MAURY USCG vessel records
← All vessels

LINDEN PRIDE

LINDEN PRIDE is a 2001 tank ship. The Coast Guard has recorded 4 inspections since 2016, most recently in January 2023, along with 2 deficiencies.

Records from 2016 to 2023. Most recent: inspection, 30 January 2023.

Built
2001
Last inspected
30 January 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 January 2023
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9206396
Flag
PANAMA
Maury page id
psix-23187

Documentation record

Tonnage as PSIX records it46021 - Convention (Subpart B), Gross Ton
13807 - Convention (Subpart B), Net Ton
49999 - Dead Weight, Metric Ton
68071 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

4 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

30 January 2023 Administrative Inspection · PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7626821
26 January 2023 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7627422
13 October 2017 ISPS III Exam · Deficiency Check · Ballast Water Examination · COC-GAS Annual · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6284705
22 November 2016 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6034693

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 January 2023 Resolved
On Ship Carrying flamable or toxic products or both, a water spray system for cooling , fire prevention should be installed. On cargo tank top #1 was found to have inadequate coverage of deck water spray. Vessel crew able to correct/clear DWS. Coverage tank top #1 adequate. Def cleared.
Action required: 10 - Deficiency Rectified
Due 30 January 2023
Resolved 30 January 2023
Resolution: Vessel crew able to correct/clear DWS. Coverage tank top #1 adequate. Def cleared.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 13 October 2017 Resolved
0725- SHIPS CARRYING FLAMMABLE OR TOXIC PRODUCTS, A WATERSPRAY SYSTEM FOR COOLING, FIRE PREVENTION, AND CREW PROTECTION SHOULD BE INSTALLED TO COVER CARGO LIQUID AND VAPOUR DISCHARGE AND LOADING MANIFOLDS AND BOUNDARIES OF SUPERSTRUCTURES AND CAGRO COMPRESSOR ROOMS. DURING TEST OF DECK WATERSPRAY FOUND NUMEROUS NOZZLES NOT WORKING IN THE FOLLOWING LOCATIONS. 03 OVER TANK ONE, 04 OVER PORT MANIFOLD, 06 OVER STBD MANIFOLD, AND 16 OVER CARGO COMPRESSOR AND MOTOR ROOM.- 74 SOLAS (CONS 14) VII/13.1, IGC CODE (93) CH. 11.3.1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2017
Resolution: SEC HOU-GAL PSC received a class report from NKK satisfying the requirement.

Ownership record