Records from 2016 to 2017. Most recent: inspection, 6 November 2017.
Documentation record
Registered dimensions (L × B × D)39.9 ft × 11.4 ft × 5.4 ft
Registered tonnagegross 16 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHOMAS MARINE INDUSTRIES · POMPANO BEACH, FL, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST JOHN, VI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Regulatory (Subpart C or D), Net Ton
16 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Construction/Loadline › Structures › Deck Plating
Issued 19 June 2017
Resolved
Grind and treat wood rot on underside of deck plating above engine turbo.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 5 July 2017
Resolution: Wood replaced with new wood and insulation.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 19 June 2017
Resolved
Replace and properly secure turbo insulation lagging.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 5 July 2017
Resolution: Insulation replaced on turbo.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 March 2016
Resolved
Missing (09) life jackets. Restricted to (11) total people on board.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 11 April 2016
Resolution: Lifejackets replaced.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 18 March 2016
Resolved
Provide and post emergency instructions.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 11 April 2016
Resolution: Emergency Instructions posted.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 March 2016
Resolved
Prove proper operation of water light lanyard clip.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 11 April 2016
Resolution: New lanyard clip installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 March 2016
Resolved
Remove dead-end wiring in engine room.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 11 April 2016
Resolution: Dead-end wires removed.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 18 March 2016
Resolved
Provide proof of 2015 MIS report sumbission.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 11 April 2016
Resolution: MIS report witnessed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 March 2016
Resolved
Provide current alcohol test swabs.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 11 April 2016
Resolution: Current alcohol test swaps witnessed.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 March 2016
Resolved
Provide proper life jacket stowarge placards including quantity.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 11 April 2016
Resolution: Stowage placards posted.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 18 March 2016
Resolved
Provide emergency steering instructions on vessel emergency instructions.
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 11 April 2016
Resolution: Emergency steering added to instructions.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 18 March 2016
Resolved
Properly label engine room vent closures and stowage locations.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 11 April 2016
Resolution: Vent cover stowage properly labeled.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 18 March 2016
Resolved
Prove proper operation of engine room ventilation closures.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 11 April 2016
Resolution: Velcro added to closure devices to make better seal.