CAPT. ANDERSON III

CAPT. ANDERSON III is a 1984 passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1984, most recently in March 2026, along with 134 deficiencies, 1 operational control and 3 casualty investigations between 2006 and 2009.

Records from 1984 to 2026. Most recent: inspection, 5 March 2026.

Built
1984
Last inspected
5 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE3147
232682
Flag
UNITED STATES
367334710
Maury page id
psix-232682

Inspections, by type

…with no type recorded5
Years with a record 39 calendar years (1984–2026)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.4 ft × 26.8 ft × 6.2 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderQUEEN CRAFT SHIPYARD · PANAMA CITY FL, UNITED STATES · built 1984
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 10 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE3147MMSI 367334710 · active · compulsorily equipped · granted 27 December 2017, expires 30 January 2028
WBR3313MMSI 366677000 · expired · compulsorily equipped · granted 15 January 1998, cancelled 10 May 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 73

5 March 2026 Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8320538
9 January 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8057195
27 November 2024 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8029069
7 February 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7862625
10 October 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7806185
8 May 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7683454
14 March 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7650840
7 February 2023 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7634044
28 November 2022 Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7611824
18 February 2022 MTSA Verification · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7394360
9 February 2021 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7137932
30 November 2020 Examination of Repairs · Hull Examination · Administrative Inspection · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7103462
24 February 2020 Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6915379
15 April 2019 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6664537
29 November 2018 Hull Examination · Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6591122
14 November 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580519
12 February 2018 Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6350399
15 February 2017 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6086151
24 October 2016 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6028278
25 April 2016 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5860528
26 March 2014 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4831174
13 February 2012 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4243725
8 December 2010 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3904556
30 March 2010 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3701921
2 February 2009 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3426582
9 December 2008 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3376310
31 March 2008 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3173145
12 March 2007 MTSA Verification · COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2962527
15 May 2006 Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2649486
14 May 2006 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2664382
23 March 2006 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2610611
23 March 2006 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2632463
23 May 2005 MTSA Verification
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2366311
11 April 2005 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2331503
6 April 2005 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2327544
9 November 2004 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2238937
6 April 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2038217
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1972310
12 March 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1756168
5 November 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1701131
11 March 2002 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1494379
16 March 2001 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1470015
10 March 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1459612
12 March 1999 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1416948
16 December 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 797826
30 November 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1375577
15 April 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1364694
15 April 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1380834
18 March 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1428733
20 February 1997 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1107419
2 August 1996 Deadweight Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1088966
11 March 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1079885
11 March 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1080057
11 March 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1374531
28 February 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1385406
20 January 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1367279
4 March 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 856310
10 January 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 851881
6 August 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 844351
4 March 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 847466
14 January 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1139915
4 March 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1013354
20 March 1991 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1236537
21 February 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 925503
31 October 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1224625
16 February 1990 Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 903262
1 March 1989 Re-Inspection · Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 889748
16 February 1988 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1030015
18 February 1987 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1318623
11 October 1985 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 985834
1 October 1985 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1301586
25 September 1985 Excursion Permit
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 991974
22 June 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973347

Deficiency record · 134

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2024 Resolved
Fuel leak present in tank space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 February 2024 Resolved
Engine compartment escape hatch could not be opened from inside space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2024
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 7 February 2024 Resolved
Ovbd penetration in tank room terminated in PVC pipe/cap.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2024
Resolved 13 February 2024
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 February 2024 Resolved
DSC VHF radio function was not programmed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2024
Resolved 13 February 2024
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2024 Resolved
Power strip was in use on the bridge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 February 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 February 2023 Resolved
Minimum capacity of power fire pump shall be 50 gallons per minute at a pressure of not less than 60 PSI in accordance with 46 CFR old T 181.10-1(c). 60 PSI could not be verified on installed guage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2023
Resolved 7 April 2023
Resolution: Witnessed the newly installed gauge and the fire-pump producing a capacity of 50gpm at 60psi.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 February 2021 Resolved
Replace all soft patches in installed Bilge System located in the Tank Room, Engine Room and Glass Bottom. Complete at next Drydock.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 March 2023
Resolved 14 March 2023
Resolution: Witnessed the satisfactory replacement of all soft patches located in the installed Bilge System.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 9 February 2021 Resolved
Secure refrigerator to deck and properly latch door.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 10 February 2021
Resolution: Refrigerator properly latched and secured to the deck.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 February 2021 Resolved
Repair/Replace broken electrical outlet in Galley.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 10 February 2021
Resolution: Electrical outlet replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2020 Resolved
Ensure double hose clamps in steering on rudder.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner installed double hose clamps on rudders.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2020 Resolved
Install/Ensure index is available for breaker boxes.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner added index on each breaker box.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2020 Resolved
Replace/Secure broken seat on deck.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner repaired boken seat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 February 2020 Resolved
Replace/Install gaskets for parlor doors.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner renewed weather strip gaskets on parlor doors.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 24 February 2020 Resolved
Ensure proper signage in place around Engine Room Escape Hatch.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner renewed proper signage around engine room escape hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 February 2020 Resolved
Label Bilge suction on collision bulkhead.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner labeled bige suction valve on collision bulkhead.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 February 2020 Resolved
Show proof of FCC Documentation and Radio Safety Certificate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner provided proof of FCC documentation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2020 Resolved
Install engine room hatch.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner reinstalled engine room hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2020 Resolved
Renew exhaust lagging on both main engines.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner replaced exhaust lagging on both main engines.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 February 2020 Resolved
Install main engine machinery guards.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner fabricated new machinery guards on main engines.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2020 Resolved
Replace/Renew/Repair A60 insulation in following space: Forward Locker.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2020
Resolved 24 March 2020
Resolution: Owner hired contractor to install new A-60 insulation in forward locker.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2020 Resolved
Provide proof of emergency operating instructions.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner provided proof of emergency operating instructions.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 24 February 2020 Resolved
Remove storage items from engine room.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner removed storage items from engine room.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 24 February 2020 Resolved
Show proof that horn is operable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner demonstrated that horn is operable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2020 Resolved
Add power strip for electronics in pilothouse. Remove what is currently installed.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner added additional power strip for pilot house.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2020 Resolved
Mount 02 junction boxes in forward locker on bulkhead.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 24 March 2020
Resolution: Owner mounted 02 junction boxes in forward locker.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2019 Resolved
Several electrical cables were found with missing insulation due to a rodent infestation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 April 2019
Resolution: Technician was hired to replace bad cables and Meg system to check for shorts to ground. Scope of work was provided along with final billing.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 April 2019 Resolved
Main deck lighting was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2019
Resolved 24 April 2019
Resolution: Repaired main deck lighting, tested all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 April 2019 Resolved
Several electrical receptacles were missing or had broken covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2019
Resolved 17 April 2019
Resolution: Receptacle covers were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2019 Resolved
Spanner wrench was missing on main deck fire station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2019
Resolved 24 April 2019
Resolution: Replaced spanner wrench, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 15 April 2019 Resolved
Cables and hoses need to be removed from watertight bulkhead in forward void; properly seal bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 24 April 2019
Resolution: Removed cables and hoses and properly sealed bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 April 2019 Resolved
Bilge piping penetrating the collision bulkhead is extremely corroded and needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 24 April 2019
Resolution: Replace wastage bilge pipe in collision bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2019 Resolved
Return valve on fuel tank has a broken handle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 24 April 2019
Resolution: Replace valve handle, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2019 Resolved
Vessel has been out of service for storm damage and may not operate until MSD Panama City conducts and issues a Certificate of Inspection
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2019
Resolution: Vessel completed hull exam and annual exam.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 November 2018 Resolved
Due to the vessel's grounding the vessel is required to be dry docked for a full damage survey.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2018
Resolution: Vsl drydocked at Master Marine in Bayou La Batre, AL. Damage Survey Conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 November 2018 Resolved
Vessel is permitted to transit to Bayou La Batre via the ICW. Once underway the vessel is to check in with Sector Mobile and check in again once the vessel moors in Bayou La Batre. Any change in the vessel's condition or failure in equipment is to be immediately reported to the nearest OCMI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2018
Resolution: Vsl safely transitted to Master Marine in Bayou La Batre, AL.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 November 2018 Resolved
Due to damages sustained during Hurricane Michael a repair plan must be submitted to Sector Mobile detailing proposed repairs prior to starting work. All repairs are to be verified by an attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
Resolution: Vessel completed satisfactory hull examination
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 November 2018 Resolved
Vessel's flares are expired. Replace flares prior to sail. Vessel is required to have 3 smoke and 3 red or 6 red.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2018
Resolution: Vessel owner provided receipts and photos of the new flares.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 February 2018 Resolved
Repair Retroreflective material/ foam on all life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2018
Resolved 12 March 2018
Resolution: new Retro tape was installed.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 12 February 2018 Resolved
Repair exhaust leak on Port Main Engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2018
Resolved 12 March 2018
Resolution: The leak was repaired
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 February 2018 Resolved
Provide cover for electrical box in engine room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 March 2018
Resolved 12 March 2018
Resolution: a cover was installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 April 2016 Resolved
Replace ring buoy line.
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 2 May 2016
Resolution: Vessel replaced line
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 March 2014 Resolved
Replace expired EPRIB battery. Vessel is restricted to no more than 3NM
Action required: 705 - Other - as specified
Due 26 April 2014
Resolved 15 April 2014
Resolution: Vessel replace and properly registered EPRIB.
Fire Fighting › Fire Pumps › Pressure
Issued 26 March 2014 Resolved
Repair fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2014
Resolved 26 March 2014
Resolution: Vessel repaired and satisfactory tested fire pump.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 March 2014 Resolved
Provide 21 servicable lifejackets. Vessel total persons allowed is reduced to 203
Action required: 705 - Other - as specified
Due 10 April 2014
Resolved 9 April 2014
Resolution: Vessel provided 21 servicable lifejackets.
Engineering › Bilge Water Management System › Piping
Issued 30 March 2010 Resolved
Replace the broken thru-hull on the bilge system in the Engine room, stbd.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2010
Engineering › Lubricating Oil Service System › Hose
Issued 30 March 2010 Resolved
Repair numerous oil leaks on the Port Main Diesel Engine, hoses and seals.
Condition: Improper/Lack of Maintenance
Due 30 March 2010
Resolved 5 April 2010
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 30 March 2010 Resolved
Double clamp the shaft boots on both shafts.
Condition: Improper/Lack of Maintenance
Due 30 March 2010
Resolved 5 April 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 March 2010 Resolved
Relabel Lifejacket storage box on the aft box.
Condition: Improper/Lack of Maintenance
Due 30 March 2010
Resolved 5 April 2010
Engineering › Bilge Water Management System › Piping
Issued 30 March 2010 Resolved
Remove excess 1 1/2" PVC piping in lazarette.
Condition: Improper Installation
Due 30 March 2010
Resolved 5 April 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 2 February 2009 Resolved
Repair oil leaks (Engine Oil) on both port and starboard engines.
Due 16 February 2009
Resolved 12 February 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 February 2009 Resolved
Replace exhaust lagging on starboard exhaust.
Due 16 February 2009
Resolved 12 February 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 February 2009 Resolved
Properly support electrical lines running to generator (overhead) and starboard battery bank.
Due 16 February 2009
Resolved 12 February 2009
Lifesaving › Lifebuoys › Serviceable
Issued 2 February 2009 Resolved
Replace upper deck life ring.
Due 16 February 2009
Resolved 12 February 2009
Operations/Management › Drills/Instruction › Abandon Ship
Issued 2 February 2009 Resolved
Provide documentation proving fire, man overboard, and abandon ship drills have been completed.
Due 16 February 2009
Resolved 12 February 2009
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 2 February 2009 Resolved
Repair ships whistle.
Due 16 February 2009
Resolved 12 February 2009
Documentation › Markings/Placards › Lifejacket Placard
Issued 2 February 2009 Resolved
Relabel top adult lifejacket placard.
Due 16 February 2009
Resolved 12 February 2009
Documentation › Markings/Placards › Capacity Marking
Issued 2 February 2009 Resolved
Relabel upper deck for maximum number of passengers.
Due 16 February 2009
Resolved 12 February 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 February 2009 Resolved
Remove dirt on soiled life preservers.
Due 16 March 2009
Resolved 12 February 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 February 2009 Resolved
Repair exhaust leak on port side exhaust
Due 16 February 2009
Resolved 20 February 2009
Engineering › Steering Gear System › Rudder
Issued 9 December 2008 Resolved
Replace rudder post seal, and inspect packing IWO port, and starboard rudder post in lazerette.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 December 2008 Resolved
Install fixed ladder for access to forward storage compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 December 2008 Resolved
Install machinery guards on port and starboard MDE's.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 9 December 2008 Resolved
Replace aft cutlass bearings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2008
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 31 March 2008 Resolved
Repair shore tie, both ends have exposed wiring.
Due 30 April 2008
Resolved 28 April 2008
Electrical › Electric Generation Source (service) › Generator
Issued 31 March 2008 Resolved
Replace wasted fuel lines on generator.
Due 30 April 2008
Resolved 28 April 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 March 2008 Resolved
Remove batteries and clean boxes.
Due 30 April 2008
Resolved 28 April 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 March 2008 Resolved
Provide boxes for wiring in A/C room.
Due 30 April 2008
Resolved 28 April 2008
Electrical › Electrical Distribution System (service) › Fuse
Issued 31 March 2008 Resolved
Move items away from fuse boxes.
Due 30 April 2008
Resolved 28 April 2008
Engineering › Steering Gear System › Linkage
Issued 31 March 2008 Resolved
Repair loose steering assembly.
Due 30 April 2008
Resolved 28 April 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 31 March 2008 Resolved
Replace three life jackets, and replace retroreflective tape on 10 type I life preservers.
Due 30 April 2008
Resolved 28 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 31 March 2008 Resolved
Provide drug consortium information for all employees.
Due 30 April 2008
Resolved 28 April 2008
Construction/Loadline › Structures › Door
Issued 31 March 2008 Resolved
Repair water tight hatch for the A/C room.
Due 30 April 2008
Resolved 28 April 2008
Lifesaving › Hand Flares › Expired
Issued 31 March 2008 Resolved
Replace 03 day smoke flares.
Due 30 April 2008
Resolved 28 April 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 March 2007 Resolved
Repair masthead light & clean or repair stern light. COLREGS
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 March 2007
Resolved 13 March 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 12 March 2007 Resolved
Provide proper mounting bracket for B-I located on the navigation bridge. 46CFR176/181
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 30 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 March 2007 Resolved
Remove and properly terminate wires behind navigation console. 46CFR183
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 30 March 2007
Engineering › Bilge Water Management System › Manifold
Issued 12 March 2007 Resolved
Repair bilge manifold valves. 46CFR182
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 March 2007
Resolved 13 March 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 March 2007 Resolved
Replace life ring light. 46CFR181
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 March 2007
Resolved 13 March 2007
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 12 March 2007 Resolved
Captain to obtain Radio Operator [name withheld] 12ARP07.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 30 March 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 12 March 2007 Resolved
Retape retroflective tape on (30) identified lifejackets. 46CFR185
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 30 March 2007
Engineering › Diesel Engine (auxiliary) › Block
Issued 15 May 2006 Resolved
Auxiliary diesel generator prime mover cylinder block damaged (holed) due to failure of internal engine component (cylinder #1). Effect repair/replacement of prime mover. All repairs are to be "IN KIND". Any modification/alterations to the vessel's electrical generating plant must be approved by the cognizant OCMI prior to the completion of work as required by 46 CFR 176.700.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2006
Resolved 18 May 2006
Engineering › Diesel Engine (auxiliary) › Block
Issued 15 May 2006 Resolved
Conduct test(s) of replacement auxiliary diesel generator prime mover as required by 46 CFR 176.702.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2006
Resolved 18 May 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 23 March 2006 Resolved
Provide inspection and maintenance for portable fire appliances.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 27 March 2006
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 23 March 2006 Resolved
Repair port shaft tachometer and prove operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2006
Resolved 27 June 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 23 March 2006 Resolved
Conduct and log drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 March 2006
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 23 March 2006 Resolved
Properly mark emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2006
Resolved 27 March 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 March 2006 Resolved
Remove electrical hazards in galley area (paper stuffing, exhaust fan, junction box, combustibles ect).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2006
Resolved 27 March 2006
Engineering › Sea-water System (primary cooling) › Pump
Issued 23 March 2006 Resolved
Repair raw water-pump starboard MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 March 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 March 2006 Resolved
Secure insulation falling down in electrical compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2006
Resolved 27 March 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 March 2006 Resolved
Properly mark engine room air & fuel shutdowns.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2006
Resolved 27 March 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 April 2005 Resolved
Update navigation publications and provide chart of operating area. 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Construction/Loadline › Structures › Superstructure
Issued 6 April 2005 Resolved
Replace fractured windows in passenger areas (port stern, port and starboard forward). 46 CFR 177.1020.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 6 April 2005 Resolved
Replace retro-reflective tape on lifejackets. 46 CFR 185.604(h).
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 April 2005 Resolved
Replace expired medication in first aid kit. 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Engineering › Bilge Water Management System › Manifold
Issued 6 April 2005 Resolved
Properly mark handles on bilge and fire pump manifold. 46 CFR 181.300.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Engineering › Fuel Oil Service System › Hose
Issued 6 April 2005 Resolved
Replace fuel line from starboard fuel filter to main engine. 46 CFR 176.804.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Fire Fighting › Ventilation Systems › Operating Controls
Issued 6 April 2005 Resolved
Label ventilation shutdown in galley. 46 CFR 182.465.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 April 2005 Resolved
Clean battery boxes and replace battery switch on generator battery cable. 46 CFR 176.806.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 6 April 2005 Resolved
Replace electrical panel cover in pilothouse. 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Resolution: .
Lifesaving › Lifebuoys › Serviceable
Issued 6 April 2005 Resolved
Replace retro-reflective tape on forward ring lifebuoy. Repair or replace aft ring lifebuoy. 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Engineering › Fuel Oil Service System › Valve, Control
Issued 6 April 2005 Resolved
Label location for emergency fuel shutdown handle. 46 CFR 185.608.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 April 2005 Resolved
Properly mount wiring runs and protect from mechanical damage in forward stowage locker.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 11 April 2005
Construction/Loadline › Hull › Bottom Plating
Issued 9 November 2004 Resolved
Easily hammered small hole "approx.. 1 inch diameter hole" just to port of keelson. ISC revealed that wastage was immediately under bilge suction strainer in W/T compartment forward of lazarette. OW/OP to provide repair proposal.
Condition: Unknown
Due 11 November 2004
Resolved 15 November 2004
Resolution: Rcvd SAT repair proposal. Witnessed SAT repair.
Construction/Loadline › Penetrations › Pipe Flange
Issued 9 November 2004 Resolved
Noted both port and starboard stern tubes to be heavily pitted. Remove shaft and couplings for further inspection. Provide repair proposal.
Condition: Unknown
Due 15 November 2004
Resolved 15 November 2004
Resolution: Approximately 6" of stern tubes was cut away to sound metal.
Construction/Loadline › Hull › Bottom Plating
Issued 9 November 2004 Resolved
Noted heavy pitting "approx 1 sq. ft." on hull plating under both port and stdb shaft couplings. Provide repair proposal.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 November 2004
Resolved 15 November 2004
Resolution: Rcvd repair proposal. Witnessed SAT repairs.
Stability › Watertight Integrity › General
Issued 9 November 2004 Resolved
Make all wire penetrations thru watertight bulkhead forward of glass botton viewing area watertight.
Condition: Improper Installation
Due 15 November 2004
Resolved 15 November 2004
Stability › Watertight Integrity › General
Issued 9 November 2004 Resolved
Weld lock nut on hull penetration for deck drain port side.
Condition: Improper Installation
Due 15 November 2004
Resolved 15 November 2004
Resolution: Rcvd repair proposal. Witnessed SAT repair.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 6 April 2004 Resolved
Renew retro tape on 36 lifejackets prior to carrying more than 91 passengers. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 5 May 2004
Resolved 24 November 2004
Engineering › Bilge Water Management System
Issued 6 April 2004 Resolved
Remove excess oil from E/R bilge prior to operation. LEGACY COMPONENT DESC: Oil in Bilge
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2004
Resolution: Owner removed oil.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 6 April 2004 Resolved
Provide First Aid/CPR cards for 50% of the crew LEGACY COMPONENT DESC: CPR Certified Personnel
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 24 November 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 April 2004 Resolved
Provide approved first aid kit IAW 46 CFR 160.041 prior to operation LEGACY COMPONENT DESC: Kit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2004
Resolution: Owner provided approved first aid kit.
Engineering › Fuel Oil Service System
Issued 5 November 2002 Resolved
Repair port and stbd F/O shut off valves. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 12 November 2002
Resolution: Owner repaired port and stbd F/O shut off valves.
Fire Fighting › Fire Pumps
Issued 5 November 2002 Resolved
Renew fire pump gate valve. LEGACY COMPONENT DESC: Arrangement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 12 November 2002
Resolution: Owner renewed fire pump gate valve.
Pollution Prevention/Response › Prevention Equipment
Issued 5 November 2002 Resolved
Repair sewage pump suction piping and tank level indicator. LEGACY COMPONENT DESC: Sewage System Piping
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2002
Resolved 12 November 2002
Resolution: Owner repaired sewage pump suction piping and tank level indicator.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 5 November 2002 Resolved
Renew port main engine exhaust lagging. LEGACY COMPONENT DESC: Silencer (exhaust)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2002
Resolved 12 November 2002
Resolution: Owner renewed port main engine exhaust lagging.
Electrical
Issued 16 March 2001 Resolved
REMOVE UNFUSED 120V POWER OUTLET FROM CIRCUIT BREAKER PANEL IAW 46CFR183.380.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Lifesaving
Issued 16 March 2001 Resolved
REMOVE EXCESS OIL FROM ENGINE ROOM BILGE PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Navigation
Issued 16 March 2001 Resolved
PROVIDE ON BOARD USCG LIGHT LIST IAW 46CFR184.420.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Electrical
Issued 16 March 2001 Resolved
REMOVE WIRE NUTS FROM WIRING IN STEERING CONSOLE IAW 46CFR183.340.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Lifesaving
Issued 16 March 2001 Resolved
RENEW FWD RING LIFE BUOY REQUIRED BY 46CFR180.70, PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Lifesaving
Issued 16 March 2001 Resolved
RENEW/ADD 17 ADULT PFDs PRIOR TO CARRYING MORE THAN 158 PASSENGERS, IAW 46CFR180.71.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Lifesaving
Issued 10 March 2000 Resolved
46 CFR 185.420 - ENSURE EXISTING CREWMEMBERS SATISFACTORY PERFORM THE FOLLOWING DRILLS EVERY THREE MONTHS AND ALL NEW CREWMEMBERS UPON HIRE AND LOG TESTS: MAN OVERBOARD, FIRE FIGHTING, ABANDON SHIP.
Condition: Unknown
Due 10 March 2000
Resolved 5 July 2000
Lifesaving
Issued 10 March 2000 Resolved
46 CFR 180.175 - RENEW WATERLIGHT BATTERY IN LIFE FLOAT.
Condition: Unknown
Due 10 March 2000
Resolved 5 July 2000
Lifesaving
Issued 10 March 2000 Resolved
46 CFR 185.604 - RENEW RETOR TAPE ON PFDS AND RING BUOY.
Condition: Unknown
Due 10 March 2000
Resolved 5 July 2000
Lifesaving
Issued 10 March 2000 Resolved
46 CFR 180.200 - RENEW LIFE FLOATS TO ORIGINAL CONDITION.
Condition: Unknown
Due 10 March 2000
Resolved 5 July 2000
Lifesaving
Issued 10 March 2000 Resolved
46 CFR 180 - PROPERLY STOW LIFE FLOAT'S SEA PAINTER.
Condition: Unknown
Due 10 March 2000
Resolved 5 July 2000
Navigation
Issued 10 March 2000 Resolved
46 CFR 184.420 - HAVE ONBOARD AND MAINTAIN CURRENT COPIES OF THE REQUIRED PUBLICATIONS.
Condition: Unknown
Due 10 March 2000
Resolved 5 July 2000
Lifesaving
Issued 4 March 1993 Resolved
RENEW WORN LINE THAT ATTACHES WATERLIGHT TO RING BUOY.
Condition: Unknown
Due 4 March 1993
Resolved 4 March 1993
Engineering
Issued 4 March 1993 Resolved
REPAIR LEAK ON STBD MAIN DIESEL ENGINE EXHAUST PIPING IN WAY OF FLEXIBLE COUPLING.
Condition: Unknown
Due 4 March 1993
Resolved 4 March 1993
Lifesaving
Issued 4 March 1993 Resolved
RENEW BRACKET FOR BOW RING BUOY WATERLIGHT
Condition: Unknown
Due 4 March 1993
Resolved 4 March 1993
Unknown
Issued 16 February 1990 Resolved
PROVE PROPER OPERATION OF BELT DRIVE MANIFOLD BILGE/FIRE PUMP.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Unknown
Issued 16 February 1990 Resolved
REMOVE ALL OILY WATER FROM ENGINE ROOM BILGE AREA.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Unknown
Issued 16 February 1990 Resolved
PROVE PROPER OPERATION OF ELECTRIC MANIFOLD BILGE/FIRE PUMP.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Documentation
Issued 18 February 1987 Resolved
PROVIDE & PLACE ONBOARD VALID FCC SHIP/AIRCRAFT RADIO STATION LICENSE.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987

Casualty record · 3

23 March 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2610611
14 May 2006Routine · role: Involved in a Marine Casualty · activity 2664382
29 June 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 3 injured · activity 3518708
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.