Records from 1985 to 2026. Most recent: inspection, 22 April 2026.
Inspection history · 76
22 April 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8353318
17 July 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8172899
22 May 2024
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7915689
9 May 2024
Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7906036
16 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7896901
10 October 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7799150
16 May 2023
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7663221
11 October 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7572241
6 July 2022
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7498696
4 October 2021
Plan Review "T" Boat · Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7329165
11 January 2021
Deficiency Check · Construction Oversight · Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7153447
5 August 2020
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7019803
11 May 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6951593
5 May 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6948559
15 August 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6783937
14 August 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6512058
7 May 2018
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6408227
16 August 2017
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6241660
21 March 2017
Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6109071
12 August 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5969307
18 April 2016
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5856512
25 August 2014
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4965919
28 June 2012
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4359639
15 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4208867
20 July 2011
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4088335
16 July 2009
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3536270
25 June 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3247625
19 May 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3210891
11 July 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2991414
9 May 2006
Re-Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2644404
1 November 2005
Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2526157
20 May 2005
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2363018
26 July 2004
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2146205
4 June 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2088760
17 June 2003
Re-Inspection · MARPOL Annex I Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1819047
13 June 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1629850
13 May 2002
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1616189
24 May 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1406939
13 April 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1061747
31 May 2000
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1384460
8 May 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1379066
10 June 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 808286
8 June 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1128308
17 April 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 789340
5 September 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 786442
11 June 1997
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1110823
30 April 1997
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1097751
31 December 1996
Examination of Repairs · Plan Review "T" Boat
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1096672
12 December 1996
Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1092033
26 November 1996
Examination of Repairs
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1182170
26 November 1996
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1184432
20 August 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 166541
20 August 1996
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1409545
22 July 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1089560
17 June 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1193458
9 May 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1083332
22 June 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1191689
28 June 1994
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 864152
26 May 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1169713
15 July 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 35214
15 July 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1157660
2 July 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 846527
11 July 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 163745
24 June 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 956483
1 April 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 961624
18 June 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 888960
21 June 1990
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1222027
11 May 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 919985
19 June 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1043910
28 December 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1043233
27 June 1988
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1196731
19 June 1987
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1004697
18 May 1987
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1024611
20 June 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 996546
21 November 1985
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 995548
19 June 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1285661
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 July 2025
Resolved
Require 6/6 red/orange handheld flares or 12 all red.
46 CFR 180.68(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 30 July 2025
Resolution: Operator provided photograph showing all required distress signals on board.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 July 2025
Resolved
Replace/add items in first aid kit.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 30 July 2025
Resolution: Operator provided photograph showing first aid kit equipment on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 July 2025
Resolved
Add donning placard for each type of PFD's.
46 CFR 185.516
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 30 July 2025
Resolution: Operator provided photograph showing donning placards are installed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 July 2025
Resolved
Replace 07 adult PFD's. Pax # reduced.
46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 31 July 2025
Resolution: MI observed all required lifejackets on board the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 July 2025
Resolved
Label PFD amount correctly.
46 CFR 185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 31 July 2025
Resolution: MI observed all lifejackets stowed appropriately.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2025
Resolved
Replace rubber trash can w/ a non-combustible type.
46 CFR 177.405(f)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 30 July 2025
Resolution: Operator provided photograph showing non-combustable trash can installed on the vessel.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 July 2025
Resolved
VHF radio must have lat/long + MMSI number.
47 CFR 80.905 (a)(1)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 25 August 2025
Resolution: Operator providede photograph showing lat and long appearing on the DSC radio.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 17 July 2025
Resolved
Conduct monthly EPIRB checks.
46 CFR 185.728(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 31 July 2025
Resolution: MI observed operator had recorded EPIRB test in vessel's log.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 17 July 2025
Resolved
Conduct abandon ships drills quarterly or recommended monthly.
46 CFR 185.520(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025
Resolved 31 July 2025
Resolution: MI observed operator had logged abandon ship drill in vessel's log.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 May 2024
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. The fuel tank compartment (which is protected by a fix fire fighting system) to mid-ship void space allows the atmosphere between the two spaces to be share through an opening. A seal/fire stop must be installed.
46 CFR 177.405(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 28 May 2024
Resolution: Received photo of seal/fire stop installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 22 May 2024
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Was not on board during COI Renewal inspection, but verified that owner has valid COD (expires 31MAR2025) through MISLE.
46 CFR 67.3143(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 6 June 2024
Resolution: Received Photo showing completion of def.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 22 May 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instruction was not posted during COI Renewal inspection, must post.
46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 6 June 2024
Resolution: Received Photo showing completion of def.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 May 2024
Resolved
Each link certified by the manufacturer to meet the requirements of this subpart must have a corrosion resistant, waterproof tag attached to it that has the following information on it. Newly installed IBA's was missing its float-free linkage tag, must provide tag.
46 CFR 160.073-20
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 1 July 2024
Resolution: Received objective evidence show the completion of the LF linkage deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2024
Resolved
A flammable vapor detection system required by § 182.410(c) must meet UL 1110 or be approved by an independent laboratory. Owner/Operator to provide proof vessel's flammable vapor detection system meets UL requirement.
46 CFR 182.480(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 18 August 2026
Resolution: Vessel had an approved vapor detection system installed and works satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2024
Resolved
Procedures for checking the proper operation of a flammable vapor detection system must be posted at the primary operating station. The system must be self-monitoring and include a ground fault indication alarm.
Procedures not posted at primary operation station, must be post.
46 CFR 182.480(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 6 June 2024
Resolution: Received Photo showing completion of def.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2024
Resolved
An operation and maintenance manual for the flammable vapor detection system must be kept onboard. Manual was not on board during inspection.
46 CFR 182.480(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 28 May 2024
Resolution: Received manual of vapor detector system.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 May 2024
Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented. Owner/Operator not documenting survival craft maintenance.
46 CFR 185.702
Action required: 10 - Deficiency Rectified
Due 22 May 2024
Resolved 22 May 2024
Resolution: Rectified on spot
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 May 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Maintenance was being conducted but not documented in a log. This corresponds with Monthly maintenance under NFPA 10.
46CFR176.810(b)(2)(iv)
Action required: 10 - Deficiency Rectified
Due 22 May 2024
Resolved 22 May 2024
Resolution: Rectified on spot
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 9 May 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 August 2024
Resolution: Received text from Rep with new medical card, photo NOT saved in MISLE. [name withheld] A/N: 7915689.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2024
Resolved
A space containing machinery powered by, or fuel tanks for, gasoline must have a ventilation system that complies with this section and consists of a mechanical exhaust system consisting of at least two ventilation exhaust ducts located at the end of the space opposite from where the supply ducts are fitted, which extend to the lowest part of the bilge of the space on each side of the space, and which are led to one or more powered exhaust blowers. Exhaust blowers were not functioning. Correct prior to commercial operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2024
Resolution: Exhaust blower working as intended due COI inspection. On 28th of May, received photo of the ducting properly installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 October 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel's due date for drydock examination expired 31AUG2023.
46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 17 April 2024
Resolution: Vessel underwent credit drydock and internal structural examination.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 10 October 2023
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Vessel's 04 life floats were beyond serviceable life expectancy and in need of replacement.
46 CFR 185.700(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 8 May 2024
Resolution: Vessel replaced four 12 person life floats with two 12 person life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 October 2023
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Vessel had 02 life float lights that were inoperable. O/O is to provide a functioning life float light for each of the vessel's life floats.
46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 8 May 2024
Resolution: 02 waterlights were observed to be functioning and with correct unexpired batteries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow shall be fitted at the tank connection and at the engine. The shutoff valve at the tank shall be operable from outside the tank compartment. Vessel's Emergency fuel shut off valve was inoperable from the pull station at helm location. O/O is to provide a properly functioning fuel shut off valve at the tank supply.
46 CFR 182.15-40(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 8 May 2024
Resolution: Witnessed satisfactory test of fuel shutoff valve from operating station.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 10 October 2023
Resolved
The master of a vessel, except a vessel listed in § 185.502(a) of this part, shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Passenger counts logs were unable to be provided to marine inspector during inspection.
46 CFR 185.504
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 8 May 2024
Resolution: Vessel has not operated with passengers since this deficiency was issued. Since, owner has purchaced a logbook for passenger count that will be left at ticket booth.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 October 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and publications for navigation of large enough scale to make safe navigation possible. Vessel was using an electronic chart-plotter which was unable to be properly corrected due to age. Back up means were unable to provided to marine inspector at time of inspection.
46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 22 May 2024
Resolution: Verified all electronic chart-plotter were present and operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 October 2023
Resolved
Gauges to indicate cooling water temperature and lube oil pressure shall be provided for all propulsion engines and be located in the view of the operator. Both engines were not displaying lube oil pressure at the time of inspection.
46 CFR 182.15-5(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 22 May 2024
Resolution: Verified oil pressure alarm present on system.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 October 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel's first-aid kit's contents were expired.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 8 May 2024
Resolution: New analgesic medication was purchased and provided for the kit.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 October 2023
Resolved
All portable fire extinguishers shall be located so as to be convenient to the the space protected. Fire extinguisher mounted towards machinery area was not readily available and was the incorrect size. 1 40 B.C fire extinguisher shall be installed near machinery space/area.
46 CFR 181.30-10(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 28 May 2024
Resolution: Received photo of fire extinguisher being properly installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 October 2023
Resolved
A deck hatch cover must have securing devices. Vessel's main deck hatch to the void space was missing 01 dog securing bolt and had 01 dog securing bolt which was bent, preventing proper operation of the hatch. All installed hardware for the hatch shall be installed and in good working order.
46 CFR 179.360(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 8 May 2024
Resolution: Hardware was replaced and the hatch cover was operable at the time of this inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 October 2023
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline. 01 high water alarm in tank void was inoperable at time of inspection. All installed high water alarms shall be in a properly operating state at all times.
46 CFR 182.530(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 22 May 2024
Resolution: Verified that all bilge alarms were operational.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 October 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Overhead electrical light at helm station was missing its' protective cover exposing incandescent bulbs and connections causing a possible safety hazrd to operator/vessel.
46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 22 May 2024
Resolution: Wire and housing in question were removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 October 2023
Resolved
Vessels shall be equipped with a suitable number of portable battery lights. Vessel did not have any portable battery lights designated for the vessel.
46 CFR 184.30-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 22 May 2024
Resolution: Verified presents of 02 portable lights
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 October 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel was missing 01 fire bucket with lanyard and 01 fire bucket on board was missing its' lanyard.
46 CFR 181.610
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 22 May 2024
Resolution: Verified all 3 fire buckets were present.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 10 October 2023
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF–DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2), except that a VHF radiotelephone installation without DSC capability is permitted until one year after the Coast Guard notifies the Commission that shore-based sea area A1 coverage is established. Vessels in this category must not operate more than 20 nautical miles from land. Vessel's VHF radio did not have a registered MMSI number associated with it.
47 CFR 80.905(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 22 May 2024
Resolution: Verified MMSI: 367419670 was present VHF radio and Cert.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 October 2022
Resolved
A vessel of more than 26 feet but not more than 65 feet must carry a minimum of one life buoy of not less that 24 inches in diameter with a lifeline of at least 60 feet in length with a light. Vessel's life buoy has a 20 inch diameter and the light was inoperable. Vessel to provide an approved life buoy, line and prove proper stowage of life buoys and operation of light prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Verified approved lifebuoy onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 October 2022
Resolved
Each survival craft on a vessel must be in good working order and ready for immediate use. All lights on the 4 lifefloats are inoperable. Prove proper operation of lights prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Verified all lights were operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 October 2022
Resolved
Each life jacket must be marked with Type I retro material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retro-reflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Retro material on multiple lifejackets were wasted. Replace retro material as needed on affected lifejackets prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Retro material replaced as needed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 October 2022
Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals approved in accordance with § 160.021 or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and six hand orange smoke distress signals approved in accordance with § 160.037 in Subchapter Q of this chapter, or other standard specified by the Commandant. Vessel's flares were expired. Ensure valid and approved flares on board prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Verified approved/non-expired flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 October 2022
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.520(a): 1 fixed power pump and 1 portable handle pump capable of pumping 5 GPM and provided with hoses for pumping bilges on the suction and discharge ends. Vessel did not have a portable hand bilge pump. Ensure portable pump with suitable hose is on board and prove proper operation prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Verified adequate portable pumping arrangements.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 October 2022
Resolved
Stations in the maritime service must be licensed by the FCC either indicually or by fleet. The vessel’s FCC Station License was expired. Provide valid station license prior to the carriage of passengers.
47 CFR 80.13
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Verified valid station license.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 October 2022
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation once every 5 years and the FCC technician will issue a Communications Act Safety Radiotelphony Certificate. The vessel’s certificate was set to expire prior to next operating season. Vessel to get radio communications inspected and issuance of certificate prior to the carriage of passengers.
47 CFR 80.903
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Verified valid Radiotelephony Certificate.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 October 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel’s first aid kit was expired. Vessel to provide valid first aid kit prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Verified valid first aid kit.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 October 2022
Resolved
Abandon ship, man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel could not provide record of MOB drills. Vessel to conduct satisfactory MOB drill in presence of Marine Inspector and log in records prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Verified adequate MOB drill and log.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 11 October 2022
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel could not provide record of fire drills. Vessel to conduct satisfactory fire drill in presence of
Marine Inspector and log in records prior to carriage of
passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Verified adequate fire drill and log.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 October 2022
Resolved
An enclosed space containing machinery powered by gasoline or other fuels having a flash point of 43.3 °C
(110°F) or lower must be equipped with a flammable vapor
detection device in compliance with 46CFR182.480. An
operation and maintenance manual for the flammable vapor
detection must be kept onboard. Vessel could not provide
manual to determine adequate way to test system. Provide
manual(s) onboard prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Verified manual onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 October 2022
Resolved
A vessel not required to have a power driven fire pump by 46CFR181.300 must have at least three 9.5 liter (2.5 gallon buckets with an attached lanyard satisfactory to the OCMI, placed so as to be easily available during an emergency. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. Vessel did not have any fire buckets onboard. Vessel to provide three fire buckets meeting the regulations prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 16 May 2023
Resolution: Verified adequate fire bukets onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2021
Resolved
A life jacket must be provided for each person on board. The vessel is short three adult life jackets. Vessel shall provide the additional three life jackets prior to carrying the maximum adult capacity.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2021
Resolved 27 May 2022
Resolution: Verified new life jackets are now onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 4 October 2021
Resolved
Each life float shall be equipped with a waterlight. Three of the waterlights are inoperable. Ensure operable waterlights are installed prior to operating at night.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2021
Resolved 27 May 2022
Resolution: Verified waterlights are operable.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 4 October 2021
Resolved
Pre-engineered fixed fire extinguishing systems shall only be used in spaces less than 2,000 cubic feet. The bulkhead between the main bilge compartment and the lazarette has several penetrations. Seal the penetrations to ensure the extinguishing agent in the main bilge compartment does not escape the space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2021
Resolved 27 May 2022
Resolution: Penetrations have been sealed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 October 2021
Resolved
Electrical equipment and installation must be suitable for the roll, pitch, and vibration of the vessel underway. An inverter was installed in the main bilge space w extension chords running to the O/S. Provide a line diagram of the inverter in a permanent position then installed IAW approved plan.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2021
Resolved 27 May 2022
Resolution: Electrical plan was approved and installation verified.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 August 2020
Resolved
Stations in the maritime service must be licensed by
the FCC; one license will be granted for operation of
all maritime services transmitting equipment on
board a vessel. The station license on board is
expired.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 20 August 2020
Resolution: Observed valid station license onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 August 2020
Resolved
Battery terminals shall be of the soldered type and all
connections shall be made to the battery terminals
with permanent type connectors. Wing nut
connectors were found on all three batteries.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 20 August 2020
Resolution: Observed new permanent connectors on batteries.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 5 August 2020
Resolved
A hatch cover must be attached to the hatch frame or
coaming by hinges, captive chains or other devices
of substantial strength to prevent its loss. The hatch
to the midship compartment is not attached.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 20 August 2020
Resolution: Observed hatch cover properly attached.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 August 2020
Resolved
A flammable vapor detection system must provide a
visual and audible alarm at the operating station. The
vapor detection alarm goes off intermittently, without
the presence of vapor.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 20 August 2020
Resolution: Observed properly operating flammable vapor detector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 August 2020
Resolved
A vessel must carry one floating waterlight approved
in accordance with 46CFR161.010 attached with a
lanyard around the body of the lifering. The waterlight
attached to the lifering was not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 20 August 2020
Resolution: Observed operational waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 August 2020
Resolved
The equipment for lifefloats must meet the following
specifications: light must be a floating waterlight
attached around the body of the life float by a lanyard
at least 18ft in length. The vessel only had one
waterlight for all four lifefloats.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 20 August 2020
Resolution: Observed three new waterlights, all life floats now have their own waterlight.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2019
Resolved
Cylinders shall be so mounted as to be readily accessible and capable of easy removal for recharging and inspection, including weighing. CO2 cylinder for fixed fire fighting system is not mounted in appropriate bracket required by the manufacturer. Rectify deficiency within 07 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2019
Resolved 22 August 2019
Resolution: New, appropriate bracket was installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 August 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Charts on board are not updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 26 August 2019
Resolution: New chart book purchased
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 August 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot, Coast Guard light list, tide tables, and current tables. Required publications or Eldridges were missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 26 August 2019
Resolution: New Eldridge book purchased
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 August 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 29 August 2019
Resolution: New valid certificate is on order.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 August 2019
Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 4 feet high. When stowed in tiers, the separate units must be kept apart by spacers. Life floats on board were not separated by spacers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 26 August 2019
Resolution: Wooden spacers installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 August 2019
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. The waterlight lanyard was not secured around the body of the ring life buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 26 August 2019
Resolution: Photo displayed proper installation of waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 August 2018
Resolved
Each survival craft must be secured to the vessel by a painter. Painter was not connected to life floats.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2018
Resolved 14 August 2018
Resolution: Life floats properly secured to vessel with a painter in a float free arrangement.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 August 2018
Resolved
Provisions shall be made to prevent admission of air into space protected by fire fighting. Space between engine room bulkhead and main bilge compartment was not vapor tight. OLD T – 46 CFR 181.20-35
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 5 September 2018
Resolution: Holes in bulkhead sealed with approved sealant.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 August 2018
Resolved
Wiring, joints, and splices shall be made mechanically secure. High level indicator wiring in main bilge compartment is not properly spliced and is laying in bilge compartment. OLD T – 46 CFR 183.05-50(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 5 September 2018
Resolution: Wiring properly connected and secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 August 2018
Resolved
Vessels greater than 26ft, but less than 65 ft are required to have 1 fixed power bilge pump and 1 portable hand pump or 1 fixed hand pump and 1 portable hand pump. Vessel only had 1 fixed power bilge pump, but did not have a hand pump. Pump must be capable of 5 GPM as per OLD T – 46 CFR 182.25-10.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 5 September 2018
Resolution: Portable hand pump provided.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 14 August 2018
Resolved
Each survival craft must be provided with means to prevent shifting. Forward life float is not being prevented from shifting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 5 September 2018
Resolution: Life floats provided with means to prevent shifting.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 August 2018
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked. Child size lifejackets were stowed in a location labeled ‘adult’.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 5 September 2018
Resolution: Child size life jackets properly stowed in a location labeled "Child".
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 August 2018
Resolved
Placards containing instructions for the donning and use of life jackets aboard must be posted. Vessel has 3 types of lifejackets but only 1 donning placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 5 September 2018
Resolution: Appropriate placards for donning life jackets displayed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 August 2018
Resolved
A vessel must carry adequate and up-to-date charts and publications. Vessel is missing tide tables, light list, and currents tables that are most up-to-date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 5 September 2018
Resolution: Up-to-date charts and pubs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 August 2018
Resolved
Each life float must be fitted with 2 paddles. 1 paddle has a broken handle and must be renewed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 5 September 2018
Resolution: New additional paddle provided for life float.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 August 2018
Resolved
When life floats are stowed in tiers, the separate units must be kept apart by spacers. No spacers were present between life floats that were stacked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 5 September 2018
Resolution: Life floats properly stowed and seperated by spacers.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 14 August 2018
Resolved
Each MSD must be free of defects that would allow toxic substances to escape into the interior of the vessel. Duct tape was found on connections forward of MSD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 5 September 2018
Resolution: New connection forward of the MSD installed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 August 2018
Resolved
Each life float must be fitted with a light and must be attached by a 3/8” lanyard resistant to UV and be 18 ft in length. The light was broken and the line was not sufficient.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 5 September 2018
Resolution: New light and appropriate lanyard affixed to life float.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 August 2018
Resolved
The name of the vessel and the capacity of persons must be printed in clearly legible letters and numbers on each life float. Top 2 life floats need re-finishing and re-marking.
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 15 August 2019
Resolution: Life floats are marked properly
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 16 August 2017
Resolved
Vessel is required to have an additional 06 distress signals.
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 25 September 2017
Resolution: Vessel rep provided an additional 06 distress signals.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 August 2017
Resolved
B-1 extinguisher did not receive annual inspection.
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 25 September 2017
Resolution: Vessel rep provided proof of B-1 extinguisher annual inspection.
Stability › Weathertight Integrity › General
Issued 16 August 2017
Resolved
03 hatches were found not adequately weather tight.
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 25 September 2017
Resolution: Vessel rep installed foam gaskets on 03 aft hatches.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 16 August 2017
Resolved
FCC safety certificate was found to be expired. 47 CFR 13. The vessel's operation is limited to not more than 1000' from shore until a valid safety certificate is on board.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 1 November 2017
Resolution: Vessel rep provide valid FCC safety certificate.
Engineering › Fuel Oil Service System › Tank
Issued 12 August 2016
Resolved
Install bonding for fuel fill.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 21 September 2016
Resolution: Bonding for fuel fill installed satisfactorily.
Electrical › Electric Supply System (service) › Cable
Issued 12 August 2016
Resolved
Remove excess electrical cords in center void.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 21 September 2016
Resolution: Electrical cords were removed.
Lifesaving › Lifefloat › Markings
Issued 12 August 2016
Resolved
Stencil vessel name on life float.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 21 September 2016
Resolution: Life float was stenciled with the vessels name.
Lifesaving › Lifefloat › Paddle
Issued 12 August 2016
Resolved
Stencil paddles with vessels name.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 21 September 2016
Resolution: Paddles were stenciled with the vessels name.
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 August 2016
Resolved
Shorten length of cable that is attached to the fuel shut off valves.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 21 September 2016
Resolution: Fuel shut off cable was shortened satisfactorily.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 12 August 2016
Resolved
Add annual inspection date to fire extinguisher in the center void.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 21 September 2016
Resolution: Inspection tag was affixed to the fire extinguisher.
Construction/Loadline › Structures › Deck Plating
Issued 12 August 2016
Resolved
Repair cracked welds in center void at next dry dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 21 March 2017
Documentation › Certificates/Documents › Stability Letter
Issued 15 December 2011
Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THEREFORE LIMITED TO: 42 PERSONS(PASSENGERS AND CREW)
Due 1 June 2012
Resolved 21 May 2012
Resolution: Issued new stability letter based upon weight ratio calcs requested by owner.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 July 2009
Resolved
Provide up to date vessel Documentation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 28 July 2009
Resolution: Vessel owner provided copy of vessels documentation
Communications › Radio Communications › VHF Radiotelephone
Issued 16 July 2009
Resolved
Renew vessel radio station license
Condition: Improper/Lack of Maintenance
Due 31 July 2009
Resolved 28 July 2009
Resolution: Vessel owner provided a copy of vessels radio station license
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 June 2008
Resolved
Renew bouyant line connecting float light to ring buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2008
Resolved 25 June 2008
Resolution: Owner installed new line as required
Documentation › Markings/Placards › Warning Signs
Issued 25 June 2008
Resolved
Label emergency fuel shut offs and bilge alarm panel on conso;e
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2008
Resolved 25 June 2008
Resolution: Owner provided labels as required
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 June 2008
Resolved
Conduct drills as required prior to carrying passengers and document
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2008
Resolved 25 June 2008
Resolution: Owner conducted at the dock drills with attending marine inspector
Engineering › Bilge Water Management System › Not Operational
Issued 11 July 2007
Resolved
Bilge pump not working properly due to loose and coroded wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 11 July 2007
Resolution: Vessel owner renewed wire and satisfactory tested bilge pumping system.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 July 2007
Resolved
Discarded 20 adult PFD's and 2 child size, material worn and easily torn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 11 July 2007
Resolution: Owner procured new pfd''s and placed into service on vessel.
Communications › Alarms/Indicators › Fire Alarm
Issued 20 May 2005
Resolved
Prove proper operation of Vapor Detector.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 10 June 2005
Resolution: Owner called to say sensor was replaced and unit is operating correctly. spot check will be performed at a later date.
Lifesaving › Buoyant Apparatus
Issued 4 June 2004
Resolved
Replace defective buoyant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2004
Resolved 7 June 2004
Resolution: Defective buoyant apparatus replaced with a servicable lifefloat.
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 17 June 2003
Resolved
16 life preservers found to be worn and degraded beyond servicable condition. Vessel limited to 35 adults until satisfactory replacement life preservers obtained and placed on board.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 18 June 2003
Resolution: New life preservers purchased, labelled and placed on board.
Lifesaving › Buoyant Apparatus
Issued 17 June 2003
Resolved
Replace degraded life float painter and lifelines. LEGACY COMPONENT DESC: Painter/Lifelines
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 18 June 2003
Resolution: Replacement painter and lifelines purchased and installed by owner.
Lifesaving
Issued 8 May 2000
Resolved
Renew deteriorated child size life preserver. Renew retro-reflective tape_x001C_where deteriorated on five life preservers.
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Construction/Loadline
Issued 8 May 2000
Resolved
MSD through-hull standpipe wasted and holed. Renew sea valve and wasted pipe or submit an alternate proposal.
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Engineering
Issued 8 June 1998
Resolved
MAKE EMERGENCY FUEL SHUT OFF SYSTEM OPERATIONAL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Fire Fighting
Issued 8 June 1998
Resolved
SERICE AND PROVIDE REPORTS FOR ALL EXTINGUISHERS.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Engineering
Issued 5 September 1997
Resolved
PRIOR TO CARRYING PASSENGERS OR PLACING VESSEL IN SERVICE FOR THE 1998 SEASON, PROVE COMPLIANCE WITH THE VENTILATION REQUIREMENTS CONTAINED IN 46 CFR 182.15-45(d).
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Construction/Loadline
Issued 31 December 1996
Resolved
PERFORM NDT ON HULL INSERT WELD PORT SIDE AND TRIM-TAP HULL WELDS, PRIOR TOTAKING PASSENGERS FOR HIRE.
Condition: Unknown
Due 31 December 1996
Resolved 31 December 1996
Construction/Loadline
Issued 31 December 1996
Resolved
CONDUCT OPS TEST WITH VSL UNDER-WAY TO ASSURE EFFECTS OF TRIM-TAPS ON VESSEL'S PERFORMANCE.
Condition: Unknown
Due 31 December 1996
Resolved 31 December 1996
Accommodation/Occupational Safety
Issued 31 December 1996
Resolved
CONDUCT WEIGHT TEST OF DECK EXTENSION IN WAY OF AFT SEATS TO 150% OF PASSENGER WEIGHT. TEST TO BE WITNESSED BY A MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 31 December 1996
Resolved 31 December 1996
Construction/Loadline
Issued 20 August 1996
Resolved
SUBMIT REPAIR PROPOSAL TO MSO BOSTON AND COMPLETE REPAIRS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR & COGNIZANT [name withheld] PASSENGERS FOR HIRE. REPAIR PROPOSAL TO BE SUBMITTED NO LATER THAN20 SEP 96.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Lifesaving
Issued 17 June 1996
Resolved
PROPERLY MARK RING BUOY AND BUOYANT APPARATUS WITH TYPE I RETRO-REFLECTIVE MATERIAL IN ACCORDANCE WITH 46 CFR 185.604.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Lifesaving
Issued 17 June 1996
Resolved
BUOYANT APPARATUS PENDANTS PROVIDED AT EVERY OTHER BECKET. PROPERLY LOCATEPENDANTS FOR BUOYANT APPARATUE IN ACCORDANCE WITH 46 CFR 160.010-3.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Lifesaving
Issued 22 June 1995
Resolved
RETROFLECTIVE TAPE AND VESSEL'S NAME ARE NOT ON BUOYANT APPARATUS.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Construction/Loadline
Issued 22 June 1995
Resolved
1" HOLE IN MAIN DECK (NOT WATERTIGHT).
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Engineering
Issued 2 July 1993
Resolved
INSTALL FLAME SCREENING OR FLAME ARRESTERS TO THE DISCHARGE END OF THE GASOLINE TANK VENT PIPE IN ACCORDANCE WITH 46 CFR 182.15-35.
Condition: Unknown
Due 6 July 1993
Resolved 6 July 1993
Documentation
Issued 24 June 1992
Resolved
VESSEL DOES NOT HAVE MARPOL ANNEX V PLACARD POSTED. POST PLACARD.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Lifesaving
Issued 24 June 1992
Resolved
BUOYANT APPARATUS PENDANTS SECURED TO LIFELINE. PROPERLY SECURE PENDANTS TO BUOYANT APPARATUS.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Fire Fighting
Issued 24 June 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Fire Fighting
Issued 24 June 1992
Resolved
PROVIDE ANNUAL SERVICING OF FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Lifesaving
Issued 24 June 1992
Resolved
PROPERLY MARK BUOYANT APPARATUS WITH VESSEL NAME AND NUMBER.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Lifesaving
Issued 19 June 1987
Resolved
VESSEL HAD 6 RED AND 6 ORANGE HAND FLARES OUTDATED. TO BE RELACED NO LATER THAN 26JUN87
Condition: Unknown
Due 19 June 1987
Resolved 19 June 1987