Inspection history · 22
23 June 2026
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8412244
2 June 2026
Annual Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8387559
20 December 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8050845
29 May 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7922940
19 January 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7851839
11 December 2023
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7838210
23 May 2023
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7688968
29 March 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7420896
3 February 2022
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7390382
2 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7213857
25 June 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6987806
5 September 2019
Damage Survey · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6807146
31 August 2019
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6802792
22 July 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6758030
25 April 2019
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6678489
15 January 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6611102
8 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6504442
14 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6391829
24 January 2018
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6344370
18 April 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6127428
7 December 2016
DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6053360
26 February 2016
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5823073
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2026
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. MI identified two hydraulic steering hoses on starboard aft side in need of replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 23 June 2026
Resolution: Recieved photographs attesting to new hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2026
Resolved
If your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, twice every 5 years. No more than 3 years may elapse between any check and its immediate predecessor.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 23 June 2026
Resolution: Received photographs attesting to new PRV.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 May 2023
Resolved
Vessels not fitted with a single source emergency lighting system shall have individual storage battery powered automatically operated lights in strategic locations.
Multiple emergency lights found inoperative, with batteries requiring replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 26 May 2023
Resolution: Received email from vessel rep with pictures reporting that the batteries for the lights in question were replaced and now work properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2023
Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold shall be water-jacketed or effectively insulated.
Lagging on the starboard generator, near the base/beginning of the exhaust piping, is deteriorated and requires replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 30 May 2023
Resolution: Vessel rep provided pictures via email of exhaust pipe properly wrapped/lagged.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2023
Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space (other than a paint locker).
Multiple five gallon pales of oil found stored in the
void compartment aft of the machinery compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 26 May 2023
Resolution: Received email from vessel rep with pictures reporting that the number of pales of oil stored in the void compartment has been reduced to <55 gallons total.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 23 May 2023
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: a self-propelled vessel that is certificated to carry more than 150 passengers. AIS must be maintained in effective operating condition, which includes the ability to access AIS information from the primary conning position, the accurate input and upkeep of all AIS data fields and system updates, and the continual operation of AIS and its associated devices at all times while the vessel is underway or at anchor, and if moored, at least 15 minutes prior to getting underway.
The subject vessel is a SPV certificated to carry 351 passengers. At time of inspection, the available objective evidence indicates that the installed AIS is not meeting all above-noted and applicable requirements. Specifically, there are multiple alarm messages on the AIS transceiver display, the AIS transceiver unit is installed in the cabinet under the bridge console, the navigation status (underway, at anchor, moored, etc.) is not being maintained up to date, and a search on NAVCEN’s AIS verification tool does not return any AIS data for the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 30 May 2023
Resolution: AIS head-unit was remounted on top of console for ready access by vessel crew. A dedicated VHF antenna was installed to improve signal strength. Vessel’s AIS signal now visible on MarineTraffic.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2023
Resolved
At each inspection for certification and at every other vessel inspection, all observed fire hazards must be corrected.
Multiple flammable liquids containers found stored in decommissioned ice maker in the storage locker/room on the Hurricane deck.
Action required: 10 - Deficiency Rectified
Due 23 May 2023
Resolved 23 May 2023
Resolution: The flammable liquids containers were removed from the storage locker/room by the completion of the inspection.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2022
Resolved
In addition, they must be so insulated with approved structural insulation, bulkhead panels, or deck coverins so that, if subjected to the standard fire test for the applicable time period listed. Vessel was missing insulation on the overhead above the WTD of the engine room entrance and above the Port Engine.46 CFR 116.415(a)(2)(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2022
Resolved 29 March 2022
Resolution: Received photographic evidence, replaced insulation of missing areas of engine room, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2022
Resolved
Tanks, tank vents and other appurtenances, piping and pipe fittings shall be checked. Vessel had minor fuel leak at union and remote shutoff bonnet underneath the FO day tank in the engine room.46 CFR 176.25-10(a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2022
Resolved 29 March 2022
Resolution: Received photographic evidence, repacked the valve, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Protect passengers, crew, or other persons, and the bessel from electrical hazards. Light diffusers are missing in the port and stbd workshops forward of the engine room.
46 CFR 120.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2022
Resolved 29 March 2022
Resolution: Received photographic evidence, all missing lights received light covers in work shop.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 February 2022
Resolved
When Class I doors are installed below a deck the molded line of which at its lowest point at side is less than 7 feet above the deepest load line, an indicator light for each door which warns when the door is open must be installed on the bridge. Vessel was missing WTD indicator on the bridge.
46 CFR 170.255(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2022
Resolved 11 April 2022
Resolution: Not required, entered in error.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2022
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are proper operating condition and fit for the service for which they are intended. Vessel was missing multiple planks on port/stbd paddlewheel. Submit proposal for repairs and annual repacement/repair of damaged planks. 46 CFR 176.25-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2022
Resolved 29 March 2022
Resolution: Added special note about replacing paddle boards in the summer (may timeframe), all sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2022
Resolved
A 40-B protable fire extinguisher installed outside the space may be substituted for a fixed gas fire extinguishing system in a storeroom containing flammable liquid or a paint locker, with a volume of not more than 200cuft. Remove items outside of paint locker and install either fixed extingishing system or portable 40-B outside approved space.46 CFR 118.400(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2022
Resolved 29 March 2022
Resolution: Paint cabinet cleared out and taken off the vessel, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2022
Resolved
A door must be of a self-closing type capable of closing against a 3.5 list of the vessel and holdback hooks are not allowed. Vessel aft main hall door was not self closing and galley door had holdbacks keeping it from closing all the way.46 CFR 116.435(c)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2022
Resolved 29 March 2022
Resolution: door was adjusted to properly seal, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 June 2021
Resolved
Wiring joints and splices shall be made in junction boxes. Several cables in upper deck storage locker observed on overhead missing required junction box.
46 CFR 120.115(a)
"Old T" 183.05-50(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 14 June 2021
Resolution: Received sat photographic evidence from vessel rep [name withheld] confirming junction box covering previously exposed cables.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 June 2021
Resolved
Lighting fixtures shall be constructed in accordance with the requirements of UL Standard for Marine Type Electric Light Fixtures, Subject 595. Original protective cover for overhead lighting in upper deck storage locker missing. Replace in kind.
46 CFR 120.115(a)
"Old T" 183.10-20(l)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 14 June 2021
Resolution: Received sat photographic evidence from vessel rep [name withheld] confirming overhead lighting replaced and covered properly.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 June 2021
Resolved
At each inspection for certification and at every other vessel inspection all observed fire hazards must be corrected. Multiple open flammable liquid containers observed in upper deck storage locker.
46 CFR 115.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 14 June 2021
Resolution: Received sat photographic evidence from vessel rep [name withheld] confirming flammable liquids placed ashore and storeroom cleaned.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 June 2021
Resolved
All electrical equipment including motors, generators, controllers, distribution panels, shall be dripproof protected. Battery cables in aft portion engine compartment missing cover at time of inspection.
46 CFR 120.115(a)
"Old T" 183.10-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 14 June 2021
Resolution: Received sat photographic evidence from vessel rep [name withheld] confirming cover placed over battery cables in E/R.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 June 2020
Resolved
The master shall conduct sufficient drills to make sure that all crew members are familiar with their duties during emergencies such as man overboard or abandoning ship. Crew was unavailable to demonstrate upon inspection
Action required: 10 - Deficiency Rectified
Due 25 June 2020
Resolved 25 June 2020
Resolution: Conducted Drills while USCG was on site
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 25 June 2020
Resolved
The master shall conduct sufficient fire drills to ensure each member of the crew is aware of tehir duties during an emergency. Crew was unable to demonstrate fire drill during inspection.
Action required: 10 - Deficiency Rectified
Due 25 June 2020
Resolved 25 June 2020
Resolution: Conducted Drills while USCG was on site
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2020
Resolved
All vessels must have sufficient navigation lights in accordance with navigation rules. Starboard side navigation light is dim.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 15 July 2020
Resolution: Nav lights have been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2019
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported a hydraulic failure while attempting to get underway with passengers.
Provide this office with the following prior to getting underway with passengers:
1. Repair plan to hydraulic system identifying the failure and how it will be repaired.
2. Conduct a Sea Trial in the presence of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2019
Resolved 6 September 2019
Resolution: Reviewed Service Tech report and conducted satisfactory Sea Trials, ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2019
Resolved
Vessel owner “self-reported” that the vessel’s port main drive engine would not develop oil pressure. This was discovered during standard start up procedures. The vessel was not underway and had no passengers.
The following requirements must be meet prior to carrying passengers for hire:
1. Provide this office with a Repair Proposal and Service Tech Report attesting to the repairs and proper operation of the vessel’s port main drive engine and associated components. The Service Tech Report should include causative factors.
2. Vessel is required to conduct Sea Trials in the presence of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2019
Resolved 26 July 2019
Resolution: Conducted satisfactory engine test. all sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 August 2018
Resolved
Vsl is broadcasting: Invalid IMO #.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 September 2018
Resolved 1 November 2018
Resolution: Vessel met all requirements for AIS broadcasting.