09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2021
Resolved
Each large battery installation must be located in an enclosed box solely dedicated to the storage of batteries. Vessel had unprotected batteries in the MSD tank space. Vessel to provide batteries with proper box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 10 May 2021
Resolution: Vessel provided battery box.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 26 April 2021
Resolved
Each floating waterlight must be approved in accordance with 46 CFR 161.010. Vessel had an improper light attached to the ring buoy. Vessel to secure an approved waterlight to the ring buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 10 May 2021
Resolution: Vessel provided approved water light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2021
Resolved
Placards containing instructions for the donning and use of the life jacket aboard the vessel must be posted in conspicuous places that are accessible and visible to crew and passengers. Vessel does not have a life jacket placard posted onboard. Vessel to post appropriate life jacket donning placard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 10 May 2021
Resolution: Vessel posted life jacket placard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2021
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. the use of plastic tie wraps must be limited to bundling. Vessel was using plastic tie wraps as supports throughout vessel. Vessel to provide metal brackets to support all cable and wire.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 10 May 2021
Resolution: Vessel provided metel hanger for cable runs.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 April 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 10 May 2021
Resolution: Vessel provided appropriate charts and pubs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 April 2021
Resolved
Portable fire extinguishers shall be installed to the satisfaction of the [name withheld] discovered portable extinguisher bracket on upper deck did not latch. Vessel to provide a bracket that can latch.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 10 May 2021
Resolution: Vessel provided proper fire extinguisher bracket.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 April 2021
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel does not have an FCC Safety Radiotelephony Certificate on board. Vessel to obtain valid certificate.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 10 May 2021
Resolution: Vessel provided Safety Radiotelephony Certificate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 January 2021
Resolved
Demonstrate weathertightness of forepeak hatch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2021
Resolution: Cleared by attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 January 2021
Resolved
Crop and renew wasted rail courses throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2021
Resolution: Cleared by attending MI.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 11 January 2021
Resolved
Reweld diagonal support in fore peak.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2021
Resolution: Cleared by attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 January 2021
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel COI anniversary date is 07 November, and an annual inspection has not been completed. Vessel is allowed to transit within Sector Los Angeles /Long Beach zone, but is prohibited from the carriage of passengers or cargo until a satisfactory annual inspection has been completed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2021
Resolution: MI conducted NTZ COI Inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 January 2020
Resolved
Replace life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2020
Resolved 4 March 2020
Resolution: Vessel replaced ring life buoy,
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 31 January 2020
Resolved
Demonstrate proper operation of port aft accomodations door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2020
Resolved 4 March 2020
Resolution: Vessel repaired door and demonstrated operation.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 January 2020
Resolved
Provide flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2020
Resolved 4 March 2020
Resolution: Vessel provided flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2020
Resolved
Properly install engine room blower ducting to provide air changes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2020
Resolved 4 March 2020
Resolution: Vessel re-connected blower ducting.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 31 January 2020
Resolved
Demosntrate proper operation of engine room bilge high level alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2020
Resolved 4 March 2020
Resolution: Vessel replaced high level float switch and demonstrated operation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 January 2020
Resolved
Remove dead end wires and provide proper connections to wiring in pho-pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2020
Resolved 4 March 2020
Resolution: Vessel removed dead end wiring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2020
Resolved
Mark child lifejacket locations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2020
Resolved 5 March 2020
Resolution: Vessel marked lifejacket locations.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 November 2018
Resolved
Provide the proper amount of fire buckets.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2018
Resolved 13 December 2018
Resolution: Fire buckets provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2018
Resolved
Remove dead end wires under steering console.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2018
Resolved 13 December 2018
Resolution: Dead end wires removed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 November 2018
Resolved
Update FCC station license.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2018
Resolved 13 December 2018
Resolution: FCC Station License renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 November 2018
Resolved
Properly label lifejacket storage.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2018
Resolved 13 December 2018
Resolution: Lifejacket storage properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 November 2018
Resolved
Place life ring buoy onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2018
Resolved 13 December 2018
Resolution: Lifering back on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 November 2018
Resolved
Remove fire hose from E/R vent.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2018
Resolved 13 December 2018
Resolution: Fire hose removed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 February 2018
Resolved
Repair lower rail course aft upper deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2018
Resolved 23 April 2018
Resolution: lower rail repaired.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 21 February 2018
Resolved
Mark storage of child lifejackets with size and count.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 March 2018
Resolved 23 April 2018
Resolution: Storage marked.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 15 February 2017
Resolved
Provide (01) B-II extinguisher in lieu of excess A-II extinguishers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 6 March 2017
Communications › Alarms/Indicators › General Alarm
Issued 15 February 2017
Resolved
Repair stbd engine cooling water temp gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 6 March 2017
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 November 2016
Resolved
Crop and renew deteriorated longitudinal stringer in forward cabin void stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 28 November 2016
Resolution: Stringer renewed.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 1 November 2016
Resolved
Replace missing scupper plug in main cabin.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 28 November 2016
Resolution: Scupper replaced.
Construction/Loadline › Penetrations › Gasket
Issued 1 November 2016
Resolved
Re-seal watertight hatches at completion of drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 28 November 2016
Resolution: Hatches sealed.
Electrical › Electrical Distribution System (service) › Cable
Issued 1 November 2016
Resolved
Remove dead end wire in center cabin void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 28 November 2016
Resolution: Wire removed.
Fire Fighting › Fire Pumps › Arrangement
Issued 1 November 2016
Resolved
Remove "Y-valve" and extra hose from fire pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 28 November 2016
Resolution: Y-valve and extra hose removed.
Accommodation/Occupational Safety › Potable Water System › General
Issued 1 November 2016
Resolved
Make proper repairs to holed water tank in forward cabin void.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 28 November 2016
Resolution: Water tank repaired.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 1 November 2016
Resolved
Clean oil residue in E/R bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 28 November 2016
Resolution: E/R cleaned.