Records from 2010 to 2026. Most recent: inspection, 24 April 2026.
Inspection history · 21
24 April 2026
MSP Additional Oversight - Risk Assessment · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8355146
25 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8304749
29 January 2025
MTSA Verification · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8067623
17 October 2024
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8003610
21 March 2024
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7883072
29 February 2024
Internal Structural Exam · Drydock Exam · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7871813
2 February 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7859855
18 May 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7691474
24 March 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7655421
9 February 2023
Security Breach
Type not classified · Sector New York · USCG Northeast District (CGD-NE) · Activity 7634717
25 February 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7401862
21 January 2022
Drydock Exam · Hull Examination · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7383797
9 March 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7153136
10 February 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6905916
22 January 2020
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6893394
25 January 2019
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6614911
20 April 2018
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6395394
8 February 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6351720
10 March 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6101578
31 March 2016
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5844193
17 February 2016
Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5816930
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 April 2026
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Aft light enclosure was cracked. Replace light enclosure in kind. 46 CFR 183.01-15(a)
(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2026
Resolved 13 May 2026
Resolution: Received photo of replaced light fixture
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2026
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level alarm. Galley space bilge float switch is inoperable and disconnected. Replace bilge float switch. 46 CFR 119.530(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2026
Resolved 19 May 2026
Resolution: Received photo with reinstalled float switch
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2026
Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Bilge strainers were disconnected. Attach bilge strainers.
46 CFR 182.25-5(a)(b)
(OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2026
Resolved 13 May 2026
Resolution: Received photo of all bilge suction strainers reattached
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 January 2025
Resolved
All vessels shall be provided with bilge pumps in accordance with table 182.25-10(a). MI noted the bilge system as inoperable. The PTO off the port main engine was not able to draw suction unless the engine RPM increased.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2025
Resolution: Operator rebuilt pump and replaced impeller. Demo'd sat operation.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 January 2025
Resolved
Electrical apparatus which operates as part of, or in conjunction with, a fire protective device installed on board the vessel shall be tested by operation. MI must observe proper operation of the engine room ventilation power shut off.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2025
Resolution: Witnessed sat vent shutdown and vent closure.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 29 January 2025
Resolved
Electrical apparatus which operates as part of, or in conjunction with, a fire protective device installed on board the vessel shall be tested by operation. MI noted galley power ventilation shut off, but louvers for the dampeners did not close.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2025
Resolution: Witnessed sat vent closure
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 29 January 2025
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Employees not enrolled in chemical testing program may not fill the role of any crewmember. Provide proof of enrollment.
Action required: 705 - Other - as specified
Resolved 7 March 2025
Resolution: Verified employee DAPI enrollment certificate
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 29 January 2025
Resolved
The owner, charterer, master, or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. MI noted crew was unable to determine which valves to open in order to operate the bilge pump. Provide crew training.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 March 2025
Resolution: Bilge system valves labled and crew was trained in operation of bilge system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 January 2025
Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines. MI noted cooling water temperature gauge for STBD generator was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 March 2025
Resolution: New gauge SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 January 2025
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. MI noted cooling water leak from STBD generator expansion tank flexible hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 March 2025
Resolution: Hose was replaced and inspected sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 March 2024
Resolved
"A power driven fire pump must be installed on each mechanically propelled "L" vessel. Vessels fire pump failed to operate. Vessel identified the breaker was not properly labeled and corrected during inspection.
46 CFR 181.10-1 (OLD T)
Action required: 10 - Deficiency Rectified
Resolved 21 March 2024
Resolution: Vessel relabled fire pump breaker. Tested pump. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 March 2024
Resolved
"At each inspection for certification, re inspection MI shall require that all observed unsafe practices and hazardous situations be corrected." MI identified 03 broken windows on the main deck.
46 CFR 176.25-50 (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Vessel replaced broken windows.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 March 2024
Resolved
" The general construction of the vessel shall be such as to minimize fire hazards." MI identified missing Structural Fire Protection missing in Engine Room.
46 CFR 177.10-5 (OLD T)
Action required: 705 - Other - as specified
Resolved 12 April 2024
Resolution: Attended vessel, MI observed missing SFP is now in place.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 March 2024
Resolved
"Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the escape path..." Emergency lighting on second deck was inop. Rectify w/in 7 days.
46 CFR 184.30-5 (OLD T)
Action required: 705 - Other - as specified
Resolved 27 March 2024
Resolution: Received objective photographic evidence of repair.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 March 2024
Resolved
"Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards." MI discovered 03 lights on the main deck broken and missing covers.
46 CFR 120.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2024
Resolution: Received objective photographic evidence of repair.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 March 2024
Resolved
"All escape hatches and other emergency exits must be marked on both sides with "EMERGENCY EXIT, KEEP CLEAR"". MI's observed multiple emergency exits on the main deck, engine room and galley to be missing egress signs. Rectify W/in 7 days.
Action required: 705 - Other - as specified
Resolved 27 March 2024
Resolution: Received objective photographic evidence of repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 February 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel lapsed drydock examination and internal structural anniversary date on 01/31/2024.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 February 2024
Resolution: Conducted Dry Dock and Internal Structural Exam.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 January 2020
Resolved
The vessel security officer (VSO) must keep records of: For each annual audit, a letter certified by the Company Security Officer or the VSO stating the date the audit was completed. Most recent internal security audit documentation was not available at the time of inspection; provide documentation within 7 days.
Action required: 705 - Other - as specified
Due 29 January 2020
Resolved 13 February 2020
Resolution: Received satisfactory copy of 2019 internal security audit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 January 2020
Resolved
Alcohol testing. Collection of an individual's saliva or breath must be taken only by personnel trained to operate the alcohol-testing device. Proof of training was not available at time of inspection; provide proof of training within 7 days.
Action required: 705 - Other - as specified
Due 29 January 2020
Resolved 29 January 2020
Resolution: Received satisfactory proof of training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2020
Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail. #1 and #2 generator in main machinery space did not have protective covers over exposed rotating machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2020
Resolved 19 February 2020
Resolution: Received satisfactory pictures attesting to new installation of protective covers on forward part of generators #1 and #2.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2020
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Light fixtures in waste tank void space and second deck aft weather deck had broken covers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2020
Resolved 27 February 2020
Resolution: Received satisfactory pictures attesting to new installation of light fixture covers in waste tank void space and second deck aft weather deck.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2020
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Electrical connection for high bilge alarm in forepeak was not made within an enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2020
Resolved 21 February 2020
Resolution: Received satisfactory picture attesting to wiring connection made in junction box.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2020
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Marking for maximum passengers allowed on second deck did not match vessel stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2020
Resolved 29 January 2020
Resolution: Received satisfactory proof of revised markings.
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 25 January 2019
Resolved
ALL CREW INVOLVED IN SAFETY OPERATIONS ARE REQUIRED TO BE ENROLLED IN A DAPI PROGRAM. MULTIPLE MEMBERS ON BOARD WERE NOT LISTED ON THE COMPANIES DAPI ROSTER; PROVIDE PROOF OF ENROLLMENT AND COMPLIANCE IN DAPI PROGRAM FOR ALL CREW.
46CFR16.203(a)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 February 2019
Resolution: Documentation provided demonstrating enrollment and compliance with DAPI for crew members.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 25 January 2019
Resolved
EACH SHIP TRANSPORTING MORE THAN SIX PASSENGERS FOR HIRE EQUIPPED WITH A RADIOTELEPHONE STATION, THE RADIO OPERATOR MUST HOLD A MARINE RADIO OPERATOR PERMIT. EACH RADIO OPERATOR MUST PROVIDE A VALID RADIO OPERATORS PERMIT.
47CFR80.159
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 February 2019
Resolution: Vessel captain's MROP provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 25 January 2019
Resolved
AT LEAST 50% OF THE CREW MUST BE CERTIFIED IN CPR/FIRST AID. ONLY ONE CREWMEMBERS CPR/FIRST AID CERTIFICATION WAS PROVIDE; PROVIDE PROOF OF CPR/FIRST AID CERTIFICATIONS FOR THE CREW.
NVIC 1-91
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 February 2019
Resolution: Documentation provided demonstrating crew members meet the CPR training requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 January 2019
Resolved
VESSEL IS REQUIRED 01 RING LIFE BUOY WITH AN ATTACHED FLOATING WATERLIGHT. VESSELS FLOATING WATERLIGHT WAS BROKEN.
46CFR117.70(d)
Action required: 10 - Deficiency Rectified
Resolved 25 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 January 2019
Resolved
THE VESSEL SHALL BE MAINTAINED IN A CONDITION THAT IS FREE FROM HAZARDS AND UNSAFE PRACTICES. THE PORT AND STARBOARD MAIN ENGINE'S ARE LEAKING EXHAUST ON THE OUTBOARD SIDES, CREATING A SITUATION THAT IS HAZARDOUS TO THE CREW AND THE VESSEL.
46CFR176.25-50(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2019
Resolution: MI verified proper operation of MDE's without exhaust leaks.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 31 March 2016
Resolved
Ground indicated on switchboard in E/R @ 4.5-5 amps. Determine and rectify source of ground.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 13 April 2016
Resolution: Ground caused by block heaters, operator removed block heaters to correct deficiency.
Electrical › Lighting (service) › Lighting Fixture
Issued 31 March 2016
Resolved
Unapproved lighting fixtures installed in deck 01 and 02 used for clean up. Light fixtures shall be UL 595 or UL1598a
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 13 April 2016
Resolution: Operator removed light fixtures in question.