MAURY USCG vessel records Sign in
← All vessels

SUPERIOR EXCELLENCE

SUPERIOR EXCELLENCE is a 1984 offshore supply vessel. The Coast Guard has recorded 49 inspections since 1989, most recently in June 2017, along with 27 deficiencies and 1 casualty investigation in 2006.

Records from 1989 to 2017. Most recent: inspection, 15 June 2017.

Built
1984
Last inspected
15 June 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8757104 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC9419
233055
Flag
NIGERIA
367051440, 367101960 (licence lapsed)
Maury page id
psix-233055

Inspections, by type

…with no type recorded3
Years with a record 22 calendar years (1989–2017)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it186 - Convention (Subpart B), Net Ton
185 - Regulatory (Subpart C or D), Net Ton
620 - Convention (Subpart B), Gross Ton
272 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC9419MMSI 367101960 · expired · compulsorily equipped · granted 25 March 2006, cancelled 28 May 2016
WCW7248MMSI 367051440 · expired · compulsorily equipped · granted 9 July 1996, cancelled 9 September 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 49

15 June 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6176551
21 December 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3914125
14 October 2010 Administrative Inspection · Examination of Repairs · Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3893064
29 October 2008 MTSA Verification · Deficiency Check · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3356263
30 July 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3284054
24 April 2008 Inclining Experiment
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3191454
3 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3157330
11 February 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3145362
8 February 2008 Deadweight Survey · Inclining Experiment
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3146367
23 July 2007 Construction Oversight · Ballast Water Examination · Examination of Repairs · Internal Structural Exam · Plan Review (Other than "T") · MTSA Verification · COI Inspection · Inclining Experiment · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3004585
26 June 2006 Inclining Experiment · COI Inspection · MTSA Verification · Ballast Water Examination · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2704900
9 June 2006 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2674680
5 June 2006 Deficiency Check · Inclining Experiment
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2671177
25 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2658827
17 May 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2678213
14 July 2005 Re-Inspection · MTSA Verification · Ballast Water Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2426185
15 July 2004 Examination of Repairs · Hull Examination · MTSA Verification · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2133652
17 September 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1910816
6 May 2002 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1613288
15 June 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366432
2 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768562
1 March 2001 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420467
28 February 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 195598
28 August 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821632
1 June 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369702
1 July 1999 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457662
12 June 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396950
24 April 1997 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428774
14 June 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411317
9 June 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 875911
23 May 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414457
8 June 1994 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449697
21 September 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440740
28 August 1992 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423719
4 October 1991 COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938645
17 July 1991 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252018
27 March 1991 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219699
13 March 1991 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920837
12 March 1991 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931309
31 January 1991 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929935
4 December 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217248
17 November 1990 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933009
11 October 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226525
27 July 1990 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 900074
7 May 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912125
3 April 1990 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925381
23 March 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237910
28 November 1989 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 916457
18 October 1989 Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 913729

Deficiency record · 27

Engineering › Lubricating Oil Service System › Expansion Joint
Issued 29 October 2008 Resolved
Replace flex hose on return line of crane hyd. system with and approved expansion joint at next annual inspection
Due 31 October 2009
Resolved 19 November 2009
Communications › Alarms/Indicators › General Alarm
Issued 29 October 2008 Resolved
Provide service report for general alarm on emergency power
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2008
Resolved 31 October 2008
Resolution: Vessel provided service report, vessels emergency back up battery was replaced.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 29 October 2008 Resolved
Reset automation alarm setting to to middle set point vs. highest set point allowed to facilitate proper testing of system. Once reset conduct automation test and provide report prior to departure.
Due 31 October 2008
Resolved 31 October 2008
Resolution: Vessel submitted new automation report indicating proper operation of all alarms
Construction/Loadline › Hull › Keel
Issued 23 July 2007 Resolved
Vessel required to cut and insert new plate in way of #8 Starboard ballast tank on the slope of the keel. Cut out was called while in drydock by shipyard, but missed when all previous repairs were completed.
Action required: 705 - Other - as specified
Due 4 October 2009
Resolved 19 November 2009
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 26 June 2006 Resolved
Update and submit to local OCMI for review.
Action required: 705 - Other - as specified
Due 14 August 2006
Resolved 21 July 2006
Stability › Incline Test › General
Issued 16 June 2006 Resolved
Provide stability review approved by the Marine Safety Center.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2006
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 5 June 2006 Resolved
Provide an operations manual approved by the Marine Safety Center.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2006
Resolution: Duplicated entry
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 June 2006 Resolved
Make the vessel available for inspection and obtain a valid Certificate of Inspection. The expiration on the Temporary COI issued by Morgan City is 14JUL06.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 14 July 2005 Resolved
Provide operations manual for approval, to include stability KG curve, calc's and preloading instructions.
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 31 July 2008
Engineering › Lubricating Oil Service System › Manifold
Issued 14 July 2005 Resolved
Demonstrate compliance for jacking hydraulic system with 46 CFR 58.30 as required by NVIC 8-91, through approved plans or other means.
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 14 July 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 14 July 2005 Resolved
Provide engine RPM gages at loacl control station in E/R.
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 13 July 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 14 July 2005 Resolved
Provide stability review for vessel without helo deck installed. Vessel was built with helo deck, deck removed at some point during vsl life, stability reveiw was never completed for current configuration.
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 13 July 2006
Engineering › Shafting/Propeller Arrangements › Thrust Shaft
Issued 15 July 2004 Resolved
Provide shaft tachs as required by NVIC 1-78.
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 14 July 2005
Resolution: Provided engine RPM with corresponding shaft speed charts as equivilent.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 15 July 2004 Resolved
Provide fire detection system in port/stbd engine rooms as required by NVIC 1-78.
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 14 July 2005
Resolution: Provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 15 July 2004 Resolved
Provide local engine room propulsion control as required by NVIC 1-78.
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 14 July 2005
Resolution: Provided.
Deck/Cargo
Issued 1 March 2001 Resolved
Upon installation of legs and pads, conduct NDT and submit to attending Coast Guard Marine Inspector.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Deck/Cargo
Issued 1 March 2001 Resolved
Conduct NDT of pedestal for new crane installed on starboard forward main deck and submit to attending Coast Guard marine inspector.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Construction/Loadline
Issued 1 March 2001 Resolved
Complete weld out of transom butt seam at bottom plate joint and air test in presence of Coast Guard marine inspector.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Engineering
Issued 1 June 2000 Resolved
PROVIDE AUTOMATION EQUIPMENT TEST PROCEDURES FOR APPROVAL.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Engineering
Issued 1 June 2000 Resolved
PROVIDE EVIDENCE OF TEST OF AUTOMATION EQUIPMENT IN ACCORDANCE WITH APPROVED TEST PROCEDURES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Construction/Loadline
Issued 1 June 2000 Resolved
PROVIDE INSTALLED MEANS OF CLOSING PORT & STBD ENGINE ROOM MAINDECK VENTS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Lifesaving
Issued 1 July 1999 Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District's policy "Rescue Boat Requirements for Offshore Supply Vessels" dated 12NOV98 to thesatisfaction of the attending Marine Inspector.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Electrical
Issued 13 March 1991 Resolved
MAKE PERMANENT REPAIRS TO STBD GENERATOR.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Fire Fighting
Issued 11 October 1990 Resolved
PROVIDE ONBOARD A SUFFICENT NUMBER OF FIRE STATIONS IAW 46CFR 95.10-10(d)_x001C_ SO THAT FIRE HOSES OF CORRECT LENGTH MAY BE PROVIDED IAW 46CFR 95.10-90._x001C_ MODIFICATIONS TO BE COMPLETED PRIOR TO NEXT COI DATE.
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Lifesaving
Issued 18 October 1989 Resolved
INSTALL A SUITABLE MEANS OF ESCAPE.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Documentation
Issued 18 October 1989 Resolved
PROVIDE PLANS TO INCLUDE INBOARD/OUTBOARD PROFILE, GENERAL ARRANGEMENT, FIRE CONTROL AND LIFESAVING, LEG AND LEG SUPPORT, HYDRAULIC SYSTEM PLAN FORJACKING SYSTEM INCLUDING THE FAIL SAFE SYSTEM.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Documentation
Issued 18 October 1989 Resolved
RESUBMIT OPERATING MANUAL FOR APPROVAL.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989

Casualty record · 1

17 May 2006Routine · role: Involved in a Marine Casualty · activity 2678213
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.