MAURY USCG vessel records Sign in
← All vessels

BOHINJ

BOHINJ is a 1984 freight ship. The Coast Guard has recorded 42 inspections since 1986, most recently in March 2009, along with 42 deficiencies and 4 operational controls.

Records from 1986 to 2009. Most recent: operational control imposed, 11 March 2009.

Built
1984
Last inspected
5 March 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8112964 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
232221
Flag
LIBERIA
—
Maury page id
psix-232221

Inspections, by type

…with no type recorded34
Years with a record 22 calendar years (1986–2009)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it34941 - Dead Weight, Metric Ton
42694 - Displacement, Metric Ton
13370 - Regulatory (Subpart C or D), Net Ton
20624 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 42

5 March 2009 Ballast Water Examination · ISPS II Exam · Administrative Inspection · PII Safety Exam · ISPS III Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3427940
30 May 2006 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2664505
26 July 2005 ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2440642
26 July 2005 PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2530534
30 April 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2055967
3 October 2003 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1919959
2 October 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1922048
28 September 2003 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1915169
27 May 2003 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1803621
4 May 2002 Deficiency Check · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1612827
9 April 2002 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1602594
26 June 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 291555
18 January 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 286158
16 August 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 281210
3 August 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 280516
21 November 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 434894
5 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425811
2 October 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 420883
23 May 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 416277
15 September 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 407937
14 May 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 390962
29 December 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 386365
8 August 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 381317
8 June 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 379260
23 January 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 673331
3 January 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 373943
2 January 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 111545
23 June 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 368574
22 June 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1332532
28 March 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 365535
10 March 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 356709
5 April 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 351482
26 September 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 346174
5 April 1991 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 475952
16 July 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 338521
22 November 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 333795
31 August 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 478477
22 July 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 331487
10 December 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 327232
20 April 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 442553
5 August 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 317712
23 September 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 311455

Deficiency record · 42

Lifesaving › Launching Appliances
Issued 28 September 2003 Resolved
PORT DAVIT IS UNABLE TO RECOVER THE LIFEBOAT. REPAIR TO THE SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Davit
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 1 October 2003
Resolution: RECEIVED CLASS REPORT CLEARING SAID DEFICIENCY.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 28 May 2003 Resolved
Space containing A/C unit contained at least an inch of standing water from the leaking A/C unit. In order to use the electrical control panels for the ventilation, a crewman must be standing in water. Address electrical hazard in A/C room prior to departing Port of Tampa.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2003
Resolved 31 May 2003
Pollution Prevention/Response › Prevention Equipment
Issued 28 May 2003 Resolved
Temporary patch placed over crack in MSD Tank. Make proper repairs to the satisfaction of class/flag on the Marine Sanitation Device prior to departure Port of Tampa.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2003
Resolved 30 May 2003
Lifesaving › Lifeboat
Issued 28 May 2003 Resolved
While installing new limit switch on portside lifeboat davit, aft lifeboat falls were gouged by grinding tool. Replace wire rope, aft, on portside lifeboat to the satisfaction of class prior to departure the Port of Tampa. LEGACY COMPONENT DESC: Carriage Requirement
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2003
Resolved 31 May 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 28 May 2003 Resolved
Numerous handrails around vessel cracked and loose. Make permanent and proper repairs to the satisfaction of USCG Marine Inspector NLT 27JUN03. LEGACY COMPONENT DESC: Open Deck Space
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 28 September 2003
Engineering › Steering Gear System
Issued 9 April 2002 Resolved
Steering gear will not go to 35 starboard in bridge control. Only obtaining 32 degrees starboard. Adjust prior to 17may02. LEGACY COMPONENT DESC: Rudder Angle Indicator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 4 May 2002
Resolution: Vessel classification society recommended
Fire Fighting › Fixed Fire Detection System
Issued 9 April 2002 Resolved
Repair three fire detectors in the engine room above the evaporator, hydraulic storage tank and port side generator prior to 17May02. LEGACY COMPONENT DESC: Flame Detectors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 4 May 2002
Resolution: Inspected fire detecters and found satisfactory.
Accommodation/Occupational Safety › Occupational Safety
Issued 9 April 2002 Resolved
Repair damaged life rail in way of #3 and #2 cargo hold port side prior to 17May02. LEGACY COMPONENT DESC: Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 4 May 2002
Resolution: Inspected repair to hand rail and found satisfactory.
Construction/Loadline › Structures
Issued 9 April 2002 Resolved
Repair fractured corner bracket port side #3 cargo hold hatch combing at limber hole to the satisfaction of class prior to 17May02.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 4 May 2002
Resolution: Inspected repair and found satisfactory.
Construction/Loadline › Structures
Issued 9 April 2002 Resolved
Repair fracture port side #3 cargo hold hatch cover support to the satisfaction of class prior to 17May02.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 4 May 2002
Resolution: Received class report stating fracture was repaired with insert. Inspected repair and found satisfactory.
Construction/Loadline › Structures
Issued 9 April 2002 Resolved
Repair fracture port side #4 cargo hold hatch cover support to the satisfaction of class prior to 17May02.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 4 May 2002
Resolution: Received class report stating fracture was repaired with insert. Inspected repair and found satisfactory.
Pollution Prevention/Response › Prevention Equipment
Issued 9 April 2002 Resolved
Provide containment around the sludge discharge connection and lube oil tank vent port and starboard side to the satisfaction of class prior to 17May02. LEGACY COMPONENT DESC: Fixed Containment
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 4 May 2002
Resolution: Received class report stating new containment was constructed and welded in place.
Pollution Prevention/Response › Prevention Equipment
Issued 9 April 2002 Resolved
Provide containment around fuel oil day tank vent main deck starboard side to the satisfaction of class prior to 17May02. LEGACY COMPONENT DESC: Fixed Containment
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 4 May 2002
Resolution: Received class report stating new containment was welded to deck and found satisfactory.
Electrical › Electrical Distribution System (emergency)
Issued 9 April 2002 Resolved
Provide covers or barrier to limit access to the emergency switch board prior to 17May02. LEGACY COMPONENT DESC: Switchboard
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 4 May 2002
Resolution: Received class report attesting to proper repairs..
Electrical › Electrical Distribution System (service)
Issued 9 April 2002 Resolved
Provide covers for openings in main switch board and power panel located in after steering port side forward bulkhead prior to 17May02. LEGACY COMPONENT DESC: Switchboard
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 4 May 2002
Resolution: Received class report stating two new fiberglas covers were installed. Inspected item and found satisfactory.
Electrical › Electric Generation Source (emergency)
Issued 9 April 2002 Resolved
Emergency generator will not start . Repair or replace the air starter to the satisfaction of class prior to departing port.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2002
Resolved 18 April 2002
Resolution: Class approved repair, test sat.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 9 April 2002 Resolved
Echo sounder reported inoperative.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 April 2002
Resolved 17 April 2002
Resolution: Repaired and operating satisfactory.
Electrical
Issued 26 June 2001 Resolved
EMERGENCY GENERATOR LEAKING COOLANT EXCESSIVELY. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTING PORT OF NYC.
Condition: Unknown
Due 27 June 2001
Resolved 2 July 2001
Fire Fighting
Issued 16 August 2000 Resolved
TWO HOSES OF ALL THE FIRE HOSES ON VESSEL ARE IN GOOD CONDITION. ALL OTHER HOSES HAVE MULTIPULE HOLES IN THEM.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Fire Fighting
Issued 3 August 2000 Resolved
REPLACE HOLED FIRE HOSES IN ENGINE ROOM.
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Construction/Loadline
Issued 3 August 2000 Resolved
REPAIR FROZEN DOGS TO WATERTIGHT DOOR LEADING TO AFTER STEERING.
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Engineering
Issued 3 August 2000 Resolved
MAKE PERMANENT REPAIRS TO OILY WATER SEPARATOR WHERE NOW TEMPORARILY REPAIRED IN WAY OF CLAD WELD MAIN BODY AND HIGH LEVEL ALARM. REPAIR AT NEXTDRYDOCK.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Electrical
Issued 21 November 1999 Resolved
Provide for means to secure fuel to the emergency generator from outside the emergency generator room in accordance with SOLAS 74 II-2 Reg. 15-2.5.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Navigation
Issued 2 October 1998 Resolved
Repair inoperable gyrocompass prior to departure. 33 CFR 164.35(d)
Condition: Unknown
Due 2 October 1998
Resolved 3 October 1998
Lifesaving
Issued 2 October 1998 Resolved
Provide lifeboat launching instructions at port side boat deck prior to_x001C_ next U.S. port after sailing foreign. SOLAS 74 amd III/9.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Electrical
Issued 2 October 1998 Resolved
Install suitable guards at the back of engine control room switchboard and emergency switchboard prior to next U.S. port after sailing foreign. SOLAS_x001C_74 II-1/27.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Fire Fighting
Issued 2 October 1998 Resolved
Adjust all fire doors in main stairwell so that they close and latch properly prior to next U.S. port. SOLAS 74 II-2/51.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Engineering
Issued 2 October 1998 Resolved
Provide mechanical drain plugs for each oil containment area prior to next U.S. port after sailing foreign. 33 CFR 155.320.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Fire Fighting
Issued 29 December 1995 Resolved
REPLACE ALL ITEMS MISSING FROM THE SHIPS FIRE SUITS TO MAKE AT LEAST TWO COMPLETE SUITS PRIOR TO NEXT US PORT.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Engineering
Issued 29 December 1995 Resolved
REPAIR/REPLACE FIRE DAMPERS IN FUNNEL, AFT VENTS AND PORT AND STARBOARD VENTS TO ENGINE ROOM PRIOR TO NEXT US PORT.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Fire Fighting
Issued 29 December 1995 Resolved
PURCHASE A PORTABLE FOAM APPLICATOR UNIT FOR THE ENGINE ROOM PRIOR TO NEXT US PORT.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Lifesaving
Issued 29 December 1995 Resolved
REMOVE STARBOARD LIFERAFT HAVE REPAIR MADE TO CONTAINER PRIOR TO NEXT US PORT.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Electrical
Issued 29 December 1995 Resolved
REPAIR/REPLACE COOLING LINE TO GENERATOR IN ENGINE ROOM PRIOR TO NEXT US PORT.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Deck/Cargo
Issued 29 December 1995 Resolved
REPAIR/REPLACE LEAKS IN THE HYDRAULIC CONTROLS ON CARGO HOLDS 1-3 PRIOR TO NEXT US PORT, OR HAVE CLASS INSPECT PRIOR TO RETURNING.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Fire Fighting
Issued 29 December 1995 Resolved
REPAIR/REPLACE VENT DUCTS IN THE ENGINE ROOM PRIOR TO NEXT US PORT, OR HAVECLASS INSPECT PRIOR TO RETURNING.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Fire Fighting
Issued 29 December 1995 Resolved
INSPECT ALL HOSES AND FIRE STATIONS TO INSURE ALL CONNECTIONS CAN BE PROPERLY MADE AND THAT THERE ARE NO LEAKING HOSES. REPAIR/REPLACE ANY DAMAGED ITEMS PRIOR TO NEXT US PORT.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Unknown
Issued 3 January 1995 Resolved
VESSELS MSD WAS NOT PLACARDED OR LABELED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 August 1995
Resolved 18 August 1995
Engineering
Issued 28 March 1994 Resolved
OIL XFER PROCEDURES NOT CROSS REFERENCED, ONE ITEM OUT OF ORDER, CORRECTED ON THE SPOT.
Condition: Unknown
Due 29 March 1994
Resolved 8 April 1994
Documentation
Issued 5 April 1992 Resolved
APHIS BOARDING OFFICER QUESTIONED WHETHER THE PLASTICS ONBOARD_x001C_ WERE INCINERATED WHEN NECESSARY OR DISCHARGED OVERBOARD. MASTER WAS NOT FAMILIAR WITH GARBAGE DISPOSAL PROCEDURES DURING THE APHIS BOARDING. VESSEL WAS NOT BOARDED BY CG.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Navigation
Issued 10 December 1988 Resolved
CHART 18720, 18740, 18746, 18749, AND 18751 ONBOARD BUT NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33.
Condition: Unknown
Due 12 December 1988
Resolved 10 December 1988
Documentation
Issued 10 December 1988 Resolved
OIL TRANSFER PROCEDURES DESCRIBED BY 33CFR155.750 AND REQUIRED BY 33CFR155.720 NOT ONBOARD.
Condition: Unknown
Due 10 December 1988
Resolved 10 December 1988
Navigation
Issued 10 December 1988 Resolved
U.S. COAST GUARD LIGHT LIST ONBOARD BUT NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33.
Condition: Unknown
Due 12 December 1988
Resolved 10 December 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.