MAURY USCG vessel records Sign in
← All vessels

ATHENIAN BEAUTY

ATHENIAN BEAUTY is a 1983 tank ship. The Coast Guard has recorded 16 inspections since 1988, most recently in November 2001, along with 10 deficiencies — 2 with no resolution recorded — and 1 operational control.

Records from 1988 to 2001. Most recent: inspection, 30 November 2001.

Built
1983
Last inspected
30 November 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8201040 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
232218
Flag
CYPRUS
—
Maury page id
psix-232218

Inspections, by type

…with no type recorded9
…past their stated due date1
Years with a record 8 calendar years (1988–2001)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10583 - Convention (Subpart B), Net Ton
29810 - Dead Weight, Ton
17996 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

30 November 2001 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 296020
30 November 2001 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 772589
25 October 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 90157
5 May 2000 Tank Vessel Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 818570
4 January 2000 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 436187
2 May 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 428050
11 April 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 427391
2 February 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 400130
17 August 1994 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 466929
29 July 1994 Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358491
26 November 1992 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830914
3 February 1990 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 335146
3 February 1990 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1216801
13 August 1988 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 534811
13 July 1988 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 461521
13 January 1988 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036614

Deficiency record · 10

Pollution Prevention/Response › Prevention Equipment
Issued 30 November 2001 No resolution recorded
Install overfill devices that meet the requirements of 33 CFR 155.480 for each cargo tank. Specifically, the requirements found in 46 CFR 39.20-7 (b)(2), (b)(3), and (d)(1) through (d)(4). Prior to loading cargo in the U.S. LEGACY COMPONENT DESC: Overfill Devices
Condition: Unknown
Due 2 March 2002 — due date passed with no resolution recorded
Operations/Management
Issued 30 November 2001 No resolution recorded
Have cargo pump room certified gas free by a marine chemist for USCG inspection at next U.S. Port.
Action required: 15 - Rectify deficiencies by next port
Engineering
Issued 11 April 1999 Resolved
Flame screens were improper mesh in non-adherence with 46 CFR 30.10-25.
Condition: Unknown
Due 11 April 1999
Resolved 12 April 1999
Lifesaving
Issued 11 April 1999 Resolved
Ring buoy beckets deteriorated in non-adherence with SOLAS 74 (amended) III/19. Vessel required to renew or replace deteriorated ring buoys not later than 11 MAY 99.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Lifesaving
Issued 11 April 1999 Resolved
Guardrail chains in way of stbd #3 lifreaft deteriorated in non-adherence with ICLL Annex 1 Regulation 25 thereby creating increased risk of personnel falling overboard. Vessel required to replace deteriorated guardrail chains not later than 11MAY99.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Fire Fighting
Issued 11 April 1999 Resolved
Paint locker fire suppression system pressure relief valve deteriorated in non-adherence with SOLAS 74 (amended) II-2/21. Vsl required to renew or replace valve not later than 11MAY99. In lieu of renewal or replacement vsl may test valve to ensure proper functioning not later than 11MAY99.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Lifesaving
Issued 11 April 1999 Resolved
Stbd forward lifeboat sprinkler system not properly functioning in non- adherence w/SOLAS 74 (amended) III/19. Visual exam of other 3 L.B. indicatethat their sprinkler systems may not be functional. Vsl required to demon- strate proper functioning of lifeboat sprinklers to flag admin NLT 11MAY99.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Lifesaving
Issued 11 April 1999 Resolved
Auto-lowering mechanisms were removed from lifeboat systems thereby preventing coxswains from lowering lifeboats without crew assiist in non- adherence w/SOLAS 74 (amended) III/19. Vsl required to reinstall to sat offlag admin or provide sat evidence that flag admin does not require.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Electrical
Issued 11 April 1999 Resolved
Electrical light wiring stbd upper mast inboard light deteriorated in non- adherence with SOLAS 74 (amended) II-1/45.
Condition: Unknown
Due 11 April 1999
Resolved 12 April 1999
Navigation
Issued 2 February 1997 Resolved
Vessel not equipped with auto pilot alarms required by 33 CFR 157.440.
Condition: Unknown
Due 2 May 1999
Resolved 2 May 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.