MARIE

MARIE is a 1982 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 1985, most recently in June 2026, along with 67 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 15 June 2026.

Built
1982
Last inspected
15 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

232694
Flag
UNITED STATES
—
Maury page id
psix-232694

Inspections, by type

…with no type recorded3
Years with a record 36 calendar years (1985–2026)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it1 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 45

15 June 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8404915
16 June 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8160067
9 May 2024 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7908836
6 July 2023 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7715524
1 June 2022 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7457512
3 August 2021 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7275587
2 July 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7275503
24 June 2019 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6723629
28 May 2019 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6696877
10 May 2019 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6680991
31 July 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6484116
30 May 2017 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6168766
27 January 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6078409
9 May 2014 Deficiency Check · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4856646
25 January 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3932820
16 April 2009 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3458297
8 September 2008 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3317782
11 September 2007 Internal Structural Exam · Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3060715
23 October 2006 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2806577
29 August 2005 Hull Examination · Internal Structural Exam · Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2478277
9 September 2004 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2190979
3 September 2003 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1895379
27 August 2003 Administrative Inspection
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1888666
28 May 2002 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1619388
18 May 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1449469
11 May 2001 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1415607
19 May 2000 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1391330
20 July 1999 Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1448088
5 August 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1131132
22 May 1997 Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1103202
18 October 1996 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 838161
9 June 1994 Deficiency Check · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1354747
3 May 1994 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1354746
8 June 1993 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1469754
8 July 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1268709
16 June 1992 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 944510
3 June 1991 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 917077
7 May 1991 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1231849
31 May 1990 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 922149
5 June 1989 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1198098
1 June 1988 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1044958
3 June 1987 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1027328
28 May 1986 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 990999
24 May 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 984060
16 May 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 981695

Deficiency record · 67

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2026 Resolved
At least on ring life buoy must be fitted with a lifeline... must carry one floating water light, unless it is it is limited to day time operation. MI's observed vessel's life buoy lifeline frayed and water light inoperable. Replace life ring or line, and water light in kind. 46 CFR 180.70(c) & (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 29 June 2026
Resolution: Rectified. New life ring and water light were installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2026 Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crew-members on inspected vessels who... Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. MI's observed no Drug & Alcohol program Consortium and test results. Provide DAPI enrollment and list of crewmembers random test. 46 CFR 16.230(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 29 June 2026
Resolution: Rectified. Provided proof of DAPI and crew test results.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 July 2023 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel did not have COI on-board and is currently missing its COI. Vessel must maintain copy sent by Coast Guard on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 8 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 July 2023 Resolved
Each rescue boat and ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Vessels life buoy did not have retro-reflective tape.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 8 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2023 Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. intake hose only had one hose clamp attached.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 26 July 2023
Resolution: Received photographic evidence of rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2021 Resolved
Each ring life buoy on a vessel must be in good condition and approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant. MI discovered that the vessel's life ring was deteriorating/exposed parts of life ring's floatation effecting its seaworthiness. 46 CFR 180.70 (b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2021
Resolved 27 August 2021
Resolution: Received photograph from operator displaying a new ring life buoy onboard MARIE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 May 2019 Resolved
Vessel does not have a high level bilge alarm installed in the engine compartment. Install high level bilge alarm in space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2019
Resolution: Installed high level bilge alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2019 Resolved
The markings for life jacket stowage are too small and missing quantity marking. Properly mark life jacket stowage location with 2" lettering and numbers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2019
Resolution: Properly marked life jacket stowage.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 May 2019 Resolved
B-II portable fire extinguisher is severly corroded. Replace with a type 40 B:C portable fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2019
Resolution: Operatore purchased and installed new portable fire extinguisher.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 7 June 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2017
Resolution: Deficiency cleared and replaced with revised deficiency #6
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 7 June 2017 Resolved
Provide means for keeping passenger count of passengers that embark and disembark vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 31 July 2017
Resolution: System now in place.
Lifesaving › Lifebuoys › Stowage
Issued 7 June 2017 Resolved
Provide corrosion resistant clip for floating light lanyard and affix new retro-tape around body of ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 5 July 2017
Resolution: Received proper photo documentation of new clip affixed to life ring body, and new retro tape.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 7 June 2017 Resolved
Properly mount fire extinguishers in approved marine brackets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 5 July 2017
Resolution: Received proper photo documentation of new marine brackets affixed to the vessel for fire extinguishers.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 June 2017 Resolved
Conduct and log man overboard and fire drills in the presence of the Coast Guard and properly log all drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2017
Resolution: Satisfactory drills were conducted.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 7 June 2017 Resolved
Prove progress towards updating master's MMC to reflect the proper operating AOR.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 25 August 2017
Resolution: NMC to issue corrected MMC.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 January 2017 Resolved
Vessel must complete a COI inspection prior to operating with passengers; vsl missed 2015 and 2016 annual inspections.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2017
Resolution: Completed required COI inspection.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 May 2014 Resolved
Service Fire Extinguishers
Action required: 705 - Other - as specified
Due 16 May 2014
Resolved 14 May 2014
Resolution: Fire extinguishers serviced
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 May 2014 Resolved
Replace Battery to life ring water light, Vessel restricted to daylight operation
Action required: 705 - Other - as specified
Resolved 14 May 2014
Resolution: Battery replaced
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 May 2014 Resolved
Conduct and document supervisory drug/alcohol awareness training
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 28 May 2014
Resolution: Recieved certificate attesting to completion of training
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 29 November 2010 Resolved
[name withheld] granted an extension to the exam reqs. However, prior to carrying passengers the vessel SHALL conduct an ann insp to the satisfaction of the attending USCG MI. The ann insp is for the vessel to be in compliance with the last ann insp that was due on Sept 2010 (2nd annual). The vessel will still need to be scheduled for its third ann exam that will be due in Sept 2011.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2011
Resolution: Conducted second annual inspection.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 16 April 2009 Resolved
Replace cutlass bearing on shaft.
Action required: 705 - Other - as specified
Due 23 April 2009
Resolved 12 May 2009
Resolution: Received invoice for replacement cutlass bearing was received via fax.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 September 2008 Resolved
Provide proof of crew enrollment in drug and alcohol testing consortium.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2008
Resolution: Vessel provided proof of enrollment.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 8 September 2008 Resolved
Provide emergency instructions (Regarding man overboard, fire an rough weather at sea.)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2008
Resolution: Vessel provided emergency instructions.
Operations/Management › Passenger Operations › Safety Orientation
Issued 8 September 2008 Resolved
Provide proper means of maintaining passenger count.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2008
Lifesaving › Lifejacket/PFD (Type III) › Marking
Issued 8 September 2008 Resolved
Stencil vessel name on lifejackets as indicated by marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 October 2008
Resolved 10 September 2008
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 8 September 2008 Resolved
Replace exhaust hose IWO engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 October 2008
Resolved 10 September 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 September 2008 Resolved
Provide proof of servicing of portable fire extinguisher. (2-BII)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2008
Fire Fighting › Fire Bucket › Availability
Issued 8 September 2008 Resolved
Provide two additional fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2008
Resolution: Fire buckets were provided.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 11 September 2007 Resolved
Replace seal IWO BII fire extinguisher starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 7 November 2007
Fire Fighting › Fire Bucket › Stenciling
Issued 11 September 2007 Resolved
Stencil “Fire Bucket” on all vessels fire buckets.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 7 November 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 September 2007 Resolved
Prove proper operation of floating waterlight IWO ring lifebuoy.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 15 November 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 September 2007 Resolved
Provide 02 additional adult PFD’s.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 7 November 2007
Construction/Loadline › Structures › Trunk
Issued 11 September 2007 Resolved
Make proper repairs to aft seat hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 7 November 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 September 2007 Resolved
Provide vessel/drill log book (hard bound) .
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 7 November 2007
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 September 2007 Resolved
Provide appropriate nautical publications IAW (46CFR 184.420)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 7 November 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 September 2007 Resolved
RG08 – Provide emergency lighting (flash light).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 7 November 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 October 2006 Resolved
Stencil vessel name on ring life buoy.
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 28 November 2006
Resolution: Received written confirmation markings made as required.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 October 2006 Resolved
Provide life line for ring life buoy.
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 28 November 2006
Resolution: Received written confirmation life line installed as required.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 October 2006 Resolved
Provide waterlight for ring life buoy.
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 28 November 2006
Resolution: Received written confirmation waterlight purchased and installed as required.
Lifesaving › Lifejacket/PFD (Type I)
Issued 3 September 2003 Resolved
Provide one (1) type I PFD. Vsl restricted to carrying 11 passengers. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 26 January 2004
Documentation › Certificates/Documents
Issued 3 September 2003 Resolved
Provide proof of DAPI consortium contract. Vsl restricted from carrying passengers. LEGACY COMPONENT DESC: DAPI Contract
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 12 September 2003
Documentation › Markings/Placards
Issued 3 September 2003 Resolved
Provide donning placard for all type of PFD's O/B. LEGACY COMPONENT DESC: Donning Placard
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 September 2003
Resolved 26 January 2004
Electrical › Electric Supply System (service) › Cable
Issued 28 May 2002 Resolved
Address the wire connections in the shaft areas and the rudder post area.
Due 19 June 2002
Resolved 19 June 2002
Resolution: Resecured the wires joints with the proper wire connectors
Electrical › Lighting (emergency)
Issued 28 May 2002 Resolved
Provide portable lighting.
Due 19 June 2002
Resolved 19 June 2002
Resolution: Supplied a new flashlight.
Electrical › Electrical Distribution System (service)
Issued 28 May 2002 Resolved
Repair the port and starboard running lights
Due 19 June 2002
Resolved 19 June 2002
Resolution: Installed new lamps
Lifesaving › Buoyant Apparatus
Issued 28 May 2002 Resolved
Replace (01) child life jackets and (09) adult life jackets. The passenger count is reduced till the life jackets are replaced and inspected to the OCMI approval.
Due 19 June 2002
Resolved 19 June 2002
Resolution: Replaced the faulty life jackets with new ones. They labeled them on the bottom with the present name with small letters because the have a bid out for a new launch which will have a different name for next year.
Lifesaving › Buoyant Apparatus
Issued 28 May 2002 Resolved
Re-tro fit reflective tape around the life ring
Due 19 June 2002
Resolved 19 June 2002
Resolution: They fitted the present ring with the new reflective tape
Engineering › Steering Gear System › Rudder
Issued 28 May 2002 Resolved
Stop the excesive water leakage around the rudder post packing gland.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2002
Resolved 19 June 2002
Resolution: Added another ring of packing to the rudder post.
Engineering › Bilge Water Management System › Pump
Issued 28 May 2002 Resolved
Provide a portable bilge pump
Due 19 June 2002
Resolved 19 June 2002
Resolution: New one installed on board near the rudder post.
Accommodation/Occupational Safety › Medical/First Aid
Issued 28 May 2002 Resolved
Provide a updated first aid kit
Due 19 June 2002
Resolved 19 June 2002
Unknown
Issued 19 May 2000 Resolved
Provide approved lifering.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Unknown
Issued 19 May 2000 Resolved
Provide approved waterlight with bracket and line with snap hook.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Unknown
Issued 19 May 2000 Resolved
Provide emergancy instructions.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Unknown
Issued 19 May 2000 Resolved
provide vessel and training log book.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Lifesaving
Issued 9 June 1994 Resolved
ENSURE ALL PFD'S STENCILED WITH VESSEL NAME.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Unknown
Issued 9 June 1994 Resolved
PROVIDE PROOF OF ENROLLMENT IN A RANDOM DRUG TESTING PROGRAM OF ALL VESSEL OPERATORS.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Documentation
Issued 8 June 1993 Resolved
PROVIDE PROOF OF ENROLLMENT IN A PRE-EMPLOYMENT AND RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Fire Fighting
Issued 8 July 1992 Resolved
PROVIDE ADDITIONAL B-I FIRE EXTINGUISHER AT HELM STATION.
Condition: Unknown
Due 23 July 1992
Resolved 23 July 1992
Fire Fighting
Issued 8 July 1992 Resolved
PROVIDE PROPER BRACKETS AS REQUIRED BY EXT. APPROVAL LABEL.
Condition: Unknown
Due 23 July 1992
Resolved 23 July 1992
Fire Fighting
Issued 16 June 1992 Resolved
VESSEL MISSING ONE B-I HAND PORTABLE FIRE EXTINGUISHER AS REQUIRED BY COI._x001C_SPOKE WITH CID AND WILL AMEND COI TO DROP REQUIREMENT FOR THIS EXTINGUISHERDUE TO THE CLOSE PROXIMITY OF TWO B-II HAND PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Navigation
Issued 16 June 1992 Resolved
RED LENSE FOR PORT SIDE LIGHT INSTALLED IN HULL HAS FADED AND IS SHOWING WHITE.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Electrical
Issued 16 June 1992 Resolved
VESSEL HAS NOT EMERGENCY MEANS OF LIGHTING ON BOARD WHICH IS SEPARATE FROM THE INSTALLED 12 VOLT SYSTEM.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Lifesaving
Issued 16 June 1992 Resolved
METALIC RIVITS ON METALIC SNAPS OF METALIC STRAP FASTNERS WASTED DUE TO LACK OF PROPER MAINTAINANCE.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Electrical
Issued 16 June 1992 Resolved
VESSEL HAS ONLY ONE BATTERY ON BOARD LOCATED IN ENG. SPACE. THIS BATTERY IS NOT SECURED FROM MOVEMENT AND THE TERMINALS ARE NOT PROTECTED FROM ACCIDENTAL CONTACT.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Documentation
Issued 16 June 1992 Resolved
NO EMERGENCY CHECK OFF LIST WAS POSTED OR AVAILABLE ON BOARD.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Electrical
Issued 16 June 1992 Resolved
ELECTRIC BILGE PUMP NOT INSTALLED IN EXISTING SYSTEM. NEW PUMP IS TO INSTALLED BUT DUE TO VSL LENGTH ELECTRIC PUMP NOT REQUIRED. VLS HAS A SUITABLE HAND BILGE PUMP.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Fire Fighting
Issued 16 June 1992 Resolved
TWO B-II HAND PORTABLE EXTINGUISHERS MOUNTED IN JURY RIGGED BRACKETS THAT FAILED WHEN ATTEMPTS TO REMOVE EXTINGUISHERS FROM THEM. REQUIRE BRACKETS TO MAINTAIN CG APPROVAL VALIDITY.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.