Inspection history · 59
3 February 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8074000
14 February 2024
ACP Drydock Oversight · Permit to Proceed · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7865705
14 January 2024
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7849302
13 January 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7849312
9 January 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847139
8 January 2024
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847293
21 October 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7812622
15 October 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7812311
15 September 2023
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7791949
1 September 2023
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7789066
7 August 2023
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7762677
7 July 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7737889
2 May 2023
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7678946
10 February 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7635169
27 December 2022
Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7613399
6 June 2022
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7470927
18 May 2022
Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7454065
11 February 2022
Annual Inspection · ACP Annual Oversight · ACP Drydock Oversight · ACP Additional Oversight – Risk Assessment
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7394791
10 January 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7378095
31 October 2021
Administrative Inspection
Administrative · Activities Europe · Activity 7342946
31 October 2021
Type not recorded
No type recorded · Activities Europe · Activity 7359186
15 September 2021
Administrative Inspection
Administrative · Activities Europe · Activity 7313380
2 September 2021
Administrative Inspection
Administrative · Activities Europe · Activity 7307262
2 September 2021
Type not recorded
No type recorded · Activities Europe · Activity 7308958
23 August 2021
Type not recorded
No type recorded · Activities Europe · Activity 7300188
27 May 2021
Deficiency Check · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7207569
14 May 2021
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7195768
28 June 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6992379
24 June 2020
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6985611
10 March 2020
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6924329
10 March 2020
Administrative Inspection · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6924344
12 February 2020
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6907522
30 November 2019
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6871641
13 November 2019
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6854463
23 August 2019
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6792185
2 August 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6770581
23 July 2019
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6759828
23 July 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6760446
18 July 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6754654
26 June 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6729033
7 June 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6706369
6 June 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6710719
29 May 2019
ACP COI Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6681352
7 February 2019
In-Service Inspection
Physical examination · Activities Europe · Activity 6614400
31 January 2019
ACP Drydock Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6618194
10 January 2019
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6608232
19 December 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6600058
29 November 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6589372
25 November 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6586184
29 May 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6427816
15 May 2018
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6408830
4 January 2018
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6437526
24 December 2017
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6433447
21 December 2017
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6385516
14 August 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6247282
19 May 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6152411
2 May 2017
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6137531
30 November 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6050157
23 May 2016
ACP COI Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5880837
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 January 2024
Resolved
Vessels reported a MDG failure resulting in a loss of propulsion, and steering.
Vessel reported they will be transiting back to SD. Vessel shall have the appropriate tug assist for the vessels entry into SD.
Vessel replaced UPS and no.2 MG Set Circuit Breaker. Numerous propulsion trips occurred leading up to power failure. Conduct sea trial with tech rep present prior to sailing to next port. Provide CG and RO with tech report upon completion.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2024
Resolution: Vessels reported a MDG failure resulting in a loss of propulsion, and steering.
Vessel reported they will be transiting back to SD. Vessel shall have the appropriate tug assist for the vessels entry into SD.
Vessel replaced UPS and no.2 MG Set Circ
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 January 2024
Resolved
Vessels reported a main propulsion computer failure resulting in a loss of propuslsion and the automation
failing to operate resulting in the vessel coming back on local control.
Vessel reported they will be transiting back to SD. Vessel shall have the appropriate tug assist for the vessels entry into SD.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 May 2023
Resolved
The ship condition of the ship and its equipment shall be maintained to conform with the provision of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Remote closure of No 7 fuel valve failed due to ruptured hydraulic tubing. Other remote closuring fuel valves were not available for testing. To be cleared by CG and Class.
74 SOLAS (2020) 1/11
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2023
Resolved 5 May 2023
Resolution: Satisfactorily demonstrated to ABS and CG.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 May 2023
Resolved
The ship condition of the ship and its equipment shall be maintained to conform with the provision of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Open/close electric switches for steering room WTD 4-47-4, were sticking in the open position, which prevent the door from remote closure. To be cleared by CG and Class.
74 SOLAS (2020) 1/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2023
Resolved 5 May 2023
Resolution: Satisfactorily demonstrated to ABS and CG.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 2 May 2023
Resolved
After any survey of ship of ship under regulation 7,8,9, or 10 has been completed, no changes shall be made in structural arrangements, machinery, equipment and other items covered by the survey, without sanction of the administration. Emergency generator fail to complete 3 consecutive start attempts on stored hydraulic energy capacity as required by ABS rules. To be cleared by CG and Class.
74 SOLAS (2020) 1/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 5 May 2023
Resolution: Satisfactorily demonstrated to ABS and CG.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 2 May 2023
Resolved
The ship condition of the ship and its equipment shall be maintained to conform with the provision of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. When starting the Emergency generator, using the secondary B bank of hydraulic accumulator, the reservoir tank is pressurized, ejecting hydraulic fluid from the top of reservoir. To be cleared by CG and Class.
74 SOLAS (2020) 1/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 5 May 2023
Resolution: Satisfactorily demonstrated to ABS and CG.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 May 2023
Resolved
Each lifeboat shall be launched, and maneuvered in the water by its assigned operating crew, at least every three months during an abandon ship drill. Conduct lowering, maneuvering and recovery of a lifeboat to the satisfaction of the attending CG Marine Inspector.
74 SOLAS (2020) III/19.3.4.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 5 May 2023
Resolution: Satisfactorily demonstrated to CG.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 May 2023
Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order to ensure their required performance. Identified several fire doors on 01 deck and 02 deck leading to the stairway not latching the fire division as designed.
SOLAS 74 (2020 Con. Ed.) II-2/14.2.1.1.1
Action required: 10 - Deficiency Rectified
Due 3 May 2023
Resolved 3 May 2023
Resolution: Corrected to the satisfaction of the CG.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 May 2023
Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols IAW the recommendations of the Organization indicating the devices stowed in that location for that purpose. Found numerous lifesaving appliances throughout the vessel missing placarding.
SOLAS 74 (2020 Con. Ed.) III/20.10
Action required: 10 - Deficiency Rectified
Due 3 May 2023
Resolved 3 May 2023
Resolution: Corrected to the satisfaction of the CG.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 May 2023
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. #2 Lifeboat davit brake cannot be released using the remote cable from inside of the lifeboat. The weight on the cable prevents full travel by striking the canopy.
74 SOLAS(2020)III/20.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2023
Resolved 17 May 2023
Resolution: Witnessed correct operation by ABS.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 6 June 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel crew identified pinhole leak within the #3 ballast tank bulkhead. 74SOLAS(20)I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 8 June 2022
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2022
Resolved
The condition of the ship and its equipment shall be maintained to remain fit to proceed to sea without danger to the ship or persons on board. Received report from vessel of a reduction in steering. STBD steering unit causes rudder to drift to port in normal operations. Vessel is required to man steering while operating within the COTP Zone - Sector Virginia. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 14 January 2022
Resolution: ABS accepted deficiency as a condition of Class and tracked repair of vessel steering casualty through to completion.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 18 May 2021
Resolved
If a ship has a watch or work station located remotely from the place where immersion suits are normally stowed, additional immersion suits shall be provideda at these locations. ECR was missing all of its required immersion suits. 74 SOLAS (14) III/32.3.3
Action required: 10 - Deficiency Rectified
Resolved 18 May 2021
Resolution: Crew provided the required immersion suits and stowed them in their approriate locker.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 May 2021
Resolved
Structural fire protection and penetrations in fire resisting divisions shall be kept in good working order. Forward bow thruster compartment has MCT in the boundary missing fire stop and incorrectly installed fire stop.
74 SOLAS (20) II-2/14.2.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2021
Resolution: ABS informed MI that MCT has been permanently repaired.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 May 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Rope locker compartment MCT missing fire stop.
74 SOLAS (20) II-2/14.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2021
Resolution: ABS informed MI that MCT has been permanently repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. #5 MDG halon cylinders hydro test/ 5 year inspection is out of date.
74 SOLAS (20) I/11
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by Class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 14 May 2021
Resolved
Before the ship leaves port and at all times during the
voyage, all life-saving appliances shall be in working
order and ready for immediate use. Properly outfit
lifeboat #1. Missing or inoperable searchlight, rainwater collector and seasick medicine.
74 SOLAS (20) III/20.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 14 May 2021
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Properly outfit lifeboat #2. Found inoperable searchlight and missing rainwater collector.
74 SOLAS (20) III/20.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 14 May 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Broken lighting globes in way of 2-27-0 conference room, starboard side passageway.
74 SOLAS (20) I/11
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 14 May 2021
Resolved
Each lifeboat shall be launched and maneuvered in the water by it's assigned operating crew, at least once every three months. Lifeboat #1 was not maneuvered since June 2020. Launch and maneuver Lifeboat #1 as soon as practicable upon getting underway.
74 SOLAS (20) III/19.3.4.3
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 27 May 2021
Resolution: Vessel launched and recovered Lifeboat #1.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2021
Resolved
Every crew member shall participate in at least one fire drill every month. There was no fire drill recorded in September of 2020.
74 SOLAS (20) III/19.3
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 14 May 2021
Resolution: Conducted a fire drill.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 May 2021
Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Fire door 2-43-3 missing fire hose door closure.
74 SOLAS (20) II-2/14.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Emergency diesel generator has accumulators temporarily removed and cannot provide six starts.
74 SOLAS (20) I/11
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 May 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Forward bow thruster compartment has wasted sea chest vent piping and temporary repair patch installed on a bilge/ballast line.
74 SOLAS (20) I/11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 May 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port side overboard piping in rope locker compartment is wasted.
74 SOLAS (20) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 May 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. MCC EOT is misaligned.
74 SOLAS (20) I/11
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: EOT aligned
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 May 2021
Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Investigate structural fire protection for ventilation dampers with inspection ports installed in dry stores and officer mess to determine required boundary.
74 SOLAS (20) II-2/14.2.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Proper covers put in place.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 14 May 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. #1 and #2 steering pumps did not have audible power failure alarms.
74 SOLAS (20) I/11
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2021
Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Fire control panel displayed Rope Store Room #3 4-19-0 fault that would not clear.
74 SOLAS (20) II-2/14.2.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 May 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Power ventilation for paint locker was not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2020
Resolved
On or about 10MAR2020, while underway vessel suffered a casualty to its starboard main propulsion engine. It was repored that one of the blowers failed and parts have been ordered to arrive in Guam. Prior to departure from COTP Zone Guam, affect repairs to the satisfaction of the attending Class Surveyor and submit a copy of Class' report to USCG Sector Guam.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2020
Resolved
Measures shall be taken to the satisfaction of administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspection and routine tests to ensure continuous reliable operations. It was reported vessel experience a temporary loss of power due to a power management issue. Prove proper operation of power management system to the satisfaction of RO. SOLAS 74 a (2014 Cons)
II-1/46.2 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2020
Resolution: Received class report attesting to proper operation of power management system.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 November 2019
Resolved
Port steering gear experienced a momentary loss of steering in the control unit. Properly locate failure, make repairs and conduct testing to the satisfaction of attending classification society. SOLAS (74 CONS) 81 AMEND II-1/29.5.1
Action required: 15 - Rectify deficiencies by next port
Resolved 10 December 2019
Resolution: Referred to ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported loss of propulsion while at sea. Vessel required to have escort tug from sea buoy to mooring. Vessel shall use 2 tugs with a aggregate total horsepower of 5,000 or 50 ton bollard pull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2019
Resolved 27 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Determine cause of loss of propulsion and provide class report attesting to repairs and condition.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 27 July 2019
Resolution: ABS Report # NN3705633
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2019
Resolved
SINGLE NON-CONCURRENT FAILURES IN CONTROL, ALARM OR INSTRUMENTATION SYSTEMS AND LOGICAL CONSEQUENCES MUST NOT PREVENT SUSTAINED OR RESTORED OPERATION OF ANY VITAL SYSTEM. ALL 6 SCR(S) BREAKERS FOR DIESEL ELECTRIC PROPULSION TRIPPED SIMULTANEOUSLY, RESULTED IN LOSS OF PROPULSION. CAUSE BELIEVED TO BE CABINET DOOR SWICH SAFETU CIRCUIT.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 23 July 2019
Resolved 27 July 2019
Resolution: ABS Report #NN3705633
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 June 2019
Resolved
74 SOLAS III/ 9(a)
All motor lifeboats shall be equipped with a compression ingnition engine and kept as so to be at all times ready for immediate use. Vessel reported port lifeboat engine is inoperative and requires replacement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2019
Resolution: ABS attended vessel to clear def and verify port lifeboat operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 May 2019
Resolved
Means of identifying the ship to which the lifeboat belongs and the number of the lifeboat shall be marked in such a way that they are visible from above. Both lifeboats are missing their numbers. 74 SOLAS (14) III/31.1.1.1, LSA IV/4.4.9.3
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2019
Resolution: ABS Report # NN3685692
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 29 May 2019
Resolved
Each line throwing appliance must also have an auxiliary line that has a breaking strength of 9000 lbs., is of a dark color or certified to be UV resistant, and is at least 1500 ft. long. Messenger line provided does not appear to meet the criteria and ship was unable to provide specifications. 46 CFR 199.170(c), U.S. Supplement Section II-12
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2019
Resolution: ABS Report # NN3685692
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019
Resolved
Equipment not intended to become live should be adequately protected. Dead end wire found unsecured.
74 SOLAS Unamended II-1/27
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Corrected on the spot. Ships crew removed dead end wire.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 29 May 2019
Resolved
Equipment should be maintained in the condition it was surveyed. Found household fan installed to the backside of the Modine heater in the EDG space.
74 SOLAS I/11
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Corrected on the spot. Ships crew removed the household fan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2019
Resolved
Equipment should be maintained in the condition it was surveyed. Found port steering gear hydraulic relief valve missing copper crush ring and leaking hydraulic oil.
74 SOLAS I/11
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Corrected on the spot. Ships crew installed missing copper crush ring and tested in the presence of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2019
Resolved
Every lifebuoy intended to operate the quick-release arrangement provided for the self-activated smoke signals and self-igniting lights, shall have a mass of not less than 4 kg. The port bridge wing ring lifebuoy had a mass of 2.5 kg.
74 SOLAS (14) III/1.3, LSA II/2.1.1.7
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel was able to provide an additional ring lifebuoy of the correct size, 4 kg.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2019
Resolved
Lifebuoy self-activating smoke signals shall be provided with a quick release arrangement that will automatically release and activate the signal and associated self-igniting light connected to the ring lifebuoy. The port bridge wing self-activating smoke signal's lanyard was too short and not in accordance with the manufacturer's specifications.
74 SOLAS (14) III/1.3, LSA II/2.1.3.6
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew replaced the lanyard with one of the correct length.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 May 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship will remain fit to proceed to sea with out danger to the ship or persons on board. Vessel had expired pyro stowed alongside the good pyro in the bridge pyro locker. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew removed the pyro to a different location for training purposes.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 29 May 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship will remain fit to proceed to sea with out danger to the ship or persons on board. One lifeboat radio battery was found unsealed. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew was able to provide an additional sealed lifeboat battery.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 29 May 2019
Resolved
Posters or signs that illustrate the purpose of controls and the procedures for operating the appliance shall be provided on or in the vicinity of survival craft and their launching controls. Port and starboard lifeboat instructions were not posted in the vicinity of the lifeboat launching controls.
74 SOLAS (14) III/9.2.1
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew repositioned the lifeboat launching instructions to the control stations for both port and starboard lifeboats.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 May 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship will remain fit to proceed to sea with out danger to the ship or persons on board. One starboard side liferaft had a hydrostatic release unit that had expired. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew was able to provide an additional HRU that was not expired for the staboard liferaft.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 May 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship will remain fit to proceed to sea with out danger to the ship or persons on board. Vessel had compressed gas cylinders stowed that were outside of their hydrostatic test dates. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew removed from service the compressed gas cylinders with expired hydrostatic test dates.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 May 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship will remain fit to proceed to sea with out danger to the ship or persons on board. Port waste oil tank vent was missing its flame screen. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew installed new flame screen on gooseneck vent.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 15 May 2018
Resolved
All lifesaving equipment must be ready for immediate use. Found numerous food rations on port lifeboat had lost vacuum seal, which voids the expiration date. Renew with required amount for the capacity of the lifeboat.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2018
Resolved 29 November 2018
Resolution: ABS Report NN3499306-A
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 May 2018
Resolved
Stairtower self-closing fire doors 1-35 1/2-1 and 1-35 1/2-2do not fully close and latch. Repair/adjust doors for positive closure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 29 November 2018
Resolution: ABS Report NN3499306
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 15 May 2018
Resolved
One battery, for the three two-way portable lifeboat hand held radios, had a broken tamper proof seal. Renew battery with sealed unused battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 29 November 2018
Resolution: ABS Report NN3504537-B
Lifesaving › Launching Appliances › Davit
Issued 3 May 2017
Resolved
Rescue boat davit proof of approval is missing. Provide proof of USCG approval to the CG Marine Inspector
Due 2 June 2017
Resolved 19 May 2017
Lifesaving › Rescue Boat › Markings
Issued 3 May 2017
Resolved
Rescue boat approval is missing. Provide proof of USCG approval to the CG Marine Inspector.
Due 2 June 2017
Resolved 19 May 2017
Lifesaving › Launching Appliances › Release Mechanism
Issued 3 May 2017
Resolved
Demonstrate ability to launch rescue boat in 5 kts headway to the CG Marine Inspector.
Due 2 June 2017
Resolved 19 May 2017