MAURY USCG vessel records Sign in
← All vessels

MSC TAMPA

MSC TAMPA is a 1984 freight ship. The Coast Guard has recorded 42 inspections since 1984, most recently in December 2008, along with 24 deficiencies and 5 operational controls.

Records from 1984 to 2008. Most recent: inspection, 15 December 2008.

Built
1984
Last inspected
15 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8300133 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
232412
Flag
DENMARK
—
Maury page id
psix-232412

Inspections, by type

…with no type recorded32
Years with a record 14 calendar years (1984–2008)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it43332 - Regulatory (Subpart C or D), Gross Ton
53325 - Dead Weight, Ton
18642 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 42

15 December 2008 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3380234
30 November 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3371383
24 November 2008 PII Safety Exam · ISM Exam · Loadline Exam · Administrative Inspection · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3368615
21 October 2008 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3348603
9 June 2008 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3231767
28 April 2008 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3194354
19 November 2007 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3101143
2 October 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3071575
2 October 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3071724
20 April 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2911735
13 April 2007 Ballast Water Examination · PII Safety Exam · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2907093
18 January 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 478738
16 January 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 23993
15 January 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 56403
15 January 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 500477
16 December 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 154385
14 December 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 435797
19 April 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 427741
17 December 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 423662
2 March 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 413322
1 June 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 351085
22 February 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 348910
14 June 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 344391
12 May 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 506985
4 October 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 339689
21 April 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 467685
17 November 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 333723
1 October 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 332812
10 February 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 328384
25 December 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 327580
26 August 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 325290
16 April 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 445640
20 August 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 318001
2 February 1987 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 465118
28 July 1986 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 310455
28 July 1986 Control Verification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1318813
24 March 1986 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 456891
21 March 1986 Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1295726
27 September 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 534925
7 May 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 301844
17 November 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 537228
1 November 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 298706

Deficiency record · 24

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 November 2008 Resolved
An intermediate overboard valve in between the overboard skin valve and the OWS remained open when put in the closed position. This was determined due to salt water being discharged from the IMO test port after the closing of the 3 way valve. The OWS function is not affected and works fine. Class to attest to proper repairs of the system(valve) within 14 days. SOLAS 74 Ch I Reg 11
Action required: 705 - Other - as specified
Due 14 December 2008
Resolved 15 December 2008
Resolution: Received class report attesting to proper repairs.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 21 October 2008 Resolved
SOLAS74CH3 Reg12 During lifeboat inspections PSCO's discovered that all lifeboat equipment except food and water was located on the bridge and not in the life boats. The master stated it was common practice to keep all life boat equipment on the bridge, storage location to be approved by class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received class report attesting to proper repairs, see report in documents for details.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 21 October 2008 Resolved
SOLAS 74 CH3 Reg IIa(xii) PSCO's discovered 06 food rations wasted during lifeboat examination; the required # of food rations to be on each lifeboat is 40. When the receptacle containing the food rations was opened. PSCO's observed a large amount of water pouring from it. Food rations are required to kept in airtight container. To the satisfaction of Class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received class report attesting to proper repairs, see report in documents for details.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 October 2008 Resolved
Cooling water piping on multiple systems including shaft bearings, fresh water generator, jacket cooling water piping, main sea water return line, main engine scavenge air cooler, low temp small coolers, diesel generators, reefer compressor and outboard main engine jacket cooler were found to have corrosion spots with salt build up and rust indicating leakage. Class to attest to repairs. Solas 74
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received class report attesting to proper repairs, see report in documents for details.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 21 October 2008 Resolved
74 SOLAS (2004 Cons) CH3 Reg 20.2 PSCO's observed 03 torn lifejackets with internal flotation medium exposed, as well as 03 life jacket lights found to be extinguished. All lifesaving appliances shall be in working order to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received class report attesting to proper repairs, see report in documents for details.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 21 October 2008 Resolved
SOLAS 74 ChII-2 Reg 14(a) During fire drill , PSCO's discovered one of the primary fire fighting suits to have a significant tear of over 02 inches on the back of the suit just below the collar. Class to attest to adequate condition of all fire suits on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received class report attesting to proper repairs, see report in documents for details.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 21 October 2008 Resolved
Based on the multiple items found during the course of the inspection it is recommended that the company conduct an internal audit of the SMS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received audit report, see report in documents for details.
Lifesaving › Inflatable Liferafts › Approval
Issued 21 October 2008 Resolved
74 SOLAS (2004 Cons) Ch1 Reg 11 b the vessel's SEC certificate specifies that 03 liferafts are onboard; 01 six man forward, 01 twenty man and 01 25 man. the vessel actually has 01 10 man liferaft forward 01 ten man liferaft aft and 01 25 man life raft on each side. Class to verify life raft arrangements.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received class report attesting to proper repairs, see report in documents for details.
Lifesaving › Liferaft Equipment › Food Ration
Issued 21 October 2008 Resolved
74SOLAS (2004 Cons) CH3 Reg 20.2 PSCO's observed watertight receptacle containing the food rations for the life boat to be heavily painted, including the securing latches for the lid. monthly checks of the life boat equipment are required to be conducted; however the condition of the container and wasted food rations inside. indicate the monthly checks are not being conducted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received class report attesting to proper repairs, see report in documents for details.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 October 2008 Resolved
Provision crane on deck is leaking hydraulic oil creating a slip/trip/fall hazard. Class to attest to proper repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received class report attesting to proper repairs, see report in documents for details. A condition of class was issued for permanent repair.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 21 October 2008 Resolved
74 SOLAS CH1Reg11 while conducting steering gear test PSCO’s observed the rudder hunting 1-2 degrees when brought to amidships on the #1 steering pump. There also was excessive hydraulic oil on the steering gear assembly. Class surveyor to attest to proper repairs and operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2008
Resolution: Received technicians report as well as class surveyors report attesting that proper repairs will be made no later than January 09.
Engineering › Sea-water System (primary cooling) › Pump
Issued 21 October 2008 Resolved
#2 ballast pump and #1 auxiliary sea water cooling pump is leaking water. Corrosion, rust, and salt build up was found on the #2 main engine jacket water pump indicating that it was also leaking. Class to attest to repair and operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received class report attesting to proper repairs, see report in documents for details.
Engineering › Fuel Oil Service System › Pump
Issued 21 October 2008 Resolved
Booster pump for the #1 fuel oil purifier is leaking. Excessive oil is in the purifier room as a result. Class to attest to repair and oil clean up.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received class report attesting to proper repairs, see report in documents for details.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 21 October 2008 Resolved
Vessel's #1 fuel tank is leaking fuel oil into the #1 cargo hold due to wastage in the tank top.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2008
Resolution: Received class report attesting to temporary repairs with a condition of class for permanent repairs prior to 25NOV08, see report in documents for details.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 28 April 2008 Resolved
Hole found in the starboard fuel tank between holds 4/5.
Due 28 May 2008
Resolved 9 June 2008
Resolution: Received class report clearing above deficiency.
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 October 2007 Resolved
Issued LOD 31-07 for inoperable primary radar. Equipment shall be repaired prior to departing the Port of Baltimore and copy of tech. report will be faxed to this office.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2007
Resolution: Received tech report attesting to repair/operation of radar equipment.
Navigation
Issued 4 October 1990 Resolved
Vessel's C.G. Light List, required by 33 CFR 164.33(a)(2)(ii), for the areato be transited was not corrected through the latest Notice to Mariners.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Navigation
Issued 4 October 1990 Resolved
Vessel failed to meet the requirements of 33 CFR 164.53.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Navigation
Issued 1 October 1989 Resolved
U.S. COAST PILOT OR EQUIVALENT NOT ON BOARD FOR CG INSPECTION.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Documentation
Issued 26 August 1988 Resolved
OIL TRANSFER PROCEDURES MISSING PROCEDURES FOR EMERGENCY SHUTDOWN.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Documentation
Issued 26 August 1988 Resolved
OIL TRANSFER PROCEDURES MISSING THE NUMBER OF PERSONS REQUIRED.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Documentation
Issued 26 August 1988 Resolved
OIL TRANSFER PROCEDURES MISSING PROCEDURES FOR TOPPING OFF TANKS.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Documentation
Issued 26 August 1988 Resolved
OIL RECORD BOOK NOT PROPERLY MAINTAINED.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Documentation
Issued 26 August 1988 Resolved
IMPROPER SHIPPING NAME ON DANGEROUS CARGO MANIFEST. DCM LISTED 1:HELIUM LIQUID, 2:FLAMMABLE LIQUID CNTG MINERAL SPIRITS. NAMES SHOULD HAVE BEEN LISTED AS 1:HELIUM REFRIGERATED LIQUID, 2:FLAMMABLE LIQUID NOS(CNTG MINERALSPIRITS)
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.