SWIFT

SWIFT is a 1983 freight ship. The Coast Guard has recorded 3 inspections since 2016, most recently in August 2017, along with 3 deficiencies — 2 with no resolution recorded —.

Records from 2016 to 2017. Most recent: inspection, 5 August 2017.

Built
1983
Last inspected
5 August 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 August 2017
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8113554
232292
Flag
CURACAO
Maury page id
psix-232292

Documentation record

Tonnage as PSIX records it9573 - Convention (Subpart B), Net Ton
29590 - Dead Weight, Ton
41297 - Displacement, Ton
22835 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

3 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

5 August 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6230970
3 August 2017 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6217996
18 August 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5976110

Deficiency record · 3

Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 August 2017 No resolution recorded
General arrangement plans shall be permenantly exhibited...showing clearly...particulars of the fire detection and fire alarm systems. PSCO observed 4 detectors in the engine room that do not match what is posted on approved fire control plan and fire detection system index on bridge. 74 SOLAS (2014 con)II-2/15.2.4.1
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Cylinder Head
Issued 3 August 2017 No resolution recorded
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations. #1 ships service generator has severe jacket water leak from #6 cylinder. PSCO observed 3 rags stuffed around the cylinder. 74SOLAS(2014 con)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Generator (propulsion-electric) › Battery
Issued 3 August 2017 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations. The PSCO observed emergency generatorwould not start on #1 battery which was online battery for automatic start mode. 74SOLAS(2014 con)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 3 August 2017
Resolution: Vessel was able to demonstrate proper operation of the emergency generator by replacing both starting batteries and demonstrating the emergency generator starting on each battery.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.