Records from 1984 to 2003. Most recent: inspection, 17 October 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
17 October 2003
Permit to Proceed
Administrative · Activities Europe · Activity 1923884
28 October 2002
Deficiency Check
Physical examination · Activities Europe · Activity 1696948
1 September 2002
Annual Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 1655031
22 August 2001
Re-Inspection
Physical examination · Activities Europe · Activity 1362573
10 September 2000
Hull Examination
Physical examination · Activities Europe · Activity 1361706
22 June 2000
Deficiency Check
Physical examination · Activities Europe · Activity 818944
23 May 2000
COI Inspection
Physical examination · Activities Europe · Activity 1365787
21 June 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445486
29 July 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665625
15 June 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 792496
11 June 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390786
30 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214509
16 April 1997
Deficiency Check
Physical examination · Activities Europe · Activity 1098378
6 December 1996
COI Inspection
Physical examination · Activities Europe · Activity 1363886
9 September 1996
Administrative
Administrative · Activities Europe · Activity 946347
18 March 1996
Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 884609
8 December 1995
Deficiency Check
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 876125
30 September 1995
Hull Examination · Re-Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1182693
25 January 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842336
23 December 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 866591
2 December 1993
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1163151
11 June 1993
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153966
12 April 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1147199
4 March 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1143007
21 December 1992
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 828794
20 July 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246598
1 March 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 954868
11 March 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237766
11 March 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241406
25 February 1991
Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231232
10 September 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 908938
30 July 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1295889
16 June 1990
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1235060
28 June 1989
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 894783
31 May 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1198216
20 June 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1210656
22 December 1987
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1007044
8 October 1987
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1324384
15 September 1987
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1005153
23 June 1987
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1338959
26 February 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1007015
20 October 1986
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016853
23 June 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985137
25 July 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297545
14 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972622
Documentation › Certificates/Documents
Issued 1 September 2002
Resolved
Provide valid IOPP certificate. LEGACY COMPONENT DESC: IOPP Certificate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 4 October 2002
Resolution: Rcvd fax clearing CG 835
Communications › Radio Communications › EPIRB
Issued 1 September 2002
Resolved
Prove EPIRB is registered with NOAA or COSPAS
Due 2 September 2002
Resolved 2 September 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 1 September 2002
No resolution recorded
Renew all flexible loops on engine room fixed CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2002 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 1 September 2002
No resolution recorded
Provide flame screens in liquid mud tank vents.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2002 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 1 September 2002
Resolved
Repair or renew wasted goose neck fuel tank vents.
Condition: Improper/Lack of Maintenance
Due 2 September 2002
Resolved 2 September 2002
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 1 September 2002
No resolution recorded
Prove hydrostatic test of SCBA breathing cylinder.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 October 2002 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 1 September 2002
No resolution recorded
Repair 440V breaker panel at bottom of ladder to engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2002 — due date passed with no resolution recorded
Electrical › Electric Generation Source (service)
Issued 1 September 2002
Resolved
Properly dead end or remove wire behind engine room CO2 system in bow thruster room. LEGACY COMPONENT DESC: Conductor
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2002
Resolved 4 October 2002
Resolution: Rcvd fax clearing CG 835
Engineering › Fuel Oil Storage/Transfer System
Issued 1 September 2002
Resolved
Properly repair fuel oil day tank level indicator and remove temporary sight glass. LEGACY COMPONENT DESC: Gauge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2002
Resolved 4 October 2002
Resolution: Rcvd fax clearing CG 835
Electrical › Electric Generation Source (service) › Panelboard
Issued 1 September 2002
No resolution recorded
Properly dead front main switchboard in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2002 — due date passed with no resolution recorded
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 1 September 2002
No resolution recorded
Provide proper CO2 alarm in engine room in lieu of automotive air horn installed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 October 2002 — due date passed with no resolution recorded
Deck/Cargo › Mooring/Anchoring › Brake
Issued 1 September 2002
No resolution recorded
Provide brake handle for port anchor windlass brake.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2002 — due date passed with no resolution recorded
Construction/Loadline › Markings
Issued 1 September 2002
Resolved
Properly mark ABS loadline and hailing port on stern of vessel. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2002
Resolved 4 October 2002
Resolution: Rcvd fax clearing CG 835
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 September 2002
No resolution recorded
Prove proper operation of OWS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2002 — due date passed with no resolution recorded
Unknown
Issued 22 August 2001
Resolved
INSTALL ABS APPROVED ANCHOR (STBD) OF APPROPRIATE WEIGHT.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Unknown
Issued 22 August 2001
Resolved
RENEW DECK RAILS ON THE PORT/STBD MAIN DECK.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Unknown
Issued 22 August 2001
Resolved
INSTALL VALVE HANDLES/REPLACE VALVES ON BILGE MANIFOLD.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Unknown
Issued 22 August 2001
No resolution recorded
PROVE THE OPERATION OF THE OWS CONTENT ALARM.
Condition: Unknown
Due 31 December 2001 — due date passed with no resolution recorded
System not recorded
Issued 22 August 2001
Resolved
PROVE THE OPERATION OF THE REVERSE POWER RELAY ON PORT GENSET.
Condition: Unknown
Due 31 December 2001
Resolved 1 September 2002
Resolution: Tested during annual.
Unknown
Issued 22 August 2001
Resolved
INSTALL MISSING CO2 CYLINDERS FOR THE E/R FIREFIGHTING SYSTEM AND PROVIDE SERVICING REPORT.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Construction/Loadline
Issued 23 May 2000
Resolved
Make permanent repairs to the oily water separator.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Lifesaving
Issued 23 May 2000
Resolved
Install lifelines on life buoys in accordance with 46CFR133.70(a)(4)(ii). Note: Lifelines are not to be installed on life buoys with smoke or lights.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Unknown
Issued 23 May 2000
Resolved
Provide proper documentation of fully compliant chemical testing program for the following deficency; Provide a manual containing the procedures fortesting after a serious marine incident and reasonable cause. Vessel is not permitted to operate after 30jun00 unless this requirement is satisfied
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Navigation
Issued 21 June 1999
Resolved
PROVIDE LOCAL NOTICE TO MARINERS FOR ONBOARD CHARTS.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Construction/Loadline
Issued 21 June 1999
Resolved
SECURE THE OILY WATER SEPARATOR OVERBOARD DISCHARGE VALVE AND RETAIN ALL OILY WASTE ONBOARD FOR DISCHARGE TO APPROPRIATE SHORESIDE FACILITY UNTIL SUCH TIME THE PROPER OPERATION OF THE OILY WATER SEPARATOR CAN BE PROVEN TOAN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Documentation
Issued 21 June 1999
Resolved
SUBMIT COPY OF UPDATED FIRE & SAFETY PLAN, VERIFIED & SIGNED BY ATTENDING MARINE INSPECTOR. PLAN TO BE UPDATED W/ IMO SYMBOLOGY & SUBMITTED TO MSO NEW ORLEANS, NEW CONSTRUCTION OFFICE FOR APPROVAL.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Navigation
Issued 11 June 1998
Resolved
Provide instructions for shift of steering gear iaw 46CFR131.845.
Condition: Unknown
Due 11 June 1998
Resolved 11 June 1998
Navigation
Issued 11 June 1998
Resolved
Provide new deviation table for vessel's magnetic compass.
Condition: Unknown
Due 11 June 1998
Resolved 11 June 1998
Electrical
Issued 6 December 1996
Resolved
REPAIR/RENEW PORT GENERATOR OVERSPEED TRIP AND PROVE PROPER OPERATION TO A C.G. MARINE INSPECTOR.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Documentation
Issued 6 December 1996
Resolved
PROVIDE ONBOARD AND POST THE LINE DIAGRAM REQUIRED FOR EACH PIPING SYSTEM FOR THE OIL TRANSFER PROCEDURE.
Condition: Unknown
Due 6 December 1996
Resolved 6 December 1996
Lifesaving
Issued 30 September 1995
Resolved
INSTALL NEW HYDROSTATIC RELEASE FOR EPIRB. 406 MHZ ALDEN ELECTRONICS.
Condition: Unknown
Due 30 September 1995
Resolved 30 September 1995
Navigation
Issued 23 December 1994
Resolved
PROVIDE VESSEL WITH NAVIGATIONAL LIGHTING SYSTEM THAT COMPLIES WITH 46 CFR 111.75-17(B). THIS INCLUDES VISUAL AND AUDIBLE ALARMS FOR LIGHT FIXTURES AND DUPLICATE LIGHT SOURCES.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Unknown
Issued 23 December 1994
Resolved
REPAIR AND PROVE PROPER OPERATION OF OILY WATER SEPERATOR.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Deck/Cargo
Issued 11 June 1993
Resolved
MAKE PROPER REPAIRS TO SPLIT + CRACK ON AGITATOR SLIDE IN AFT PORT BULK TANK.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Navigation
Issued 21 December 1992
Resolved
PROVIDE DEVIATION TABLE.
Condition: Unknown
Due 21 December 1992
Resolved 21 December 1992
Engineering
Issued 1 March 1992
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Fire Fighting
Issued 1 March 1992
Resolved
PROVIDE DRAWING OF CO2 FIXED FIRE EXTINGUISHING SYSTEM AND UP TO DATE INSTRUCTION FOR OPERATION OF SAME._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Electrical
Issued 16 June 1990
Resolved
INSTALL LOCKING BAR ON GENERATOR SWITCH BOARD TO ENSURE GENERATOR BREAKERS CANNOT BE ENERGIZED AT THE SAME TIME AS SHORE POWER BREAKER.
Condition: Unknown
Due 16 June 1990
Resolved 16 June 1990
Construction/Loadline
Issued 16 June 1990
Resolved
REPLACE BROKEN GLASS ON AFT WINDOWS IN PILOT HOUSE.
Condition: Unknown
Due 16 June 1990
Resolved 16 June 1990
Accommodation/Occupational Safety
Issued 16 June 1990
Resolved
REPAIR OR REPLACE DRYER VENT STBD SIDE FWD.
Condition: Unknown
Due 16 June 1990
Resolved 16 June 1990
Deck/Cargo
Issued 16 June 1990
Resolved
PRIOR TO USE OF CEMENT TANKS ( SIX PRESSURE VESSELS) PRESENT FOR INSPECTIONAND TEST OF RELIEF VALVES.
Condition: Unknown
Due 16 June 1990
Resolved 16 June 1990
Lifesaving
Issued 16 June 1990
Resolved
NUMBER OF PERSONS SHALL BE LIMITED TO TEN (10) UNTIL PROPER LIFE RAFTS ON BOARD.
Condition: Unknown
Due 16 June 1990
Resolved 16 June 1990
Navigation
Issued 16 June 1990
Resolved
REPLACE HYDRAULIC LINE, PORT RUDDER CYLINDER, AND INSTALL TO KEEP FROM RUBBING ON BAR.
Condition: Unknown
Due 16 June 1990
Resolved 16 June 1990
Engineering
Issued 16 June 1990
Resolved
REPLACE AIR RECIEVER RELIEF VALVE AND PROVE PROPER OPERATION/PORT AIR RECVR
Condition: Unknown
Due 16 June 1990
Resolved 16 June 1990
Engineering
Issued 16 June 1990
Resolved
INSTALL TANK LEVEL INDICATING DEVICES OF FUEL OIL TANKS IAW 46 CFR 58.50-10(A)(6). HEAT RESISTANT SIGHT GLASSES & VALVES ON BOTH ENDS TUBE WITH PROTECTION FROM MECHANICAL DAMAGE.
Condition: Unknown
Due 16 June 1990
Resolved 16 June 1990
Fire Fighting
Issued 31 May 1989
Resolved
PROVIDE INSTRUCTIONS TO OPERATE ENGINEROOM FIXED CO2 SYSTEM CONTROLS INCLUDING VENTILATION AND MACHINERY SHUTDOWN.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Engineering
Issued 31 May 1989
Resolved
DEMONSTRATE OPERATION OF 3 BILGE ALARMS.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Accommodation/Occupational Safety
Issued 31 May 1989
Resolved
FREE UP AND PROVE OPERATION OF FOREPEAK BILGE SUCTION REACHROD.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Fire Fighting
Issued 31 May 1989
Resolved
RENEW FIXED CO2 DELAY FOR ENGINEROOM SYSTEM.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Engineering
Issued 31 May 1989
Resolved
PROVIDE MANUFACTURERS TEST PROCEDURES FOR AND CONDUCT SATISFACTORY TEST OF OILY WATER SEPARATOR AND 15PPM RECIRCULATOR SWITCH.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Electrical
Issued 31 May 1989
Resolved
REPAIR TACHOMETER ON STBD GENERATOR.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Fire Fighting
Issued 23 June 1987
Resolved
PROVIDE AND INSTALL A SATISFACTORY FIXED CO2 SYSTEM TIME DELAY AND PROVE BYOPERATION.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987