
MOUSE SHACKLE PINS FOR ANCHOR CHAINS.
Condition: Unknown
Due 24 October 1997
Resolved 12 November 1997
Engineering
Issued 24 October 1997 Resolved
RENEW P/S FUEL VENT FLAME SCREENS.
Condition: Unknown
Due 24 October 1997
Resolved 12 November 1997
Documentation
Issued 18 November 1994 Resolved
PROVE THE VESSEL HAS THE REQUIRED VALID FCC SAFETY INSPECTION CERTIFICATE.
Condition: Unknown
Due 18 November 1994
Resolved 18 November 1994
Construction/Loadline
Issued 18 October 1994 Resolved
REPLACE THE TWO SHORT HOSE SECTIONS VICINITY OF PORT MAIN ENGINE BILGE PUMP
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Lifesaving
Issued 18 October 1994 Resolved
STENCIL LIFEJACKET STOWAGE BOXES ON UPPER DECK.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Engineering
Issued 19 October 1992 Resolved
emergency fuel shut off valves must be labeled.
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Lifesaving
Issued 19 October 1992 Resolved
life jacket lockers must be labeled to indicate number of pfds stored in lockers.
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Lifesaving
Issued 19 October 1992 Resolved
affix approved pfd lights to 13 child pfds.
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Engineering
Issued 19 October 1992 Resolved
replace port fuel tank vent flame screen
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Lifesaving
Issued 22 October 1991 Resolved
PROVIDE SUITABLE MEANS FOR RETRIEVAL OF PERSON IN WATER.
Condition: Unknown
Due 1 November 1991
Resolved 31 October 1991
Fire Fighting
Issued 22 October 1991 Resolved
RENEW OR REPAIR PRESSURE GAGE FOR FIRE PUMP DISCHARGE LINE.
Condition: Unknown
Due 1 November 1991
Resolved 31 October 1991
Lifesaving
Issued 24 May 1985 Resolved
PROVIDE 2 ADDITIONAL LIFERING BUOYS.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985

Casualty record · 1

20 October 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4469285
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEVEN B'S V (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.