Records from 1985 to 2026. Most recent: inspection, 17 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 50
17 April 2026
Annual Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8351513
9 February 2026
Vessel Attendance · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8307973
6 May 2025
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8129992
9 May 2024
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7909682
12 May 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7692144
13 May 2022
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7459628
26 July 2021
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7268753
20 May 2021
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7205293
12 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7194217
7 May 2020
COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6949983
31 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6699732
15 May 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6418033
2 May 2017
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6138343
6 April 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5849353
7 May 2008
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3202878
2 May 2007
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2921761
12 June 2006
Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2678823
2 May 2006
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2637962
20 April 2005
COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2336990
11 May 2004
Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 2064203
24 April 2003
Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1779555
16 May 2002
Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1618038
29 April 2002
Annual Inspection · Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1668177
9 May 2001
Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1389403
13 June 2000
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1053317
2 May 2000
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1053316
10 May 1999
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1132112
3 May 1999
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 793082
19 May 1998
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 793286
7 November 1997
Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 784870
6 May 1997
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1101767
30 April 1996
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1082387
18 April 1995
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1168104
27 October 1994
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1409220
5 May 1994
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1168957
3 June 1993
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1136118
4 May 1993
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 963135
13 October 1992
Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1270031
21 April 1992
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1257476
17 April 1991
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 911476
17 April 1991
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1212721
8 May 1990
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 912630
10 April 1990
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1226011
20 April 1989
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1042749
7 March 1989
Damage Survey
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 890660
12 April 1988
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1338145
30 September 1987
Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1011322
20 April 1987
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1007828
21 April 1986
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1003190
15 April 1985
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 982365
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025
Resolved
Lanyard on lifebuoy with waterlight was too short. Owner provided a longer lanyard prior to departure from the vessel.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 May 2025
Resolved 6 May 2025
Resolution: Owner provided a longer lanyard prior to departure from the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2025
Resolved
Vessel unable to draw suction from the forepeak due to the pump losing prime. Prove proper operation of the bilge suction system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 14 May 2025
Resolution: Check valves in the branch lines were renewed. System worked as designed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2024
Resolved
Multiple dead end wires in electrical closet under wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 17 May 2024
Resolution: Operator sent photographs of wires secured.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 May 2022
Resolved
Upper deck capacity sign is faded and needs to be renewed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 13 July 2022
Resolution: Signs have been renewed.
Lifesaving › Lifebuoys › Serviceable
Issued 8 June 2016
Resolved
Vsl's FWD and AFT ring buoys were is unsatisfactory condition, replace ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 24 June 2016
Resolution: Vessel rep provided purchase invoise for new ring buoys.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 7 May 2008
Resolved
Provide proper documentation proving pre employment drug testing for all crew prior to carrying passengers in accordance with 46 CFR 16.230.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2008
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2007
Resolved
Provide Proper first aid kit in accordance with 46 CFR 184.710. Currently the vessels kit is incomplete and contains outdated consumables.
Condition: Improper/Lack of Maintenance
Due 2 June 2007
Resolved 17 May 2007
Resolution: Received a fax with a receipt for the replacement items for the First Aid Kit.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 2 May 2007
Resolved
Provide proper upper deck passenger capacity placard in accordance with 46 CFR 185.602 or provide fixed seating plan for USCG approval. Currently the vessels current placard lists 72 passengers, Area measurements allow for 43 passengers.
Condition: Improper Installation
Due 2 June 2007
Resolved 17 May 2007
Resolution: Received a fax from the vessel operator with a receipt for the required updated passenger capacity placard.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 May 2007
Resolved
Provide proper vessel specific emergency instructions in accordance with 46 CFR 185.510. Current vessel emergency instructions are generic in nature and do not address specific design features of the vessel.
Condition: Placed in Improper Service
Due 2 June 2007
Resolved 17 May 2007
Resolution: Received a fax from the vessel operator with the Updated Emergency Procedures.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 May 2004
Resolved
Prove Proper operation of ring buot waterlight.
Due 11 May 2004
Resolved 11 May 2004
Resolution: New battery installed, all sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 May 2004
Resolved
Prove proper operation of anchor light.
Due 11 May 2004
Resolved 11 May 2004
Resolution: Corrected prior to end of inspection.
Engineering › Fuel Oil Service System
Issued 24 April 2003
Resolved
Replace fuel oil supply and return flex hoses on the ship service diesel generator with Coast Guard approved flex hose, I.A.W. 46 CFR 182.720. LEGACY COMPONENT DESC: Hose
Due 24 May 2003
Resolved 11 May 2004
Resolution: Approved Parker hoses installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 April 2003
Resolved
Service all portable fire extinguishers, I.A.W. 46 CFR 176.810(b)(1), prior to operating with passengers for hire. LEGACY COMPONENT DESC: Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2003
Resolved 25 April 2003
Resolution: Fire extinguishers serviced by Fire and Safety Equipment of Wautoma, WI.
Electrical › Electrical Distribution System (service)
Issued 29 April 2002
Resolved
Install proper amp meters for vsl s.s. generator. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Unknown
Due 15 July 2002
Resolved 1 August 2002
Documentation › Markings/Placards
Issued 29 April 2002
Resolved
Freshen placard for upper deck capacity. LEGACY COMPONENT DESC: Capacity Marking
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2002
Resolved 1 August 2002
Navigation › Collision/Grounding Avoidance
Issued 29 April 2002
Resolved
Adjust port side running light by bending mounting bracket to correct angle. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2002
Resolved 1 August 2002
Personnel › Certificates/Documents/Licenses
Issued 29 April 2002
Resolved
Ensure vsl has currently licensed vessel operators, mst to provide documentation of reissued license. LEGACY COMPONENT DESC: License, Master
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2002
Resolved 1 August 2002
Unknown
Issued 9 May 2001
Resolved
DEMONSTRATE PROPER OPERATION OF PORT OUTDRIVE.
Condition: Unknown
Due 15 May 2001
Resolved 4 June 2001
Unknown
Issued 9 May 2001
Resolved
MAINTAIN COPY OF 46 CFR 166-199 (SUBCHAPTER T) ON BOARD VESSEL.
Condition: Unknown
Due 15 May 2001
Resolved 5 June 2001
Unknown
Issued 9 May 2001
Resolved
PERMANENTLY SEAL OPEN THROUGH HULL IN TRANSOM (FORMER EXHAUST DISCHARGE PORT).
Condition: Unknown
Due 15 May 2001
Resolved 4 June 2001
Unknown
Issued 9 May 2001
Resolved
PROVIDE A COMPLETE, CURRENT, APPROVED FIRST AID KIT.
Condition: Unknown
Due 15 May 2001
Resolved 5 June 2001
Unknown
Issued 9 May 2001
Resolved
DEMONSTRATE PROPER OPERATION OF FUEL GUAGE AT OPERATING STATION.
Condition: Unknown
Due 15 May 2001
Resolved 4 June 2001
Unknown
Issued 9 May 2001
Resolved
AFFIX HAZARD GUARDS IN WAY OF CRANKSHAFT AND ACCESSORY PULLIES, PORT AND STARBOARD MAIN PROP ENGINES.
Condition: Unknown
Due 7 June 2001
Resolved 5 June 2001
Unknown
Issued 9 May 2001
Resolved
SECURE SERVICE GENERATOR EXHAUST HOSE (ADD BRACKET).
Condition: Unknown
Due 15 May 2001
Resolved 4 June 2001
Unknown
Issued 9 May 2001
Resolved
DEMONSTRATE PROPER OPERATION OF AFT PUBLIC ADDRESS SYSTEM SPEAKER.
Condition: Unknown
Due 15 May 2001
Resolved 4 June 2001
Lifesaving
Issued 2 May 2000
Resolved
DOCUMENT CREW TRAINING AS PER 46CFR185.50 AND 46CFR185.524._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Electrical
Issued 2 May 2000
Resolved
PROVIDE A MEANS OF MEASURING FREQUENCY OF VESSEL DIESEL GENERATOR.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Engineering
Issued 2 May 2000
Resolved
REPLACE THE RAW WATER DISCHARGE HOSE ON THE DIESEL ENGINE GENSET. THE HOSE IS LOCATED FROM THE ENGINE TO THE MUFFLER.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Construction/Loadline
Issued 2 May 2000
Resolved
REPLACE CHECKED DIAPHAGM IN THE HAND BILGE PUMP.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Electrical
Issued 3 May 1999
Resolved
SECURE LOOSE WIRES LOCATED ON PORT MAIN DIESEL ENGINE AND TO PORT OIL PUMP.
Condition: Unknown
Due 10 May 1999
Resolved 12 May 1999
Engineering
Issued 3 May 1999
Resolved
SECURE FUEL OIL FILTER ON PORT MAIN ENGINE.
Condition: Unknown
Due 10 May 1999
Resolved 12 May 1999
Lifesaving
Issued 3 May 1999
Resolved
replace outdated battery in waterlight.
Condition: Unknown
Due 10 May 1999
Resolved 12 May 1999
Engineering
Issued 3 May 1999
Resolved
REPLACE EXHAUST HOSE ON SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 10 May 1999
Resolved 12 May 1999
Engineering
Issued 3 May 1999
Resolved
SECURE LOOSE GROUNDING WIRE ON STARBOARD FUEL TANK
Condition: Unknown
Due 10 May 1999
Resolved 12 May 1999
Lifesaving
Issued 3 May 1999
Resolved
update and post senior deckhand list in pilot house.
Condition: Unknown
Due 10 May 1999
Resolved 12 May 1999
Lifesaving
Issued 3 May 1999
Resolved
replace outdated orange smoke distress signals
Condition: Unknown
Due 10 May 1999
Resolved 12 May 1999
Electrical
Issued 19 May 1998
Resolved
REPLACE AIR INTAKE HOSE ON VESSEL'S DIESEL SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 19 June 1998
Resolved 10 July 1998
Electrical
Issued 19 May 1998
Resolved
REPLACE MISSING BOLTS TO SECURE THE FUEL PUMP TO DIESEL SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 19 June 1998
Resolved 10 July 1998
Electrical
Issued 19 May 1998
Resolved
PROPERLY SECURE WIRING AND CABLES IN ENGINE ROOM AND MACHINERY SPACES WITH METAL SUPPORTS EVERY 24 INCHES.
Condition: Unknown
Due 19 June 1998
Resolved 10 July 1998
Navigation
Issued 19 May 1998
Resolved
REPAIR UPPER DECK P. A. SPEAKERS.
Condition: Unknown
Due 19 June 1998
Resolved 10 July 1998
Engineering
Issued 19 May 1998
Resolved
SECURE GROUND WIRE ON PORT MAIN DIESEL ENGINE.
Condition: Unknown
Due 19 June 1998
Resolved 1 July 1998
Lifesaving
Issued 19 May 1998
Resolved
INSTALL 31.5 SQ INCHES (FOUR 2 X 4 " STRIPS) OF RETRO REFLECTIVE TAPE ON EACH SIDE OF THE LIFERINGS.
Condition: Unknown
Due 19 June 1998
Resolved 10 July 1998
Navigation
Issued 19 May 1998
Resolved
REPAIR FATHOMETER LOCATED IN PILOTHOUSE
Condition: Unknown
Due 19 June 1998
Resolved 10 July 1998
Navigation
Issued 19 May 1998
Resolved
REPAIR EXTINGUISHED COMPASS LIGHT IN PILOT HOUSE.
Condition: Unknown
Due 19 June 1998
Resolved 10 July 1998
Lifesaving
Issued 19 May 1998
Resolved
INVENTORY / UPDATE FIRST AID KIT.
Condition: Unknown
Due 19 June 1998
Resolved 2 July 1998
Accommodation/Occupational Safety
Issued 19 May 1998
Resolved
REPLACE WINDOWS IN MAIN CABIN INSURE THEY ARE SAFETY GLASS AS PER 46 CFR 177.1010.
Condition: Unknown
Due 2 June 1998
Resolved 2 July 1998
Electrical
Issued 19 May 1998
Resolved
REPAIR STARBOARD MAIN DIESEL ENGINE TACHOMETER LOCATED ON THE BRIDGE.
Condition: Unknown
Due 19 June 1998
Resolved 10 July 1998
Navigation
Issued 19 May 1998
Resolved
REPAIR RUDDER ANGLE INDICATOR IN PILOT HOUSE.
Condition: Unknown
Due 19 June 1998
Resolved 10 July 1998
Electrical
Issued 30 April 1996
Resolved
MAKE OPERABLE AND PROVE SATIFACTORY OPERATION OF THE 120 VOLT AC METER ON THE VESSEL'S AUX DIESEL GENERATOR SET.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Navigation
Issued 30 April 1996
Resolved
PROVE SATISFACTORY OPERATION OF VESSEL'S MAGNETIC COMPASS.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Accommodation/Occupational Safety
Issued 30 April 1996
Resolved
REPAIR BROKEN WINDOWS LOCATED IN WAY OF THE PILOT HOUSE AND THE MAIN SALON.THE NEW GLASS SHALL BE REPLACED IN KIND._x001C_
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Engineering
Issued 5 May 1994
Resolved
REPLACE THE CHECKED JACKET FUEL HOSE ON THE PORT AND STBD MAIN ENGINE AND REPLACE WITH USCG TYPE A1 FUEL HOSE. ALSO INSTALL USCG TYPE A1 FUEL HOSE ON THE SHIP SERVICE GENERATOR SUPPLY AND RETURN LINE.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Engineering
Issued 5 May 1994
Resolved
COMPLY WITH 46 CFR 182.20-45. MACHINERY SPACE SHALL BE FITTED WITH AN EXHAUST DUCT CONSTRUCTED OF FIRE PROOF MATERIAL. DUCT WORK SHALL EXTEND WITH-IN 6" OF ENGINE ROOM FLOOR. DUCT SHALL BE CONNECTED TO EITHER THE PORT OR STBD SUPPLY PLENUM.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Accommodation/Occupational Safety
Issued 5 May 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Construction/Loadline
Issued 4 May 1993
Resolved
INSTALL VESSELS NAME IN WAY OF THE PORT AND STBD BOW. LETTERS SHALL BE NO LESS THAN 4" HIGH.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Documentation
Issued 4 May 1993
Resolved
MARK UPPER PASSENGER DECK WITH MAXIMUM NUMBER OF PERSONS ALLOWED AS PER VESSELS STABILITY LETTER.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Lifesaving
Issued 4 May 1993
Resolved
ALL LIFEJACKETS STOWED IN THE CONCEALED OVERHEAD SHALL BE IDENTIFIED IN LETTERS NOT LESS THAN 1" HIGH, WITH TYPE (ADULT OR CHILDREN) AND QUANITY.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Electrical
Issued 4 May 1993
Resolved
INSTALL EMERGENCY DISCONNECT SWITCHES IN EACH UNGROUNDED SIDE OF ALL BATTERY SUPPLY LEADS. REF 46CFR183.05-10(f).
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Lifesaving
Issued 4 May 1993
Resolved
SUPPLY 6 CG APPROVED HAND SMOKE SIGNALS, TO BE ON BOARD VESSEL STORED IN A WATERTIGHT CONTAINER.
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Construction/Loadline
Issued 13 October 1992
Resolved
CROP AND INSERT TRIPPED FRAME LOCATED FRAME NO.4, STBD OF CENTER LINE.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Construction/Loadline
Issued 13 October 1992
Resolved
WELD FRAME SNIPE AT CENTER LINE LOCATED FRAME 4,5,7 AND 8. AREA MISSED DURING INITIAL CONSTRUCTION.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Accommodation/Occupational Safety
Issued 13 October 1992
Resolved
REPLACE HOSE AND CLAMP JOINTS IN WAY OF POTABLE WATER LINE RUNNING THROUGH COMPARTMENT NO. 3 AND 4 WITH METALIC PIPE SECTIONS.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Navigation
Issued 13 October 1992
Resolved
INSPECT HYDRAULIC HOSE FOR WEAR IN WAY OF CHAFFING ON STBD ENGINE OVERBOARDMANIFOLD, REPLACE HOSE IF WORN. INSTALL CHAFFING MATERIAL ON DIAMETER OF HOSE TO PREVENT RE-OCCURANCE OF WEAR.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Construction/Loadline
Issued 13 October 1992
Resolved
REMOVE NON-METALIC FLEX HOSE IN WAY OF DIESEL GENERATOR SEA SUCTION AND INSTALL METALIC SEA VALVE IN WAY OF HULL PENETRATION.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Engineering
Issued 13 October 1992
Resolved
REPLACE AND INSTALL NEW PROPELLERS ON THE PORT AND STBD ENGINES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Lifesaving
Issued 12 April 1988
Resolved
PROVIDE ONE ADDITIONAL ADULT PFD.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Lifesaving
Issued 12 April 1988
Resolved
LABLE STORAGE FOR CHILD PFD'S.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Electrical
Issued 12 April 1988
Resolved
SECURE BATTERY BOX IN PILOTHOUSE.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Fire Fighting
Issued 12 April 1988
Resolved
REPLACE THREE (3) B-1,FIRE EXTINGUISHERS WITH THREE (3) B-II'S.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988