TOTAL PACKAGE is a 1984 passenger vessel (inspected). The Coast Guard has recorded 84 inspections since 1985, most recently in March 2026, along with 90 deficiencies and 1 casualty investigation in 2012.

Records from 1985 to 2026. Most recent: inspection, 23 March 2026.

Built
1984
Last inspected
23 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC3496
233046
Flag
UNITED STATES
367008960
Maury page id
psix-233046

Inspections, by type

…with no type recorded7
Years with a record 39 calendar years (1985–2026)
The 84 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)43.6 ft × 14.6 ft × 7.8 ft
Registered tonnagegross 34 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGRANT BOAT WORKS INC · BAYVILLE, NJ, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPENSACOLA BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 31 October 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Simplified, Net Ton
34 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC3496MMSI 367008960 · active · compulsorily equipped · granted 16 October 2024, expires 7 January 2035
WCS2485MMSI not assigned · expired · compulsorily equipped · granted 7 June 1995, cancelled 13 August 2005 · licensed under a name not among this hull’s recorded names (not shown)
WST8483MMSI not assigned · expired · compulsorily equipped · granted 28 February 1994, cancelled 18 July 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 84

23 March 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8330299
14 March 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8093832
10 January 2025 Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8060988
25 March 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7884629
21 November 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7831351
27 February 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7629108
7 February 2023 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7633508
18 January 2023 Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7625820
22 September 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7565091
31 March 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7430531
27 October 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7344994
15 April 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7175767
11 January 2021 Internal Structural Exam · Damage Survey · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7122523
16 October 2020 Type not recorded
No type recorded · Station Pensacola · USCG Heartland District (CGD-H) · Activity 7079762
27 February 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6916806
7 October 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814765
2 April 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6654304
3 January 2019 Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6605335
26 September 2018 Type not recorded
No type recorded · USCGC GANNET (WPB 87334) · USCG Southeast District (CGD-SE) · Activity 6550790
2 February 2018 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6349831
3 April 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6117038
26 January 2017 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6077882
21 June 2016 Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 5916689
5 May 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5869752
12 April 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5852469
14 May 2014 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4860045
30 May 2012 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4296933
16 February 2011 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3941230
5 March 2009 Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3428277
19 February 2009 Hull Examination · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3420323
21 May 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3212567
13 May 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3199395
9 May 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2925370
21 February 2007 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2874925
30 August 2006 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2764175
24 August 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2758641
15 May 2006 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2649491
13 September 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2491739
21 March 2005 Internal Structural Exam · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2315792
27 September 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2206432
9 October 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1924441
16 April 2003 Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1773941
8 October 2002 Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1695501
11 July 2001 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415667
26 March 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1423537
18 May 2000 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 818106
17 May 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1404974
10 April 2000 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 817223
27 July 1999 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1372698
7 April 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788266
9 March 1999 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1416842
22 January 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 787307
8 January 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 809700
28 July 1998 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1368815
5 August 1997 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 780948
27 March 1997 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1103199
22 July 1996 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1086364
15 August 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 877666
26 July 1995 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1187768
2 May 1995 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 862445
3 June 1994 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 860594
27 July 1993 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1160233
9 June 1993 Re-Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1432691
29 May 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 10864
24 September 1992 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 940048
1 June 1992 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1253072
6 August 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 934724
21 June 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1215250
4 June 1991 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1206398
20 September 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1233608
5 June 1990 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 931349
15 August 1989 Plan Review "T" Boat
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1039554
16 June 1989 Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1204290
10 April 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 897121
16 June 1988 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 894099
23 September 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1007680
23 June 1987 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1028568
1 April 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1311354
7 January 1987 Drydock Extension
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1004520
31 July 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306874
1 July 1986 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296150
6 September 1985 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 994554
19 July 1985 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1287076
15 July 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1286681

Deficiency record · 90

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 February 2023 Resolved
Two life jacket were found to be in an unserviceable condition.
Action required: 705 - Other - as specified
Due 1 March 2023
Resolved 2 March 2023
Resolution: Provided evidence of two new life jackets with lights and proper markings.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 7 October 2019 Resolved
Electrical Outlet in FWD accommodation space was found to be reverse polarity.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 8 October 2019
Resolution: Rewired outlet.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 October 2019 Resolved
Water Light on Life Float was deemed inoperable; corroded terminals and water inside bulb.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 7 October 2019
Resolution: Captain Replaced with new Water Light, observed an ALL SAT test and properly installed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 March 2018 Resolved
Reflective tape is faded; renew reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2018
Resolved 12 March 2018
Resolution: Received photo of new tape applied to life ring.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 27 April 2016 Resolved
Licensed personnel did not have documentation showing proof of initial 60 minute training for EAP program. Provide letter/documentation of training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2016
Resolved 5 May 2016
Resolution: Documentation was provided via e-mail to atest for training being completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 May 2012 Resolved
No metal hangers for electrical wiring throughout vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 13 August 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 May 2012 Resolved
Re-wire freshwater pump in engine room with pressure fittings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 13 August 2012
Accommodation/Occupational Safety › Potable Water System › General
Issued 30 May 2012 Resolved
Remove unused general purpose freshwater pump and all associated wiring in the engine space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 13 August 2012
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 May 2008 Resolved
Clean connections for all batteries.
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 21 May 2008
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 May 2008 Resolved
Secure wire to outlet box used for the generator start in engine room.
Due 13 June 2008
Resolved 21 May 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 May 2007 Resolved
Provide covers for the junction boxes for the bilge pump and high level alarm wiring in both mid-body compartments aft of the engine room and in the lazarette in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 10 May 2007
Resolution: Provided covers for the junction boxes for the bilge pump and high level alarm wiring in both mid-body compartments aft of the engine room and in the lazarette.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 9 May 2007 Resolved
Provide a current hydrostatic release unit for the EPIRB in accordance with 46 CFR 180.64. Until that time the vessel is limited to no more than 3 miles from shore.
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 10 May 2007
Resolution: Provided a current hydrostatic release unit for the EPIRB.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 9 May 2007 Resolved
Provide a current lifesaving equipment maintenance record and bridge log in accordance with 46 CFR 185.702 and 46 CFR 185.720.
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 10 May 2007
Resolution: Provided a current lifesaving equipment maintenance record and bridge log.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 21 February 2007 Resolved
Replace the port and starboard aft strut cutlass bearings in accordance with 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 12 March 2007
Resolved 6 March 2007
Resolution: Replaced the port and starboard aft strut cutlass bearing in accordance with 46 CFR 176.610.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 21 February 2007 Resolved
Replace the valve on the through hull fitting for the sewage overboard discharge in accordance with 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 12 March 2007
Resolved 6 March 2007
Resolution: Replaced the valve on the through hull fitting for the sewage overboard discharge in accordance with 46 CFR 176.610.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2006 Resolved
Provide guards for rotating machinery as required by 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 22 August 2006
Resolution: Provided guards for rotating machinery as required by 46 CFR 177.960.
Engineering › Bilge Water Management System › Valve
Issued 15 May 2006 Resolved
Provide a positive means for closing discharge lines on all individual bilge pumps at the hull as required by 46 CFR 182.520
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 22 August 2006
Resolution: Provided a positive means for closing discharge lines on all individual bilge pumps at the hull as required by 46 CFR 182.520.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 May 2006 Resolved
Properly support all electrical wiring as required by 46 CFR 183.340
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 22 August 2006
Resolution: Properly supported all electrical wiring as required by 46 CFR 183.340.
Documentation › Certificates/Documents
Issued 9 October 2003 Resolved
Provide copy of valid certificate of documnetation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 9 October 2003
Documentation › Certificates/Documents
Issued 9 October 2003 Resolved
Provide copy of valid EPIRB regrstration LEGACY COMPONENT DESC: EPIRB Registration
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 9 October 2003
Stability › Watertight Integrity
Issued 9 October 2003 Resolved
Make E/R Aft bulkhead watertight. LEGACY COMPONENT DESC: E/R Aft bulkhead
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 31 October 2003
Lifesaving › Lifejacket/PFD (General)
Issued 9 October 2003 Resolved
Provide Lifejacket donning placard for all types of jackets carried O/B. LEGACY COMPONENT DESC: Donning Placard
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 31 October 2003
Lifesaving › Lifebuoys
Issued 9 October 2003 Resolved
Provide one 24 inch ring buoy w/grab lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 31 October 2003
Lifesaving › Lifebuoys
Issued 9 October 2003 Resolved
Provided buoyant 60 ft lifeline. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 9 October 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 9 October 2003 Resolved
Install machinery guard on stbd eng. LEGACY COMPONENT DESC: Machinery Guard
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 31 October 2003
Construction/Loadline › Structures
Issued 9 October 2003 Resolved
V/W handrail IVO stern area stbd side. LEGACY COMPONENT DESC: Handrails
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 31 October 2003
Construction/Loadline › Structures
Issued 16 April 2003 Resolved
Complete work to address water seepage in area of bow pulpit to 3# stanchion port side per proposal and 835 requirement. LEGACY COMPONENT DESC: Deck Plating
Due 20 June 2003
Resolved 8 October 2003
Construction/Loadline
Issued 11 July 2001 Resolved
Prove proper operation of port side, compt #4 water tight hatch and providecaptive device for hatch
Condition: Unknown
Due 25 July 2001
Resolved 15 August 2001
Construction/Loadline
Issued 11 July 2001 Resolved
Make cable penetration trough collision bulkhead watertight
Condition: Unknown
Due 25 July 2001
Resolved 15 August 2001
Lifesaving
Issued 11 July 2001 Resolved
Provide lights for all lifejackets on board
Condition: Unknown
Due 25 July 2001
Resolved 15 August 2001
Lifesaving
Issued 11 July 2001 Resolved
Replace first aide kit with approved type
Condition: Unknown
Due 25 July 2001
Resolved 15 August 2001
Electrical
Issued 11 July 2001 Resolved
Provide and install cover for shore connection cable
Condition: Unknown
Due 25 July 2001
Resolved 15 August 2001
Fire Fighting
Issued 11 July 2001 Resolved
Provide adequate length of firehose to reach all spaces on vessel
Condition: Unknown
Due 25 July 2001
Resolved 15 August 2001
Construction/Loadline
Issued 11 July 2001 Resolved
Remove old sink hose at engine room, port side fwd, make penetration watertight
Condition: Unknown
Due 25 July 2001
Resolved 15 August 2001
Construction/Loadline
Issued 11 July 2001 Resolved
Install positive shut off valves at overboard discharges for all electric bilge pumps throughout vessel
Condition: Unknown
Due 25 July 2001
Resolved 15 August 2001
Engineering
Issued 26 March 2001 Resolved
REPLACE EMERGENCY FUEL SHUT-OFF VALVES ABOVE FUEL TANKS. TO BE COMPLETED PRIOR TO OPERATION.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Navigation
Issued 26 March 2001 Resolved
REPLACE HYDRAULIC HOSES FOR STEERING IN LAZ. CLEAN AND INSPECT STEERING RAM CONNECTOR, BOLTS, WASHER, AND NUTS TO ENSURE INTERGRITY.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Lifesaving
Issued 17 May 2000 Resolved
Prior to operating with passengers replace expired hydro-static release on life raft.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Construction/Loadline
Issued 27 July 1999 Resolved
Renew non-metalic sections of bilige system with metalic piping.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Lifesaving
Issued 27 July 1999 Resolved
Renew retroreflective tape on life ring buoys with type II.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Lifesaving
Issued 27 July 1999 Resolved
Service liferaft, original bouyant apparatus for 11 persons with one life ring buoy accepted pending servicing.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Documentation
Issued 27 July 1999 Resolved
Provide copy of 1999 contract with consortium for Drug and Alcohol testing.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Construction/Loadline
Issued 9 March 1999 Resolved
SISTER OR REPLACE TRANSVERSE BEAM IWO HATCH OPENING. (2'X 6'X 3') LOCATED IN THE AFT STRB VOID.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Fire Fighting
Issued 22 January 1999 Resolved
Install a Fixed Fire Fighting System in machinery spaces in accordance withU.S. Coast Guard approved plans.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Fire Fighting
Issued 22 January 1999 Resolved
Vessel is not to be operated with passengers for hire after March 11, 1999,until the above requirements have been cleared to the satisfaction of an attending U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Fire Fighting
Issued 22 January 1999 Resolved
Submit plans for review and approval for the installation of a Fixed Fire Fighting System in the machinery spaces in accordance with 46 CFR 181.115(b) and 46 CFR 181.400
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Documentation
Issued 28 July 1998 Resolved
Provide a waste management plan and disposal log IAW MARPOL Annex V.
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Fire Fighting
Issued 28 July 1998 Resolved
Install fixed fire fighting in engine compartment IAW 46CFR 181.400 & 410.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Electrical
Issued 28 July 1998 Resolved
Remove deadended wiring from operating station.
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Lifesaving
Issued 28 July 1998 Resolved
Reconnect HAMMER hydrostatic release IAW manufacturer's instructions._x001C_ (Weak link not connected)
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Engineering
Issued 5 August 1997 Resolved
REMOVE EXISTING PVC PIPE FROM SALTWATER PUMP AND INSTALL A METAL PIPE/ELBOW.
Condition: Unknown
Due 19 August 1997
Resolved 25 August 1997
Engineering
Issued 5 August 1997 Resolved
INSTALL A SUPPORT FOR THE STBD SHIFT CABLE. CURRENTLY CABLE IS NOT SUPPORTED AND IS SHOWING SIGNS OF WEAR.
Condition: Unknown
Due 19 August 1997
Resolved 25 August 1997
Navigation
Issued 5 August 1997 Resolved
REPLACE ALL HYDRAULIC STEERING SYSTEM HOSES DUE TO DETERIORATION. VESSEL ISNOT TO SAIL UNTIL HOSES HAVE BEEN REPLACED.
Condition: Unknown
Due 19 August 1997
Resolved 25 August 1997
Construction/Loadline
Issued 5 August 1997 Resolved
MOUNT ALL BILGE PUMPS IN THEIR EXISTING LOCATIONS. CURRENTLY PUMPS ARE NOT PERMANENTLY MOUNTED.
Condition: Unknown
Due 19 August 1997
Resolved 25 August 1997
Engineering
Issued 5 August 1997 Resolved
CLAMP THE OVERBOARD DISCHARGE HOSE ON THE STBD SIDE TO THE INSTALLED THROUGH HULL FITTING. EXISTING HOSE IS NOT CLAMPED.
Condition: Unknown
Due 19 August 1997
Resolved 25 August 1997
Engineering
Issued 5 August 1997 Resolved
REMOVE EXISTING PVC PIPE TURBO INTAKE PIPE WITH A METAL PIPE.
Condition: Unknown
Due 19 August 1997
Resolved 25 August 1997
Lifesaving
Issued 22 July 1996 Resolved
PLACE DISTRESS SIGNALS IN BRIGHTLY COLORED CONTAINER MARKED "DISTRESS SIGNALS"
Condition: Unknown
Due 3 August 1996
Resolved 1 August 1996
Lifesaving
Issued 22 July 1996 Resolved
POST EMERGENCY BROADCAST PLACARD
Condition: Unknown
Due 3 August 1996
Resolved 1 August 1996
Lifesaving
Issued 22 July 1996 Resolved
PROVIDE DOCUMENTATION OF DRILLS
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 22 July 1996 Resolved
PROVIDE DOCUMENTATION OF CREW TRAINING
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 22 July 1996 Resolved
REPAIR OR REPLACE ONE LIFERING, INSTALL TYPE II RETROREFLECTIVE TAPE ON BOTH.
Condition: Unknown
Due 3 August 1996
Resolved 1 August 1996
Unknown
Issued 26 July 1995 Resolved
PROVIDE EVIDENCE OF CHEMICAL TESTING PROGRAM HAS BEEN IMPLEMENTED.
Condition: Unknown
Due 26 July 1995
Resolved 26 July 1995
Navigation
Issued 2 May 1995 Resolved
PRIOR TO OPERATING THE VESSEL MORE THAN 1000' FEET FROM SHORE WITH MORE THAN 6 PASSENGERS FOR HIRE ON BOARD PROVIDE VALID FCC SAFETY CERTIFICATE TOCOGNIZANT OCMI. (47 CFR 80.933 (a))
Condition: Unknown
Due 2 May 1995
Resolved 2 May 1995
Navigation
Issued 3 June 1994 Resolved
PROVIDE A CURRENT DEVIATION TABLE FOR THE MAGNETIC COMPASS.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Fire Fighting
Issued 3 June 1994 Resolved
PRIOR TO CARRYING PASSENGERS, SERVICE THE B-II FIRE EXTINGUISHER IN THE FORWARD COMPARTMENT (6 YEAR SERVICE REQUIRED).
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Navigation
Issued 3 June 1994 Resolved
PROVIDE CURRENT NAVIGATION CHARTS.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Lifesaving
Issued 9 June 1993 Resolved
VESSEL RESTRICTED TO TWENTY-TWO (22) TOTAL PERSONS UNTIL ONE (01) USCG APPROVED TYPE I LIFE PRESERVER IS PROVIDED.
Condition: Unknown
Due 22 July 1993
Resolved 22 July 1993
Navigation
Issued 9 June 1993 Resolved
PROVIDE THE FOLLOWING NAVIGATION PUBLICATIONS CURRENT TO WITHIN THREE YEARS: LIGHT LIST VOL I & II, COAST PILOT VOL 2 & 3.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Navigation
Issued 1 June 1992 Resolved
PROVIDE UPDATED NAVIGATION RULES OF THE ROAD INTERNATIONAL/INLAND.
Condition: Unknown
Due 24 September 1992
Resolved 24 September 1992
Lifesaving
Issued 1 June 1992 Resolved
TOTAL PERSONS RESTRICTED TO 13 ADULT UNTIL 10 TYPE I USCG APPROVED ADULT LIFE PRESERVERS PROVIDED.
Condition: Unknown
Due 24 September 1992
Resolved 24 September 1992
Lifesaving
Issued 1 June 1992 Resolved
REPLACE EXISTING GRAB LINES ON BUOYANT APPARATUS WITH 2 - 6' LINES AT EACH ATTACHMENT RING.
Condition: Unknown
Due 24 September 1992
Resolved 24 September 1992
Navigation
Issued 4 June 1991 Resolved
PROVIDE THE MOST RECENT EDITION OF CHART #12300.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Engineering
Issued 4 June 1991 Resolved
PROVIDE A OPERATIONAL TEST OF THE HAND OPERATED BILGE PUMP,PRESENTLY IN-_x001C_ OPERABLE.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Lifesaving
Issued 4 June 1991 Resolved
PROVIDE(12)HAND HELD DISTRESS SIGNALS (6)RED AND(6)ORANGE PRESENT FLARES_x001C_ ARE OUTDATED.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Navigation
Issued 4 June 1991 Resolved
PROVIDE THE MOST RECENT EDITION OF THE LIGHT LIST FOR THE ROUTE VESSEL_x001C_ TRANSITS.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Navigation
Issued 4 June 1991 Resolved
PROVIDE THE MOST RECENT EDITION OF THE COAST PILOT VOLUME 3.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Accommodation/Occupational Safety
Issued 10 April 1989 Resolved
REPLACE TWO (2) 1 1/2 INCH GATE VALVES WHERE ELECTROLOSIS HAS TAKEN HEAVY WEAR ON VALVES PRIOR TO REFLOATING VESSEL.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Engineering
Issued 10 April 1989 Resolved
REMOVE ALL OIL AND GREASE FROM PORT AND STARBOARD ENGINE WELLS.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Engineering
Issued 10 April 1989 Resolved
REPLACE STARBOARD TAILSHAFT FUBBER CUTLESS BEARING WHERE WORN MORE THAN FIFTY PERCENT.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Fire Fighting
Issued 16 June 1988 Resolved
PROVIDE ONBOARD THE SUBJECT VESSEL AN ADDITIONAL B-II MARINE TYPE FIRE EXTINGUISHER.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Navigation
Issued 23 June 1987 Resolved
PROVIDE AN UP TO DATE COAST PILOT #3.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Lifesaving
Issued 23 June 1987 Resolved
PROVIDE TWO COAST GUARD APPROVED RING BUOYS.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Electrical
Issued 23 June 1987 Resolved
ENCLOSE THE SWITCH BOX FOR THE ACCOMMODATION SPACE LIGHT FIXTURE.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Fire Fighting
Issued 23 June 1987 Resolved
PROVIDE ONE ADDITIONAL B-II PORTABLE FIRE EXTINGUISHER FOR THE BELOW DECKS ACCOMMODATION SPACE.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Construction/Loadline
Issued 1 July 1986 Resolved
SECURE VESSEL'S WEATHERDECK HATCHES WITH CHAIN OR LINE.
Condition: Unknown
Due 1 July 1986
Resolved 1 July 1986
Lifesaving
Issued 1 July 1986 Resolved
PROVIDE ON BOARD ONE CHILD'S LIFE PRESERVER. UNTIL THIS REQUIREMENT IS MET, ONLY TWO CHILDREN MAY BE CARRIED.
Condition: Unknown
Due 1 July 1986
Resolved 1 July 1986
Engineering
Issued 19 July 1985 Resolved
ADJUST IDLE SPEED ON PORT ENGINE TO AVOID STALLING OF ENGINE PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 19 July 1985
Resolved 19 July 1985
Accommodation/Occupational Safety
Issued 19 July 1985 Resolved
PROVIDE 36" RAIL AT AFT END OF PILOT HOUSE IN LIEU OF TEMPORARY LIFE LINE PRIOR TO 20AUG85.
Condition: Unknown
Due 19 July 1985
Resolved 19 July 1985
Accommodation/Occupational Safety
Issued 19 July 1985 Resolved
INSTALL THE WEATHERTIGHT DOORS TO THE CABIN PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 19 July 1985
Resolved 19 July 1985
Engineering
Issued 19 July 1985 Resolved
PROVE PROPER OPERATION OF ENGINE INSTRUMENTATION IN THE PILOT HOUSE PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 19 July 1985
Resolved 19 July 1985

Casualty record · 1

26 September 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4452373
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.