USNS ZEUS is a 1984 industrial vessel. The Coast Guard has recorded 182 inspections since 1985, most recently in February 2025, along with 251 deficiencies and 23 casualty investigations between 2008 and 2024.

Records from 1985 to 2025. Most recent: inspection, 3 February 2025.

Built
1984
Last inspected
3 February 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7932408 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
231983
Flag
UNITED STATES
—
Maury page id
psix-231983

Inspections, by type

…with no type recorded53
Years with a record 40 calendar years (1985–2025)
The 182 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it6320 - Regulatory (Subpart C or D), Net Ton
15929 - Convention (Subpart B), Gross Ton
6963 - Dead Weight, Ton
12400 - Displacement, Ton
4778 - Convention (Subpart B), Net Ton
14934 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 182

3 February 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8074000
14 February 2024 ACP Drydock Oversight · Permit to Proceed · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7865705
14 January 2024 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7849302
13 January 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7849312
9 January 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847139
8 January 2024 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847293
21 October 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7812622
15 October 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7812311
15 September 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7791949
1 September 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7789066
7 August 2023 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7762677
7 July 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7737889
2 May 2023 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7678946
10 February 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7635169
27 December 2022 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7613399
6 June 2022 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7470927
18 May 2022 Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7454065
11 February 2022 Annual Inspection · ACP Annual Oversight · ACP Drydock Oversight · ACP Additional Oversight – Risk Assessment
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7394791
10 January 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7378095
31 October 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7342946
31 October 2021 Type not recorded
No type recorded · Activities Europe · Activity 7359186
15 September 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7313380
2 September 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7307262
2 September 2021 Type not recorded
No type recorded · Activities Europe · Activity 7308958
23 August 2021 Type not recorded
No type recorded · Activities Europe · Activity 7300188
27 May 2021 Deficiency Check · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7207569
14 May 2021 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7195768
28 June 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6992379
24 June 2020 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6985611
10 March 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6924329
10 March 2020 Administrative Inspection · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6924344
12 February 2020 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6907522
30 November 2019 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6871641
13 November 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6854463
23 August 2019 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6792185
2 August 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6770581
23 July 2019 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6759828
23 July 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6760446
18 July 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6754654
26 June 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6729033
7 June 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6706369
6 June 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6710719
29 May 2019 ACP COI Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6681352
7 February 2019 In-Service Inspection
Physical examination · Activities Europe · Activity 6614400
31 January 2019 ACP Drydock Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6618194
10 January 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6608232
19 December 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6600058
29 November 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6589372
25 November 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6586184
29 May 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6427816
15 May 2018 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6408830
4 January 2018 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6437526
24 December 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6433447
21 December 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6385516
14 August 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6247282
19 May 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6152411
2 May 2017 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6137531
30 November 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6050157
23 May 2016 ACP COI Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5880837
26 August 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5226715
30 October 2014 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5015573
14 October 2014 Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5008365
7 October 2014 Type not recorded
No type recorded · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5011391
29 May 2014 In-Service Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4908674
11 March 2014 Deficiency Check · Administrative Inspection · Special
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4813893
21 May 2012 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4320235
1 January 2012 Deficiency Check · Annual Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4248902
22 December 2011 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4253139
18 February 2011 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3960614
19 January 2011 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3939043
5 November 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3886886
2 November 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3883321
15 March 2010 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3727761
17 March 2009 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3434501
20 February 2009 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3434281
13 February 2009 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3400805
31 January 2009 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3554175
25 November 2008 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3400792
15 August 2008 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3299181
25 February 2008 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3153312
12 February 2008 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3136171
8 February 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3144344
11 October 2007 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3077655
18 September 2007 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3060857
20 June 2007 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2968155
14 May 2007 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2929833
11 October 2006 Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2802775
25 January 2006 MARPOL Annex I Examination · Security Plan Review - VSP · Annual Inspection · MARPOL Annex V Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2569780
1 June 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2375593
16 May 2005 Internal Structural Exam · Ballast Water Examination · Annual Inspection · MTSA Verification · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2359454
9 December 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2256931
24 June 2004 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2109314
20 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104915
2 March 2004 In-Service Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2016332
17 February 2004 COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2007180
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1997544
19 December 2003 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1966811
28 October 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1937743
27 August 2003 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1889032
14 August 2003 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1876110
18 June 2003 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1820489
3 June 2003 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1808595
24 May 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1803674
9 May 2003 Periodic Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1790090
28 March 2003 Internal Structural Exam · Damage Survey · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1761935
28 March 2003 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1766878
7 September 2002 Type not recorded
No type recorded · Activities Europe · Activity 1695852
6 February 2002 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1484354
27 June 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1054579
24 April 2001 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1389376
20 April 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 82470
10 April 2001 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1470022
31 March 2001 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1382073
10 March 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1049176
29 February 2000 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1472163
11 January 2000 Permit to Proceed
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 813770
29 March 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 28853
11 March 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1111481
24 February 1999 Re-Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1452484
29 October 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 804326
15 September 1998 Type not recorded
No type recorded · Activities Europe · Activity 114506
16 January 1998 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1109928
5 January 1998 Deficiency Check · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1390678
3 September 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1400628
2 July 1997 Re-Inspection · Hull Examination · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1443895
7 March 1996 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 885212
25 February 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1392396
12 January 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1183434
23 December 1994 Hull Examination · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1448610
8 August 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 868606
14 January 1994 Deficiency Check · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1422305
15 December 1993 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1162912
24 September 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 98986
17 January 1993 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1133159
6 January 1993 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1135715
23 April 1992 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1267777
18 November 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 962391
3 November 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 936557
31 July 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 940944
2 July 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1353187
10 April 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1235727
24 December 1990 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 925052
26 July 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 902401
11 July 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 932960
10 May 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 924946
2 May 1990 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 928438
22 March 1990 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1213824
10 February 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1235606
9 February 1990 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 909140
1 November 1989 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1230523
21 August 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 889305
6 February 1989 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1345240
13 January 1989 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1345966
18 July 1988 Deficiency Check · Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1340261
12 July 1988 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 896450
31 May 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1204180
23 February 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1336980
11 February 1988 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1019708
6 February 1988 Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1299660
30 July 1987 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1339151
17 July 1987 Damage Survey
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1020484
8 January 1987 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1004133
5 December 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1022212
9 October 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1315675
22 August 1986 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1295806
9 August 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1315674
3 July 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 998810
28 March 1986 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1309138
21 February 1986 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 995506
1 February 1986 Credit Drydock · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1294715
28 January 1986 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1011873
30 June 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1292349
28 June 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 983064
26 June 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 983067
20 June 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1292350
23 May 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 978327
21 May 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 983242
30 April 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 979564
29 April 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 981142
29 April 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1290612
27 March 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1287473
7 January 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 497583

Deficiency record · 251

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 January 2024 Resolved
Vessels reported a MDG failure resulting in a loss of propulsion, and steering. Vessel reported they will be transiting back to SD. Vessel shall have the appropriate tug assist for the vessels entry into SD. Vessel replaced UPS and no.2 MG Set Circuit Breaker. Numerous propulsion trips occurred leading up to power failure. Conduct sea trial with tech rep present prior to sailing to next port. Provide CG and RO with tech report upon completion.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2024
Resolution: Vessels reported a MDG failure resulting in a loss of propulsion, and steering. Vessel reported they will be transiting back to SD. Vessel shall have the appropriate tug assist for the vessels entry into SD. Vessel replaced UPS and no.2 MG Set Circ
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 January 2024 Resolved
Vessels reported a main propulsion computer failure resulting in a loss of propuslsion and the automation failing to operate resulting in the vessel coming back on local control. Vessel reported they will be transiting back to SD. Vessel shall have the appropriate tug assist for the vessels entry into SD.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 May 2023 Resolved
The ship condition of the ship and its equipment shall be maintained to conform with the provision of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Remote closure of No 7 fuel valve failed due to ruptured hydraulic tubing. Other remote closuring fuel valves were not available for testing. To be cleared by CG and Class. 74 SOLAS (2020) 1/11
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2023
Resolved 5 May 2023
Resolution: Satisfactorily demonstrated to ABS and CG.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 May 2023 Resolved
The ship condition of the ship and its equipment shall be maintained to conform with the provision of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Open/close electric switches for steering room WTD 4-47-4, were sticking in the open position, which prevent the door from remote closure. To be cleared by CG and Class. 74 SOLAS (2020) 1/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2023
Resolved 5 May 2023
Resolution: Satisfactorily demonstrated to ABS and CG.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 2 May 2023 Resolved
After any survey of ship of ship under regulation 7,8,9, or 10 has been completed, no changes shall be made in structural arrangements, machinery, equipment and other items covered by the survey, without sanction of the administration. Emergency generator fail to complete 3 consecutive start attempts on stored hydraulic energy capacity as required by ABS rules. To be cleared by CG and Class. 74 SOLAS (2020) 1/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 5 May 2023
Resolution: Satisfactorily demonstrated to ABS and CG.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 2 May 2023 Resolved
The ship condition of the ship and its equipment shall be maintained to conform with the provision of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. When starting the Emergency generator, using the secondary B bank of hydraulic accumulator, the reservoir tank is pressurized, ejecting hydraulic fluid from the top of reservoir. To be cleared by CG and Class. 74 SOLAS (2020) 1/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 5 May 2023
Resolution: Satisfactorily demonstrated to ABS and CG.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 May 2023 Resolved
Each lifeboat shall be launched, and maneuvered in the water by its assigned operating crew, at least every three months during an abandon ship drill. Conduct lowering, maneuvering and recovery of a lifeboat to the satisfaction of the attending CG Marine Inspector. 74 SOLAS (2020) III/19.3.4.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 5 May 2023
Resolution: Satisfactorily demonstrated to CG.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 May 2023 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order to ensure their required performance. Identified several fire doors on 01 deck and 02 deck leading to the stairway not latching the fire division as designed. SOLAS 74 (2020 Con. Ed.) II-2/14.2.1.1.1
Action required: 10 - Deficiency Rectified
Due 3 May 2023
Resolved 3 May 2023
Resolution: Corrected to the satisfaction of the CG.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 May 2023 Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols IAW the recommendations of the Organization indicating the devices stowed in that location for that purpose. Found numerous lifesaving appliances throughout the vessel missing placarding. SOLAS 74 (2020 Con. Ed.) III/20.10
Action required: 10 - Deficiency Rectified
Due 3 May 2023
Resolved 3 May 2023
Resolution: Corrected to the satisfaction of the CG.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 May 2023 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. #2 Lifeboat davit brake cannot be released using the remote cable from inside of the lifeboat. The weight on the cable prevents full travel by striking the canopy. 74 SOLAS(2020)III/20.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2023
Resolved 17 May 2023
Resolution: Witnessed correct operation by ABS.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 6 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel crew identified pinhole leak within the #3 ballast tank bulkhead. 74SOLAS(20)I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 8 June 2022
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to remain fit to proceed to sea without danger to the ship or persons on board. Received report from vessel of a reduction in steering. STBD steering unit causes rudder to drift to port in normal operations. Vessel is required to man steering while operating within the COTP Zone - Sector Virginia. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 14 January 2022
Resolution: ABS accepted deficiency as a condition of Class and tracked repair of vessel steering casualty through to completion.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 18 May 2021 Resolved
If a ship has a watch or work station located remotely from the place where immersion suits are normally stowed, additional immersion suits shall be provideda at these locations. ECR was missing all of its required immersion suits. 74 SOLAS (14) III/32.3.3
Action required: 10 - Deficiency Rectified
Resolved 18 May 2021
Resolution: Crew provided the required immersion suits and stowed them in their approriate locker.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 May 2021 Resolved
Structural fire protection and penetrations in fire resisting divisions shall be kept in good working order. Forward bow thruster compartment has MCT in the boundary missing fire stop and incorrectly installed fire stop. 74 SOLAS (20) II-2/14.2.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2021
Resolution: ABS informed MI that MCT has been permanently repaired.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 May 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Rope locker compartment MCT missing fire stop. 74 SOLAS (20) II-2/14.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2021
Resolution: ABS informed MI that MCT has been permanently repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. #5 MDG halon cylinders hydro test/ 5 year inspection is out of date. 74 SOLAS (20) I/11
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by Class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 14 May 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Properly outfit lifeboat #1. Missing or inoperable searchlight, rainwater collector and seasick medicine. 74 SOLAS (20) III/20.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 14 May 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Properly outfit lifeboat #2. Found inoperable searchlight and missing rainwater collector. 74 SOLAS (20) III/20.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 14 May 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Broken lighting globes in way of 2-27-0 conference room, starboard side passageway. 74 SOLAS (20) I/11
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 14 May 2021 Resolved
Each lifeboat shall be launched and maneuvered in the water by it's assigned operating crew, at least once every three months. Lifeboat #1 was not maneuvered since June 2020. Launch and maneuver Lifeboat #1 as soon as practicable upon getting underway. 74 SOLAS (20) III/19.3.4.3
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 27 May 2021
Resolution: Vessel launched and recovered Lifeboat #1.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2021 Resolved
Every crew member shall participate in at least one fire drill every month. There was no fire drill recorded in September of 2020. 74 SOLAS (20) III/19.3
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 14 May 2021
Resolution: Conducted a fire drill.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 May 2021 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Fire door 2-43-3 missing fire hose door closure. 74 SOLAS (20) II-2/14.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Emergency diesel generator has accumulators temporarily removed and cannot provide six starts. 74 SOLAS (20) I/11
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 May 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Forward bow thruster compartment has wasted sea chest vent piping and temporary repair patch installed on a bilge/ballast line. 74 SOLAS (20) I/11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 May 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port side overboard piping in rope locker compartment is wasted. 74 SOLAS (20) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 May 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. MCC EOT is misaligned. 74 SOLAS (20) I/11
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: EOT aligned
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 May 2021 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Investigate structural fire protection for ventilation dampers with inspection ports installed in dry stores and officer mess to determine required boundary. 74 SOLAS (20) II-2/14.2.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Proper covers put in place.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 14 May 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. #1 and #2 steering pumps did not have audible power failure alarms. 74 SOLAS (20) I/11
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2021 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Fire control panel displayed Rope Store Room #3 4-19-0 fault that would not clear. 74 SOLAS (20) II-2/14.2.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 May 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Power ventilation for paint locker was not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Accepted by class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2020 Resolved
On or about 10MAR2020, while underway vessel suffered a casualty to its starboard main propulsion engine. It was repored that one of the blowers failed and parts have been ordered to arrive in Guam. Prior to departure from COTP Zone Guam, affect repairs to the satisfaction of the attending Class Surveyor and submit a copy of Class' report to USCG Sector Guam.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2020 Resolved
Measures shall be taken to the satisfaction of administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspection and routine tests to ensure continuous reliable operations. It was reported vessel experience a temporary loss of power due to a power management issue. Prove proper operation of power management system to the satisfaction of RO. SOLAS 74 a (2014 Cons) II-1/46.2 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2020
Resolution: Received class report attesting to proper operation of power management system.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 November 2019 Resolved
Port steering gear experienced a momentary loss of steering in the control unit. Properly locate failure, make repairs and conduct testing to the satisfaction of attending classification society. SOLAS (74 CONS) 81 AMEND II-1/29.5.1
Action required: 15 - Rectify deficiencies by next port
Resolved 10 December 2019
Resolution: Referred to ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported loss of propulsion while at sea. Vessel required to have escort tug from sea buoy to mooring. Vessel shall use 2 tugs with a aggregate total horsepower of 5,000 or 50 ton bollard pull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2019
Resolved 27 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Determine cause of loss of propulsion and provide class report attesting to repairs and condition.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 27 July 2019
Resolution: ABS Report # NN3705633
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2019 Resolved
SINGLE NON-CONCURRENT FAILURES IN CONTROL, ALARM OR INSTRUMENTATION SYSTEMS AND LOGICAL CONSEQUENCES MUST NOT PREVENT SUSTAINED OR RESTORED OPERATION OF ANY VITAL SYSTEM. ALL 6 SCR(S) BREAKERS FOR DIESEL ELECTRIC PROPULSION TRIPPED SIMULTANEOUSLY, RESULTED IN LOSS OF PROPULSION. CAUSE BELIEVED TO BE CABINET DOOR SWICH SAFETU CIRCUIT.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 23 July 2019
Resolved 27 July 2019
Resolution: ABS Report #NN3705633
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 June 2019 Resolved
74 SOLAS III/ 9(a) All motor lifeboats shall be equipped with a compression ingnition engine and kept as so to be at all times ready for immediate use. Vessel reported port lifeboat engine is inoperative and requires replacement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2019
Resolution: ABS attended vessel to clear def and verify port lifeboat operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 May 2019 Resolved
Means of identifying the ship to which the lifeboat belongs and the number of the lifeboat shall be marked in such a way that they are visible from above. Both lifeboats are missing their numbers. 74 SOLAS (14) III/31.1.1.1, LSA IV/4.4.9.3
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2019
Resolution: ABS Report # NN3685692
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 29 May 2019 Resolved
Each line throwing appliance must also have an auxiliary line that has a breaking strength of 9000 lbs., is of a dark color or certified to be UV resistant, and is at least 1500 ft. long. Messenger line provided does not appear to meet the criteria and ship was unable to provide specifications. 46 CFR 199.170(c), U.S. Supplement Section II-12
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2019
Resolution: ABS Report # NN3685692
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
Equipment not intended to become live should be adequately protected. Dead end wire found unsecured. 74 SOLAS Unamended II-1/27
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Corrected on the spot. Ships crew removed dead end wire.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 29 May 2019 Resolved
Equipment should be maintained in the condition it was surveyed. Found household fan installed to the backside of the Modine heater in the EDG space. 74 SOLAS I/11
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Corrected on the spot. Ships crew removed the household fan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2019 Resolved
Equipment should be maintained in the condition it was surveyed. Found port steering gear hydraulic relief valve missing copper crush ring and leaking hydraulic oil. 74 SOLAS I/11
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Corrected on the spot. Ships crew installed missing copper crush ring and tested in the presence of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2019 Resolved
Every lifebuoy intended to operate the quick-release arrangement provided for the self-activated smoke signals and self-igniting lights, shall have a mass of not less than 4 kg. The port bridge wing ring lifebuoy had a mass of 2.5 kg. 74 SOLAS (14) III/1.3, LSA II/2.1.1.7
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel was able to provide an additional ring lifebuoy of the correct size, 4 kg.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2019 Resolved
Lifebuoy self-activating smoke signals shall be provided with a quick release arrangement that will automatically release and activate the signal and associated self-igniting light connected to the ring lifebuoy. The port bridge wing self-activating smoke signal's lanyard was too short and not in accordance with the manufacturer's specifications. 74 SOLAS (14) III/1.3, LSA II/2.1.3.6
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew replaced the lanyard with one of the correct length.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 May 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship will remain fit to proceed to sea with out danger to the ship or persons on board. Vessel had expired pyro stowed alongside the good pyro in the bridge pyro locker. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew removed the pyro to a different location for training purposes.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 29 May 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship will remain fit to proceed to sea with out danger to the ship or persons on board. One lifeboat radio battery was found unsealed. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew was able to provide an additional sealed lifeboat battery.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 29 May 2019 Resolved
Posters or signs that illustrate the purpose of controls and the procedures for operating the appliance shall be provided on or in the vicinity of survival craft and their launching controls. Port and starboard lifeboat instructions were not posted in the vicinity of the lifeboat launching controls. 74 SOLAS (14) III/9.2.1
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew repositioned the lifeboat launching instructions to the control stations for both port and starboard lifeboats.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 May 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship will remain fit to proceed to sea with out danger to the ship or persons on board. One starboard side liferaft had a hydrostatic release unit that had expired. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew was able to provide an additional HRU that was not expired for the staboard liferaft.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 May 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship will remain fit to proceed to sea with out danger to the ship or persons on board. Vessel had compressed gas cylinders stowed that were outside of their hydrostatic test dates. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew removed from service the compressed gas cylinders with expired hydrostatic test dates.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 May 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship will remain fit to proceed to sea with out danger to the ship or persons on board. Port waste oil tank vent was missing its flame screen. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2019
Resolution: Vessel's crew installed new flame screen on gooseneck vent.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 15 May 2018 Resolved
All lifesaving equipment must be ready for immediate use. Found numerous food rations on port lifeboat had lost vacuum seal, which voids the expiration date. Renew with required amount for the capacity of the lifeboat.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2018
Resolved 29 November 2018
Resolution: ABS Report NN3499306-A
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 May 2018 Resolved
Stairtower self-closing fire doors 1-35 1/2-1 and 1-35 1/2-2do not fully close and latch. Repair/adjust doors for positive closure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 29 November 2018
Resolution: ABS Report NN3499306
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 15 May 2018 Resolved
One battery, for the three two-way portable lifeboat hand held radios, had a broken tamper proof seal. Renew battery with sealed unused battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 29 November 2018
Resolution: ABS Report NN3504537-B
Lifesaving › Launching Appliances › Davit
Issued 3 May 2017 Resolved
Rescue boat davit proof of approval is missing. Provide proof of USCG approval to the CG Marine Inspector
Due 2 June 2017
Resolved 19 May 2017
Lifesaving › Rescue Boat › Markings
Issued 3 May 2017 Resolved
Rescue boat approval is missing. Provide proof of USCG approval to the CG Marine Inspector.
Due 2 June 2017
Resolved 19 May 2017
Lifesaving › Launching Appliances › Release Mechanism
Issued 3 May 2017 Resolved
Demonstrate ability to launch rescue boat in 5 kts headway to the CG Marine Inspector.
Due 2 June 2017
Resolved 19 May 2017
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 26 August 2015 Resolved
Loss of operation to the bow thruster #2, the port propeller, and port propeller shaft due to a blown fuse in a Silicon Control Relay (SCR) which caused the loss of bow thruster that cause vessel to drift and pulled towing/umbilical cable around the port propeller and shaft.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2015
Resolved 3 September 2015
Resolution: Since the vessel is ACP, ABS has assumed responsibility for the deficiency.
Electrical › Electric Generation Source (emergency) › Switch
Issued 14 October 2014 Resolved
Solenoid coil for hydraulic start valve for emergency diesel generator failed. Repair/replace as original solenoid coil and prove proper operation to the satisfaction of attending USCG marine inspector prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2014
Resolved 17 October 2014
Resolution: Corrected and tested to the satisfaction of attending USCG marine inspector and attending ABS surveyor.
Engineering › Bilge Water Management System › Pump
Issued 29 May 2014 Resolved
Newly installed OWS, marked with model numbers Bilgemaster E-2000 and GEA WSE20-01-37 had no CG Approval on nameplate or CG Approval certificate. Provide proof of CG approval.
Action required: 705 - Other - as specified
Due 25 November 2014
Resolved 3 September 2014
Resolution: Installed OWS was an improperly labeled Bilgmaster E-2500. New label and supporting documentation was received.
Fire Fighting › Structural - B Class Divisions › Corridors
Issued 29 May 2014 Resolved
There are multiple unsealed penetrations in the B Class structural fire bulkheads between the staterooms and the corridors. Survey all B Class bulkheads and properly seal as needed with CG approved/accepted fire stop material.
Action required: 705 - Other - as specified
Due 25 November 2014
Resolved 27 May 2015
Lifesaving › Launching Appliances › Davit
Issued 22 February 2012 Resolved
Operationally test lifeboat davit and releasing gear under a load of 1.1 times the total mass of the lifeboat when loaded with its full complement of persons and equipment, and conduct dynamic test of the winch brake (wet and dry).
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2012
Resolved 12 March 2012
Resolution: Tests complete. COI Amended
Fire Fighting › Structural - A Class Divisions › Doors
Issued 22 February 2012 Resolved
Repair or replace all four A-0 fire doors leading to and from the galley.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2012
Resolved 12 March 2012
Resolution: All four class-A fire doors in galley were repaired to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Air Pipe
Issued 22 February 2012 Resolved
Repair or replace deteriorated and broken goose-neck vent leading to fuel oil tank #2 on port side 01 level.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2012
Resolved 12 March 2012
Resolution: Repairs made to the satisfaction of the attending MI.
Deck/Cargo › Ballast › Valves
Issued 22 February 2012 Resolved
Prove proper operation of the ship's ballast transfer system, including all remotely operated valves.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2012
Resolved 26 March 2012
Resolution: Repairs completed to the satisfaction of the attending MI.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 22 February 2012 Resolved
Prove proper operation of the vessel's sewage collection, holding and transfer (CHT) system.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2012
Resolved 13 March 2012
Resolution: Replacement of piping from collection to holding tank was made.
Stability › Watertight Integrity › General
Issued 22 February 2012 Resolved
Repair sea chest valve leading to the auxiliary salt water pump duplex strainer in the aft pump room.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2012
Resolved 26 March 2012
Resolution: Valve changed our w/ cast iron gate valve. Notified vessel that cast iron is not authorized for skin valves. Vessel replaced with approved valve.
Engineering › Steam System (auxiliary) › Piping
Issued 22 February 2012 Resolved
Conduct hydro-blast of watersides of both #1 & 2 ships boilers to remove excessive oxygen scabbing; provide previous audio gauging reports and latest Fosfo/wheeler report: 46 CFR 54.01-35; 46 CFR 61.05-10
Action required: 705 - Other - as specified
Resolved 22 March 2012
Resolution: Hydro-clean completed. MI attended.
Engineering › Steam Boiler (auxiliary/waste heat) › Water Wall
Issued 1 January 2012 Resolved
Treat/arrest corrosion in the way of pitting found in boiler tubes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2012
Resolved 24 March 2012
Engineering › Steam Boiler (auxiliary/waste heat) › Water Wall
Issued 1 January 2012 Resolved
Provide tube report to determine material condition of boiler tubes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2012
Resolved 24 March 2012
Engineering › Diesel Engine (propulsion-electric) › Gear/Clutch Starter (electric)
Issued 1 January 2012 Resolved
Prove proper operation of STBD propulsion motor. Main breaker cannot hold the load for fwd or astern propulsion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2012
Stability › Watertight Integrity › General
Issued 1 January 2012 Resolved
Prove proper operation of audible alarm for aft watertight door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2012
Resolution: Proved proper operation of audible alarm for aft watertight door.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 1 January 2012 Resolved
Prove proper operation of #5 (3-96-6) fire damper serving engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2012
Resolution: Proved proper operation of #5 (3-96-6) fire damper serving engine room.
Stability › Watertight Integrity › General
Issued 1 January 2012 Resolved
Prove proper operation of bilge alarms serving FWD and AFT pump rooms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2012
Resolution: Proved proper operation of bilge alarms serving FWD and AFT pump rooms.
Engineering › Diesel Engine (propulsion-electric) › Silencer (exhaust)
Issued 1 January 2012 Resolved
Reinstall exhaust lagging on #4 SSDG to the satisfaction of the attending MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2012
Engineering › Generator (propulsion-electric) › Indicator Circuitry
Issued 1 January 2012 Resolved
Prove proper operation of #2 stern thruster analog tachometer prior to completion of next annual inspection. DPS tachometer permitted for use.
Action required: 705 - Other - as specified
Resolved 23 May 2012
Resolution: Proved proper operation of #2 stern thruster and cleared the same.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 30 March 2011 Resolved
Issued an CG-835 to prove proper operation of the DP system once the permanent repair has been put in place.
Due 30 May 2011
Resolved 25 May 2011
Resolution: Cleared a CG-835 to prove proper operation of the DP system with the manufacturers permanent repair in place. Witnessed satisfactory test of DP system.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 24 February 2011 Resolved
#1 Generator main breaker failed during sea trials. #3 Generator load share voltage regulator failed during sea trials. # 2,4,and 5 Ship service generator remain in service.
Due 24 March 2011
Resolved 22 March 2011
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 24 February 2011 Resolved
After the newly installed vital system automation, the Dynamic Positioning system would not function properly during sea trials.
Due 24 March 2011
Resolved 30 March 2011
Resolution: Witnessed the proper operation of the DP system with the temporary installment of approved resistors in place. Issued an CG-835 to prove the proper operation of the DP system once the permanent repair is in place NLT 5/30/2011.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 18 February 2011 Resolved
Prove proper operation of hydraulic starting system. The emergency generator could not provide 3 of the 6 required starts from the primary source.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 29 March 2011
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 18 February 2011 Resolved
Prove proper operation of remote operator of emergency fire pump suction valve to the satisfacton of a CG marine inspector. Valve to remain in the open position until resolved.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 22 March 2011
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 18 February 2011 Resolved
Update fire control plan to reflect the new designation the converted stateroom to sonar equipment room 3-27 1/2-1 to the satisfaction of the attending CG inspector.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 22 March 2011
Documentation › Certificates/Documents › Stability Letter
Issued 18 February 2011 Resolved
Provide permanent stability letter/stability and trim booklet updates to the satisfaction of attending CG inspectior. Vessel underwent inclining test due to hull mods.
Action required: 705 - Other - as specified
Due 1 June 2011
Resolved 25 May 2011
Fire Fighting › Ventilation Systems › Operating Controls
Issued 18 February 2011 Resolved
Install a manual means to close two automatic fire dampers, located in sonar room, from out side the affected space prior to departing on vessel next mission. Space must be manned with live fire watch during sea trials.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 29 March 2011
Construction/Loadline › Structures › Machinery Space Opening
Issued 18 February 2011 Resolved
Renew tempary penetration with bulkhead insert for sonar room bulkhead adjacent to corridor prior to vessel next mission.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 22 March 2011
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 15 March 2010 Resolved
fire boundary in bow thruster room and crew's laundary were missing or had improper fire stop.
Condition: Improper/Lack of Maintenance
Due 8 April 2010
Resolved 8 April 2010
Resolution: renewed with proper fire stop.
Lifesaving › Line-Throwing Appliances › Lines
Issued 15 March 2010 Resolved
Auxillary line for rocket propelled linethrowing devise was missing
Condition: Improper/Lack of Maintenance
Due 8 April 2010
Resolved 8 April 2010
Resolution: renewed line.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 13 February 2009 Resolved
Remove all hazardous materials from 2nd deck aft flat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2009
Lifesaving › Lifeboat › Hull
Issued 13 February 2009 Resolved
Prove satisfactory condition of stbd lifeboat structure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2009
Electrical › Electric Generation Source (emergency) › Generator
Issued 13 February 2009 Resolved
Prove proper operation of emergency diesel generator automation safeties: overspeed & high temperature.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2009
Engineering › Fuel Oil Service System › Valve, Control
Issued 13 February 2009 Resolved
Prove proper operation of hydraulicly-actuated emergency fuel oil securing valves.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2009
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 13 February 2009 Resolved
Repair/replace missing and damaged insulation in crew laundry, repair locker # 2 and cable deck overhead.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 17 March 2009
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 13 February 2009 Resolved
Repair leaking valves (2) in sponsor store room.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 20 February 2009
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 13 February 2009 Resolved
Grease locer and paint locker bulkheads missing insulation as shown on fire control plan. Bulkheads are A-0 and should be A-60.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 13 March 2009
Resolution: Def opened in error. SOLAS requirements and CFR requirements require an A-0 Bulkhead
Fire Fighting › Grease Extraction Hood › General
Issued 13 February 2009 Resolved
Secure electrical power to deep fat fryers until repairs are made to automatic shutdowns associated with fixed firefighting are corrected.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 20 February 2009
Engineering › Diesel Engine (propulsion-electric) › Valve Actuating Gear
Issued 13 February 2009 Resolved
Prove proper operation of EDG safeties automation (overspeed & high temp). EDG shall be manned by a licensed engineer in pilotage/maneuvering ops.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 20 February 2009
Engineering › Diesel Engine (propulsion-electric) › Valve Actuating Gear
Issued 13 February 2009 Resolved
Prove proper operation of #2 SSDG.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 20 February 2009
Engineering › Diesel Engine (propulsion-electric) › Valve Actuating Gear
Issued 13 February 2009 Resolved
Prove proper operation of #1 SSDG auto-sync. Ensure engine room manning of 1 licensed engineer and 1 oiler until cleared.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 20 February 2009
Engineering › Diesel Engine (propulsion-electric) › Valve Actuating Gear
Issued 13 February 2009 Resolved
Provide approved automation test procedures.
Action required: 705 - Other - as specified
Due 31 August 2010
Resolved 3 September 2010
Resolution: Vessel has manned engine room and does not want to go unmanned.
Deck/Cargo › Ballast › Valves
Issued 13 February 2009 Resolved
Prove proper operation of 6-32-2 ballast wing tank valve.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 20 February 2009
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Waterwall Drain
Issued 13 February 2009 Resolved
Crop & renew #2 boiler wasted steam drain.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 20 February 2009
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 13 February 2009 Resolved
Prove proper operation of #1 and #2 AC units.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 20 February 2009
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 13 February 2009 Resolved
Replace/repair laundry room door.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 13 March 2009
Resolution: Repaired laging in damaged areas.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 13 February 2009 Resolved
Repair noted cracks on port side accommodation ladder.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 13 March 2009
Resolution: Repaired cracks.
Construction/Loadline › Structures › Scupper
Issued 13 February 2009 Resolved
Remove damage control plug and properly repair deck drain in sponsor store room.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 20 February 2009
Deck/Cargo › Holds/Tanks › Cargo Tank Drainage
Issued 7 February 2008 Resolved
Provide repair plan for the remaining kick pipes, Goose necks and hand rails that are required to be replaced.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 12 February 2008
Resolution: Provided plan to make repairs.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 February 2008 Resolved
Provide repair plan for the rusted connection/electrical boxes under the starboard stairwell on the 01 deck.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 12 February 2008
Resolution: Provided plan to make proper repairs.
Engineering › Freshwater Generation System › Piping
Issued 7 February 2008 Resolved
Repair/Replace the valve on the hot potable water line just fwd of FSD 3-22-1.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 12 March 2008
Resolution: Replaced Valve.
Deck/Cargo › Cargo Stowage › General
Issued 7 February 2008 Resolved
Repair holes in the overhead of the laundry room on the 3 deck.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 12 March 2008
Resolution: Repaired holes to meet fire protection.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 February 2008 Resolved
Readjust the FSD 3-22-1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2008
Resolution: Readjusted door to close itself.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 7 February 2008 Resolved
Replace #7 Hydraulic fuel oil storage tank valve.
Action required: 705 - Other - as specified
Due 12 March 2008
Resolved 25 February 2008
Resolution: Inspected valve. All sat.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 7 February 2008 Resolved
Fix/repair/replace manual relieving gear to #1 boiler.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2008
Resolution: Repaired relieving gear to operate properly.
Fire Fighting › Ventilation Systems › Ducts
Issued 7 February 2008 Resolved
Prove proper operation of the fire damper in the galley.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2008
Resolution: Proved proper operation of the fire damper.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 June 2007 Resolved
Install new dry chemical fire extinguisher mounting brackets throughout vessel.
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 25 July 2007
Resolution: New dry chemical fire extinguisher brackets properly mounted throughout vessel.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 June 2007 Resolved
Update and submit for approval the ships fire control plan. Show change of newly installed dry chemical portable fire extinguishers (C-1).
Action required: 705 - Other - as specified
Due 30 October 2008
Resolved 15 August 2008
Resolution: Plan appears to be updated and corrected as required.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 25 June 2007 Resolved
Install IMO approved symbols throughout ship marking route to embarkation stations and lifeboats.
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 25 July 2007
Resolution: Approved IMO symbols installed to mark route to embarkation stations and lifeboats.
Lifesaving › Lifeboat › Seating
Issued 25 January 2006 Resolved
Mark lifeboat seating arrangment on port and starboard boats to minimize confusion during loading.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 13 March 2006
Resolution: Corrected.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 25 January 2006 Resolved
Repair or make operable ventilation dampers where failed throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 13 March 2006
Resolution: Corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 25 January 2006 Resolved
Apply identification marking on CO2 siren in main machinery space in upper level engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 13 March 2006
Resolution: Corrected.
Fire Fighting › Ventilation Systems › Ducts
Issued 25 January 2006 Resolved
Repair laundry vent screens in laundry space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 13 March 2006
Resolution: Corrected.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 25 January 2006 Resolved
Ensure ships emergency generator is able to start 6 times on hydraulic start.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 13 March 2006
Resolution: Operator error. There is a bypass button that will by pass the alarms and allow the generator to be started.
Stability › Watertight Integrity › General
Issued 25 January 2006 Resolved
Install 10 second time delay on watertight doors.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 10 October 2006
Resolution: Time delays have been installed.
Engineering › Compressed Air System (start air) › Valve
Issued 17 February 2004 Resolved
Prove proper operation of all pressure vessel safeties under pressure. LEGACY COMPONENT DESC: Valve
Due 18 March 2004
Resolved 16 March 2004
Fire Fighting › Structural - A Class Divisions
Issued 17 February 2004 Resolved
Make penetrations of aft bulkhead of main engine room (port) near #2 boiler safeties meet A-60 standard. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Due 18 March 2004
Resolved 15 March 2004
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 17 February 2004 Resolved
Modify automation test procedure for testing of speed and direction controls for main propulsion motors at MCC to reflect the actual method used to prove operation. Submit revised procedures for CG review, approval, and validation. LEGACY COMPONENT DESC: Automation Test Procedure
Due 18 March 2004
Resolved 9 December 2004
Resolution: Component "Block" selected for this deficiency at the clearing of this requirement only to satisfy MISLE''s requirement that something be added to this block. None of the actual pull-down selection options fit this actual deficiency.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 17 February 2004 Resolved
Comply with ABS outstanding requirement to install a remotely operated valve to the waste oil sludge tank located in the incinerator space. The vessel is restricted from operating the incinerator until this item is satisfied. LEGACY COMPONENT DESC: Valve
Due 18 March 2004
Resolved 16 March 2004
Fire Fighting › Structural Fire Protection - General
Issued 17 February 2004 Resolved
Provide fire control plan that reflects the current configuration of the vessel. LEGACY COMPONENT DESC: Fir control plan
Due 19 March 2004
Resolved 15 March 2004
Lifesaving › Launching Appliances
Issued 17 February 2004 Resolved
Renew lifeboat falls with wire rope which is rotation resistant in accordance with 46 CFR 199.153 (b) and follow with weight test. LEGACY COMPONENT DESC: Falls
Due 19 March 2004
Resolved 20 February 2004
Resolution: Item rescinded after review of G-MSE e-mail from [name withheld] re: renewal in kind of lifeboat falls on COLORADO VOYAGER. Included policy in vessel/activity file.
Electrical › Electrical Distribution System (service)
Issued 3 June 2003 Resolved
Provide documentation that voltage regulators on all generators have been certified to operate in accordance with the manufactures design. LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 1 December 2003
Resolved 15 July 2003
Electrical › Electric Supply System (service)
Issued 20 May 2003 Resolved
Upon completion of sea-trails OOA 23MAY03, make proper repairs & testing of the SST1 breaker in accordance with Marine Safety Center letter #E2-0305135, paragraph 4. LEGACY COMPONENT DESC: Interlock
Action required: 705 - Other - as specified
Due 28 February 2004
Resolved 17 February 2004
Resolution: Cleared
Electrical › Electric Supply System (service)
Issued 19 May 2003 Resolved
Properly clean dust, dirt and debris from semi-conductor rectifier and main switchboards. LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 28 February 2004
Resolved 17 February 2004
Resolution: Corrected
Electrical › Electric Supply System (service)
Issued 19 May 2003 Resolved
Replace dry-rotted grommets and electrical connectors for the semi-conductor rectifiers heates. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 28 February 2004
Resolved 17 February 2004
Resolution: Cleared
Electrical › Electric Supply System (service)
Issued 19 May 2003 Resolved
Properly repair failing insulation tape on breaker legs in main switchboards. LEGACY COMPONENT DESC: Breaker Leg Phase Insulation
Action required: 705 - Other - as specified
Due 28 February 2004
Resolved 17 February 2004
Resolution: Cleared
Documentation
Issued 19 May 2003 Resolved
Provide "Approved" installation drawings from Marine Safety Center for the new marine sanitation device. LEGACY COMPONENT DESC: Approved MSD Installation Drawings
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 14 August 2003
Resolution: Approved drawings were provided to MSO Hampton Roads.
Documentation
Issued 19 May 2003 Resolved
Provide "Approved" drawings from Marine Safety Center for the newly installed incinerator. LEGACY COMPONENT DESC: Approved Incinerator Drawings
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 14 August 2003
Resolution: Approved drawings were provided to MSO Hampton Roads.
Pollution Prevention/Response › Prevention Equipment
Issued 19 May 2003 Resolved
Prior to operating, prove proper operation of all safety devices (including fixed fire extinguishing system) to Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Incinerator
Action required: 705 - Other - as specified
Due 28 February 2004
Resolved 17 February 2004
Resolution: Cleared
Electrical › Lighting (emergency)
Issued 19 May 2003 Resolved
Replace burnt out lights or repair emergency lighting circuit on switchboard. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 28 February 2004
Resolved 17 February 2004
Resolution: Cleared
Electrical › Electric Supply System (service)
Issued 19 May 2003 Resolved
Provide "APPROVED" switchboard drawings by Marine Safety Center. LEGACY COMPONENT DESC: Switchboards
Due 19 June 2003
Resolved 30 May 2003
Resolution: Vessel provided "APPROVED" drawings from the Marine Safey Center.
Documentation › Certificates/Documents
Issued 19 May 2003 Resolved
Provide ABS annual endorsement on Load Line Certificate. LEGACY COMPONENT DESC: Coastwise Load Line Certificate
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 19 May 2003
Fire Fighting › Structural - A Class Divisions
Issued 19 May 2003 Resolved
Adjust self closing fire door to incinerator room to properly close and latch. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 30 May 2003
Fire Fighting › Structural - A Class Divisions
Issued 19 May 2003 Resolved
Adjust fire door to special project room to properly latch closed. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 30 May 2003
Electrical › Lighting (service)
Issued 19 May 2003 Resolved
Renew broken light covers for incinerator room. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 30 May 2003
Documentation
Issued 19 May 2003 Resolved
Provide approved drawings for fire dectection system.
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 19 December 2003
Documentation
Issued 19 May 2003 Resolved
Provide approved drawings for incinerator room fixed CO2 system prior to operating the incinerator. LEGACY COMPONENT DESC: Approved CO2 drawing
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 27 August 2003
Resolution: Approved drawings for the incinerator room have been provided.
Documentation
Issued 19 May 2003 Resolved
Provide approval for the installation of the new MG sets in the special project room.
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 27 August 2003
Resolution: Approved drawings were provided for the newly installed 150 Kw motor generators.
Fire Fighting › Structural - A Class Divisions
Issued 19 May 2003 Resolved
Make all cable ways and pipe penetrations fire tight in bulkheads of special project room that are adjacent ot passage ways. (use CG approved material) LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Action required: 705 - Other - as specified
Due 28 February 2004
Resolved 17 February 2004
Resolution: Cleared
Fire Fighting › Structural - A Class Divisions
Issued 9 May 2003 Resolved
Make all cable ways and pipe penetrations fire tight in incinerator room in bulkheads that are adjacent to passageways and garbage room (use CG approved material) LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Action required: 705 - Other - as specified
Due 28 February 2004
Resolved 17 February 2004
Resolution: Cleared
Fire Fighting › Structural - A Class Divisions
Issued 28 March 2003 Resolved
VESSEL IS TO PROVIDE APPROVED DRAWING FOR INSTALLATION/STUCTURAL FIRE FIGHTING FOR INCINERATOR/SPACE PRIOR TO OPERATION OF INCINERATOR. DURING PERIODIC EXAM, VENTILATION FOUND NOT IAW REGULATIONS. (CURRENT APPROVED DRAWING ONBOARD BY ABS DOES NOT ADDRESS STRUCTURAL FIRE PROTECTION) LEGACY COMPONENT DESC: Bulkheads - Aux Spaces (moderate fire risk)
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 17 February 2004
Resolution: Corrected
Electrical › Electrical Distribution System (service)
Issued 28 March 2003 Resolved
Provide a damage survey report and repair proposal for fire damaged switchboards and all affected equipment. Clear to the satisfaction of the attending Coast Guard Marine Inspector prior to sailing. LEGACY COMPONENT DESC: Panelboard
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2003
Resolution: Damage report and repair proposal have been received and reviewed.
Electrical › Electric Supply System (service)
Issued 28 March 2003 Resolved
Provide "Die-Electrical" testing of all switchboards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2003
Resolution: Conducted satisfactory die-electric test on all switchboards.
Electrical › Electrical Distribution System (service)
Issued 25 March 2003 Resolved
MAKE PERMANENT REPAIRS TO SWITCHBOARD DAMAGED IN FIRE IN # 2 MACHINERY ROOM. LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 25 March 2003
Resolution: Cleared by HMRMS to issue our own no-sail 835 to take control of the vessel.
Fire Fighting › Fixed Fire Detection System
Issued 6 February 2002 Resolved
Prior to getting underway prove proper operation of the heat and smoke detection system. LEGACY COMPONENT DESC: Heat Detectors
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2002
Resolved 20 February 2002
Resolution: tested system
Navigation › Collision/Grounding Avoidance
Issued 6 February 2002 Resolved
Prior to getting underway prove proper operation of Radar and ARPA. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2002
Resolved 20 February 2002
Resolution: Tested ARPA''s
Personnel › Certificates/Documents/Licenses
Issued 6 February 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2002
Resolved 21 February 2002
Operations/Management › Drills/Instruction
Issued 6 February 2002 Resolved
Prior to getting underway conduct proper fire and abandon ship drill to the satisfaction of an attending Marine Inspector. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2002
Resolved 21 February 2002
Resolution: Drills conducted and are sat. Launched port lifeboat and observed underway.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 6 February 2002 Resolved
Provide proper instructions for discharging Halon system protecting main machinery space. LEGACY COMPONENT DESC: Operating Controls
Due 15 March 2002
Resolved 4 March 2002
Construction/Loadline › Structures
Issued 6 February 2002 Resolved
Prove proper operation of manual closure for watertight door #1.
Due 15 March 2002
Resolved 20 February 2002
Resolution: Tested sat.
Documentation › Safety/Response Plans/Programs
Issued 6 February 2002 Resolved
Provide a Coast Guard approved Fire Control Plan. LEGACY COMPONENT DESC: Fire Control Plans
Due 15 March 2002
Resolved 4 March 2002
Resolution: Approved plan provided
Accommodation/Occupational Safety › Potable Water System
Issued 6 February 2002 Resolved
Prior to using emergency potable water tank provide documentation from the Department of Health representative that inspection was conducted and tank is in satisfactory condition.
Due 15 March 2002
Resolved 4 March 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 6 February 2002 Resolved
Replace 30sec time delay protecting machinery space #1. LEGACY COMPONENT DESC: Operating Controls
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2002
Resolved 15 February 2002
Resolution: Time delay replaced.
Fire Fighting › Structural - A Class Divisions
Issued 6 February 2002 Resolved
Prior to getting underway prove proper operation of all fire doors throughout the vessel. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2002
Resolved 15 February 2002
Resolution: All doors working properly.
Fire Fighting › Fire Hoses
Issued 6 February 2002 Resolved
Remove all hoses that do not meet UL testing standard. LEGACY COMPONENT DESC: Material
Due 15 March 2002
Resolved 15 February 2002
Resolution: Unapproved hoses removed.
Construction/Loadline › Structures
Issued 6 February 2002 Resolved
Provide directions for manual controls for watertight doors indicating which way the door opens and closes.
Due 15 March 2002
Resolved 15 February 2002
Resolution: Markings placed for open/close.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 February 2002 Resolved
Remove lights from Liferings requiring extra line. Lights and line can not be combined on same ring.
Due 15 March 2002
Resolved 15 February 2002
Engineering › Generator (propulsion-electric)
Issued 6 February 2002 Resolved
Prior to departure install proper vent drains for air boxes on all generator (1-5).
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2002
Resolved 21 February 2002
Electrical
Issued 6 February 2002 Resolved
Remove or seal dead end cable in machinery room #2.
Due 23 February 2002
Resolved 21 February 2002
Resolution: Removed
Engineering › Pressure Vessel
Issued 6 February 2002 Resolved
Repair/replace relief valves on LPA and HPA receivers. LEGACY COMPONENT DESC: Relief Valve
Due 23 February 2002
Resolved 21 February 2002
Fire Fighting › Structural Fire Protection - General
Issued 6 February 2002 Resolved
Make repairs to MCT block, which is open around the cable, in stair tower, 2nd deck, starboard side at frame 41,41.5, and 42).
Due 15 March 2002
Resolved 21 February 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 6 February 2002 Resolved
Make all fire extinguishers mounted in correct brackets as required. LEGACY COMPONENT DESC: Mounting Bracket
Due 15 March 2002
Resolved 21 February 2002
Documentation
Issued 29 February 2000 Resolved
PROVIDE UPDATED STABILITY DATA REFLECTING ADDITION OF STBD CRANE TO USCG FRO REVIEW AND APPROVAL PRIOR TO TRANSITING OUTSIDE OF THE CHESAPEAKE BAY.
Condition: Unknown
Due 30 March 2000
Resolved 10 March 2000
Fire Fighting
Issued 29 February 2000 Resolved
PROVIDE PERMANENT REPAIRS TO CLOSURE FOR FSD 4-37-2 (TO MACHINERY ROOM 1).
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Lifesaving
Issued 29 February 2000 Resolved
MAKE PERMANENT REPAIRS TO LIFEBOAT NUMBER 1 ENGINE PRIOR TO TRANSITING OUTSIDE OF CHESAPEAKE BAY AND TRIBUTARIES.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Construction/Loadline
Issued 24 February 1999 Resolved
Prove proper operation and sealing of all watertight doors
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Lifesaving
Issued 24 February 1999 Resolved
Prove proper operation of port lifeboat by running in water.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Lifesaving
Issued 5 January 1998 Resolved
PROVE PROPER OPERATION OF LIMIT SWITCHES ON LIFEBOAT #1.
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Lifesaving
Issued 5 January 1998 Resolved
MAKE PERMANENT REPAIRS TO WATERTIGHT LOCKER FOR DISTRESS SIGNAL STOWAGE.
Condition: Unknown
Due 5 February 1998
Resolved 6 January 1998
Documentation
Issued 12 January 1995 Resolved
Prior to completing inspection for certification vessel is restricted to one (1) movement from NOB, Norfolk to Colonna Shipyard, Norfolk, Virginia.
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Lifesaving
Issued 23 December 1994 Resolved
UPON RECEIPT OF LIFEBOAT PROVISIONS, FAX RECEIPT TO [phone withheld]. THESE MUST BE ON BOARD PRIOR TO OPERATING, WITH EXCEPTION OF LOCAL SEA TRIALS, AND NO LATER THAN 5 JAN 94.
Condition: Unknown
Due 5 January 1995
Resolved 19 January 1995
Engineering
Issued 14 January 1994 Resolved
OPEN BOILER MOUNTS FOR INSPECTION._x001C_
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Lifesaving
Issued 14 January 1994 Resolved
MAKE PERMANENT REPAIR TO THE NO.2 LIFEBOAT BOTTOM.
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Fire Fighting
Issued 14 January 1994 Resolved
CONDUCT ANNUAL SERVICING OF ALL THE CO2 FIREFIGHTING SYSTEM AND VENTILATIONSHUTDOWN.
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Engineering
Issued 14 January 1994 Resolved
OPEN BOILERS TO CONDUCT WATERSIDE, FIRESIDE, EXTERNAL EXAM AND OPERATIONAL TEST OF THE SAFETY RELIEF VALVES.
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Documentation
Issued 14 January 1994 Resolved
UPDATE OIL TRANSFER PROCEDURES AND SUMP DRAINING PRACTICES.
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Lifesaving
Issued 14 January 1994 Resolved
CONDUCT LIFEBOAT WEIGHT TEST AND ANNUAL SERVICING OF THE PORT AND STBD _x001C_ LIFEBOATS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Lifesaving
Issued 14 January 1994 Resolved
END FOR END THE LIFEBOAT DAVIT FALLS FOR THE PORT AND STBD LIFEBOATS._x001C_
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Engineering
Issued 14 January 1994 Resolved
CONDUCT HYDRO OF TWO (2) CABLES DRUM AIR RECEIVERS AND TWO (2) SMALL AIR RECEIVERS.
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Construction/Loadline
Issued 6 January 1993 Resolved
AT NEXT AVAILABLE DRYDOCK OR WHENEVER #1 & #2 FUEL OIL TANKS ARE GAS FREE (WHICHEVER OCCURS FIRST) PROVDE AND INSTALL A SUITABLE ACCESS TO THE VOID LOCATED BETWEEN #1 & #2 FUEL OIL TANKS, IN WAY OF FRAME #22.
Condition: Unknown
Due 6 January 1993
Resolved 6 January 1993
Engineering
Issued 6 January 1993 Resolved
PROVE OPERATION OF #1 AUX. BOILER TO INCLUDE ALL AUDIO & VISUAL ALARMS & SHUTDOWNS.
Condition: Unknown
Due 6 January 1993
Resolved 6 January 1993
Unknown
Issued 23 April 1992 Resolved
SUBMIT A REQUEST TO MAKE TEMP. REPAIRS IN LIEU OF PERM. REPAIRS TO THE COGNIZANT [name withheld] PERM. REPAIRS CANNOT BE MADE. INCLUDE TEMP. REPAIR PROPOSAL WITH REASONS WHY TEMP. PROPOSAL WOULD BE ACCEPTABLE UNTIL NEXT DDX, LOOKING AT VESSEL'S SERVICE.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 23 April 1992 Resolved
REPLACE BUCKLED BALLAST TANK VENT LINE.
Condition: Unknown
Due 23 April 1992
Resolved 23 April 1992
Construction/Loadline
Issued 23 April 1992 Resolved
CROP OUT AND REPLACE DENTED SIDE SHELL BETWEEN FRAMES 32-34.
Condition: Unknown
Due 23 April 1992
Resolved 23 April 1992
Construction/Loadline
Issued 23 April 1992 Resolved
CROP OUT BUCKLED SECTIONS OF FRAME 33 AND INSERT OR REPLACE FRAME.
Condition: Unknown
Due 23 April 1992
Resolved 23 April 1992
Construction/Loadline
Issued 23 April 1992 Resolved
REPLACE BENT LONGITUDINAL STIFFENERS BETWEEN FRAMES 32-34._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Lifesaving
Issued 3 November 1991 Resolved
PROVIDE SIGNAL SMOKES FOR BRIDGE WING RING BUOYS (2), PORT LIFEBOAT (2), AND STARBOARD LIFEBOAT (2).
Condition: Unknown
Due 3 November 1991
Resolved 3 November 1991
Lifesaving
Issued 3 November 1991 Resolved
REPAIR AND PROVE PROPER OPERATION OF PORT LIFEBOAT ENGINE IN BOTH AHEAD ANDASTERN MODES.
Condition: Unknown
Due 3 November 1991
Resolved 3 November 1991
Lifesaving
Issued 3 November 1991 Resolved
RETHREAD AND/OR RESEAT THE AFT DRAIN PLUG OF THE PORT LIFEBOAT SO THAT IT IS WATERTIGHT.
Condition: Unknown
Due 3 November 1991
Resolved 3 November 1991
Documentation
Issued 24 December 1990 Resolved
SUBMIT PLANS FOR APPROVAL OF SHIP'S SERVICE AIR SYSTEM MODIFICATIONS TO [name withheld].
Condition: Unknown
Due 24 December 1990
Resolved 24 December 1990
Engineering
Issued 24 December 1990 Resolved
PROVE PROPER OPERATION OF THE SHIP'S EVAPORATORS PRIOR TO LEAVING MSO _x001C_ HAMPTON ROADS.
Condition: Unknown
Due 24 December 1990
Resolved 24 December 1990
Engineering
Issued 2 May 1990 Resolved
ENSURE THAT PRESSURE VESSELS ARE PROPERLY MARKED BY A COAST GUARD MARINE IN ACCORDANCE WITH 46CFR 54.10-3 AND 46 CFR 54.10-20. THE MARKING IS TO BEDONE BASED UPON PRESSURE VESSEL DAA AVAILABLE FROM EITHER MSO HAMPTON ROADSOR MSO PUGET SOUND.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990 Resolved
INSTALL PROPERLY SIZED RELIEF VALVES ON PRESSURE VESSELS 1191 AND 1192 IN ACCORDANCE WITH 46 CFR 54.15. AFTER INSTALLATION, THE RELIEF VALVES ARE TO BE TESTED IN THE PRESENCE OF A COAST MARINE INSPECTORS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990 Resolved
ENSURE THAT BOTH LOW PRESSURE CABLE DRUM EMERGENCY AIR RECEIVERS ARE PROPERLY MARKED BY A COAST GUARD MARINE INSPECTOR IN ACCORDANCE WITH 46 CFR 54.10-3 AND 46 CFR 54.10-20. THE MARKING IS TO BE DONE BASED UPON PRESSURE VESSEL DATA AVAILABLE FROM MSO HAMPTON ROADS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 9 February 1990 Resolved
ROVIDE TO THE COGNIZANT OCMI THE FOLLOWINGT INFORMATION ON THE IOW PRESSUREEMERGENCY CABLE DRUM AIR RECEIVERS; MANUFACTURERS DATA RPT PLANS APPROVED BY A PROFESSIONAL ENGINEER. UPON COMPLETION OF THE ABOVE THE COAST GUARD PROPELLER STAMP WILL BE AFFIXED TO THE MANUFACTURERS NAME PLATE.
Condition: Unknown
Due 9 February 1990
Resolved 9 February 1990
Engineering
Issued 9 February 1990 Resolved
PROVIDE TO COGNIZANT OCMI THE FOLLOWING ON PRESSURE VESSELS 1191 AND 1192: MANUFACTURERS DATA, RPTS & PLANS APPROVED BY PROFESSIONAL ENG. A PROPER RELIEF VALVE MUST BE AFFIXED IN ACCORDANCE W/46 CFR 46 54.15. UPON COMPLET-ION OF THE ABOVE A 1 1/4 MAWP HYDRO TEST OR INTERNAL EXAM. BE PERFORMED.
Condition: Unknown
Due 9 February 1990
Resolved 9 February 1990
Lifesaving
Issued 9 February 1990 Resolved
REPLACE AFFF STAINLESS STEEL PORTABLE FIRE EXTINGUISHERS WITH A-II PORTABLEFIRE EXTINGUISHERS THAT ARE ACCEPTABLE FOR MARINE USE BY THE USCG OR PROVIDE INFORMATION TO THE [name withheld] THESE AFFF EXTINGUISHERS ARE ALLOWED FOR MARINE USE BY THE MILITARY SEALIFT COMMAND.
Condition: Unknown
Due 9 February 1990
Resolved 9 February 1990
Electrical
Issued 9 February 1990 Resolved
REPAIR AND TEST PROPER OPERATION OF #2 MAIN DIESEL ENGINE GENERATOR SET.
Condition: Unknown
Due 9 February 1990
Resolved 9 February 1990
Construction/Loadline
Issued 1 November 1989 Resolved
MAKE PERMANENT REPAIRS TO DAMAGED AREA IN WAY OF FRAME 16 PORT SIDE. RE- PAIR TO BE AS ORIGINAL, USING GOOD MARINE PRACTICE. DAMAGE COMPRISES APPROXIMATELY 5' X 14' OF DECK AND ASSOCIATED UNDERDECK LONG AND BEAM.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Construction/Loadline
Issued 21 August 1989 Resolved
MAKE PERMANENT REPAIR TO TEMPORARILY PATCHED 1" DIAMETER HOLE IN #4P WBT SIDE SHELL IN WAY OF FILL/DISCHARGE TAILPIPE SECTION.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Lifesaving
Issued 21 August 1989 Resolved
PROVIDE EVIDENCE THAT LIFEBOAT #2 HAS UNDERGONE WEIGHT TEST TO THE SAT- ISFACTION OF A COGNIZANT [name withheld] TO 31 JAN 88, OR CONDUCT SAME NOT LATER THAN 30 DEC 89.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Engineering
Issued 13 January 1989 Resolved
MAKE PERMANENT REPAIRS TO #1 FORWARD BOW THRUSTER OUTER SEAL-BOW THRUSTER NOT TO BE USED UNTIL REPAIRS ARE MADE.
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Electrical
Issued 18 July 1988 Resolved
SUBMIT FOR REVIEW BY USCG MARINE SAFETY CENTER A REVISED ELECTRICAL PLANT LOAD ANALYSIS THAT REFLECTS POWER SYSTEM MODIFICATIONS (INSTALLATION OF TWO NEW MG SETS).
Condition: Unknown
Due 18 July 1988
Resolved 18 July 1988
Deck/Cargo
Issued 31 May 1988 Resolved
MAKE PERMANENT REPAIRS TO BOW THRUSTER NO LATER THAN 30 JUNE 1988.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Lifesaving
Issued 6 February 1988 Resolved
MAKE PERMANENT REPAIR TO ACT STBD SIDE OF #2 LIFEBOAT IN WAY OF TEMPORARY RIVET REPAIR.
Condition: Unknown
Due 6 February 1988
Resolved 6 February 1988
Lifesaving
Issued 6 February 1988 Resolved
CONDUCT SUSPENSION/FLOTATION/RELEASE TEST ON #2 LIFEBOAT.
Condition: Unknown
Due 6 February 1988
Resolved 6 February 1988
Engineering
Issued 6 February 1988 Resolved
REPAIR/REPLACE NO. 4 MAIN DIESEL ENGINE STARTING MECHANISM AND PROVIDE SATISFACTORY OPERATION
Condition: Unknown
Due 6 February 1988
Resolved 6 February 1988
Engineering
Issued 17 July 1987 Resolved
REPAIR PORT MAIN SHAFT RESISTOR PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Lifesaving
Issued 8 January 1987 Resolved
REPLACE ALL OUTDATED ROCKETS TO LINE THROWING GUN.
Condition: Unknown
Due 8 January 1987
Resolved 8 January 1987
Unknown
Issued 9 August 1986 Resolved
REDESIGN RELIEF VALVES ON MISSION H.P. AIR SYSTEM AND PLACE IN PROPER OPERATION OR REMOVE THE SYSTEM FROM THE VESSEL. MISSION H.P. AIR SYSTEM IS CURRENTLY IN AN INOPERABLE CONDITION WITH SUPPLY LINES TO THE VESSEL'S BROKEN AND BLANK FLANGED. SYS NOT TO BE USED UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 9 August 1986
Resolved 9 August 1986
Electrical
Issued 9 August 1986 Resolved
PROVIDE APPROVED ELECTRICAL ONE LINE DIAGRAM AND LOAD ANALYSIS FOR ALTERATIONS TO THE SHIP'S ELECTRICAL SYSTEM.
Condition: Unknown
Due 9 August 1986
Resolved 9 August 1986
Engineering
Issued 9 August 1986 Resolved
MOUNT PRESSURE GUAGES FOR NO. 1, 2 AND 3 STARTING AIR RECEIVERS ON THE BULKHEAD OR PROVIDE SUITABLE BRACING FOR THE GUAGES. THE ABOVE ITEM TO BE COMPLETED TO THE SATISFACTION OF THE COAST GUARD INSPECTOR NOT LATER THAN 10 SEPT 1986.
Condition: Unknown
Due 9 August 1986
Resolved 9 August 1986
Electrical
Issued 1 February 1986 Resolved
DEMONSTRATE OPERATION OF GENERAL ALARM BELLS STARBOARD FORWARD OF CABLE DECK IN WEATHER (1) AND PORT SIDE AFT OF CABLE DECK IN WEATHER (1). THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 4 MARCH 1986.
Condition: Unknown
Due 1 February 1986
Resolved 1 February 1986
Fire Fighting
Issued 1 February 1986 Resolved
DEMONSTRATE OPERATION OF RELIEF VALVES ON MAGAZINE LOCKERS PRESSURE TANK. NO MATERIAL IS TO BE CARRIED IN MAGAZINES PROTECTED BY THIS SYSTEM NOR IS THE SYSTEM TO BE USED UNTIL THE RELIEF VALVE IS REPAIRED. THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 4 MARCH 1986.
Condition: Unknown
Due 1 February 1986
Resolved 1 February 1986
Engineering
Issued 1 February 1986 Resolved
DEMONSTRATE OPERATION OF RELIEF VALVES FOR MISSION AIR HIGH PRESSURE AIR RECEIVERS #1, 2, 3 AND 4. THESE AIR RECEIVERS ARE TO BE BLANKED OFF UNTIL RELIEF VALVES OPERATION ARE APPROVED. THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 4 MARCH 1986.
Condition: Unknown
Due 1 February 1986
Resolved 1 February 1986
Engineering
Issued 1 February 1986 Resolved
THE EXISTING HIGH PRESSURE MISSION AIR SYSTEM RELIEF VALVE INSTALLATION FOR#1,2,3&4 HIGH PRESSURE AIR RECEIVERS IS NOT SUITABLE AS INSTALLED. A PRO- POSED MEANS OF ENSURING THE ADEQUACY OF THE RELIEF VALVES FOR SAFE, CONSIS-TENT OPERATION IS TO BE MADE TO THIS OFFICE. (46 CFR 50.05-5A).
Condition: Unknown
Due 1 February 1986
Resolved 1 February 1986
Engineering
Issued 1 February 1986 Resolved
THE NEW COMPRESSED AIR PIPING TO STARTING AIR RECEIVERS #3, 4, AND 5 IS TO BE BLANKED OFF UNTIL A COAST GUARD APPROVED DRAWING IS PROVIDED AND IT HAS BEEN DETERMINED THAT THE AS-BUILT SYSTEM CONFORMS TO THAT DRAWING. (46 CFR56.01-10(A)). THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 4 MARCH 1986.
Condition: Unknown
Due 1 February 1986
Resolved 1 February 1986
Engineering
Issued 1 February 1986 Resolved
DEMONSTRATE OPERATION OF LOW FUEL OIL PRESSURE ALARMS FOR #1 AND #2 AUXILIARY BOILERS. (46 CFR 63.05-80). THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 4 MARCH 1986.
Condition: Unknown
Due 1 February 1986
Resolved 1 February 1986
Fire Fighting
Issued 1 February 1986 Resolved
REVISE MACHINERY SPACE HALON SYSTEM DRAWING IN HALON STORAGE ROOM ON AFT BULKHEAD AND THE HALON SYSTEM SCHEMATIC DIAGRAMS AT ALL THREE MACHINERY SPACE PULL STATIONS TO COINCIDE WITH EXISTING INSTALLATION. (46 CFR 97.37-3NVC 6-71 CHANGE ONE. THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 04MAR86.
Condition: Unknown
Due 1 February 1986
Resolved 1 February 1986
Engineering
Issued 1 February 1986 Resolved
PROVIDE PROPER SIZE RELIEF VALVES FOR NEW STARTING AIR RECEIVERS #3, 4 AND 5 PRIOR TO USING THE SYSTEM UPON COMPLETION OF ITEM E1. (46 CFR 54.01-5(D)(1)). THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 4 MARCH 1986.
Condition: Unknown
Due 1 February 1986
Resolved 1 February 1986
Lifesaving
Issued 20 June 1985 Resolved
PRIOR TO SAILING MAKE REPAIRS TO PORT MOTOR LIFEBOAT. PROVE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTION.
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985
Engineering
Issued 23 May 1985 Resolved
THE NEWLY INSTALLED START AIR RECIVERS (3) SHALL NOT BE USED FOR ANY SHIPS SYSTEM. THE SYSTEM SHALL BE MADE INOPERATIVE BY REMOVAL OF A VALVE OR INSTALLING A BLANK IN THE DISCHARGE SIDE OF THE SYSTEM.
Condition: Unknown
Due 23 May 1985
Resolved 23 May 1985
Engineering
Issued 23 May 1985 Resolved
NEW START AIR RECIVERS (3) ARE TO BE REPLACED OR REPAIRED. IF REPAIRED IT SHALL BE SHOWN THAT THEY MEET THE STANDARDS OF ASME SECTION VIII DIVISION III. ITEM E20 SHALL REMAIN OF PRESSURE UNTIL ITEM E21 IS COMPLETED.
Condition: Unknown
Due 23 May 1985
Resolved 23 May 1985
Engineering
Issued 21 May 1985 Resolved
ISSUED CG-835 ITEM E19 TO EFFECT PERM. REPAIRS TO #1 AUX BOILER AND PROVE BOILER OPERATION AND BOILER AUTOMATION TO THE SATISFACTION OT THE COGNIZANTOCMI NO LATER THAN 21JUN85.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Engineering
Issued 30 April 1985 Resolved
STARTING AIR SYSTEM SHALL NOT BE OPERATED IN EXCESS OF 250PSI UNTIL STARTING AIR RECIEVERS HAVE BEEN RE-EVALUATED AND TESTED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 30 April 1985
Resolved 30 April 1985
Engineering
Issued 29 April 1985 Resolved
STARTING AIR COMPRESSOR SYSTEM SHALL NOT BE OPERATED IN EXCESS OF 250 PSI UNTIL ITEMS 4-E AND 13-E ARE COMPLETED.
Condition: Unknown
Due 29 April 1985
Resolved 29 April 1985
Fire Fighting
Issued 27 March 1985 Resolved
ALL PENETRATIONS OF CLASS 'A' OR 'B' STRUCTURES SHALL BE MADE IN ACCORDANCEWITH THE PROVISIONS OF NVC 6-80 TO INSURE THE PROPER DEGREE OF STRUCTURAL FIRE PROCTECTION. THIS INCLUDES NEW POT. WATER FILL LINE AND CABLE RUN IN PORT 2ND DECK FAN ROOM.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Engineering
Issued 27 March 1985 Resolved
PROVIDE [name withheld] CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER FOR THE THREE NEWLY INSTALLED STARTING AIR RECEIVERS INCLUDING CALCULATIONS SHOWING MAWP BASED ON CORROSION ALLOWANCE. ALSO PROVIDE NEW MANUFACTURER'S DATA PLATE INDICATING NEW MAWP.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
SUBMIT A REVISED ONE LINE ELECTRICAL DIAGRAM AND LOAD ANALYSIS SHOWING ALL CHANGES TO SHIP'S ELECTRICAL SYSTEMS TO USCG DISTRICT 12 MMT OFFICE FOR APPROVAL.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
MAKE PERMANENT REPAIRS TO THE TWO CABLES LOCATED ON 4TH DECK AT FR 31 ON PORT SIDE IN OVERHEAD CABLE TRAY WHERE OUTER INSULATION IS CHAFFED THROUGH.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
INSTALL A DRIP SHIELD OVER THE NEW STARTING AIR COMPRESSOR CONTROLLER EN- CLOSURE.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
REPLACE STAMPED SHEET METAL 4"X4" JUNCTION BOX AT THE FORWARD SPONSOR'S L.P. AIR COMPRESSOR ON THE 2ND DECK WITH A MARINE TYPE.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Fire Fighting
Issued 27 March 1985 Resolved
AN AUDIBLE AND VISUAL ALARM SHALL BE INSTALLED ON THE BRIDGE TO INDICATE EITHER LOSS OF PRESSURE OR LOW WATER LEVEL IN THE PRESSURE TANK FOR THE MAGAZINE SPRINKLER SYSTEM PRESSURE TANK. NO EXPLOSIVES SHALL BE CARRIED IN THESE MAGAZINES UNTIL THIS ITEM IS COMPLIED WITH.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Fire Fighting
Issued 27 March 1985 Resolved
PROVIDE [name withheld] WITH A STAMPED USCG APPROVED COPY OF THE PLANS FOR THE ENGINE ROOM FIXED HALON FIREFIGHTING SYSTEM.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Fire Fighting
Issued 27 March 1985 Resolved
SUBMIT A REVISED FIRE CONTROL PLAN TO [name withheld]. THE RE- VISION SHALL INCLUDE ALL CHANGES MADE TO THE HALON SYSTEM AND TO STRUCTURALFIRE PROTECTION.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
SUBMIT A PROPOSAL, INCLUDING INTENDED COMPLETION DATE (NLT 19 MAR 86), FOR A PERMANENT MEANS TO PREVENT THE ENTRY OF WATER BY SPLASHING INTO THE 600V SWBD IN THE AFTER ENGINE ROOM FROM BELOW THE SWBD. NATIONAL ELECTRICAL CODE384-5.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
INSTALL GROUND DETECTION SYSTEMS ON THE SECONDARIES OF ALL POWER DISTRIBUT-ION AND MOTOR LOAD TRANSFORMERS NOT SO EQUIPPED AS PER 46 CFR 111.05-21(D).
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
THE 110VAC INTRUSION AND FLOODING ALARMS IN THE TWO MAGAZINES SHALL BE MADEEXPLOSION PROOF OR REMOVED FROM THESE SPACES. NO EXPLOSIVES SHALL BE CAR- RIED IN THESE MAGAZINES UNTIL THIS REQUIREMENT IS COMPLIED WITH.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
PROVIDE [name withheld] THAT ALL NEWLY INSTALLED ELECTRICAL CABLESMEET THE REQUIREMENTS OF IEEE-45, 18 OR MIL-C-915 PLUS IEEE-45,18.13.5.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
MULTI-CABLE TRANSIT DEVICE LOCATED ON BRIDGE, STBD SIDE, AT DECK SHALL BE FITTED WITH SEALING BLOCKS OF PROPER TYPE IN WAY OF NEW CABLE RUNS (2).
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
DEMONSTRATE TO THE SATISFACTION OF THE COGNIZANT OCMI THAT THE VESSEL IS FREE OF HULL CURRENT EXCEPT AS ALLOWED BY 46 CFR 111.05-11.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Lifesaving
Issued 27 March 1985 Resolved
PROVIDE STORAGE FOR EXPOSURE SUITS REQUIRED FOR WORK STATIONS AS [name withheld] PERTAINING TO NUMBER AND LOCATION.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Fire Fighting
Issued 27 March 1985 Resolved
MAKE PERMANENT REPAIRS TO RELIEF VALVE FOR AIR CHARGING REDUCING STATION AT MAGAZINE SPRINKLER TANK AND DEMONSTRATE SYSTEM TO THE SATISFACTION OF THE COGNIZANT OCMI. TO BE COMPLETED PRIOR TO STORING EXPLOSIVES IN THE MAGAZINES.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985 Resolved
UPON COMPLETION OF ITEMS 4-E AND 12-E, ALL AFFECTED AIR RECEIVERS SHALL BE HYDROED TO 125% OF MAWP AND RELIEF VALVES SET AT MAWP AND DEMONSTRATED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
STENCIL IN CONSTRASTING COLOR "DANGER-HIGH VOLTAGE" EVERY 12 FEET ON BOTH SIDES OF 440VAC MONORAIL HOIST POWER TRACK ENCLOSURE FOR ALL HOISTS THROUGHOUT VESSEL.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985

Casualty record · 23

8 February 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3144344
7 June 2010Routine · role: Involved in a Marine Casualty · activity 3774983
20 August 2010Routine · role: Involved in a Marine Casualty · activity 3839456
15 June 2013Routine · role: Involved in a Marine Casualty · activity 4739937
16 June 2013Routine · role: Involved in a Marine Casualty · activity 4952877
9 November 2013Routine · role: Involved in a Marine Casualty · activity 4767289
2 February 2014Routine · role: Involved in a Marine Casualty · activity 4793535
7 October 2014Routine · role: Involved in a Marine Casualty · activity 5011391
27 June 2015Routine · role: Involved in a Marine Casualty · 1 injured · activity 5200589
21 December 2017Routine · role: Involved in a Marine Casualty · activity 6385516
24 December 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6433447
4 January 2018Routine · role: Involved in a Marine Casualty · activity 6437526
6 June 2019Routine · role: Involved in a Marine Casualty · activity 6710719
26 June 2019Routine · role: Involved in a Marine Casualty · 1 injured · activity 6729033
30 November 2019Routine · role: Involved in a Marine Casualty · activity 6871641
10 March 2020Routine · role: Involved in a Marine Casualty · activity 6924329
28 June 2020Routine · role: Involved in a Marine Casualty · activity 6992379
23 August 2021Routine · role: Involved in a Marine Casualty · activity 7300188
2 September 2021Routine · role: Involved in a Marine Casualty · activity 7308958
31 October 2021Routine · role: Involved in a Marine Casualty · activity 7359186
1 September 2023Routine · role: Involved in a Marine Casualty · activity 7789066
8 January 2024Routine · role: Involved in a Marine Casualty · activity 7847293
14 January 2024Routine · role: Involved in a Marine Casualty · activity 7849302
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.