MAURY USCG vessel records Sign in
← All vessels

CAPT. ANDERSON IV

CAPT. ANDERSON IV is a 1984 passenger vessel (inspected). The Coast Guard has recorded 89 inspections since 1984, most recently in February 2026, along with 139 deficiencies, 1 operational control and 3 casualty investigations between 2005 and 2021.

Records from 1984 to 2026. Most recent: inspection, 18 February 2026.

Built
1984
Last inspected
18 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK2357
231490
Flag
UNITED STATES
366954830, 367169910 (licence lapsed)
Maury page id
psix-231490

Inspections, by type

…with no type recorded13
Years with a record 40 calendar years (1984–2026)
The 89 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)77.2 ft × 24.3 ft × 8.7 ft
Registered tonnagegross 92 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1984
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD6223MMSI 367169910 · expired · compulsorily equipped · granted 1 March 2007, cancelled 6 May 2017
WDB8211MMSI 366954830 · expired · compulsorily equipped · granted 8 June 2004, cancelled 9 August 2014
WCZ4945MMSI not assigned · expired · compulsorily equipped · granted 10 September 1999, cancelled 14 November 2009 · licensed under a name not among this hull’s recorded names (not shown)
WAD6507MMSI not assigned · expired · compulsorily equipped · granted 21 July 1994, cancelled 26 September 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 89

18 February 2026 Annual Inspection · Deficiency Check · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8312547
23 June 2025 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8165457
11 February 2025 Spot Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8071056
9 December 2024 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8045388
15 May 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7912866
16 February 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7866180
13 June 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7714341
21 February 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7639572
7 February 2023 Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7633557
10 January 2023 Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7619137
31 October 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7586522
28 January 2022 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7387305
11 January 2022 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7378818
15 July 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7257954
23 June 2021 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7249525
22 February 2021 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7144286
3 February 2021 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7139026
24 February 2020 DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6909077
4 April 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6656054
28 November 2018 Plan Review "T" Boat · Damage Survey · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6607510
14 November 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580526
6 June 2018 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6435675
29 January 2018 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6343428
3 January 2018 Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6332720
3 May 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6131818
15 March 2017 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6105335
8 November 2016 Administrative Inspection · Hull Examination · Plan Review "T" Boat · Welding Related Inspections Qualification Testing · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6037738
16 May 2016 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5876521
8 February 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5810449
30 December 2015 Internal Structural Exam · Administrative Inspection · Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5789202
24 March 2014 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4822565
16 March 2010 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3694564
4 January 2010 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3658167
4 December 2009 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3644803
12 February 2009 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3416868
10 February 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3420870
19 July 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3275130
3 June 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3225862
18 December 2007 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3118563
17 May 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2932488
28 February 2007 Construction Oversight · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2892264
10 January 2006 Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2562292
10 May 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2353791
30 April 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2347198
8 June 2004 COI Inspection · Internal Structural Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2091071
24 February 2004 Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2012348
30 October 2003 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1925595
21 May 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1789111
25 April 2002 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1600485
25 April 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1415616
10 May 2000 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1049456
3 May 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1426381
30 April 1999 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1127751
29 October 1998 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1450221
22 April 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1368751
13 August 1997 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1118195
15 April 1997 Deficiency Check · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1404420
9 April 1997 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1103878
16 April 1996 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1416288
28 May 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 878719
6 April 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1159807
29 March 1995 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1407443
19 May 1994 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1449687
12 May 1994 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1362978
17 May 1993 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1138456
13 July 1992 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1261715
21 May 1992 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 958095
15 May 1991 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 929689
15 May 1991 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1241154
6 December 1990 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 920445
31 May 1990 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 916080
30 October 1989 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 975452
14 July 1989 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1044497
23 May 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1350439
15 May 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1348408
24 May 1988 COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 887741
5 January 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1317264
15 May 1987 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1003019
12 May 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1314288
3 July 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 993330
5 June 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 994290
16 May 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1294489
4 April 1986 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1300564
7 June 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 981777
24 May 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982116
17 May 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 978329
10 May 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 978328
22 March 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982473
16 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977304

Deficiency record · 139

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 February 2026 Resolved
Vessel is working on 02 life floats. 25 person life float needs new netting in basket and 22 person life float needs new strapping around periphery of float. Vessel limited to 100 total persons until all life floats are ready for service.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 2 March 2026
Resolution: Vessel removed the float from the vessel and total persons allowed will be reduced to 125.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 18 February 2026 Resolved
Emergency escape scuttle for engine room needs labeling at both points of access.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2026
Resolved 2 March 2026
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 February 2024 Resolved
Both generators are rated for 40 Celsius and needs to be derated to 80% full load rating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2024
Resolved 29 February 2024
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 February 2024 Resolved
Each life float paddle must be lashed to the float. All paddles are not lashed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2024
Resolved 29 February 2024
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 16 February 2024 Resolved
The vessel must be equipped with the appropriate amount of DSC radios for the route specified on the COI. The HF/SSB radio has been removed. The route requires at a minimum 1-VHF and 1-MF radio. The vessel is restricted to not more than 20NM from shore until corrected or until an acceptable alternative is presented.
Action required: 705 - Other - as specified
Resolved 15 May 2024
Resolution: Implemented the use of a Sat Phone. Still Awaiting FCC waiver.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2023 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Witnessed excessive oil leakage underneath both engines. Provide evidence of correction.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2023
Resolved 14 June 2023
Resolution: Received photographs from vessel operator of correction.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 7 February 2023 Resolved
Coast Guard inspectors found that the discharge line for the fire pump is leaking over electrical equipment in the engine room, creating an electrical hazard. Provide evidence that the fire pump discharge line has been corrected and does not leak.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2023
Resolved 21 February 2023
Resolution: Fire main repaired.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 February 2023 Resolved
Inspected small passenger vessels that operate on coastwise or oceans routes must have an interconnected fire detection system installed in an all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces to be installed by December 27th, 2022. Provide evidence of installation and that the fire-detection system has been approved. Until installed, the vessel is now restricted to a Limited Coastwise route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2023
Resolved 21 February 2023
Resolution: Smoke detection installed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 7 February 2023 Resolved
Glass and other glazing material used in windows accessible to passengers and crew must be of material that will not break into dangerous fragments if fractured. Coast Guard inspectors found 02 broken windows on the Main Deck in need of repair. Provide evidence of repaired windows.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2023
Resolved 21 February 2023
Resolution: Windows renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 January 2022 Resolved
Starboard engine room scuttle missing dogs. Replace missing arm.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 28 January 2022
Resolution: Verifed scuttle dog was attached.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 11 January 2022 Resolved
Light switch at entrance to center void is wasted. Replace cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 28 January 2022
Resolution: Verifed switch was repalced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 January 2022 Resolved
Replace quarter turn valve with screw down valve aft of collision bulkhead.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 28 January 2022
Resolution: Attended vessel and witnessed test of bilge pump, pulling suction from storage room bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 January 2022 Resolved
Verify operation of bilge system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 28 January 2022
Resolution: Witnessed bilge pump operational test.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 January 2022 Resolved
Service lifefloat coating as per manufacturer's recommendation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 28 January 2022
Resolution: Verifed that all lifefloats were satisfactory coated as per manufacturer's recommendation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 January 2022 Resolved
Freshwater pump switch broken. Replace/renew switch.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 28 January 2022
Resolution: Verifed new installation of Freshwater pump switch.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 22 February 2021 Resolved
Replace topside Lifelight attached to the forwardmost lifefloat. Repair and provide proof of proper installation and/or operating condition of lifelight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 17 March 2021
Resolution: Light repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 22 February 2021 Resolved
Install latches for the Galley and Bridge refrigerators. Provide proof of installation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 17 March 2021
Resolution: Latches installed.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 22 February 2021 Resolved
Provide proof of spanner wrenches onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 17 March 2021
Resolution: Spanner wrench provided.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 22 February 2021 Resolved
Repair emergency lighting in the Main Deck. Provide proof of repair and proper light operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 17 March 2021
Resolution: Emergency lighting repaired.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 22 February 2021 Resolved
Repair Engine Room Rudder Angle Indicator.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 17 March 2021
Resolution: Indicator repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 February 2021 Resolved
Remove Soft Patches from Bilge Piping.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 17 March 2021
Resolution: Soft patches removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 February 2021 Resolved
Install Machine Guard for Center Main Diesel Engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 17 March 2021
Resolution: Guard installed.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 8 February 2021 Resolved
A vsl installed with a sanitation device must comply with 33CFR part 159, where there must be a means to secure the device to prevent any discharge of sewage. Observed the overboard discharge valve did not have a means to be locked/secured. Provide means to secure the discharge valve meetign requirements of 33CFR159.7(b)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2021
Resolution: Recieved pictures of the overboard discharge valve being secured in the closed position with a lock and chain. all sat
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 24 February 2020 Resolved
Ensure anchor chain shackles are onboard
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2020
Resolved 24 March 2020
Resolution: Owner added anchor chain shackles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 February 2020 Resolved
Replace/Renew exhaust raw water discharge on both main engines.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2020
Resolved 24 March 2020
Resolution: Owner had technician replace exhaust water discharge risers on both main engines.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 February 2020 Resolved
Replace/Renew JB Weld on fire main pipe sections.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2020
Resolved 24 March 2020
Resolution: Owner replaced piping on fire main, tested all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 February 2020 Resolved
Replace/Renew gaskets on all doors going into salon/parlor.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2020
Resolved 24 March 2020
Resolution: Owner renewed weather strip gaskets on parlor doors.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2020 Resolved
Replace handle on port fire main valve on deck.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2020
Resolved 24 March 2020
Resolution: Owner replaced hanle on port fire main valve on deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2020 Resolved
Remove excessive grounds on main engine
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2020
Resolved 24 March 2020
Resolution: Owner removed excessive grounds on main engine.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2020 Resolved
Repair/Replace/Renew overhead insulation on overhead in engine room.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2020
Resolved 24 March 2020
Resolution: Owner repaired overhead insulation in engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 February 2020 Resolved
Repair/Replace stop solenoid on port engine.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2020
Resolved 24 March 2020
Resolution: Owner replaced stop solenoid on port engine.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 24 February 2020 Resolved
Properly demonstrate a man overboard drill prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2020
Resolved 26 February 2020
Resolution: Got underway and observed satisfactory man overboard drill.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 April 2019 Resolved
Emergency fuel oil shut-off valve reach rod inoperative. Repair as necessary.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 April 2019
Resolution: Repaired reach rod and gears,tested operation, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2019 Resolved
Engine room Ventilation Cover on port side missing. Replace and install.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2019
Resolution: Replaced vent cover, tested operation all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2019 Resolved
Vessel has been out of service for storm damage and may not operate until MSD Panama City conducts and issues a Certificate of Inspection.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2019
Resolution: Conducted annual inspection, endorsed COI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 November 2018 Resolved
Due to damages sustained during Hurricane Michael a repair plan must be submitted to Sector Mobile detailing proposed repairs prior to starting work. All repairs are to be verified by an attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2018
Resolution: Vessel safely arrived in Bayou La Batre, AL
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 November 2018 Resolved
Due to the vessel's grounding the vessel is required to be dry docked for a full damage survey.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2019
Resolution: Vessel completed satisfactory drydock inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 November 2018 Resolved
Vessel is permitted to transit to Bayou La Batre via the ICW. Once underway the vessel is to check in with the local CG Communications Center every 2 hours until arrival at their final destination. Any change in the vessel's condition or failure of equipment shall be immediately reported to the nearest OCMI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2018
Resolution: Vessel arrived safely in Bayou La Batre
Engineering › Bilge Water Management System › Interface Detector
Issued 29 January 2018 Resolved
Repair / Replace submersible bilge pump indicating light
Action required: 705 - Other - as specified
Due 13 February 2018
Resolved 12 February 2018
Resolution: Vessel replaced bilge pump indicating light
Documentation › Certificates/Documents › FCC SSL
Issued 29 January 2018 Resolved
Provide valid copy of FCC operator license
Action required: 705 - Other - as specified
Due 13 February 2018
Resolved 12 February 2018
Resolution: Vessel Captain provided valid FCC operator license
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 29 January 2018 Resolved
Make permanent repair to leak on generator muffler in steering compartment.
Action required: 705 - Other - as specified
Due 13 February 2018
Resolved 12 February 2018
Resolution: Vessel repaired muffler leak.
Construction/Loadline › Hull › Weld
Issued 3 January 2018 Resolved
Repair the cracked weld in the upper PORT aft corner in the steering gear space
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 12 February 2018
Resolution: Vessel repaired weld in steering gear space
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 3 January 2018 Resolved
Repair the draft mark readings FWD and AFT
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 12 February 2018
Resolution: Vessel repaired draft marks readings
Engineering › Bilge Water Management System › Piping
Issued 1 February 2017 Resolved
FWD void piping for fixed system is not installed properly. Make repairs for proper operation.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2017
Resolved 15 March 2017
Resolution: Witnessed
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 1 February 2017 Resolved
Engine exhaust was found to have leaks and cracks. Owner stated they wanted to make repairs at home port. MSD Panama City Beach will monitor and clear.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2017
Resolved 15 March 2017
Engineering › Bilge Water Management System › Pump
Issued 24 May 2016 Resolved
Replace Laz bilge pump
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 24 May 2016
Resolution: Bilge pump was replaced
Lifesaving › Lifefloat › Serviceable
Issued 16 May 2016 Resolved
Starboard Life Float has crack.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 3 August 2016
Resolution: The crack was fixed.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 16 May 2016 Resolved
Starboard aux pump tighten or replace belt.
Condition: Improper/Lack of Maintenance
Due 24 May 2016
Resolved 24 May 2016
Resolution: Belt was tightened.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 16 May 2016 Resolved
Replace fire extinguisher hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 24 May 2016
Resolution: Hose was replaced
Engineering › Compressed Air System (start air) › Compressor
Issued 16 May 2016 Resolved
Hard wire air compressor
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 24 May 2016
Resolution: Air compressor is hard wired.
Construction/Loadline › Hull › Bottom Plating
Issued 7 January 2016 Resolved
Found holes in bottom plating near bearing shafts. Could not see extent of damage due to bilges being soiled. Clean all bilges of debris IAW 46 CFR 176.610 and perform ultrasonic testing of affected areas IAW 46 CFR 176.840. Once bilges are cleaned a marine inspector will conduct a hull inspection IAW 46 CFR 176.840.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2016
Resolution: All areas of bad pitting were croped and renewed with original scantling. Tested all inserts satisfactory.
Electrical › Electric Supply System (service) › Cable
Issued 24 March 2014 Resolved
Replace all wingnuts on batteries with locking washers and nuts.
Condition: Placed in Improper Service
Due 1 April 2014
Resolved 25 March 2014
Lifesaving › Lifefloat › Lifeline
Issued 24 March 2014 Resolved
Replace line on 1 life float. Max passenger count reduced by 25 persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2014
Construction/Loadline › Hull › Hull Plating
Issued 4 December 2009 Resolved
not to sail with passengers until completion of dry-dock exam after midnight 31DEC2009
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 January 2010
Resolved 12 January 2010
Resolution: Completed dry-dock exam 12 JAN 2010
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 12 February 2009 Resolved
Improper set up of berthing accommodations!
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 13 February 2009
Resolution: Overnight acommodations have been taken off vessel, all SAT.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 3 June 2008 Resolved
Only 65 adult and 15 children life preservers with satisfactory water lights remained on board. Vessel restricted to carrying 62 Adult passengers and 15 children + 3 crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 11 June 2008
Resolution: 39 water lights were bought for the PFD''''s taken of the vessel.
Lifesaving › Lifefloat › Paddle
Issued 17 May 2007 Resolved
Properly label paddles for (2) bottom lifefloats in stacks on pilot house.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 30 May 2007
Resolution: Paddles have been properly labeled.
Lifesaving › Lifefloat › Markings
Issued 17 May 2007 Resolved
Properly label all (5) lifefloats with capacity.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 30 May 2007
Resolution: Lifefloats have been properly labeled with capacity.
Lifesaving › Lifefloat › Lifeline
Issued 17 May 2007 Resolved
Replace wasted lifeline around top/stbd lifefloat.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 30 May 2007
Resolution: Wasted line has been replaced.
Engineering › Bilge Water Management System › Valve
Issued 17 May 2007 Resolved
Properly secure bracket for reach rod to valve for bilge suction in forepeak compartment.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 30 May 2007
Resolution: Bracket for reach rod properly secured, tested valve operation, SAT.
Fire Fighting › Fire Hydrants › Location/Position
Issued 17 May 2007 Resolved
Re-stencil placard for fire stations.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 30 May 2007
Resolution: Fire stations properly labeled.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 May 2007 Resolved
Properly attach waterlights around body of lifefloats (5).
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 30 May 2007
Resolution: Waterlights have been properly attached to lifefloats.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 May 2007 Resolved
Replace wasted lagging on exhaust risers for port & stbd main diesel engines.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 30 May 2007
Resolution: Wasted lagging on exhaust risers replaced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 April 2006 Resolved
Must prove proper operation of visual indicator for bilge high level alarm.
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 4 May 2006
Resolution: Proper operation of bilge high level alarms witnessed by attending marine inspector.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 April 2006 Resolved
Must conduct satisfactory underway check ride.
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 4 May 2006
Resolution: Completed satisfactory underway checkride complete with fire drill and MOB drill.
Fire Fighting › Fire Hoses › Condition
Issued 8 June 2004 Resolved
Missing fire hose stbd fire station.
Action required: 705 - Other - as specified
Due 15 June 2004
Resolved 15 June 2004
Resolution: New fire hose installed in way of stbd fire station.
Documentation › Markings/Placards › Capacity Marking
Issued 8 June 2004 Resolved
Provide max passenger capacity placard for upper deck.
Due 15 June 2004
Resolved 15 June 2004
Resolution: Max passenger capacity placard installed on upper deck.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 June 2004 Resolved
Exposed wires port side, in way of public address system speakers.
Due 15 June 2004
Resolved 15 June 2004
Resolution: Public address speakers replaced with new, all wiring properly installed & secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 June 2004 Resolved
Secure dead end wiring #2 compartment at water pump.
Due 15 June 2004
Resolved 15 June 2004
Resolution: Dead end wire removed.
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 8 June 2004 Resolved
Remove stowed materials from accommodation space and head areas.
Due 15 June 2004
Resolved 15 June 2004
Resolution: All materials stowed in accommodation spaces and head areas removed.
Construction/Loadline › Penetrations › Valve Flange
Issued 8 June 2004 Resolved
Non operational brass valve stbd side in way of #2 compartment not capped off.
Due 15 June 2004
Resolved 15 June 2004
Resolution: Brass valve stbd side in way of #2 capped off.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 June 2004 Resolved
Bilge high level alarm in way of lazarette compartment inoperable.
Due 15 June 2004
Resolved 15 June 2004
Resolution: Bilge high level alarm replaced with new, tested operational.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 8 June 2004 Resolved
Bilge pump in way of lazarette compartment inoperable.
Due 15 June 2004
Resolved 15 June 2004
Resolution: Witnessed operation of bilge pump in way lazarette compartment.
Documentation › Certificates/Documents › Stability Letter
Issued 8 June 2004 Resolved
Stability letter not posted.
Due 15 June 2004
Resolved 15 June 2004
Resolution: Stability letter posted in wheelhouse.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 8 June 2004 Resolved
Provide and implement waste management plan.
Due 15 June 2004
Resolved 15 June 2004
Resolution: Waste managemnet plan generated and implemented.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 June 2004 Resolved
Mark lifejacket stowage space aft of pilothouse with vessel name.
Due 15 June 2004
Resolved 15 June 2004
Resolution: Lifejacket stowage space aft of pilot house properly marked as lifejacket stowage space.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 April 2004 Resolved
Welds along bottom of logitudnal frame in way of stbd aft corner found fractured.
Action required: 705 - Other - as specified
Resolved 27 April 2004
Resolution: Fractured welds veed and rewelded.
Lifesaving
Issued 3 May 2000 Resolved
Carriage limited to 140 adult passengers pending proof of receipt of nine (09) additional adult size lifejackets
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 30 April 1999 Resolved
Install and prove proper operation of bilge high level alarm system.
Condition: Unknown
Due 15 May 1999
Resolved 15 May 1999
Electrical
Issued 30 April 1999 Resolved
Install metallic wiring supports for engine room cable runs.
Condition: Unknown
Due 15 May 1999
Resolved 15 May 1999
Lifesaving
Issued 30 April 1999 Resolved
Vessel limited to 128 passengers pending proof of receipt of 21 replacementlifejackets.
Condition: Unknown
Due 15 May 1999
Resolved 15 May 1999
Electrical
Issued 30 April 1999 Resolved
Replace damaged non-marine type receptacle just below engine room escape hatch with marine type.
Condition: Unknown
Due 15 May 1999
Resolved 15 May 1999
Engineering
Issued 22 April 1998 Resolved
INSTALL A MACHINERY GUARD IN WAY OF EXPOSED BELTS ON PORT MAIN ENGINE.
Condition: Unknown
Due 22 May 1998
Resolved 22 May 1998
Documentation
Issued 22 April 1998 Resolved
PROVID PROOF OF USER FEE PAYMENT.
Condition: Unknown
Due 22 May 1998
Resolved 19 May 1998
Documentation
Issued 22 April 1998 Resolved
PROVIDE PROOF OF ENROLLMENT IN A DRUG TESTING PROGRAM.
Condition: Unknown
Due 22 May 1998
Resolved 22 May 1998
Documentation
Issued 22 April 1998 Resolved
VESSEL IS RESTRICTED TO OPERATIONS WITHIN 1000FT. FROM SHORE UNTIL FCC GREAT LAKES CERTIFICATE IS PROVIDED.
Condition: Unknown
Due 22 May 1998
Resolved 19 May 1998
Construction/Loadline
Issued 16 April 1996 Resolved
MAKE LAZARRETTE BILGES READY FOR INSPECTION.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Electrical
Issued 16 April 1996 Resolved
REMOVE ALL NON-MARINE GRADE WIRING THROUGHOUT VESSEL OR PROVE INSTALLED WIRE TO BE MARINE GRADE QUALITY.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Lifesaving
Issued 16 April 1996 Resolved
REPLACE PENDANT LINES ON BUOYANT APPARATUS IN ACCORDANCE WITH 46CFR160.010-3.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Construction/Loadline
Issued 16 April 1996 Resolved
MAKE ONE STUFFING TUBE CONTAINING TWO SPEAKER WIRES WATERTIGHT WHERE IT PASSES THROUGH THE FORWARD ENGINEROOM BULKHEAD.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Engineering
Issued 16 April 1996 Resolved
MOUNT AND HARDWIRE OR REMOVE BENCH GRINDER IN ENGINEROOM.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Lifesaving
Issued 16 April 1996 Resolved
RENEW 02 RING BUOYS. INSURE REQUIRED 2" RETROREFLECTIVE IS INSTALLED.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Electrical
Issued 16 April 1996 Resolved
REMOVE INSTALLED OUTLET STRIP UNDER PILOTHOUSE DOOR.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Fire Fighting
Issued 16 April 1996 Resolved
RENEW 02 DEFECTIVE FIREHOSES
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Lifesaving
Issued 16 April 1996 Resolved
COMPLETE FIRE, MAN OVERBOARD AND FLOODING DRILLS TO THE SATISFACTION OF THEOCMI.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Accommodation/Occupational Safety
Issued 16 April 1996 Resolved
MOUNT AND HARDWIRE SEWAGE PUMP IN LAZARRETTE.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Unknown
Issued 16 April 1996 Resolved
MAKE LAZARETTE BILGES READY FOR INSPECTION _x001C_ CREATED IN ERROR AS A DUPLICATE OF DISCREPANCY 009. DISREGUARD THIS REQUIEMENT ENTRY.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Construction/Loadline
Issued 16 April 1996 Resolved
DETERMINE EXTENT OF DAMAGE TO STARBOARD AFT CORNER OF SIDE SHELL PLATING WHERE IT MEETS THE MAIN DECK. PROVIDE RESULTS AND PLANS FOR REPAIR TO OCMICHICAGO FOR APPROVAL.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Navigation
Issued 16 April 1996 Resolved
PROPERLY INSTALL RUDDER ANGLE INDICATOR FEEDBACK ROD IN LAZARRETTE
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Electrical
Issued 16 April 1996 Resolved
HARDWIRE OR REMOVE 12 VOLT LIGHT IN ENGINEROOM.
Condition: Unknown
Due 16 May 1996
Resolved 24 May 1996
Navigation
Issued 29 March 1995 Resolved
Provide a current magnetic compass deviation table for the vessel.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Engineering
Issued 19 May 1994 Resolved
Clean fuel tank vent flame screens.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Documentation
Issued 19 May 1994 Resolved
Obtain placard required by 33 CFR 151.59, garbage-dumping placard.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Lifesaving
Issued 19 May 1994 Resolved
Replace & stencil broken paddles for lifefloats.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Lifesaving
Issued 19 May 1994 Resolved
Provide proof of breaking strength of float-free links on all lifefloats.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Lifesaving
Issued 19 May 1994 Resolved
Stencil vessel name & capacities on all lifefloats.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Lifesaving
Issued 19 May 1994 Resolved
Install dividers between stacked lifefloats.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Lifesaving
Issued 17 May 1993 Resolved
REPLACE IN KIND THE DAMAGED FLOOR OF THE WELIN LIFE FLOAT.
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Documentation
Issued 17 May 1993 Resolved
PROVIDE CURRENT COPIES OF THE FOLLOWING: LIGHT LIST, COAST PILOT, 46CFR PARTS 166-199, RULES OF THE ROAD AND APPLICABLE CHARTS.
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Lifesaving
Issued 21 May 1992 Resolved
RENEW FLOOR IN 22 PERSON LIFEBOAT.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Electrical
Issued 15 May 1991 Resolved
REMOVE DEAD-END CABLE AND UNUSED JUNCTION BOX UNDER FRESH WATER PUMP IN FORWARD STROEROOM.
Condition: Unknown
Due 15 May 1991
Resolved 15 May 1991
Unknown
Issued 15 May 1991 Resolved
PROVIDE WATERLIGHTS FOR 22 EACH ADULT PFD'S. VESSEL IS RESTRICTED IN ITS ROUTE TO VOYAGES NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 15 May 1991
Resolved 15 May 1991
Construction/Loadline
Issued 15 May 1991 Resolved
REMOVE PLASTIC DRYER VENT AND CLOSE OFF AND MAKE WATERTIGHT, THE OPENING INTHE SIDE SHELL OPENING.
Condition: Unknown
Due 15 May 1991
Resolved 15 May 1991
Lifesaving
Issued 15 May 1991 Resolved
PROVIDE THE FOLLOWING FOR THE 3 EACH EXTRA 22 PERSON WELIN DAVIT AND BOAT LIFE FLOATS: A-MARK WITH VESSEL'S NAME AND CAPACITY, B-TWO PADDLES PER LIFE BLOAT, C-ONE PAINTER PER LIFE FLOAT, AND D-ONE WATERLIGHT PER LIFE FLOAT.
Condition: Unknown
Due 15 May 1991
Resolved 15 May 1991
Lifesaving
Issued 15 May 1991 Resolved
INSTALL NEW NETTING IN 12 PERSON LIFE FLOAT.
Condition: Unknown
Due 15 May 1991
Resolved 15 May 1991
Lifesaving
Issued 23 May 1989 Resolved
PROVIDE 2 ADDITIONAL PADDLES FOR LIFEFLOATS.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Fire Fighting
Issued 23 May 1989 Resolved
HYDRO ALL 4 BII FIRE EXTINGUISHERS.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Engineering
Issued 23 May 1989 Resolved
PROVIDE FLAME DEFLECTORS FOR RACOR FUEL FILTERS ON BOTH MAIN ENGINES AND BOTH GENERATORS.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Documentation
Issued 23 May 1989 Resolved
PROVIDE NEW DOCUMENTATION AND CHANGE OF OWNERSHIP.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Lifesaving
Issued 23 May 1989 Resolved
REFASTEN FLOAT FREE LINKS TO SEA PAINTERS.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Navigation
Issued 23 May 1989 Resolved
PROVIDE NEW EPIRB - VESSEL RESTRICTED TO NO MORE THAN 20 MILES OFFSHORE UNTIL EPIRB IS ON BOARD.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Accommodation/Occupational Safety
Issued 23 May 1989 Resolved
PROVIDE VALVE HANDLE FOR WATER VALVE ON PORT HEAD. PASSENGERS REDUCED TO 49 UNTIL REPAIRED.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Navigation
Issued 23 May 1989 Resolved
PROVIDE CHARTS FROM DELAWARE BAY SOUTH TO FLORIDA AND THE GULF OF MEXICO
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Navigation
Issued 24 May 1988 Resolved
TIGHTEN UP ON THE PORT AND STARBOARD RUDDER POST PACKING GLANDS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Accommodation/Occupational Safety
Issued 24 May 1988 Resolved
REPAIR AND MAKE OPERABLE BOTH TOILET FACILITIES. UNTIL THIS IS COMPLETED THE VESSEL IS LIMITED TO 49 PASSENGERS.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Engineering
Issued 24 May 1988 Resolved
PROPERLY MARK THE LOCATIONS FOR THE EMERGENCY FUEL SUPPLY SHUT OFF VALVES AND MARK THE LOCATIONS OF THE LIFEJACKET LOCKERS.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Navigation
Issued 24 May 1988 Resolved
PROVIDE ALL APPLICABLE CHARTS AND PUBLICATIONS FOR THE REQUESTED ROUTE OF THE SUBJECT VESSEL.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Lifesaving
Issued 24 May 1988 Resolved
PROVIDE ONBOARD ONE ADDITIONAL LIFERING PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Engineering
Issued 24 May 1988 Resolved
CLEAN THE MACHINERY SPACE BILGES OF ALL OIL ACCUMULATION AND STOW LUBE AND HYDRAULIC OIL SUPPLIES PROPERLY PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Fire Fighting
Issued 24 May 1988 Resolved
PROVIED ONE 1 1/2 INCH FIREHOSE PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Unknown
Issued 15 May 1987 Resolved
PRIOR TO CARRYING PASSENGERS PROVIDE (A) NOZZLE FOR PORTSIDE FIRE STATION (B) PADDLES FOR SINGLE LIFEFLOAT.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Lifesaving
Issued 15 May 1987 Resolved
RENEW GRABLINE ON STARBOARD AFT RING BUOY.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Lifesaving
Issued 15 May 1987 Resolved
PRIOR TO SAILING OCEANS, PROVIDE PFD LIGHTS FOR 85 LIFEJACKETS ON LOWER DECK.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Electrical
Issued 15 May 1987 Resolved
RENEW WIRING ON BILGE PUMP FOR FISH HOLD.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Construction/Loadline
Issued 16 May 1986 Resolved
RENEW VENT BALL CHECKS OF WATERTIGHT TYPE THROUTHOUT VESSEL WHERE MISSING.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Construction/Loadline
Issued 16 May 1986 Resolved
MAKE ENGINE ROOM EMERGENCY ESCAPES OPERABLE.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Construction/Loadline
Issued 16 May 1986 Resolved
PROVIDE CHAINS OR EQUIVALENT FROM TOPSIDE HATCHES TO HULL.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Engineering
Issued 22 March 1985 Resolved
FUEL UP REACH RODS FOR FOREPEAK BILGE SUCTION VALVE AND EMERGENCY FUEL OIL SUCTION VALVE.
Condition: Unknown
Due 22 March 1985
Resolved 22 March 1985
Documentation
Issued 22 March 1985 Resolved
PROVIDE ON BOARD THE FOLLOWING UPDATED OR CURRENT PUBLICATIONS: CHARTS TO COVER ROUTE, COAST PILOT, AND TIDE TABLES.
Condition: Unknown
Due 22 March 1985
Resolved 22 March 1985

Casualty record · 3

30 April 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2347198
19 July 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3275130
23 June 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7249525
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

WHALE WATCHER II (2005), NORTH STAR EXPRESS (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.