M/V INDIAN RIVER QUEEN

M/V INDIAN RIVER QUEEN is a 1984 passenger vessel (inspected). The Coast Guard has recorded 92 inspections since 1985, most recently in January 2026, along with 204 deficiencies and 2 operational controls.

Records from 1985 to 2026. Most recent: inspection, 21 January 2026.

Built
1984
Last inspected
21 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC2179
232595
Flag
UNITED STATES
366989070
Maury page id
psix-232595

Inspections, by type

…with no type recorded10
Years with a record 41 calendar years (1985–2026)
The 92 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)79.2 ft × 23.0 ft × 6.0 ft
Registered tonnagegross 88 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderT.D. VINETTE COMPANY · ESCANABA, MI, UNITED STATES · built 1984
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCOCOA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Regulatory (Subpart C or D), Net Ton
96 - Dead Weight, Ton
88 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC2179MMSI 366989070 · active · compulsorily equipped · granted 8 October 2024, expires 9 November 2034
WCY7283MMSI not assigned · expired · compulsorily equipped · granted 13 October 1998, cancelled 13 December 2008 · licensed under a name not among this hull’s recorded names (not shown)
WCE3758MMSI not assigned · expired · voluntarily equipped · granted 7 March 1994, cancelled 16 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 92

21 January 2026 Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8299677
29 July 2025 Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8197574
24 October 2024 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8023947
14 March 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7879152
15 February 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7868275
1 September 2023 Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7782271
8 June 2023 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7705019
8 February 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7612572
15 February 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7396454
25 August 2021 Administrative Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7296000
4 February 2021 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7135571
29 May 2020 Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6992864
19 November 2019 MTSA Verification · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6854057
23 January 2019 Deficiency Check · MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6616224
2 August 2018 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6499829
12 January 2018 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6337050
29 November 2017 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6315012
3 January 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6064889
30 November 2016 Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6050124
3 August 2016 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5982247
11 January 2016 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5794928
4 January 2016 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5790335
23 December 2015 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5873397
24 November 2015 DAPI Audit · MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5769760
7 August 2014 Damage Survey
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4947970
7 August 2014 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4967730
6 January 2012 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4221432
2 February 2011 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3946694
11 January 2011 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3926148
5 January 2010 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3658813
20 March 2009 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3437184
27 February 2009 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3425208
18 February 2009 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3419729
13 February 2009 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3417410
7 January 2008 Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3125844
20 December 2007 Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3118837
7 March 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2884179
31 January 2007 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2863992
27 March 2006 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2624023
31 January 2006 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2576540
27 April 2005 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2344048
4 January 2005 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2268608
3 December 2004 MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2252525
15 November 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2241419
13 January 2004 Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1986796
16 May 2003 Construction Oversight · COI Inspection · Deadweight Survey · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1794798
26 February 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1489360
6 November 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1415728
4 October 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1465699
30 May 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1066099
18 January 2001 Re-Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1361875
4 February 2000 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 813977
13 January 2000 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1444265
9 December 1999 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1384328
18 August 1999 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 778752
14 August 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 109254
20 July 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1095820
1 June 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 643005
14 April 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 788982
12 March 1999 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1399066
22 February 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 798124
15 June 1998 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1471345
27 May 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1126562
14 May 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 790425
20 February 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 782876
28 January 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 782252
6 October 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1383681
29 January 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1097173
19 December 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1097156
15 May 1996 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1088204
16 February 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1191027
21 December 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 872399
12 September 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 882499
24 April 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 860042
13 February 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 841594
23 December 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1164927
7 February 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 851917
8 January 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1448458
3 September 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 857897
24 May 1993 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 828941
5 January 1993 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 832289
23 January 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1259945
13 December 1991 Hull Examination · COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 938867
3 May 1991 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 915134
2 July 1990 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 930657
4 May 1990 Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 904141
4 May 1990 COI Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1214496
20 April 1989 Hull Examination · COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1043281
12 April 1988 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1030916
20 April 1987 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1312752
21 April 1986 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1307343
15 April 1985 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1289281

Deficiency record · 204

10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 6 November 2024 Resolved
Vessels are required to display navigation lights for the vessels size. The stern light is inoperable. Correct prior to operating at night or in periods of restricted visibility.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2024
Resolved 26 August 2025
Resolution: Attending MI witnessed repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 November 2024 Resolved
Life ring buoys must be ready for deployment and suitable for service. The grab line on one buoy is wasted and retro-reflective tape is missing from two life ring buoys. Correct prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 26 August 2025
Resolution: Attending MI witnessed repair.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 November 2024 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system. (5) A paint locker. Vessel has manufactured paint locker in the water/fuel tank compartment aft of the engine room. Remove all paints to a proper flammable storage locker above deck or install a fixed fire extinguishing system to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2024
Resolved 26 August 2025
Resolution: Paint removed from void, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2024 Resolved
Shutoff valves, installed to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferable from an accessible position on the weather deck. The vessel had two fuel oil lines coming from the fuel tank. Once had a remote valve closure from the weather deck the other valve is missing the remote closure. Install to the satisfaction of the attending [name withheld] fuel valve must be kept in the closed position until this is corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2024
Resolved 26 August 2025
Resolution: Operator permanently closed the second supply valve. BMDE’s and BSSDG’s are fed from the line that has the remote closing device
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 6 November 2024 Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard or rail. The shafts in the water/fuel tank space do not currently have guards in place over them as in the liquor locker space. Install guards over the shafts to the satisfaction of the attending MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2024
Resolved 27 August 2025
Resolution: Operator installed guards around shaft area.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 February 2024 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel has a deep sink port side aft that is not attached to the bulkhead and gives way when pulled on. Repair to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2024
Resolved 14 March 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 February 2024 Resolved
Nonmetallic piping materials, including nonmetallic flexible hose assemblies mut meet the requirements of 46 CFR 56.60-25 in subchapter F of this chapter. The potable water supply line running through the lazarette up to the aft port side kitchenette is dripping water at the deck penetration. The piping goes from PVC to metal nipple back to PVC. Repair to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2024
Resolved 14 March 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 February 2024 Resolved
All unfired pressure vessels must be installed to the satisfaction of the OCMI. The small air compressor in the engine room is sitting up on a shelf with no means to prevent it from falling while underway. Secure for sea to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2024
Resolved 14 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 February 2024 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacture must be fitted in fuel supply line in the engine compartment. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. 03 fuel oil filters in the engine room do not have flame impingement bowls on them. Add flame impingement bowls or prove the manufacture does not require them to the satisfaction of the attending MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2024
Resolved 14 March 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol test kits were not onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2024
Resolved 14 March 2024
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 February 2024 Resolved
50% of the crew must possess valid first aid / CPR cards. First aid cards for the crew were expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2024
Resolved 14 March 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 8 June 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant OCMI. The fwd and aft escape hatches in the engine room are not marked on both sides. Mark both hatches appropriately as stated above.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 24 October 2023
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 February 2023 Resolved
The following vessels must have on board a properly installed, operational Coast Guard approved AIS Class A device: A self-propelled vessel that is certificated to carry more than 150 passengers. Vessel's AIS exception has expired and vessel currently does not have a AIS installed. Install and prove proper operation of AIS Class A device.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 8 June 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 February 2023 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel does not have a valid safety radio certificate. Provide valid safety radio certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 8 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 November 2019 Resolved
Demonstrate operation of electric fire pump, providing at least 50 psi with a single hydrant open.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2019
Resolved 22 November 2019
Resolution: Cleaned impellor, pressure now 70 psi
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2019 Resolved
Reduce, remove, reroute extension cords & surge protectors when re-building PA/Stereo cabinet above stairway to bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 9 December 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 November 2019 Resolved
Ensure fuel tank vent is installed with a flame screen.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 9 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 19 November 2019 Resolved
Extend the machinery guards on each engine/rotating machinery to cover hazard adequately.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 9 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 November 2019 Resolved
Outfit ring life buoys as prescribed on the COI; 1 w/line, 1 w/light, and 1 w/neither.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 9 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2019 Resolved
Provide current proof of enrollment in drus consortium and provide annual MIS report.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2019
Resolved 31 January 2019
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2019 Resolved
Renew grab lines on upper deck ring bouy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2019
Resolved 31 January 2019
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2019 Resolved
Renew retroreflective tape on PFD's identified during inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2019
Resolved 31 January 2019
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 January 2019 Resolved
Provide faceplate cover on upper deck bar receptacle.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2019
Resolved 31 January 2019
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 January 2019 Resolved
Repair and prove proper operation of bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2019
Resolved 31 January 2019
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 January 2019 Resolved
Renew fire detection system sensor in engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2019
Resolved 31 January 2019
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 29 November 2017 Resolved
Properly label circuit breakers for main saloon panel in engineroom and verify circuit breakers are sized correctly.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 12 January 2018
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 November 2017 Resolved
Install belt guard over main generator alternator belt and drive.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 12 January 2018
Resolution: Corrected
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 29 November 2017 Resolved
Remove oil soaked SFP insulation in fwd eng overhead IWO main generator crankcase breather and replace with approved insulation
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 12 January 2018
Resolution: corrected
Construction/Loadline › Penetrations › Pipe Flange
Issued 29 November 2017 Resolved
Properly seal bulkhead penetration in aft bulkhead of water tank storage space.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 12 January 2018
Resolution: corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 November 2017 Resolved
Provide proper 1st aid kit.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 12 January 2018
Resolution: corrected
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 November 2016 Resolved
Repair port and starboard running lights prior to operating at night but NLT 30DEC16.
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 3 January 2017
Resolution: corrected
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 November 2016 Resolved
Hydrostatically test (3) CO2 bottles for the engine room system and provide report.
Action required: 705 - Other - as specified
Due 4 January 2017
Resolved 3 January 2017
Resolution: corrected
Lifesaving › Hand Flares › Quantity
Issued 30 November 2016 Resolved
Provide (3) additional orange smoke or red hand flares prior to operating.
Due 30 November 2016
Resolved 30 November 2016
Resolution: flares were purchased and placed onboard prior to completion of the inspection
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 November 2016 Resolved
Provide cover for 110 VDC outlet and cover for exposed light in the upper deck bar.
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 3 January 2017
Resolution: corrected
Fire Fighting › Fire Main › Valves
Issued 30 November 2016 Resolved
Repack fire main valve #7 located in engine room.
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 3 January 2017
Resolution: corrected
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 24 November 2015 Resolved
Provide Marine Operator Permit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 23 December 2015
Documentation › Markings/Placards › Warning Signs
Issued 24 November 2015 Resolved
Provide emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 23 December 2015
Documentation › Markings/Placards › Warning Signs
Issued 24 November 2015 Resolved
Provide and post emergecny instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 23 December 2015
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 November 2015 Resolved
Prove proper operation of the E light on the second deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 23 December 2015
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 November 2015 Resolved
Renew lifeline and provide clip for ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 23 December 2015
Construction/Loadline › Structures › Superstructure
Issued 24 November 2015 Resolved
Renew deck support IWO starboard side deck 2 bar at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 3 January 2017
Resolution: corrected
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 November 2015 Resolved
Repair / replace J Box at deck one port side aft stairwell.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 23 December 2015
Engineering › Bilge Water Management System › Piping
Issued 24 November 2015 Resolved
Install pipe hangers for hydraulic lines in MSD spce.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 23 December 2015
Fire Fighting › Fire Pumps › Pressure
Issued 24 November 2015 Resolved
Prove proper operation of engine driven fire pump pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 23 December 2015
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 24 November 2015 Resolved
Prove proper operation of port engine gauges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 23 December 2015
Construction/Loadline › Hull › Bottom Plating
Issued 7 August 2014 Resolved
Vessel operator shall provide dive survey report attesting to the condition of the hull plating for continued service, post grounding, prior to operating.
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 13 August 2014
Resolution: Received dive survey report - all sat. Requirement cleared.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 January 2011 Resolved
Prior to operating at night or in periods of reduced visibility, prove proper operation of the starboard sidelight.
Action required: 705 - Other - as specified
Due 11 February 2011
Resolved 2 February 2011
Documentation › Markings/Placards › Warning Signs
Issued 11 January 2011 Resolved
Post emergency broadcast placard IAW 46CFR121.506.
Action required: 705 - Other - as specified
Due 11 February 2011
Resolved 16 February 2011
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 11 January 2011 Resolved
Make permanent repairs to the starboard aft main door where wasted.
Action required: 705 - Other - as specified
Due 11 February 2011
Resolved 2 February 2011
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 January 2011 Resolved
Mount plug to air compressor.
Action required: 705 - Other - as specified
Due 11 February 2011
Resolved 2 February 2011
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 January 2011 Resolved
Install covers in blanks in power panel #3 and the power panel in the F/O tank room.
Action required: 705 - Other - as specified
Due 11 February 2011
Resolved 2 February 2011
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 13 February 2009 Resolved
Post sign on port main deck aft door notifying passengers not open door when underway.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 27 February 2009
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 13 February 2009 Resolved
Place electrical outlets on upper bar area on GFCI.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 20 March 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 February 2009 Resolved
Repair exhaust leak on port main diesel engine.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 20 March 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 13 February 2009 Resolved
Provide operable water temperature gauge for port main diesl engine.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 20 March 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 February 2009 Resolved
Provide CG approved first aid kit.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 20 March 2009
Documentation › Certificates/Documents › FCC SSL
Issued 13 February 2009 Resolved
Provide FCC Marine Operator permit and FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 27 February 2009
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 February 2009 Resolved
Prove crew is enrolled in drug testing program.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 18 February 2009
Resolution: Rcvd copy of crew enrollment in DAPI program while conducting inspection on the M/V SUNSHINE.
Lifesaving › Hand Flares › Quantity
Issued 13 February 2009 Resolved
Provide three orange distress flares (or substitution).
Action required: 705 - Other - as specified
Due 13 February 2009
Resolved 18 February 2009
Resolution: Rcvd copy of recpt for flares purchased this date.
Construction/Loadline › Hull › Bottom Plating
Issued 7 January 2008 Resolved
Crop and renew three areas on hull at next dry dock. Area under port and starboard bow, starting six feet back from stem and from keel 2.5 feet up; under starboard fuel tank 4 feet x 4 feet; and under sewage tank 70 inch wide x 45 inch long.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2010
Resolved 12 February 2010
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 20 December 2007 Resolved
See (10) item worklist attached to this activity.
Action required: 705 - Other - as specified
Due 31 January 2008
Resolved 22 January 2008
Engineering › Bilge Water Management System › Strainer
Issued 31 January 2007 Resolved
Strainer for the bilge suction line in the #2 compartment was found wasted. Strainer is required to be renewed.
Action required: 705 - Other - as specified
Due 28 February 2007
Resolved 7 March 2007
Resolution: Completed.
Fire Fighting › Fire Hoses › Condition
Issued 31 January 2007 Resolved
Fire hose on the 02 deck was found to be holed and leaking during testing. Hose is required to be renewed.
Action required: 705 - Other - as specified
Due 28 February 2007
Resolved 7 March 2007
Resolution: Completed.
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2007 Resolved
Vessel is required to undergo a complete hull and internal structural examination NLT 31JAN08 - see narrative for details.
Action required: 705 - Other - as specified
Due 31 January 2008
Resolved 7 March 2007
Resolution: Cleared (see letter MSD 07-009 in vessel''s file).
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 January 2007 Resolved
Vessel is to install a plug in the missing electrical junction box located on the main deck aft.
Action required: 705 - Other - as specified
Due 28 February 2007
Resolved 7 March 2007
Resolution: Completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 January 2007 Resolved
Vessel is to reattach the unsecured wiring on the 01 deck overhead with proper metal fastenings.
Action required: 705 - Other - as specified
Due 28 February 2007
Resolved 7 March 2007
Resolution: Completed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 January 2007 Resolved
Vessel is to install proper 4" rail courses for the rails located in the passenger area on the bow. Additionally, rails are to be provided IWO openings on the port and starboard sides of the same area.
Action required: 705 - Other - as specified
Due 28 February 2007
Resolved 7 March 2007
Resolution: Completed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 27 March 2006 Resolved
Provide USCG Marine Safety Center approval for revisions noted in "as built" drawings for wastewater treatment system.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 13 November 2006
Resolution: Completed.
Lifesaving › Hand Flares › Expired
Issued 31 January 2006 Resolved
Renew 2 orange smoke flares.
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 27 February 2006
Resolution: Completed.
Engineering › Fuel Oil Service System › Valve
Issued 31 January 2006 Resolved
Renew handle for emergency fuel shutoff valve.
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 27 February 2006
Resolution: Completed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 31 January 2006 Resolved
Provide proof of current enrollment in a drug testing program.
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 27 February 2006
Resolution: Completed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 January 2006 Resolved
Properly install machinery guards on both propulsion engines.
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 27 February 2006
Resolution: Completed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 January 2006 Resolved
Properly install shaft guards in both dry storage compartments.
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 27 February 2006
Resolution: Completed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 31 January 2006 Resolved
Conduct fire and man overboard drills in the presence of a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 27 February 2006
Resolution: Completed.
Documentation › Markings/Placards › Warning Signs
Issued 24 November 2004 Resolved
17.Post emergency evacuation & fire control plans.
Condition: Unknown
Due 24 November 2004
Resolved 24 November 2004
Resolution: Corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 November 2004 Resolved
1.Complete fixed CO2 system installation & test. Test must be witnessed & approved by a CG marine Inspector. Provide copies of approved plans from MSC.
Condition: Unknown
Due 1 December 2004
Resolved 5 December 2004
Electrical › Electric Generation Source (service) › Power Requirement
Issued 22 November 2004 Resolved
2.Complete emergency generator installation & make available for inspection.
Due 22 December 2004
Resolved 4 January 2005
Resolution: Corrected.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 22 November 2004 Resolved
3.Complete heat detector installation in engine room & make available for inspection.
Due 24 November 2004
Resolved 24 November 2004
Resolution: Corrected.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 November 2004 Resolved
4.Demonstrate automatic closure of A-60 fire doors.
Condition: Improper Installation
Due 24 November 2004
Resolved 24 November 2004
Resolution: Corrected.
Fire Fighting › Fire Pumps › Pumpshaft
Issued 22 November 2004 Resolved
5.Install a guard over the engine driven fire/bilge pumps pulley assembly.
Condition: Improper Installation
Due 22 December 2004
Resolved 4 January 2005
Resolution: Corrected.
Fire Fighting › Fire Main › Valves
Issued 22 November 2004 Resolved
6.Repair leaks on the main deck fire stations valve stem and the starboard side over board valves stem in the fire/bilge system.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 4 January 2005
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Cable
Issued 22 November 2004 Resolved
7.Remove dead end wires from in front of the pilothouse.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 5 December 2004
Engineering › Thrusters › Piping
Issued 22 November 2004 Resolved
8.Repair leaks on the bow thruster system. (Numerous small leaks were noted)
Condition: Improper Installation
Due 22 December 2004
Resolved 27 April 2005
Resolution: Corrected.
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 22 November 2004 Resolved
9.Provide documentation that 50% of crew is First Aid/CPR certified.
Condition: Placed in Improper Service
Due 22 December 2004
Resolved 27 April 2005
Resolution: Corrected.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 22 November 2004 Resolved
10.Provide documentation that crew is enrolled in an annual drug program.
Condition: Unknown
Due 22 December 2004
Resolved 30 November 2004
Resolution: Corrected.
Navigation › Piloting/Steering › US Coast Pilot
Issued 22 November 2004 Resolved
11.Provide a U.S. Coast Pilot booklet.
Condition: Unknown
Due 22 December 2004
Resolved 27 April 2005
Resolution: Corrected.
Communications › Audible Communications › Bell
Issued 22 November 2004 Resolved
12.Provide a proper sized bell for the pilothouse.
Condition: Unknown
Due 22 December 2004
Resolved 24 November 2004
Resolution: Corrected.
Communications › Radio Communications › VHF Radiotelephone
Issued 22 November 2004 Resolved
13.Post emergency broadcast placard.
Condition: Unknown
Due 24 November 2004
Resolved 24 November 2004
Resolution: Corrected.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 22 November 2004 Resolved
14.Repaint aft draft markings.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 5 December 2004
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 22 November 2004 Resolved
14.Repaint aft draft markings.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 2 December 2004
Resolution: Def entered twice.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 November 2004 Resolved
15.Provide documentation that ceiling panels are fire resistant.
Condition: Unknown
Due 22 December 2004
Resolved 30 November 2004
Resolution: Corrected.
Communications › Visual Communication › Warning Sign (gangway)
Issued 22 November 2004 Resolved
16.Mark upper decks for maximum number of passengers allowed.
Condition: Unknown
Due 24 November 2004
Resolved 24 November 2004
Resolution: Corrected.
Documentation › Markings/Placards › Warning Signs
Issued 22 November 2004 Resolved
18.Post life jacket donning procedures.
Condition: Unknown
Due 24 November 2004
Resolved 24 November 2004
Resolution: Corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 November 2004 Resolved
19.Install automatic damper for the engine room.
Condition: Placed in Improper Service
Due 22 December 2004
Resolved 4 January 2005
Resolution: Corrected.
Engineering › Bilge Water Management System › Interface Detector
Issued 22 November 2004 Resolved
20.Repair sewage compartment bilge high-level alarm.
Condition: Improper/Lack of Maintenance
Due 24 November 2004
Resolved 24 November 2004
Resolution: Corrected.
Engineering › Fuel Oil Service System › Filter
Issued 22 November 2004 Resolved
21.Provide flame shields for all plastic bowl fuel filters.
Condition: Placed in Improper Service
Due 22 December 2004
Resolved 4 January 2005
Resolution: Corrected.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 22 November 2004 Resolved
22.Install 30 x 30 mesh screens in both fuel vents.
Condition: Placed in Improper Service
Due 24 November 2004
Resolved 24 November 2004
Resolution: Corrected.
Electrical › Electric Supply System (service) › Cable
Issued 22 November 2004 Resolved
23.Install a proper shore tie connection.
Condition: Placed in Improper Service
Due 22 December 2004
Resolved 5 December 2004
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 22 November 2004 Resolved
24.Resubmit two copies of electrical drawing to MSC for stamp approval.
Condition: Unknown
Due 22 December 2004
Resolved 27 April 2005
Resolution: Corrected.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 22 November 2004 Resolved
25.Resubmit & provide sanitary piping, structural fire protection, bow thruster & fresh/potable water piping plans to MSC for approval.
Condition: Unknown
Due 22 December 2004
Resolved 27 April 2005
Resolution: Corrected.
Documentation › Certificates/Documents › Stability Letter
Issued 22 November 2004 Resolved
26.Provide copy of approved stability letter from MSC.
Condition: Unknown
Due 22 December 2004
Resolved 30 November 2004
Resolution: Corrected.
Construction/Loadline
Issued 18 January 2001 Resolved
Crop and renew four (4) upper deck supports located on the bow.
Condition: Unknown
Due 12 February 2001
Resolved 31 May 2001
Construction/Loadline
Issued 18 January 2001 Resolved
Crop and renew stbd side upper deck supports # 5, 7, and 10 located on second deck # bow to stern.
Condition: Unknown
Due 12 February 2001
Resolved 31 May 2001
Construction/Loadline
Issued 18 January 2001 Resolved
Crop and renew portside upper deck supports # 7, 9, and 11 located on second deck # bow to stern.
Condition: Unknown
Due 12 February 2001
Resolved 31 May 2001
Construction/Loadline › Hull › Bracket
Issued 18 January 2001 Resolved
Crop and renew all material that falls below acceptable thickness limits on the paddle wheel structural supports.
Condition: Unknown
Due 15 November 2001
Resolved 27 February 2004
Resolution: Corrected.
Construction/Loadline
Issued 18 January 2001 Resolved
Make permenant repairs to bow bulwark.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Construction/Loadline
Issued 18 January 2001 Resolved
Crop and renew all deck rail supports located aft end of third deck.
Condition: Unknown
Due 12 February 2001
Resolved 31 May 2001
Construction/Loadline
Issued 18 January 2001 Resolved
Crop and renew all upper deck supports located on the stern end of second deck.
Condition: Unknown
Due 12 February 2001
Resolved 31 May 2001
Construction/Loadline
Issued 18 January 2001 Resolved
Make permenant repairs to staircase between first and second decks on the bow.
Condition: Unknown
Due 12 February 2001
Resolved 31 May 2001
Construction/Loadline
Issued 9 December 1999 Resolved
REPAIR GUARD RAIL BOW AREA NEXT DRYDOCK
Condition: Unknown
Due 9 January 2000
Resolved 26 January 2000
Documentation
Issued 9 December 1999 Resolved
PROVIDE 50% OF CREW WITH CPR CARDS AND TRAINING.
Condition: Unknown
Due 9 January 2000
Resolved 7 February 2000
Fire Fighting
Issued 9 December 1999 Resolved
POST OPERATING INSTRUCTIONS IN ENGINEROOM ON THE STARTING OF FIRE PUMPS
Condition: Unknown
Due 9 January 2000
Resolved 7 February 2000
Fire Fighting
Issued 9 December 1999 Resolved
REPAIR/REPLACE ESCAPE HATCH AS TO ALLOW FOR EASY ESCAPE FROM ENGINE ROOM MAINTAIN WATERTIGHT INTRIGRITY. 46 CFR 116.500
Condition: Unknown
Due 9 January 2000
Resolved 26 January 2000
Lifesaving
Issued 12 March 1999 Resolved
Repair/ replace waterlight for ring buoy.
Condition: Unknown
Due 19 March 1999
Resolved 27 May 1999
Electrical
Issued 12 March 1999 Resolved
Place glass shield and wire cage around all lights in engine room.
Condition: Unknown
Due 19 March 1999
Resolved 27 May 1999
Lifesaving
Issued 12 March 1999 Resolved
Clear emergency exit for Engine Room.
Condition: Unknown
Due 26 March 1999
Resolved 27 May 1999
Engineering
Issued 12 March 1999 Resolved
Place guard around drive belt for pump on port engine.
Condition: Unknown
Due 19 March 1999
Resolved 27 May 1999
Fire Fighting
Issued 12 March 1999 Resolved
Repair/ rehang reel for #1 fire station.
Condition: Unknown
Due 19 March 1999
Resolved 27 May 1999
Fire Fighting
Issued 12 March 1999 Resolved
Provide documentation of fire extinguishing service.
Condition: Unknown
Due 19 March 1999
Resolved 27 May 1999
Lifesaving
Issued 12 March 1999 Resolved
Remark space containing 36 child and 36 adult life jackets to read "36 child and 36 adult lifejackets."
Condition: Unknown
Due 19 March 1999
Resolved 27 May 1999
Documentation
Issued 12 March 1999 Resolved
This discrepancy was generated for MV case purposes.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Lifesaving
Issued 12 March 1999 Resolved
Replace cover on water heater in snack area.
Condition: Unknown
Due 26 March 1999
Resolved 27 May 1999
Construction/Loadline
Issued 12 March 1999 Resolved
Provide high level bilge alarms in all spaces with through hull fittings below the waterline, to include, but not limited to lazarette, engine room,etc. I.A.W. CFR 182.530_x001C_ _x001C_
Condition: Unknown
Due 19 March 1999
Resolved 27 May 1999
Documentation
Issued 12 March 1999 Resolved
Provide and maintain a log for drills and crew training.
Condition: Unknown
Due 19 March 1999
Resolved 27 May 1999
Lifesaving
Issued 12 March 1999 Resolved
Provide 6 or more flares/ smoke devices.
Condition: Unknown
Due 19 March 1999
Resolved 27 May 1999
Engineering
Issued 15 June 1998 Resolved
MAKE PERMANENT REPAIRS TO WHERE PORT SIDE EXHAUST PENETRATES HULL.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Accommodation/Occupational Safety
Issued 15 June 1998 Resolved
SUBMIT PLANS FOR [name withheld] FOR 02 SUN DECK MEANS OF ESCAPE NO LATER THAT SEPT. 1, 1998.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Accommodation/Occupational Safety
Issued 15 June 1998 Resolved
MAKE MODIFICATIONS TO [name withheld] TO 02 SUN DECK IN OREDER TO COMPLY WITH 2 REQUIRED MEANS OF ESCAPE IN ACCORDANCE WITH 46 CFR 72.05 NO LATER THAN JAN. 30, 1999.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Accommodation/Occupational Safety
Issued 15 June 1998 Resolved
NO PASSENGERS ARE ALLOWED ON 02 SUN DECK UNTIL PLANS ARE SUBMITTED AND APPROVED BY [name withheld] FOR 02 SUN DECK ARRANGEMENT AND 2 REQUIRED MEANS OF ESCAPE.
Condition: Unknown
Due 26 June 1998
Resolved 1 July 1998
Electrical
Issued 14 May 1998 Resolved
DISCONTINUE USE OF EXTENSION CORDS AS PERMANENT WIRING THROUGHOUT THE VESSEL.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Electrical
Issued 14 May 1998 Resolved
REMOVE DEADEND WIRES THROUGHOUT VESSEL.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Lifesaving
Issued 14 May 1998 Resolved
PROVIDE 3 USCG APPROVED 30" LIFERINGS WITH RETRO-REFLECTIVE TAPE TO REPLACELIFERINGS WITH DETERIORATED OR MISSING PERIPHERAL LINES. ALL DEFICIENT LIFERINGS MUST BE REMOVED/REPLACED.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Electrical
Issued 14 May 1998 Resolved
REPAIR EMERGENCY LIGHTING OUTSIDE MAIN DECK HEADS.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Accommodation/Occupational Safety
Issued 14 May 1998 Resolved
REPLACE ROTTED WOOD RAILINGS ON AFT AND FORWARD STAIRS.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Documentation
Issued 14 May 1998 Resolved
DESIGNATE A SENIOR DECKHAND IN WRITING. THE LETTER MUST BE SIGNED BY THE VESSEL'S MASTER.
Condition: Unknown
Due 14 June 1998
Resolved 22 June 1998
Electrical
Issued 14 May 1998 Resolved
PROVIDE BLANK AND REPAIR LATCH TO ELECTRICAL DISTRIBUTION PANEL ADJACENT TOPILOT HOUSE LADDER.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Engineering
Issued 14 May 1998 Resolved
REINSULATE GENERATOR AND MAIN ENGINE EXHAUSTS. COVER ALL BARE METAL.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Lifesaving
Issued 14 May 1998 Resolved
REMOVE TRASH AND OILY RAGS FROM ENGINE ROOM AND ENGINE ROOM ENTRANCE VESTIBULE. PROVIDE METAL CAN WITH A SELF-CLOSING LID FOR OILY RAGS.
Condition: Unknown
Due 14 June 1998
Resolved 22 June 1998
Accommodation/Occupational Safety
Issued 14 May 1998 Resolved
PROVIDE EXIT SIGNS THAT SAY, "EMERGENCY EXIT, KEEP CLEAR", IN 2 INCH BLOCK LETTERS, AT EACH EXIT.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Lifesaving
Issued 28 January 1998 Resolved
PROPERLY STOW LIFEJACKETS W/ STRAPS LET OUT IN READY USE MANNER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Electrical
Issued 28 January 1998 Resolved
REMOVE ALL OUTLET MULTIPLIERS FROM SOCKETS (SEVERAL APPLIANCES PLUGGED INTOONE OUTLET)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Construction/Loadline
Issued 28 January 1998 Resolved
PROPERLY SECURE BACK COVER ON ENGINE DRIVEN BILGE PUMP WHERE BOLT IS MISSING AND SECURED W/ VICE GRIPS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Lifesaving
Issued 28 January 1998 Resolved
PROPERLY MOUNT RING BUOY W/ LIGHT & LINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Lifesaving
Issued 28 January 1998 Resolved
PROVIDE TWO ADDITIONAL (THREE TOTAL) RING BUOYS OF THE PROPER COLOR. (TWO HAVE BEEN PAINTED PINK ON ONE SIDE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Lifesaving
Issued 28 January 1998 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR RING BUOYS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Fire Fighting
Issued 19 December 1996 Resolved
Renew fire ext bracket aft 01 deck.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Electrical
Issued 19 December 1996 Resolved
Make proper splices & remove wire nuts on fan wiring, port/fwd eng rm.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Unknown
Issued 19 December 1996 Resolved
Provide current letter from Drug Consortium listing crew members enrolled.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Electrical
Issued 19 December 1996 Resolved
Remove all multiplex outlets & cords for exterior lighting.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Lifesaving
Issued 19 December 1996 Resolved
Provide proper painter on ring buoy & current battery for water light.
Condition: Unknown
Due 31 December 1996
Resolved 31 December 1996
Fire Fighting
Issued 21 December 1995 Resolved
Replace suction hose/provide hand fire pump to prove hand pump.
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Lifesaving
Issued 21 December 1995 Resolved
Provide one additional ring bouy.
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Unknown
Issued 21 December 1995 Resolved
Remove excess tables and chairs from 02 deck. Seating for 30 passengers & crew allowed on upper deck.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Lifesaving
Issued 21 December 1995 Resolved
Properly label children life preserver storage.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Electrical
Issued 21 December 1995 Resolved
Install battery disconnect switch for Main Gen set.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Navigation
Issued 21 December 1995 Resolved
Provide current NAV rules & 46 CFR part 16.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Construction/Loadline
Issued 12 September 1995 Resolved
Provide gauging report of area in way of fwd holding tank & fwd bulkhead insteering compt.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Construction/Loadline
Issued 12 September 1995 Resolved
Replace safety chain on #1 & #2 hold hatches.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Construction/Loadline
Issued 12 September 1995 Resolved
Repair dogging supports for deck hatch on # 2 hold.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Documentation
Issued 13 February 1995 Resolved
Vessel is restricted to a maximum capacity of 245 total passengers, not more than 30 of which may be on the top (02) deck, until the Marine Safety Center has completed their review of vessel stability.
Condition: Unknown
Due 13 February 1995
Resolved 13 February 1995
Fire Fighting
Issued 23 December 1994 Resolved
PUT VESSELS NAME ON FIRE AXE.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Construction/Loadline
Issued 23 December 1994 Resolved
INSTALL MISSING THRU HULL FITTINGS IN BOTH MSD TANK SPACES AND CLOSE HOLE IN FWD MSD SPACE AFT BULKHEAD.
Condition: Unknown
Due 24 December 1994
Resolved 4 January 1995
Documentation
Issued 23 December 1994 Resolved
POST A NEW OIL POLLUTION SIGN.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Electrical
Issued 23 December 1994 Resolved
SUBMIT PLANS TO MSO MIAMI FOR NEW GENERATOR INSTALLATION.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Accommodation/Occupational Safety
Issued 23 December 1994 Resolved
REPAIR BROKEN RAILING ON BOILER DECK.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Fire Fighting
Issued 23 December 1994 Resolved
RENEW ONE 50FT 1 AND 1/2 INCH FIRE HOSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 January 1995
Resolved 4 January 1995
Lifesaving
Issued 23 December 1994 Resolved
PROVIDE TWO NEW 24 INCH RING BUOYS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 22 January 1995
Resolved 4 January 1995
Fire Fighting
Issued 23 December 1994 Resolved
REMOVE THE TWO NON COAST GUARD APPROVED PRESSURE WATER FIRE EXTINGUISHERS.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Accommodation/Occupational Safety
Issued 23 December 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REMOVE ALL SEATING FROM UPPER MOST DECK AND SECURE THAT DECK TO PASSENGERS.
Condition: Unknown
Due 24 December 1994
Resolved 4 January 1995
Accommodation/Occupational Safety
Issued 23 December 1994 Resolved
CONDUCT AN INCLINING STABILITY TEST NOT LATER THAN 22 JAN 95 OR REMOVE THE UPPER DECK RAILINGS, WOOD GRATING AND AFT AXCESS STAIRS. RETURNING VESSEL TO CONDISHION AT ORIGIONAL STABILITY TEST.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Electrical
Issued 23 December 1994 Resolved
RAISE ANCHOR LIGHT SO IT WILL NOT BE BLOCKED BY PILOT HOUSE TOP.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Construction/Loadline
Issued 8 January 1994 Resolved
EFFECT PERMANENT REPAIRS TO WATERTIGHT BULKHEADS AT PVC PIPING PENETRATIONS, RESTORING WATERTIGHT INTEGRITY. THROUGH HULL PENETRATIONS IMPROPER.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Electrical
Issued 8 January 1994 Resolved
PROPERLY SEVURE OR REMOVE THE DEAD END WIRES THROUGHOUT THE VESSEL.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Lifesaving
Issued 8 January 1994 Resolved
REMOVE INTERIOR PLASTIC CHAIRS AND PLASTIC TRASH CANS AS PER 46CFR72.05- 55.THIS ITEM HAS BEEN APPEALED BY THE VESSEL OWNER.
Condition: Unknown
Due 8 January 1994
Resolved 8 January 1994
Lifesaving
Issued 8 January 1994 Resolved
REMOVE CARD BOARD AND COMBUSTIBLES FROM THE LAZERATTE AND OTHER VOID SPACES. PROVIDE A CONTINOUS STEEL COVER FOR THE OPENING TO THE LAZERATTE IF STORES ARE CARRIED IN THIS SPACE.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Documentation
Issued 8 January 1994 Resolved
POST ORIGINAL STABILITY LETTER ON BRIDGE.
Condition: Unknown
Due 8 January 1994
Resolved 8 January 1994
Engineering
Issued 8 January 1994 Resolved
REPLACE NON-APPROVED DIESEL FUEL HOSES ON THE MAIN ENGINES AND THE GENERATORS AS REQUIRED BY 46CFR182.20-40(2).
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Lifesaving
Issued 8 January 1994 Resolved
PROVIDE PERSONNEL GUARDS IN WAY OF THE GENERATOR FAN BELT. THIS ITEM HAS BEEN APPEALED BY THE VESSEL OWNER.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Lifesaving
Issued 8 January 1994 Resolved
REPAIR LAGGING ON THE MAIN ENGINE EXHAUSTS.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Documentation
Issued 8 January 1994 Resolved
PROVIDE FCC STATION LICENSE. VESSEL IS RESTRICTED TO 1000 FEET FROM SHORE UNTIL NEW LICENSE ISSUED.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Lifesaving
Issued 8 January 1994 Resolved
PROVIDE PLATFORM AT THE BOTTOM OF THE RESCUE LADDER.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Documentation
Issued 8 January 1994 Resolved
PROVIDE ORIGINAL OPERATOR'S LICENSE FOR REVIEW.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Documentation
Issued 8 January 1994 Resolved
submit written proof os a drug testing program which complies w/ 46CFRpart16 to O_x001C_ CMI MIAMI.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Fire Fighting
Issued 8 January 1994 Resolved
PROVIDE APPROVED MARINE TYPE BARCKET FOR THE B-I FIRE EXTINGUISHER ON THE BRIDGE.
Condition: Unknown
Due 8 February 1994
Resolved 7 February 1994
Fire Fighting
Issued 8 January 1994 Resolved
PROVIDE FIRE HOSES NOZZLES AS REQUIRED BY 46CFR181.15-10(D)(2). THIS ITEM HAS BEEN APPEALED BY THE OWNER.
Condition: Unknown
Due 8 January 1994
Resolved 8 January 1994
Fire Fighting
Issued 13 December 1991 Resolved
Provide suitable length of suction hose on hand held firepump
Condition: Unknown
Due 13 December 1991
Resolved 13 December 1991
Electrical
Issued 13 December 1991 Resolved
Prove proper operation of emergency lights
Condition: Unknown
Due 13 December 1991
Resolved 13 December 1991
Documentation
Issued 13 December 1991 Resolved
Porvide current cert of documentation showing vessels new name and owner.
Condition: Unknown
Due 13 December 1991
Resolved 13 December 1991
Lifesaving
Issued 13 December 1991 Resolved
Stencil vessel's new name on all required life saving equipment.
Condition: Unknown
Due 13 December 1991
Resolved 13 December 1991
Deck/Cargo
Issued 13 December 1991 Resolved
Prove proper operation of anchor windlass
Condition: Unknown
Due 13 December 1991
Resolved 13 December 1991
Construction/Loadline
Issued 3 May 1991 Resolved
stencil draft marks on hull of vessel_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Lifesaving
Issued 3 May 1991 Resolved
provide one orange hand held flare._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Navigation
Issued 3 May 1991 Resolved
prove proper operation of port side navigation light._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Navigation
Issued 3 May 1991 Resolved
repair and prove proper operation of mast head light_x001C_ _x001C_ _x001C_ r _x001C_
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Documentation
Issued 2 July 1990 Resolved
OBTAIN CERTIFICATE OF DOCUMENTATION REFLECTING VESSEL NAME CHANGE
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Lifesaving
Issued 2 July 1990 Resolved
MARK ALL LIFE PRESERVERS, RING BOUYS AND LIFE FLOATS WITH VESSEL NAME.
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Documentation
Issued 2 July 1990 Resolved
OBTAIN FCC RADIOTELEPHONE SAFETY CERTIFICATE.
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Fire Fighting
Issued 12 April 1988 Resolved
PROVIDE LONGER HOSE ON HAND PUMP FOR OVER THE SIDE DISCHARGE FOR INTERIOR SPACE.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Electrical
Issued 12 April 1988 Resolved
MAKE THE GENERATOR EXHAUST GAS TIGHT.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Unknown
Issued 12 April 1988 Resolved
EITHER INSULATE OR INSTALL GRATING AROUND GENERATOR AND M/E EXHAUST RUNS INENGINE ROOM.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Lifesaving
Issued 12 April 1988 Resolved
REPLACE ONE ORANGE AND SIX RED FLARES.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Lifesaving
Issued 12 April 1988 Resolved
REPLACE ONE WATERLIGHT ON B/A.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Lifesaving
Issued 15 April 1985 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE, PROVIDE ONE ADDITIONAL AP- PROVED WATER LIGHT. NOTIFY THIS OFFICE IN WRITING WHEN THE REQUIREMENT HAS BEEN SATISFIED.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985
Lifesaving
Issued 15 April 1985 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE, PROVIDE FOUR ADDITIONAL APPROVED HAND RED FLARES AND ONE ADDITIONAL HAND ORANGE SMOKE FLARE. NOTIFYTHIS OFFICE IN WRITING WHEN THE REQUIREMENT HAS BEEN SATISFIED.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.