Records from 2016 to 2025. Most recent: inspection, 25 August 2025.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 August 2025
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Observed batteries with wingnut connections on terminals.
46 CFR 183.350(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2025
Resolved 29 August 2025
Resolution: O/O submitted acceptable photos of battery terminal cables secured by permanent connectors.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection.. observed that the port aft cleat for mooring is cracked.
46 CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2025
Resolved 25 September 2025
Resolution: O/O Submitted photo of new cleat insatllation
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 August 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Observed 02 junction box covers are missing in the lazarette.
46 CFR 183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2025
Resolved 29 August 2025
Resolution: O/O submitted photos of juction boxes with proper covers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 August 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Observed that the bonding wire to the freshwater pump and fuel compartment was broken.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2025
Resolved 25 September 2025
Resolution: O/O sent photo pf new bonding wire attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 July 2024
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Main transverse watertight bulkhead as listed on stability letter found with non watertight penetrations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2024
Resolved 5 September 2024
Resolution: Received photos from vessel rep penetrations have been made watertight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 July 2024
Resolved
Each inlet or discharge pipe that penetrates the hull 6 inches above the waterline must have a means to prevent water from entering the vessel. Ball valve for freshwater supply found with broken handle located in lazarrete.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2024
Resolved 28 October 2024
Resolution: Received photo of newly installed valve, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 July 2024
Resolved
A hatch cover must have securing devices and be attached to the hatch frame to prevent its loss. Forward hatch missing securing mechanism.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2024
Resolved 9 October 2024
Resolution: Submitted photo evidence of replaced hatch, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Port generator raw water discharge hose found wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2024
Resolved 5 September 2024
Resolution: Vessel provided photo of replaced raw water hose. All Sat.
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 9 July 2024
Resolved
Overcurrent protection must be provided for each undergrounded conductor. Forward refrigerator installation found without dedicated circuit protection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2024
Resolved 5 September 2024
Resolution: Received a photo clearing def, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 July 2024
Resolved
The construction and arrangement of the vessel must allow safe operation giving consideration to provisions for a seaworthy hull. Damage discovered in the aft port corner deck edge compromising the exterior fiberglass sheathing. Repair prior to 2025 operating season.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 May 2025
Resolved 25 August 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties. Last fire drill conducted in CY 2023. Conducted satisfactory drill in presence of attending marine inspectors.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 July 2024
Resolution: Properly logged drill in presence of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect from electrical hazards, fire, and electric shock. All permanently installed electrical equipment shall have dedicated overcurrent protection and shall be appropriately mounted. equipment is to include but not limited to fans, air compressor, refers, etc.
46 CFR 183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 12 July 2023
Resolution: Extension cords removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2023
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable. Hydraulic steering hose was found dry rotted and needs replaced.
46 CFR 182.610(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 12 July 2023
Resolution: Hydraulic steering hose replaced.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 May 2023
Resolved
Vapor barriers must be provided in spaces where flammable and combustible liquids or vapors are present. All bulkhead penetrations in aft and fwd engine room need sealed to maintain vapor boundary.
46 CFR 177.405(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 15 June 2023
Resolution: Operator provided photograph of sealed engine room bulkhead penetrations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 May 2023
Resolved
Vesels constructed of wood must provide bilge high level alarms in all watertight compartments. FWD compartment visual indicator inoperable.
46 CFR 182.530
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 12 July 2023
Resolution: Visual indicator replaced, and operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2023
Resolved
Each container for life jackets must be marked with number and identification of items stowed not marked.
46 CFR 185.604(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 15 June 2023
Resolution: Operator provided photograph of proper labeling of life jacket stowage locations.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect the vessel from electrical hazards. Temporary battery charger installed. Submit installation plans for approval of new battery charger installation to satisfaction of OCMI.
46 CFR 183.200(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 10 July 2023
Resolution: Plan received and approved.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2023
Resolved
Electrical equipment must be installed to protect passengers from electrical hazards. Remove 02 unapproved power strips.
46 CFR 183.200(b)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 2 June 2023
Resolved 2 June 2023
Resolution: Unapproved power strips removed in the presence of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 May 2022
Resolved
Individual bilge suction lines must be provided with a check valve at some accessible point in the bilge line. E/R bilge sutcion line did not have a check valve.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 9 June 2022
Resolution: Vessel installed check valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 May 2022
Resolved
A bilge suction must be fitted with a suitable strainer having an area not less than three times the area of the bilge pipe. FWD storeroom bilge suction strainer was broken/missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 9 June 2022
Resolution: Vessel replaced strainer.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 May 2022
No resolution recorded
Each vessel must have permanent draft marks at each end of the vessel or have permanent loading marks. Vessel was missing the marks IAW 185.602. To be rectified by next scheduled or un-scheduled out of water inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 May 2022
Resolved
Owner, managing operator, or qualified servicing facility must conduct inspections and tests required by table 176.810(b) in addition to tests required by 46 CFR 147.60 and 147.65. If any equipment records have not been properly maintained a qualifying servicing facility may be required. Annual servicing has not been maintained. Owner shall have qualified servicing facility conduct required inspections, maintenance procedures, and hydrostatic pressure test and provide the servicing report to lead inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 9 June 2022
Resolution: Vessel had 3rd party inspection conducted on fixed CO2 system and provided satisfactory documentation.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 May 2022
Resolved
The minimum capacity of the power fire pumps shall be 50GPM at a pressure of not less than 60PSI at the pump outlet. Owner shall ensure 60PSI at the pump outlet. Pump gauge only registered 20PSI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 30 May 2023
Resolution: FIre pump replaced and test to >60 psi, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 May 2022
Resolved
The arrangement of a vessel must allow safe operation of the vessel in accordance with its COI. Several labels were missing on the vessel to include emergency fuel shut offs, fire extinguishers, escape hatch, and max crew capacity on second deck.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 9 June 2022
Resolution: Vessel ordered and installed all appropriate placards.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 7 September 2018
Resolved
A lighting fixture in an accommodation space, radio room, galley or similar interior space may comply with the following UL ratings 1570, 1571, 1572, 1573 or 1574 as long as the general marine requirements of UL 595 are satisfied. Current lighting on main deck overhead does not appear to meet these requirements, prove UL rating or replace lights with ones that meet requirements.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2022
Resolution: Deficiency corrected during last drydock.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 August 2018
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. 46 CFR 176.810(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2018
Resolution: Verified servicing of portable fire extinguishers.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 August 2018
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. 46 CFR 176.810(b)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2018
Resolution: Verified servicing of fixed CO2 system.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 2 August 2018
Resolved
Inspection standards. (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Inspection of the collision bulkhead revealed the bulkhead was wasted with holes allowing free communication between the forpeak and forward crew compartments. Crop and renew wasted bulkhead. Temporary repairs were made to the decayed bulkhead with plywood, 5200 sealant and west systems. Make permanent repairs to bulkhead prior to carrying passengers 46 CFR 176.802
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 August 2022
Resolution: Deficiency corrected during last drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 August 2018
Resolved
The owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including operation of the main propulsion machinery. Prove operation of propulsion machinery prior to operation. 46 CFR 176.804
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2018
Resolution: Witnessed proper operation of propulsion machinery.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 August 2018
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. All bilge high level alarms were not operational. Prove proper operation of all high level alarms prior to operation. 46 CFR 182.530
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2018
Resolution: Witnessed operation of all bilge high level alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2018
Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] used in a vital system must:(1) Be composed of ferrous materials except when: (i) Nonmetallic piping materials are permitted by §182.720; or (ii) Nonferrous metallic piping materials are permitted by §182.730 #3 compartment (Fuel Tanks) unable to take suction from compartment because valve on common manifold is inop not allowing the valve to open.
Remove nonmetallic bilge piping from manifold and replace with approved material as original or submit plans to the cognizant OCMI for approval. 46 CFR 182.700
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 August 2022
Resolution: Deficiency corrected during last drydock.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 4 December 2017
Resolved
Add signage for space protected by CO2 and space storing CO2. (46CFR185.612(g)(1)&(2)
Action required: 705 - Other - as specified
Due 17 January 2018
Resolved 16 January 2018
Resolution: CO2 warning signs added to bottle storage space and engine room.
Fire Fighting › Fire Pumps › Pressure
Issued 6 April 2017
Resolved
FIRE PUMP OUTLET SHALL BE FITTED WITH A PRESSURE GAUGE. PROVIDE GAUGE. 46 CFR 181.10-1(C)
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 26 April 2017
Resolution: Pressure gauge installed at pump outlet.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 April 2017
Resolved
PROVIDE SEPARATE STOWAGE FOR CHILD SIZE LIFE JACKETS, AWAY FROM ADULT LIFE JACKETS. 46 CFR 180.78(a)(5)
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 26 April 2017
Resolution: Stowage seperated for life jackets with dividers.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 April 2017
Resolved
M-PAKS (ALCOHOL SWABS) ARE EXPIRED. PROVIDE CURRENT M-PAKS ON BOARD. 46 CFR 16
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 26 April 2017
Resolution: New testing kits purcahsed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 April 2017
Resolved
REPAIR/REPLACE STERN LIGHT. LIGHT IS NOT VISIBLE. 33 CFR 83.22(a)(iii)
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 26 April 2017
Resolution: Stern light bulb replaced.
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 April 2017
Resolved
Prove radar is operable.(46 CFR 184.404) Do not cross demarcation line until radar is operable.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 2 June 2017
Resolution: Replaced with new radar and proved operation.
Construction/Loadline › Hull › Hull Plating
Issued 6 January 2017
Resolved
Issued 01 requirement to explore water weeping from beneath four rain drop size bulbles beneath hull paint in way of marked areas on the starboard chine.
Action required: 705 - Other - as specified
Resolved 11 January 2017
Resolution: Three of four marked areas were water trapped under layers of old paint, resolved with light sanding and painting. Fourth area required grinding down to good fiberglass, being allowed to dry out and built back up with fiber and resin coating to reseal.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 April 2016
Resolved
First aid kit is missing required items. Provide all items for first aid kit listed in 46 CFR 160.041-4(b).
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 14 April 2016
Resolution: New kit provided onboard
Lifesaving › Hand Flares › Quantity
Issued 4 April 2016
Resolved
Vessel does not have required amount of hand flares for route. Provide on board a total of 12 flares as listed in 46 CFR 180.68. Restrict route to Lakes, Bays and Sounds.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 5 April 2016
Documentation › Markings/Placards › Garbage Placard
Issued 4 April 2016
Resolved
MARPOL placard is missing. Provide on board and display for crew and passengers. 33 CFR 151.59
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 5 April 2016
Documentation › Markings/Placards › Lifejacket Placard
Issued 4 April 2016
Resolved
Placard with instructions for donning and use of life jackets is missing from 1st deck, provide and post. 46 CFR 185.516
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 5 April 2016
Engineering › Pressure Vessel › Relief Valve
Issued 4 April 2016
Resolved
Remove t-handle plug from pressure relief valve on hot water heater. 46 CFR 182.320
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 14 April 2016