Records from 1984 to 2007. Most recent: inspection, 8 June 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 8 June 2007
No resolution recorded
Provide copy of interum / provisional loadline certificate
Action required: 705 - Other - as specified
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 8 June 2007
No resolution recorded
Provide copy of ABS report of hull/loadline survey including 6S, 6P, and void beneath locker room
Action required: 705 - Other - as specified
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 June 2007
No resolution recorded
Provide copy of UT report in support of most recent loadline/hull exam.
Action required: 705 - Other - as specified
Construction/Loadline › Structures › Door
Issued 8 June 2007
No resolution recorded
Ensure all watertight doors have proper seal.
Action required: 705 - Other - as specified
Deck/Cargo › Cargo Stowage › General
Issued 8 June 2007
No resolution recorded
Ensure all equipment / items on deck are secure for sea
Action required: 705 - Other - as specified
Fire Fighting
Issued 13 December 1988
Resolved
REPAIR LEAKS TO FIREMAIN IN AUXILLARY MACHINERY SPACE AND MUD PUMP ROOMS. AFTER REPAIRS ARE COMPLETE SCHEDULE TEST OF FIRE MAIN SYSTEM IN PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Construction/Loadline
Issued 13 December 1988
Resolved
REPAIR WATER TIGHT DOOR (WARPED, WILL NOT SEAL) IN JACKING ROOM #2 MAIN DECK.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Fire Fighting
Issued 13 December 1988
Resolved
CLEAR THE PLUGGED FIRE MAIN LINE TO FIRE STATION 15.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Electrical
Issued 13 December 1988
Resolved
POUR EYS FITTING ON "HEAT TRACE SWITCH" PRODUCTION AREA.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Electrical
Issued 13 December 1988
Resolved
REMOVE DEAD END WIRING AND DISCONTINUED SWITCH BOX ON MULTISEPARATOR.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Electrical
Issued 13 December 1988
Resolved
REPLACE THE GENERAL ALARM BATTERIES. POWER DROP TO ZERO WAS OBSERVED AFTER 10 SEC. OF OPERATION
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Electrical
Issued 13 December 1988
Resolved
POUR EYS ON "LACT" EXPLOSION PROOF SWITCH BOX.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Electrical
Issued 13 December 1988
Resolved
REPLACE PLUG AND SOCKET FOR AFT RUNNING LIGHT WITH EXPLOSION PROOF TYPE FOR CLASS I DIVISION II AREA.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Construction/Loadline
Issued 13 December 1988
Resolved
PROVIDE PROTECTIVE COVER FOR THE SIGHT GLASS ON THE SETTLING TANK BELOW THEPRODUCTION AREA.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Electrical
Issued 13 December 1988
Resolved
RE-FASTEN CONDUIT ON TOP OF A/C DISCONNECT LOCATED ABOVE JACKING CONTROL HOUSE.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Electrical
Issued 13 December 1988
Resolved
FILL EYS FITTINGS ON TRANSFER PUMP IN VICINITY OF SURGE TANK IN THE PRODUCTION AREA.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Deck/Cargo
Issued 13 December 1988
Resolved
PROVIDE PROTECTED SIGHT GLASS ON SURGE TANK IN PRODUCTION AREA.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Accommodation/Occupational Safety
Issued 13 December 1988
Resolved
PROVIDE VENTILATION SHUT DOWN FOR THE MAIN QUARTERS.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Lifesaving
Issued 13 December 1988
Resolved
MAKE OPERABLE THE ENGINE IN NUMBER 2 BOAT (WILL NOT START). COMPLY BY: 21DEC88
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Engineering
Issued 13 December 1988
Resolved
MAKE OPERABLE THE FUEL OIL CENTRIFUGE.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Electrical
Issued 13 December 1988
Resolved
PROVIDE MARKINGS TO ALL BREAKERS IN THE POWER PANELS LOCATED IN AUX. MACHINERY SPACES.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Engineering
Issued 13 December 1988
Resolved
MAKE OPERABLE ALL GENERATORS AND APPLICABLE TESTS (IE. OVERSPEED, HIGH TEMPLOW LUBE).
Condition: Unknown
Due 15 March 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 13 December 1988
Resolved
PERFORM DRY DOCK EXAMINATION. DRY DOCK WAS DUE JAN. 88 (NOTIFIED MARILYN ZOLLER VIA LANDLINE 12/16/88).
Condition: Unknown
Due 13 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 13 December 1988
Resolved
SERVICE THE COMPASS IN THE LIFE BOAT NUMBER 1 TO REMOVE AIR BUBBLE.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Navigation
Issued 13 December 1988
Resolved
ROTATE THE 135 DEGREE STERN LIGHT SO THAT THE LIGHT SECTOR IS CENTERED POINTED AFT TO SHOW THE LIGHT 67.5 DEGREES ON EACH SIDE.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Construction/Loadline
Issued 13 December 1988
Resolved
INSERT PLATE TO REPAIR 4 INCH ROUND HOLE IN THE HELO DECK AT THE STARBOARD ENTRANCE.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Construction/Loadline
Issued 13 December 1988
Resolved
REATTACH WASTED LADDER ATTACHMENT ON THE TOP OF THE CONTROL ROOM.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Unknown
Issued 26 January 1987
Resolved
REPLACE BROKEN DEAD MAN NOZZLE FOR PORT SIDE CRANE FUEL FILL 46 CFR 109.521COMPLIANCE DATE IS 26MAR87.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Unknown
Issued 26 January 1987
Resolved
REPLACE BROKEN SEAT ON PORT SIDE CRAND 46 CFR 109.521. COMPLIANCE DATE IS 26MAR87.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Unknown
Issued 26 January 1987
Resolved
REPLACE WASTED GUARD RAIL CASE ON PORT SIDE CRANE 46 CFR 109.521. COMPLIANCE DATE IS 26MAR87.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Lifesaving
Issued 26 March 1984
Resolved
MAKE REPAIRS TO THE ENGINE IN THE NUMBER TWO LIFEBOAT. THE ENGINE IS PRE- SENTLY INOPERATIVE. 46 CFR 109.217
Condition: Unknown
Due 2 April 1984
Resolved 26 March 1984
Accommodation/Occupational Safety
Issued 26 March 1984
Resolved
REPAIR THE THREE BULK CEMENT TANK RELIEF VALVES WITH VALVES FITTED WITH HAND RELIEVING GEAR. 46 CFR 54.15-10[C]
Condition: Unknown
Due 26 March 1984
Resolved 26 March 1984
Documentation
Issued 26 March 1984
Resolved
RESUBMIT THE OPERATING MANUAL TO THE MARINE INSPECTION OFFICE, NEW ORLEANS FOR FORWARDING TO THE MERCHANT MARINE TECHNICAL OFFICE. 46 CFR 109.121
Condition: Unknown
Due 26 March 1984
Resolved 26 March 1984