MAURY USCG vessel records Sign in
← All vessels

ALL THE WAY

ALL THE WAY is a 1984 passenger vessel (uninspected). The Coast Guard has recorded 19 inspections since 1985, most recently in February 2006, along with 17 deficiencies.

Records from 1985 to 2006. Most recent: inspection, 9 February 2006.

Built
1984
Last inspected
9 February 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB8213
231314
Flag
UNITED STATES
366954850 (licence lapsed)
Maury page id
psix-231314

Inspections, by type

…with no type recorded7
Years with a record 12 calendar years (1985–2006)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it21 - Regulatory (Subpart C or D), Net Ton
31 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB8213MMSI 366954850 · expired · compulsorily equipped · granted 8 June 2004, cancelled 9 August 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 19

9 February 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2582535
7 April 2005 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2328261
13 July 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2130853
5 August 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1867274
7 April 2003 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1770157
23 May 2002 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1619612
4 May 2002 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1613810
26 March 2002 Plan Review "T" Boat
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1597547
25 May 2001 COI Inspection · Inclining Experiment · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1470612
25 May 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 665226
24 May 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 665227
28 April 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 99933
10 November 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 46800
14 March 1990 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1225402
28 October 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1021099
7 July 1987 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1024969
9 July 1986 Deficiency Check · Credit Drydock · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1017191
18 July 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1286315
1 May 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 984200

Deficiency record · 17

Engineering › Bilge Water Management System › Piping
Issued 7 April 2005 Resolved
Re-route passenger accommodation electric submersible bilge pump discharge flexible hose assembly. Flexible hose may not penetrate a water tight bulkhead. (46 CFR 182.520(e).
Action required: 705 - Other - as specified
Due 7 May 2005
Resolved 8 April 2005
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 7 April 2005 Resolved
Provide proper ventilation system for port/stbd integral diesel fuel oil storage tanks. (46 CFR 182.450)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2005
Resolved 8 April 2005
Engineering › Bilge Water Management System › Valve
Issued 7 April 2005 Resolved
Install serviceable valve on machinery space electric submersible bilge pump discharge flexible hose at hull penetration. (46 CFR 182.520(e)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2005
Resolved 12 April 2005
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 7 April 2005 Resolved
Make machinery space ventilation closure devices vapor tight. (46 CFR 182.465).
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2005
Resolved 12 April 2005
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 7 April 2005 Resolved
Make forward machinery space bulkhead vapor tight to minimize fire hazards. (Fill all openings) (46 CFR 177.10-5)
Action required: 705 - Other - as specified
Due 7 May 2005
Resolved 12 April 2005
Personnel › Training › First Aid/CPR
Issued 13 July 2004 Resolved
Provide evidence of completion of Red Cross first aid/CPR training for at least 50% of crew as recommended by USCG NVIC 1-91 Recommended Qualifications for Small Passenger Vessel Deckhands.
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 12 April 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 July 2004 Resolved
Provide evidence of annual servicing of portable and fixed fire extinguishers in accordance with NFPA 10 as required by 46 CFR 176.810.
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 12 April 2005
Lifesaving › Visual Distress Signals (General) › Expired
Issued 13 July 2004 Resolved
Provide 6 serviceable hand held red flare distress signals approved in accordance with 46 CFR 160.021as required by 46 CFR 180.68
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 12 April 2005
Lifesaving › Visual Distress Signals (General) › Expired
Issued 13 July 2004 Resolved
Provide 6 serviceable hand held smoke signals approved in accordance with 46 CFR 160.037 as required by 46 CFR 180..68.
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 12 April 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 July 2004 Resolved
Make repairs to the starboard propulsion starting battery box and secure batteries to prevent shifting as required by 46 CFR 183.05-20.
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 12 April 2005
Operations/Management › Equipment Service/Testing › EPIRB
Issued 13 July 2004 Resolved
Conduct monthly test of EPIRB and log test results in accordance with 46 CFR 185.728
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 12 April 2005
Personnel › Training › Familiarization Training
Issued 13 July 2004 Resolved
Record general description of training completed for crew familiarization, fire, man overboard and abandon ship drills as required be 46 CFR 185.402.
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 12 April 2005
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 13 July 2004 Resolved
Provide one child size Type I PFD approved under 46 CFR 160.055 in accordance with 46 CFR 180.71(b)(2) prior to carrying child passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2004
Resolved 12 April 2005
Lifesaving › Rigid Liferafts
Issued 5 August 2003 Resolved
Renew waterlight for lifefloat. LEGACY COMPONENT DESC: Waterlight
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 5 August 2003
Resolution: Owner renewed waterlight for lifefloat.
Deck/Cargo
Issued 7 July 1987 Resolved
THE VESSEL HAS AN AIR COMPRESSOR WHICH IS USED TO FILL SCUBA TANKS. THIS SYSTEM HAS NO PRESSURE RELIEF VALVE IN THE PRESSURE SIDE. INSTALL A SUITABLE RELIEF VALVE IN THE PRESSURE PIPING.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987
Construction/Loadline
Issued 7 July 1987 Resolved
THE AFT PROTION OF THE MAIN DECK IS FRP OVER PLYWOOD AND THE PLYWOOD IS ROTTING AROUND THE DECK HATCH AND NEAR THE TRANSOM. REMOVE TO GOOD WOOD ANDRENEW AS ORIGINAL.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987
Accommodation/Occupational Safety
Issued 18 July 1985 Resolved
THE FORWARD HATCH IN THE SLEEPING QUARTERS IS A REQUIRED MEANS OF ESCAPE AND MUST BE OPERATIONAL FROM EITHER INSIDE OR OUTSIDE. THE PRESENT HATCH ISONLY OPERABLE FROM INSIDE AND NOT PROPERLY LABLED.
Condition: Unknown
Due 18 July 1985
Resolved 18 July 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.