MAURY USCG vessel records Sign in
← All vessels

KASHIMA BAY

KASHIMA BAY is a 1984 freight ship. The Coast Guard has recorded 33 inspections since 1984, most recently in May 2014, along with 22 deficiencies — 3 with no resolution recorded — and 2 operational controls.

Records from 1984 to 2014. Most recent: inspection, 1 May 2014.

Built
1984
Last inspected
1 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8213603 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
232709
Flag
PANAMA
—
Maury page id
psix-232709

Inspections, by type

…with no type recorded22
…past their stated due date3
Years with a record 17 calendar years (1984–2014)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it9273 - Convention (Subpart B), Gross Ton
16150 - Displacement, Ton
10664 - Dead Weight, Ton
4593 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

1 May 2014 PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4842570
10 July 2011 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4076261
3 July 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4066962
27 July 2009 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3547286
2 January 2009 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3387715
30 April 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3352156
10 October 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3076697
20 July 2007 ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2996702
16 July 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2997068
22 August 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2756151
13 May 2006 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2648173
5 April 2006 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2617067
4 November 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2528448
2 January 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1725797
5 March 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 117753
4 March 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 413399
7 November 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 397099
10 June 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 391945
16 December 1994 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 485653
16 December 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1153253
6 June 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 656427
29 May 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 367349
29 May 1994 MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1171414
13 August 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 649589
17 October 1988 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 326282
27 January 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 321020
10 November 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 319507
30 July 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 491603
29 January 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 306618
26 August 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 509747
13 March 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 300773
27 February 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 300559
1 October 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 525887

Deficiency record · 22

Construction/Loadline › Structures › Air Pipe
Issued 1 May 2014 No resolution recorded
1299- Where pipes to ballast tanks extend above freeboard or superstructer decks pipes should be of substantial construction. The sounding pipe for the number three starboard wing ballast tank was found to be holed. ICLL Annex 1 Reg. 20, 16 a,c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2014 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer (solid) › General
Issued 1 May 2014 No resolution recorded
1150-After any survey of the ship, no change shall be made to the structural arrangements, machinery, equipment or other items covered by the survey without sanction of the Administration. PSC examiners found two wire ropes on the number three crane to be flattened. 74 SOLAS (09 CONS. ED) 1/ Reg 11, 16 a,c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2014 — due date passed with no resolution recorded
Engineering › Steam Boiler (auxiliary/waste heat) › Water Drum/Header
Issued 1 May 2014 No resolution recorded
1499- After any survey of the ship, no change shall be made to the structural arrangements, machinery, equipment or other items covered by the survey without sanction of the Administration. Auxiliary Boiler condensation tank found to be wasted. 74 SOLAS (09 Cons. Ed) Chp 1/ Reg 11, 16 a,c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2014 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 July 2011 Resolved
Upon inspection and testing of the OWS system numerous water leaks were found around seals. No change is machinery shall be made without sanction from the administration.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 August 2011
Resolved 7 September 2012
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. The attending NKK surveyor stated that he witnessed satisfactory operation of the OWS after it was overhauled by the crew.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 3 July 2011 Resolved
Upon inspection the C/E could not provide his national license. Every officer of an engineering watch shall hold an appropriate certificate.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2011
Resolved 28 July 2011
Resolution: The C/E provided acceptable documentation of his Romainian License
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 6 January 2009 Resolved
2120 - MARPOL related operational defic. - Vessel's garbage plan states plastic ash for the incinerator may be dumped overboard. Plan must reflect regulation as treating plastic ash as a form of plastic that must be kept on board and discharged at a port facility. Master states crew collects plastic and discharges to shore at all times. MARPOL 73 (2006) AX-V, Reg 3(1)(a)
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 January 2009
Resolved 20 January 2009
Resolution: On 17 May 2009 MSD Lewes checked the plan and confirmed the deficiency has been corrected, deficiency is cleared.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 6 January 2009 Resolved
0410 - Food And Catering - The physical means of escape in the refrigerated chambers does not work properly. The aft freezer door requires a crow bar to open. ILO-147 PWSA 33 USC1223(b)
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 February 2009
Resolved 5 February 2009
Resolution: On 17 May 2009 MSD Lewes checked the freezer door and it''s working properly, deficiency is cleared.
Navigation › Piloting/Steering › Gyro Compass
Issued 2 January 2009 Resolved
E-NOA states that the vessel has a malfunctioning gyro. LOD generated for inbound transit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2009
Resolution: Received tech report attesting to repair of gyrocompass during inspection.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 July 2007 Resolved
Oil samples were found in the cable trunk space on the Captains Deck.
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 20 July 2007
Resolution: C/E removed all material from cable trunk to the satisfaction of the attending USCG Marine Inspectors.
Engineering › Bilge Water Management System › Piping
Issued 16 July 2007 Resolved
Numerous soft patches on piping in E/r. (1) just below OWS (1) overtop of LO storage tank, Also there are several rubber hoses in place of fixed piping throughout E/R. Make permanent repairs to the satisfaction of Class Society
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2007
Resolved 10 October 2007
Resolution: Recieved Class Report attesting to repairs to the above defs.
Fire Fighting › Fire Hoses › Condition
Issued 16 July 2007 Resolved
while testing emergency fire pump found fire hose holed and leaking water. C/O replaced hose and was found sat
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 20 July 2007
Resolution: Replaced hose as neccessary to satisfaction attending Marine Inspector
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 May 2006 Resolved
The vessel was attended on 12April at Port Canaveral and the DECCA BRIDGEMASTER MK2 (3cm) Radar was tested to find erratic transmission. A new magnatron was installed but the fault persisted. The problem is a faulty 25KW modulator (T65610801) but the modulator is on backorder.
Condition: Unknown
Due 27 May 2006
Resolved 24 August 2006
Resolution: Survey conducted by LR surveyor. Report and certificates attested to all navigation equipment operating in compliance with the SOLAS convention.
Documentation › Logs/Records › Oil Record Book
Issued 2 January 2003 Resolved
Oil record book not being filled out according to MARPOL
Due 2 January 2003
Resolved 2 January 2003
Resolution: Briefed the master and chief engineer. Corrected on board
Documentation
Issued 10 June 1996 Resolved
Vsl dose not have record of the required pressure test for the bunker piping system. Vsl to test and record prior to bunkering in the U.S.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Navigation
Issued 29 May 1994 Resolved
The vessel did not have the publication tidal current tables on board as_x001C_required by 33 CFR 164.33(a)(3)(ii).
Condition: Unknown
Due 16 December 1994
Resolved 19 December 1994
Documentation
Issued 29 May 1994 Resolved
The vessel's Oil Transfer Procedures are incomplete: 1. missing the number of persones required to be on duty during oil transfer operations, 2. duties by title of each officer or person in charge, 3. no procedures for reporting oil discharges into the water.
Condition: Unknown
Due 16 December 1994
Resolved 19 December 1994
Deck/Cargo
Issued 29 May 1994 Resolved
Vessels of 1600 GT or more must have a containment capicity of at least one barrel, the vessel's containment did not meet this requirement 33 CFR 155.320 (a)(2). _x001C_
Condition: Unknown
Due 16 December 1994
Resolved 19 December 1994
Navigation
Issued 10 November 1987 Resolved
CHARTS 12326 (FEB 86), 12327 (MAR 86) AND 12334 (FEB 86) NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Navigation
Issued 10 November 1987 Resolved
U.S.C. G. LIGHT LIST, 87 EDITION NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Navigation
Issued 10 November 1987 Resolved
NO TIDAL CURRENT TABLE ON BOARD.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Navigation
Issued 10 November 1987 Resolved
CHART 12333 NOT ON BOARD.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Documentation
Issued 27 February 1985 Resolved
THE VESSEL DID NOT HAVE A RECORD OF THE DATE AND RESULTS OF THE TESTS REQUIRED BY 33CFR156.170
Condition: Unknown
Due 27 February 1985
Resolved 27 February 1985

Ownership record