Records from 2001 to 2026. Most recent: inspection, 24 February 2026.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 June 2025
Resolved
Vessel's watertight door in the collision bulkhead failed the chalk test. Replace gasket as appropriate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2025
Resolution: Recieved evidence of proper operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2025
Resolved
Vessel's Alcohol Swabs were expired. Replace prior to operating more than 2 hours from a location where alcohol testing can be completed.
Action required: 705 - Other - as specified
Resolved 17 June 2025
Resolution: Recieved evidence of alcohol swabs present.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2025
Resolved
Vessel's electrical installation shall be installed to minimize accidental personnel contact with energized parts. Identified loose wire in lazarette, remove or secure as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2025
Resolved 17 June 2025
Resolution: Recieved verification that loose wire was removed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 June 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Marine Inspector found an oil leak coating the lagging on the port engine turbo. Recommended to make necessary repairs and replace lagging.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2024
Resolution: replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2024
Resolved
ndividual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Marine Inspector found indicator light at operating station for forward bilge pump unresponsive when crew activated pump locally in the bilge space. Make necessary repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2024
Resolved 10 July 2024
Resolution: Witnessed operation of forward bilge pump indicator light at operation station. Determined to be SAT
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2024
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Marine Inspector found batteries to be insufficiently secured from shifting. Recommened secure batteries from shifting.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2024
Resolved 10 July 2024
Resolution: Batteries determined to be secured for sea. SAT
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 June 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables. Marine Inspector found that the vessel did not have required publications on board. Recommended to acquire and have readily available the necessary publications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2024
Resolved 15 July 2024
Resolution: Submitted photographic evidence of charts and pubs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 January 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel failed to receive drydock inspection within inspection window. Vessel is prohibited from operating with carriage of passengers until drydock inspection is complete.
46 CFR 176.600(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2024
Resolution: conducted drydock inspection
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 July 2023
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10, For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section. Vessel did not conduct annual firefighting servicing. Conduct firefighting servicing prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2023
Resolved 28 July 2023
Resolution: Fire servicing completed and documentation received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 July 2023
Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter. Retro-reflective tape on all life jackets were worn. Repair reflective tape on life jackets prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2023
Resolved 3 August 2023
Resolution: Recieved objective evidence of replaced retro tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 July 2023
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter. 04 life jackets did not have lights. Add lights to life jackets with missing lights. Passenger count reduced to 28 until new lights are installed.
Action required: 705 - Other - as specified
Due 11 August 2023
Resolved 14 August 2023
Resolution: Recieved objective evidence of new chem lights for life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 July 2023
Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Vessel did not have correct size lifering. Replace current 20” lifering with an USCG approved 24” lifering.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2023
Resolved 1 August 2023
Resolution: Life buoy is of appropriate size and markings.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 28 July 2023
Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Fwd bilge pump light at the operating station is inop. Repair light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 10 August 2023
Resolution: Objective evidence was received of repaired wiring for the forward bilge pump light.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 July 2023
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 31 July 2023
Resolution: Received technician report of radiotelephony certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 28 July 2023
Resolved
The float-free link required by § 180.130(a)(1) must be: Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Float free link was unable to be verified. Replace float free link and provide new approved link with tag.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 3 August 2023
Resolution: Recieved objective evidence of float free links with appropriate tags.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2023
Resolved
At each inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Dead end wires were exposed near the bilge on the forward bulkhead in the engine room. Remove dead end wires or enclose in a junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 10 August 2023
Resolution: Recieved objective evidence of wiring secured in junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 July 2023
Resolved
A submersible electric bilge pump may be used as a power bilge pump in accordance with table 46 CFR 182.520(a), whereas the pump is listed by an independent laboratory as meeting the requirements in UL 1113. Bilges pumps on board were not meeting UL 1113 requirements. Provide documentation from the manufacture verifying UL compliance or install pumps meeting that requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 10 August 2023
Resolution: Recieved objective evidence of installed approved bilge pumps.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 July 2023
Resolved
On a vessel where the upper decks on the vessel are limited the maximum number of passengers allowed on the upper deck must be indicated in durable marking of at least 1” numbers and letters at the entranceway to that deck. Vessel did not have signage stating 04 passengers on the 02 deck. Install signage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 1 August 2023
Resolution: Received a picture of signage installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 July 2022
Resolved
The installation and location of portable fire extinguishers must be to the satisfaction of the Officer in Charge, Marine Inspection. The extinguisher on the bridge is missing the authorized mounting bracket. Install the approved bracket or remove the additional fire extinguisher.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 16 August 2022
Resolution: Fire extinguisher was removed from the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 July 2022
Resolved
Equipment installed on each vessel must be suitable for the purpose intended. The vessels ring life buoys is worn beyond it service life. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 12 September 2022
Resolution: Documentary evidence provided that a approved life ring buoy was purchased and installed.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 26 July 2022
Resolved
A vessel must comply with the applicable requirements for any radio installation certificates to be issued by the FCC as set forth in 47 CFR 80. Vessel is missing communications act safety radiotelephony certificate. Provide valid certificate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 16 August 2022
Resolution: Radiotelephony certificate was located, updated cert in MISLE.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 July 2022
Resolved
Vessel shall carry adequate and up-to-date charts. Vessels charts were expired. Provide current charts or ensure electronic charts are of the latest version, accessible and downloaded, so as to not require the Internet access to view.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 16 August 2022
Resolution: New charts were placed on the vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 July 2022
Resolved
The marine employer must have sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. A non National Highway Traffic Safety Administration (NHTSA) device was being used on the vessel. Provide evidence of approved testing device.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 9 August 2022
Resolution: Received documentary evidence of new non-expired alcohol test swabs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 July 2022
Resolved
An EAP training program must be conducted for the employers crew members and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. No member of the crew has the supervisory training. Provide proof of training.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 10 August 2022
Resolution: Received certificate of completion for the EAP supervisor training.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 4 May 2021
Resolved
A visual and audible alarm must be provided at the operating station for the bilge high level alarms. The vessels bilge high level indicator alarm was inoperable in the v-berth area. Make indicator alarm operable. When operating away from their berth, a member of the vessels crew will make hourly rounds of the v-berth bilge to ensure no ingress of water into that location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2021
Resolved 29 June 2021
Resolution: Attended vessel and tested all bilge alarms, all auditable and visual alarms operable.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 4 May 2021
Resolved
Vessel must be fitted with a suitable magnetic compass designed for marine use and must be illuminated. Vessels magnetic compass was not illuminated. Show proper operation of the compass. Vessel is restricted to daylight only operations until the illumination is operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2021
Resolved 29 June 2021
Resolution: Light in the compass was replaced, operationally sat.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 4 May 2021
Resolved
At each inspection all observed unsafe practices must be corrected and be in satisfactory condition. The vessel has a leak in the bridge allowing water to drip on the electronics. Locate the cause of the leak and provide repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 29 June 2021
Resolution: Leak on the overhead of the bridge was repaired.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 May 2021
Resolved
The discharge end of fuel tank vent pipe must be fitted with a flame screen or flame arrester. Wire must be corrosions resistant wire of at least 30x30 mesh. Both port and starboard flame screens were deteriorated. Repair or replace flame screens.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 29 June 2021
Resolution: New flame screen were installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 May 2021
Resolved
As appropriate for the intended voyage vessels must carry adequate and up-to-date charts, U.S. Coast Pilot [name withheld], Tides and Currents tables. Up-to-date Charts, Tides and Currents table and Light List were not on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 29 June 2021
Resolution: Owner provided chart of the area.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 November 2020
Resolved
ALCOHOL TESTING STRIPS ARE EXPIRED. THE MARINE EMPLOYER MUST HAVE A SUFFICIENT NUMBER OF ALCOHOL TESTING DEVICES ONBOARD. PROVIDE EVIDENCE OF ALCOHOL TESTING STRIPS.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2020
Resolved 5 May 2021
Resolution: Vessel had new Alcohol strips onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 November 2020
Resolved
ALL THREE LIFE FLOAT WATERLIGHT BATTERIES ARE EXPIRED. APPROVED FLOATING WATERLIGHTS ARE REQUIRED TO BE ATTACHED TO THE LIFE FLOAT. PROVIDE EVIDENCE OF NON EXPIRED BATTERIES.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2020
Resolved 5 May 2021
Resolution: All three life float water lights batteries were replaced with new, dates checked.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 November 2020
Resolved
BILGE ALARM IS INOPERABLE. A VISUAL AND AUDIBLE ALARM MUST BE PROVIDED AT THE OPERATING STATION. PROVIDE EVIDENCE OF OPERABLE BILGE ALARM.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2021
Resolution: Vessels 03 bilge alarms are operable visually and audibly.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 November 2020
Resolved
VESSEL HAS SIGNIFICANT OIL LEAKS ON BOTH MAIN ENGINES. MACHINERY AND EQUIPMENT MUST BE MAINTAINED TO AFFORD ADEQUATE PROTECTION FROM CAUSING FIRE, EXPLOSION, MACHINERY FAILURE AND UNJURY. PROVIDE PROOF OF LEAK REPAIR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2021
Resolution: Vessels engines were worked on by the vessel owner’s mechanic and leaks reduced by replacement of gaskets and tightening of bolts. Test ran the engine, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 12 November 2020
Resolved
FOUND VESSEL'S PORT SHAFT TO BE LEAKING WATER, REASON TO BE DETERMINED BY VESSEL OWNER. THERE SHALL BE A MEANS TO PREVENT WATER FROM ENTERING THE VESSEL. PROVIDE PROOF OF LEAK REPAIR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2021
Resolution: Additional shaft packing was needed in order to allow for slight weeping but not enough packing was previously present to prevent leaking. Vessel's mechanic added additional packing material which reduced the leak to an acceptable weep.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 October 2020
Resolved
A Certificated vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The Vessel WET DREAM has lapsed on its annual dates. Vessel shall not operate according to its COI until satisfactory annual inspection is completed.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2021
Resolution: Conducted COI exam on 05MAY21, issued temp COI at that time.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 July 2020
Resolved
Vessel made an unauthorized repair/alteration without notifying local OCMI to the bilge line thru hull valve by making a new thru-hull cut out. Submit repair proposal on plans to bring the vessels hull/thru hull valve area back to original construction strength.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2020
Resolution: Satisfactory inspection/operation of thru hull valve and hull
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2020
Resolved
Fix and or repair exhaust and turbo lagging and all engine oil leaks prior to carriage of passengers
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2020
Resolution: All satisfactory, cleaned entire engine and engine room
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 May 2020
Resolved
Make all thru hull valves operable and available for inspection (sewage and both sea water engine intakes)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2020
Resolved 22 June 2020
Resolution: Conducted satisfactory test of remaining thru hull valves at def check
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2020
Resolved
Repair all worklist items sent via seperate correspondence
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2020
Resolved 25 September 2020
Resolution: All satisfactory
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 May 2019
Resolved
Lifering color faded, replace or repair IAW manufacturer specifications.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2019
Resolution: Corrected color of lifering.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2019
Resolved
Laggin on starboard turbo loose. Fasten lagging as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2019
Resolution: Re-fastened lagging on turbo.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2019
Resolved
Remove or cap deadend wire in engine room overhead.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2019
Resolution: Removed deadend wire in engine room.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 May 2019
Resolved
Alcohol test strips expired. Provide new alcohol test strips.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2019
Resolution: Provided new test strips.
Stability › Intact Stability (when using lifting gear) › General
Issued 12 May 2017
Resolved
During an annual exam it was noticed that the vessel had a canopy installed on main deck. A review of stability test performed in 2012 showed there was no canopy in the calculations done. The canopy needs to be removed until the issue is resolved.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 10 August 2017
Resolution: Owner has decided to wait on doing a new simplified stability test for new canopy found on vessel during the 2017 annual exam.
Lifesaving › Lifefloat › Lifeline
Issued 10 May 2017
Resolved
Life float lines and straps are showing ware. Still functional but time to replace, IAW 46CFR 185.700
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 6 June 2017
Resolution: Life floats issues corrected.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 May 2017
Resolved
Life float water lights work but expired. Replace IAW 46CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 5 June 2017
Resolution: Water lights had all new batteries.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 10 May 2017
Resolved
Life ring water light works but battery is expired. Replace IAW 46CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 6 June 2017
Resolution: Water light replaced.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 10 May 2017
Resolved
Replace all personal marker lights on lifejackets. They expired March 2017, IAW 46CFR 180.75
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 6 June 2017
Resolution: Personal markers all replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 May 2017
Resolved
Replace port and starboard navigation lights. Lights were dim, IAW 46CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 6 June 2017
Resolution: Nav replaced and working.
Stability › Watertight Integrity › General
Issued 10 May 2017
Resolved
Clean and repair seal on forward emergency hatch, IAW 46CFR 177.15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 6 June 2017
Resolution: Hatch seal replaced and sealed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 May 2017
Resolved
Vessel call sign on safety cert needs to match the station license, IAW 46CFR 184.502
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 6 June 2017
Resolution: Call sign matches safety cert with station license.
Navigation › Piloting/Steering › Marine Charts
Issued 10 May 2017
Resolved
Replace tide table, light list, coast pilot, and area charts with current versions IAW 46CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 6 June 2017
Resolution: New updated pubs onboard.
Stability › Watertight Integrity › Deadlight Cover
Issued 10 May 2017
Resolved
Repair port light in female head, frame is broken but still works, IAW 46CFR 171.117
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 6 June 2017
Resolution: Port light was repaired.
Communications › Alarms/Indicators › High Water Alarm
Issued 10 May 2017
Resolved
Repair forward compartment high water visual and audible light, light is dim and alarm is low, IAW 46CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 6 June 2017
Resolution: High water alarm works.
Engineering › Fuel Oil Service System › Filter
Issued 10 May 2017
Resolved
Starboard engine Raycor filter needs drain plug on valve, IAW 46CFR 182.453
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 6 June 2017
Resolution: Plug was installed for both filters.
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2017
Resolved
Engine room electrical outlet needs cover, IAW 46CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 6 June 2017
Resolution: Proper cover on outlet box.
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2017
Resolved
Repair or replace household cables installed on camera system, IAW 46CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 6 June 2017
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2017
Resolved
Remove any dead ended cables under console on the bridge, IAW 46CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 6 June 2017
Resolution: Cables removed.
Engineering › Steering Gear System › Bracket/Clamp
Issued 10 May 2017
Resolved
Replace missing hardware on the steering system ram in the lazerette.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2017
Resolved 10 May 2017
Resolution: Crewmember tightened loose bolt and replaced missing bolts to include locking washers.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 10 May 2017
Resolved
Repair all oil leaks on all turbo chargers on both main diesel engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2017
Resolved 10 May 2017
Resolution: Vessel mechanic removed leaking oil return on all 4 turbos, applied sealant to the threads and tightened lines, operational test were conducted, all satisfactory.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 June 2016
Resolved
Vessel operated with paying passengers onboard past its COI deadline date of 27MAY16, without having its annual inspection done on or prior to that timeframce. The 2016 annual inspection was not scheduled or done until after the inspection window.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 28 June 2016
Resolution: Vessel conducted its 2016 annual inspection on 01JUN16. LOW was issued and accepted.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 1 June 2016
Resolved
All 04 portable extinguishers need annual inspection prior to passengers on board.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2016
Resolved 1 June 2016
Resolution: Received correspondence from Owner/Operator, that showed all fire extinguishers were inspected from Hiller Systems in Pensacola, FL. A visual will be conducted at a later date.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 1 June 2016
Resolved
Both life float lights need new battery. Batteries expired and replace line with a shorter line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 21 June 2016
Resolution: Replaced batteries in life float lights
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 June 2016
Resolved
Med kit missing required gear, needs to be a complete kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 21 June 2016
Resolution: Replaced gear in med kit.
Navigation › Piloting/Steering › Marine Charts
Issued 1 June 2016
Resolved
Vessel required to carry updated charts and pubs. Provide updated chart, nav rules, coast
pilot, and light list.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 21 June 2016
Resolution: Provided updated charts and publications.
Documentation › Certificates/Documents › Letter of Substantial Compliance (DAPI)
Issued 1 June 2016
Resolved
DAPI, drug consortium roster page with all crew and expiration dates, also supervisor training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 21 June 2016
Resolution: Provided roster with all crew, expiration date, and supervisor training
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 1 June 2016
Resolved
Label are where PFDs are stowed w;/ proper #'s.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 21 June 2016
Resolution: PFD stowage was properly labeled
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 1 June 2016
Resolved
Post EAP hotline in common area.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 21 June 2016
Resolution: EAP hotline number was posted in common area.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 June 2016
Resolved
Post emergency instructions at operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 21 June 2016
Resolution: Emergency instructions posted at operating station
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 1 June 2016
Resolved
Salt water supply line needs double clamp.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 1 June 2016
Resolution: Clamp was added to the raw water hose.
Communications › Alarms/Indicators › High Water Alarm
Issued 1 June 2016
Resolved
Label high water alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 1 June 2016
Resolution: Label was added.