MAURY USCG vessel records
← All vessels

AMERICAN EAGLE

Built
1984
Last inspected
13 October 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 October 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE5396
232702
Flag
UNITED STATES
Maury page id
psix-232702

Documentation record

Registered dimensions (L × B × D)78.9 ft × 28.5 ft × 9.0 ft
Registered tonnagegross 78 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNICHOLS BROTHERS BOAT · FREELAND, WA, UNITED STATES · built 1984
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portJUNEAU, AK
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 2 February 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Simplified, Net Ton
78 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 35 inspections, each with its date, unit and type; 70 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 35

13 October 2025 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8254220
5 August 2025 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8203073
19 July 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8189189
19 May 2025 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8139432
10 May 2024 COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7910998
16 September 2022 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7565318
28 May 2020 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6962935
28 February 2020 Drydock Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6917921
22 October 2019 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6842189
18 August 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6788813
12 June 2019 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6712273
10 June 2019 Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6710611
18 May 2019 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6688947
30 April 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6674704
12 April 2019 COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6661584
6 November 2018 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6576028
16 August 2018 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6515186
23 April 2018 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6398899
19 April 2018 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6399600
4 April 2018 Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6386935
13 March 2018 Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6370592
31 January 2018 Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6347412
9 January 2018 Permit to Proceed
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6335210
11 October 2017 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6285929
8 August 2017 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6234485
16 May 2017 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6147067
14 November 2016 In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6039787
13 October 2016 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6022169
2 July 2016 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5931895
16 May 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5878887
29 April 2016 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5868327
14 April 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5854178
11 April 2016 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5859828
9 February 2016 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5859822
26 January 2016 Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5803898

Deficiency record · 70

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 August 2025 Resolved
Means of escape must be widely separated and, if possible, at opposite ends or sides of the space. 46 CFR 177.500 Mark forward door with "Emergency Exit" placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2025
Resolved 6 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 August 2025 Resolved
An inflatable liferaft or inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant no later than the month and year on its servicing sticker. 46 CFR 185.730. Provide servicing report for all liferafts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2025
Resolved 12 August 2025
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 5 August 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards and electrical shock. 46 CFR 183.200 Provide protection on 24 volt lugs in Port Engine room at 30 amp breaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2025
Resolved 13 October 2025
Resolution: Suitable protection for wiring lugs was provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 5 August 2025 Resolved
Operation of transmittal ship station must be performed by a person holding a commercial operator license or permit. 47 CFR 80.155. Provide evidence of FCC Radio Operator Permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. It was reported that one of the engines on vessel was overheating. Repair the engine in kind and demonstrate the proper operation of the engines to the satisfaction of the attending marine inspector. 46 CFR 182.200 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2025
Resolution: Raw water pump replaced; all sat. Conducted sat sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2025 Resolved
A vessel must be provided with a main steering gear that is:(1) Of adequate strength and capable of steering the vessel at all service speeds;(2) Designed to operate at maximum astern speed without being damaged or jammed; and(3) Capable of moving the rudder from 35 degrees on one side to 30 degrees on the other side in not more than 28 seconds with the vessel moving ahead at maximum service speed. It was reported that the vessel lost steering when securing an overheating engine. Identify the cause of loss of steering repair/restore steering. Demonstrate the proper operations of steering under all conditions designed to the satisfaction of attending marine inspector. 46 CFR 182.610 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2025
Resolution: Replaced stbd steering pump and hydraulic control valved; all sat. Conducted sat sea /steering trial.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 May 2025 Resolved
Lifesaving- (b) Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel is currently limited to carry 146 passengers and 4 crew members or 150 persons total on board until the 6 person life raft has received servicing and returned to vessel. 46CFR 176.808(b)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 4 June 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 May 2024 Resolved
The minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Starboard fire pump only achieved 40psi at testing. 46 CFR 181.300(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2024
Resolution: Fire pump was retested and achieved 60PSI at the pump.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 May 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Vessels fixed fire fighting system pressure switches did not shut down the generators at testing. 46 CFR 176.810(a) 46 CFR 176.810(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2024
Resolution: Pressure switches secured both generators at retesting.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 May 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Fire detection system had not been serviced. 46 CFR 176.810(a)(7)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2024
Resolution: Local fire system servicing company inspected the fire detection system.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 May 2024 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Port hull overhead light was extinguished and was missing the required guard. 46 CFR 183.410(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2024
Resolution: Light was replaced and a guard was installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 May 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Pump in port hull CO2 space has wires exposed and is missing the cover plate. 46 CFR 183.200(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2024
Resolution: Cover plate was installed on the electrical enclosure for the pump.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 May 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Electrical panel on the bridge and in the port engine room had open spaces inside the panel. 46 CFR 183.200(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2024
Resolution: Blanks were installed in openings.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 10 May 2024 Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel did not have name on the bow or stern. 46 CFR 67.123
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2024
Resolution: Vessel name was placed on bow and stern of the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 May 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Anchor light had significant UV damage and was showing an amber color and not white. 46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2024
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 10 May 2024 Resolved
Prior to carrying passengers, mob, fire and abandon ship drills must be conducted to the satisfaction CG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 May 2024 Resolved
Prior to carrying passengers, prove proper operation of the vessels propulsion and steering systems to the satisfaction of a CG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 February 2020 Resolved
Watertight hatch seal on Port side CO2 room is cracked and worn.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Watertight hatch gasket was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 October 2019 Resolved
Prove proper operation of all Starboard ventilation and port lower aft ventilation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2024
Resolution: Port and starboard ventilation functions properly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 October 2019 Resolved
Make port engine room ventilation trunk vapor tight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2020
Resolution: vessel has repaired ventilation trunk, all sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 October 2019 Resolved
Prove port side time delays meets 30 seconds. Time delay tripped at 26 seconds
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2024
Resolution: Time delay tested sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 October 2019 Resolved
Prove port side engine secures when CO2 is activated
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2024
Resolution: Port engine secures properly when tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 October 2019 Resolved
Repair exhaust leak on starboard engine prior to operating engine.
Action required: 705 - Other - as specified
Due 22 February 2020
Resolved 24 February 2020
Resolution: Vessel has temp repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 October 2019 Resolved
Make port side engine room trunk weather/vapor tight during this years Drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Trunk was made water/vapor tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 October 2019 Resolved
Make permanent repairs starboard engine exhaust bellows prior to carrying passengers. Vessel has spot welded pinhole in top of bellows.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: exhaust bellow were replaced in kind.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 April 2019 Resolved
Submit fire detection system plans to Commanding Officer MSC for review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 12 June 2019
Resolution: Fire dection plans reviewed and approved by MSC.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 April 2019 Resolved
A space containing propulsion machinery which is not manned or contain a fixed system that can not automatically discharge upon detection of heat must be equipped with a fire detection system; no detection system is provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2019
Resolved 29 April 2019
Resolution: Verified installation and witnessed a function test of the newly installed fire detection system. Provided a seperate def to submit plans to MSC.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 12 April 2019 Resolved
CO2 sirens must be clearly marked "When alarms sound-Vacate at once. Carbon dioxide being released."; no signs were provided for either engine room.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 26 April 2019
Resolution: Verified signs were provided in the vicinity of the siren.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2019 Resolved
A vessel must be provided with arrangement for draining a watertight compartment; the fwd bilge manifold valve handle in the starboard engine room was wasted off of the stem.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 26 April 2019
Resolution: Verified a valve handle was provide and witnessed a satisfactory function test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2019 Resolved
A vessel must have visual and audible alarm to indicate a bilge high water level; both port and starboard engine room bilge alarms were inoperable.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 29 April 2019
Resolution: Witnessed a satisfactory function test for the bilge alarms in both engine rooms.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 12 April 2019 Resolved
A space storing CO2 cylinders must be conspicuously marked "Carbon dioxide gas can cause injury or death. Ventilate the area before entering. A high concentration can occur in this area and can cause suffocation."; no signs were provided at p&s voids storing the cylinders.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 26 April 2019
Resolution: Verified signs were provided at the entrance to both voids storing CO2 cylinders.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 12 April 2019 Resolved
The most current stability letter must be posted at the operating station; the existing posted stability letter had been superceded.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 26 April 2019
Resolution: Verified the most current stability letter was provided and posted in the operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 12 April 2019 Resolved
Vessel with passenger limitations on upper decks must be indicated at entranceway to that deck; passenger limitation signs were improperly located and not reflective of the number on the stability letter.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 26 April 2019
Resolution: Verfied the second and third deck passenger limitations were provided at the entry of each deck.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 12 April 2019 Resolved
Exposed hazards must be properly protected by a cover; the port engine fuel pump rotary drive was exposed.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 26 April 2019
Resolution: Verfied the rotating machinery was provided with a cover.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 April 2019 Resolved
Electrical components used in a machinery space must be dripproof; the 110V distribution panel at the base of the entryway ladder in the port engine room was not provided with a drip shield.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 26 April 2019
Resolution: Verified the identified panel was provided with a drip shield.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 April 2019 Resolved
Life jacket storage locations must be marked with size and quantity; adult and children life jacket storage on the second deck was not properly marked.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 26 April 2019
Resolution: Verified the identified life jacket storage locations were properly marked.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 April 2019 Resolved
EPIRB's must have a current registration; the vessel's EPIRB registration was expired.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 26 April 2019
Resolution: Verified the vessel's EPIRB was provided with a current NOAA registration.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 12 April 2019 Resolved
The vessel's name must be clearly visible on the exterior part of the port and starboard bow; the vessel's name was was worn and illegible.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 18 May 2019
Resolution: Vessel has remarked both bows, all sat
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 12 April 2019 Resolved
Conduct underway drills prior to seasonal operations.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 30 April 2019
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 19 April 2018 Resolved
A pressure relief valve or equivalent set between 2400 and 2800psi must be installed in the distribution manifold, a relief device is not currently provided.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2018
Resolution: Vessel hads installed pressure relief valve
Documentation › Certificates/Documents › Stability Letter
Issued 13 March 2018 Resolved
Post the most current stability letter in the operating station.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 23 April 2018
Resolution: Verified the most current stability letter was provided and posted onboard.
Documentation › Markings/Placards › Capacity Marking
Issued 13 March 2018 Resolved
Provide signs reflecting proper stability letter passenger quantity restrictions for both upper decks at the entrance to each deck. 80 persons on the second deck and 30 for the third.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 23 April 2018
Resolution: Verified second and third decks were appropriately marked.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 13 March 2018 Resolved
Provide serviced liferafts of sufficient capacity.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 23 April 2018
Resolution: Verified appropriate primary lifesaving equipment was provided.
Engineering › Steering Gear System › Actuator
Issued 13 March 2018 Resolved
Repair and conduct operational test of the vessel's steering system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 23 April 2018
Resolution: Vessel was outfitted with a new port and starboard engine driven hydraulic steering system to include pumps, flow controls, and hoses. Operational test sat.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 13 March 2018 Resolved
Repair and conduct an operational test of the vessel's starboard main diesel engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 23 April 2018
Resolution: Witnessed an opeational test of the starboard main diesel engine, all sat.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 13 March 2018 Resolved
Provide non-conductive matting on the deck in front of the vessel's switchboard.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 23 April 2018
Resolution: Vessel's switchboard was provided with a non-conducttive mat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 March 2018 Resolved
Repair the port main deck handrail in way of the forward cabin.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 23 April 2018
Resolution: Verfied port deck rail was repaired.
Stability › Weathertight Integrity › General
Issued 13 March 2018 Resolved
Make stbd lazarette hatch weather tight.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 23 April 2018
Resolution: Verfied hatch was properly serviced and adjusted.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 March 2018 Resolved
Conduct underway drills.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 17 August 2018
Resolution: Conducted u/w drills all sat.
Engineering › Bilge Water Management System › Pump
Issued 13 March 2018 Resolved
Troubleshoot, repair, and conduct an operational test of the bilge pumping system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 23 April 2018
Resolution: Port bilge pump was identified as wired backwards. Witnessed an operational test of the vessel's bilge pumping system; all, sat.
Construction/Loadline › Hull › Keel Plate
Issued 31 January 2018 Resolved
Identified inadequate hull repair and suspected fracture located along the upper stem in the #1 void of the port hull. Provide proposal to conduct permanent repairs.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 8 February 2018
Resolution: Affected area was cropped and renewed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 31 January 2018 Resolved
Provide proper bilge level sensor wiring bulkhead penetrations for the bulkhead separating the #2 and #3 void in both hulls.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 8 February 2018
Resolution: Verfied installation of wiring penetration.
Construction/Loadline › Structures › Superstructure
Issued 31 January 2018 Resolved
Provide missing mounting hardware for the two forward vibration isolator superstructure mounts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 8 February 2018
Resolution: Previous hardware was identified to have backed out. Verified installation of new hardware.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 11 October 2017 Resolved
Starboard time delay failed twice with tripping at 23 sec. and 24.5 under required 30 seconds.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2018
Resolution: Witnessed installation and testing of a new CO2 fire suppression system for both the port and starboard engine rooms.
Lifesaving › Inflatable Buoyant Apparatus › Capacity
Issued 16 May 2017 Resolved
Provide a sufficient number of IBA's for the permitted crew and passengers. Maximum occupancy limited to 150.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 17 May 2017
Resolution: Witnessed properly installed 6 man IBA.
Communications › Radio Communications › EPIRB
Issued 16 May 2017 Resolved
Affix NOAA registratio sticker to EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 17 May 2017
Resolution: Witnessed EPIRB registration sticker fixed to EPIRB.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 May 2017 Resolved
Provide current Certificate of Documentation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 17 May 2017
Resolution: Witnessed current COD onboard.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 May 2017 Resolved
Provide current nautical charts and Coast Pilot for the vessel's area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 17 May 2017
Resolution: Witnessed new charts for operating area prior to conducting drills.
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 May 2017 Resolved
Conduct drills as required by attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 17 May 2017
Resolution: Conducted drills in Auke Bay.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 May 2017 Resolved
Affix SPV Decal at a place readily visible to passengers.
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 17 May 2017
Resolution: Winessed Decal affixed to vessel window.
Engineering › Bilge Water Management System › Pump
Issued 16 May 2017 Resolved
Demonstrate operation of the port bilge pump and hull cross connect.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2017
Resolved 17 May 2017
Resolution: Witnessed bilge pump and cross connect operated properly.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 16 May 2017 Resolved
Vessel operator provide proof of license.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 17 May 2017
Resolution: Witnessed master's license prior to conducting drills.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 13 October 2016 Resolved
Relocate the two pressure switches for the fixed CO2 suppression system for the Port & STBD engineroom as per MTN 01-04 - 16715 22 Sept 2004 & Marine Safety Alert Inspections & Compliance Directorate Alert 05-12 & 6-15.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 16 May 2017
Resolution: Verified pressure switch relocation to the lazzarette for both hulls.
Engineering › Bilge Water Management System › Pump
Issued 14 April 2016 Resolved
Stbd side bilge pump has been removed for repairs. This renders the crossover capabilities of the bilge system inoperable and also removes its use as a back up fire pump.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2016
Resolved 16 May 2016
Resolution: Owner installed a brand new bilge/fire pump in place of the defective pump - Tested SAT.
Fire Fighting › Fire Main › Pressure
Issued 14 April 2016 Resolved
Fire main appears to have a blockage. The pump makes pressure but no water is available to the hoses. Vessel must prove proper operation of the fire main system and test the hoses to a USCG marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2016
Resolved 29 April 2016
Resolution: A valve was found to be closed limiting the flow of water to the hydrants. Hydrants and hoses all tested sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2016 Resolved
Complete first aid kit not present. Referred Port Captain to Q Spec 160.041 for list of required items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 16 May 2016
Resolution: Owner replaced missing and/or expired items in vsl's first aid kit - SAT.
Lifesaving › Lifebuoys › Serviceable
Issued 14 April 2016 Resolved
Replace deteriorated life ring Retro Reflective tape on 2 of the life rings.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 29 April 2016
Resolution: New tape was added to life buoys.
Engineering › Steering Gear System › Rudder
Issued 9 February 2016 Resolved
Port rudder freely moves due to wasted control arm. Replace wasted control arm and prove proper operation of steering. 46CFR176.802
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 21 April 2016
Construction/Loadline › Hull › Weld
Issued 26 January 2016 Resolved
Assess leak located in starboard lazarette, 3rd void from stern, located in shaft alley, inboard side near most foward bulkhead.
Action required: 705 - Other - as specified
Due 9 February 2016
Resolved 3 March 2016
Resolution: Leak has been located and repaired by cropping and renewing hull plating.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 January 2016 Resolved
Assess splash zone patch located in starboard lazarette, 3rd void from the stern, outboard side, on the aft bulkhead near port side corner.
Action required: 705 - Other - as specified
Due 9 February 2016
Resolved 18 February 2016
Resolution: Examined 3" circular splash zone patch and identified that it covered 1/2" watertight bulkhead penetration between aft two starboard voids.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.