Records from 2012 to 2025. Most recent: inspection, 29 May 2025.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 29 May 2025
Resolved
A penetration in a watertight bulkhead must be … made watertight. The gate valve in bilge piping for fwd compartment is seized. Replace seized gate valve. CITE: 46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025
Resolved
Observed unsafe practices, fire hazards, and other hazardous situations must be corrected …. Excessive build-up of grease/oil was observed on both generators. De-grease both generator sets’ windings. CITE: 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025
Resolved
All cable and wire must … be installed with metal supports spaced not more than 24” apart. Install metal wire straps every 24". CITE: 46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 29 May 2025
No resolution recorded
Ea watertight bulkhead must be … capable of remaining watertight …. Rotted wood was identified in the transverse floor beam IWO bilge piping thru fwd blkhd in bunk room serving fwd compartment. Made temp repair 02July2025. Make permanent repair at next drydock. CITE: 46 CFR 179.320(a)
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 29 May 2025
Resolved
The number of penetrations in a watertight bulkhead must be minimized. There are unsealed blkhd penetrations in tank room, aft stbd side @ deck. Seal all blkhd penetrations in tank room. CITE: 46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 29 May 2025
Resolved
Ea inlet/dischg pipe that penetrates the hull below 6” above the waterline must have means to prevent water from entering the vessel. The overboard gate valve in tank room, port side just above the chine is seized. Replace the seized gate valve. CITE: 46 CFR 179.350(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025
Resolved
Wires are to be installed … in such a manner as to avoid chafing and other damage. The wire for the high-water alarm float in fwd bunk room interferes w/ the float. Secure loose wiring. CITE: 46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 May 2025
Resolved
Lifesaving equipment must be maintained in serviceable condition. One life float was damaged thru the skin along its length. Properly repair damaged life float. CITE: 46 CFR 180.25(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 May 2025
Resolved
Lifesaving equipment must be maintained in serviceable condition. One life float was severely faded. Properly repaint faded life float w/ hi viz paint. CITE: 46 CFR 180.25(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025
Resolved
Electrical equipment exposed to the weather must be watertight. The port & stbd nav light housings are cracked. Replace both nav light housings w/ appropriate weather-tight UL approved housings. CITE: 46 CFR 183.210(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 6 October 2025
Resolution: Verified new installation of nav lights.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 May 2025
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q. The batteries are expired in the waterlights. Replace all expired waterlight batteries. CITE: 46 CFR 180.70(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verfied in person
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangements rescue boats
Issued 29 May 2025
Resolved
Lifesaving equipment, incl. ring buoys, PFDs, L/F paddles, L/Fs, etc., are to be marked w/ the vessel’s name. The vsl’s name is missing from a number of L/S items. Complete properly mark all life-saving equip w/ vsl’s name. CITE: 46 CFR Part 180
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 May 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. The aspirin is expired. Replace expired aspirin in 1st aid kit. CITE: 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2025
Resolved
The vsl name must be marked on the port & starboard bow & the stern of the vessel. The hailing port must be marked on the stern. The old name is currently on the vessel. Place vsl name on hull. CITE: 46 CFR 67.123 C 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 2 July 2025
Resolution: Verified in person
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 November 2024
Resolved
Inspection of each portable fire extinguisher, semi-portable fire extinguisher, and fixed gas fire extinguishing system to be completed by a certified fire extinguisher servicing agency annually. Annual inspection overdue.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2024
Resolution: 3rd party fire servicing completed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 November 2024
Resolved
A vessel on an oceans, coastwise, limited coastwise, route must carry Six hand red flare distress signals approved in accordance with § 160.021. Flares expired.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2024
Resolution: Expired flares repalced with new
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 4 November 2024
Resolved
Lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter. Lifelines on 01 lifefloat was past its service life.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2024
Resolution: Lifeline replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2024
Resolved
The vessel shall be ready for inspections of fuel piping systems. Leaks found at tank valves to be corrected.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2024
Resolution: Valve packing tightened and tested for leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2024
Resolved
Engine exhaust pipe must be double clamped where practicable. Clamps to be tightened or replaced to prevent leaks
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2024
Resolution: Clamps repaired and system op tested.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 November 2024
Resolved
The EPIRB test required shall be logged or otherwise documented, as applicable. No tests recorded.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 December 2024
Resolution: Epirb tests conducted & logged
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 November 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 December 2024
Resolution: New charts purchased
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 7 November 2023
Resolved
The color of the buoyant apparatus must be primarily vivid reddish orange as defined by sections 13 and 14 of FED–STD–595C. Lifefloat experienced excessive sun damage to outer shell causing for loss of shell, loss of color and degradation of the buoyancy foam.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Replaced buoyant apparatus
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 7 November 2023
Resolved
The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Lanyards have excessive sun damage causing the failure of the line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2023
Resolved 9 November 2023
Resolution: Lines replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 November 2023
Resolved
Each lifeline on a ring life buoy must Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light.Lanyards have excessive sun damage causing the failure of the line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Lines replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 November 2023
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Bilge foot valves seized and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2023
Resolution: Bilge foot valves all opened, inspected cleaned and returned to operation
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 November 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessel storing paint and hazardous material outside of an authorized paint locker.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Removed flammable paints and materials off vessel
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 November 2023
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute and 60 Pounds per square inch. Installed pump only putting out 30 PSI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2023
Resolved 5 July 2024
Resolution: Pump replaced and tested with greater than 60 PSI at the pump using one hose.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 November 2023
Resolved
Vital systems shall be acceptable to the cognizant OCMI, nonferrous metallic piping with a melting temperature above 927 °C (1,700 °F) may be used in vital systems that are deemed to be galvanically compatible. Installed PVC and Flex hose do not meet the melting temperature requirement for vital systems
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2023
Resolved 5 July 2024
Resolution: PVC piping replaced with copper conducted satisfactory test of repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2023
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. STBD Deck rail stanchion loose.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2023
Resolved 8 November 2023
Resolution: Rail stanchions resecured
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 7 November 2023
Resolved
At each inspection for certification and at every other vessel inspection all and all required guards and protective devices must be in satisfactory condition. Port MDE belt drive pump pulley is accessible to crew in engine room main passageway
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 9 November 2023
Resolution: Guard installed at pump pulley
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 May 2023
Resolved
An internal structural exam consists of a complete examinations of a vessel's main strength members including the major framing and planking. Found frame number two aft to fwd on port side of fwd peak cracked on upper section. Found frame number four aft to fwd on port side with some wood decay on upper area IWO deck beam.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 12 June 2023
Resolution: Frames #2, #3, and #4 aft-to-fwd port side repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2022
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead and made watertight. Penetrations in the engine room and collision bulkhead are not watertight.
Action required: 10 - Deficiency Rectified
Due 25 October 2022
Resolved 25 October 2022
Resolution: Penetrations were made watertight.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 October 2022
Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station to indicate high water. The high water alarm in the engine room does not work. Make/log rounds of the engine room every 30 minutes while underway.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 7 November 2022
Resolution: Replaced the high water alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 September 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead, and made watertight. Penetration in the fwd bulkhead, mid-center needs to be made watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2022
Resolved 11 September 2022
Resolution: Hole sealed up in bulkhead
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 27 April 2022
Resolved
Vessels that have overnight accommodations for passengers must submit plans to the cognizant OCMI by 28Mar2022 for the installation and use of a monitoring device to ensure the wakefulness of the watchmen. The monitoring device must ensure the wakefulness of the crew in the event that the watchman is unresponsive; Remain operable during the nighttime watch; and Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. Submit plans to the OCMI by 27May2022.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 13 July 2022
Resolution: Vessel opted to remove overnight passengers from COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2021
Resolved
Each ring life buoy must be marked with Type II retroreflective material as specified in IMO Resolution A.658(16). Ring life buoy retroreflective tape is worn and needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Applied new retroreflective tape to the ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2021
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. 12 adult and 2 child lifejacket markings are illegible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Re-stenciled life jackets with vessel name.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 October 2021
Resolved
All escape hatches shall be marked on both sides "Emergency Exit, Keep Clear". Vessel escape hatch markings are faded and need to be redone.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Re-stenciled escape hatch.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 October 2021
Resolved
A vessel must have a first aid kit approved under 160.041 or equivalent contents stowed in a watertight container marked First Aid Kit. First aid kit has expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Obtained replacements for expired items in first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021
Resolved
Remote fuel shutoff valves shall be marked in 1-inch letters indicating the purpose of the valve and direction of operation. Fuel shut off valves do not indicate the purpose of each valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Fuel shut off valves have been marked to indicate purpose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 October 2021
Resolved
For alternating current generators, a means for measuring frequency shall be provided. Hertz frequency meter is not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Verified hertz frequency meter is now working.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 October 2021
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Wiring for the fan in the forepeak is not marine grade.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 29 October 2021
Resolution: Wiring for the fan in the forepeak has been replaced with marine grade.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 October 2021
Resolved
Wiring joints and spices shall be mechanically secure and made in junction boxes. Enclose or remove dead end wires in the lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 8 November 2021
Resolution: Dead end wires have been placed in an enclosure.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 October 2021
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Freshwater pump is not hardwired and needs cable hangers in the lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 8 November 2021
Resolution: Freshwater pump has been hardwired and has an on/off switch.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 October 2021
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC licensed technician once every 5 years, after which a Communications Act Safety Radiotelephony Certificate will be issued. Vessel does not have a current radiotelephony certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 9 November 2021
Resolution: Obtained new FCC radio safety certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 October 2021
Resolved
Bridge-to-bridge radiotelephone station will be inspected on vessels subject to regular inspections pursuant to the requirements of Parts II and II of Title III of the Communications Act. Vessel does not have a valid bridge-to-bridge FCC certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 9 November 2021
Resolution: Obtained the FCC bridge to bridge certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 20 October 2020
Resolved
Provide evidence of weak link breaking strength for life floats. Identification tag missing on weak link.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 3 February 2021
Resolution: Purchased new weak link for life floats
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2020
Resolved
Electrical outlet not properly secured into bulkhead in tank/CO2 space creating electrical hazard. Properly insert electrical outlet into bulkhead.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 3 February 2021
Resolution: Electrical outlet properly mounted
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 October 2020
Resolved
Valve for fuel filters needs to have cap or plug to prevent fuel leakage. Provide proper cap/plug to satisfaction of CG marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 3 February 2021
Resolution: Plugs installed on fuel filters
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2019
Resolved
A fire hose must be attached at each fire hydrant. The port side fire hose was worn and leaking.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 22 October 2019
Resolution: Provided evidence that the fire hose was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 October 2019
Resolved
Each lifjacket must be marked in clearly legible block capital letters with the vessel's name. 16 life jackets were found with the vessel's name not clearly legible.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 22 October 2019
Resolution: Provided evidence that the 16 lifejackets were properly marked.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 September 2019
Resolved
Smoke detectors expired. Install proper UL217 smoke detectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 23 September 2019
Resolution: New UL217 smoke detectors installed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 September 2019
Resolved
Verify proper wiring of electrical outlets in galley. 46 CFR 183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 23 September 2019
Resolution: Polarity checked using tester. All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 September 2019
Resolved
Provide proper logs per regulations for primary lifesaving maintenance and watchmen rounds.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 7 October 2019
Resolution: Logs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 September 2019
Resolved
Repair/replace lifefloat as discussed. Max persons onboard reduced by 22 persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 23 September 2019
Resolution: New lifefloat installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 September 2019
Resolved
Replace battery for fire detection system. Battery over 10 years old.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Battery replaced.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 August 2018
Resolved
AIS is not correctly broadcasting the correct vessel name.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 14 September 2018
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 October 2017
Resolved
Provide updated Eldridge book.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 13 October 2017
Navigation › Piloting/Steering › Marine Charts
Issued 12 October 2017
Resolved
Provide updated charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 13 October 2017
Fire Fighting › Fire Pumps › Gland Sealing
Issued 12 October 2017
Resolved
Repair main fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 23 October 2017
Electrical › Lighting (service) › Conductor
Issued 18 May 2017
Resolved
Rewire lighting in tank compartment with approved boat/marine cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 6 June 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 18 October 2016
Resolved
Provide GPS information and enter MMSI number into VHF radio.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 29 November 2016
Documentation › Certificates/Documents › FCC SSL
Issued 18 October 2016
Resolved
Provide FCC station license.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 18 October 2016
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › Marine Charts
Issued 18 October 2016
Resolved
Provide updated charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 29 November 2016
Communications › Radio Communications › EPIRB
Issued 18 October 2016
Resolved
Epirb battery expired. Vessel restricted to no more than 3 miles from shore until new epirb battery has been obtained.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 18 October 2016
Resolution: Corrected via proof of purchase, registration, and installation photos.