Records from 1985 to 1995. Most recent: inspection, 11 September 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
11 September 1995
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1190253
1 September 1994
Hull Examination · COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1427036
3 February 1993
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1134392
27 July 1992
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 218015
27 July 1992
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 649316
3 July 1992
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 124045
1 July 1992
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 90375
29 June 1992
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 958727
9 June 1992
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1263460
5 March 1992
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1316418
24 June 1991
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1244237
7 June 1991
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1244432
13 May 1991
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1244609
31 December 1990
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1238967
25 October 1990
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 920440
19 July 1990
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 912558
2 July 1990
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1233978
1 August 1989
Plan Review "T" Boat
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1352691
27 June 1989
Deficiency Check · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1034662
7 April 1989
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1043858
10 March 1989
Plan Review "T" Boat
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 896219
28 February 1989
Drydock Extension
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 891809
23 February 1989
Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 896218
3 August 1988
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1041513
2 June 1988
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 889124
14 August 1987
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1336923
2 June 1987
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1316139
20 November 1986
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1329953
18 August 1986
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1001833
30 July 1986
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 997523
2 April 1986
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1304629
1 April 1986
Credit Drydock
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 998412
6 June 1985
Initial Certification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 996928
Navigation
Issued 9 June 1992
Resolved
VESSEL IS RESTRICTED TO 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL SIDEBAND RADIO IS FULLY OPERATIONAL, INCLUDING SEND AND RECEIVE ON 2182._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Unknown
Issued 9 June 1992
Resolved
REMOVE UNUSED TRIM TAB HARDWARE AND WIRING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Navigation
Issued 9 June 1992
Resolved
REMOUNT STARBOARD RUNNING LIGHT FOR PROPER DISPLAY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Lifesaving
Issued 9 June 1992
Resolved
INTALL BUOYANT LINE ON 10 PERSON LIFE FLOAT.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Electrical
Issued 9 June 1992
Resolved
SHOW ALL WIRING TO BE IN ACCORDANCE WITH APPROVED PLANS AND INSTALLED IN ACCORDANCE WITH PROPER MARINE PRACTICE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Fire Fighting
Issued 9 June 1992
Resolved
SHOW EVIDENCE OF SERVICING OF TWO B-II FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Documentation
Issued 9 June 1992
Resolved
POST CERTIFICATE OF INSPECTION UNDER GLASS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Construction/Loadline
Issued 13 May 1991
Resolved
DRILL STRESS-RELIEF HOLES IN SMALL CRACK IN TRANSOM BULWARK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Lifesaving
Issued 13 May 1991
Resolved
CONDUCT ALL REQUIRED DRILLS, INCLUDING MAN-OVERBOARD, FIRE, AND COLLISION._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Electrical
Issued 13 May 1991
Resolved
PROPERLY MOUNT LIGHT FIXTURE E/R STBD SIDE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Engineering
Issued 13 May 1991
Resolved
RENEW LAGGING ON BOTH M/E EXHAUSTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Construction/Loadline
Issued 13 May 1991
Resolved
MAKE PERMANENT REPAIRS TO CRACK IN TRANSOM BULWARK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Construction/Loadline
Issued 13 May 1991
Resolved
INSTALL PLUG IN PASSENGER COMPARTMENT DRAIN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Navigation
Issued 13 May 1991
Resolved
VESSEL IS RESTRICTED TO 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL SSB RADIO IS OPERATIONAL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Navigation
Issued 13 May 1991
Resolved
PROVIDE NAVIGATIONAL CHARTS OF OPERATIONAL AREA IN A USEABLE SCALE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Navigation
Issued 13 May 1991
Resolved
PROVIDE COPY OF RULES OF NAVIGATION RULES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Engineering
Issued 13 May 1991
Resolved
DRILL AND SAFETY WIRE OR DOUBLE-NUT AND INSTALL LOCK WASHERS ON ENGINE AND TRANSMISSION CONTROL CABLE END FITTINGS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 September 1991
Resolved 23 September 1991
Documentation
Issued 13 May 1991
Resolved
PROVIDE MARPOL TRASH & GARBAGE PLACARD.
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Lifesaving
Issued 13 May 1991
Resolved
PROVIDE ADDITIONAL REFLECTIVE TAPE ON LIFE FLOATS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Lifesaving
Issued 13 May 1991
Resolved
REMOVE WIRE TIES FROM LIFE FLOAT LIFELINES AND REPLACE WITH TWINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Lifesaving
Issued 13 May 1991
Resolved
MARK CHILDS PFD STOWAGE ON AFTER SIDE OF BOX._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Fire Fighting
Issued 13 May 1991
Resolved
PROVIDE NOZZLE FOR FIRE HOSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Engineering
Issued 13 May 1991
Resolved
INSTALL ADDITIONAL HOSE CLAMP ON STBD M/E V-DRIVE WATER HOSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Engineering
Issued 13 May 1991
Resolved
INSTALL GUARD ON PORT M/E ALTERNATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Engineering
Issued 13 May 1991
Resolved
MAKE OPERABLE PORT M/E REMOTE SHUTDOWN CABLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Construction/Loadline
Issued 25 October 1990
Resolved
DRYDOCK VESSEL NO LATER THAN 30 NOVEMBER 1990 TO COMPLETE ITEMS ON WORKLISTOF 22OCT90.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Engineering
Issued 2 July 1990
Resolved
ON STBD ENG COOLING WATER TO EXHAUST, RUN HOSE P;ROPERLY SO IT DOESN'T KINK
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Engineering
Issued 2 July 1990
Resolved
DOUBLE HOSE CLAMP ENGINE EXHAUST LINES
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Unknown
Issued 2 July 1990
Resolved
REPLACE WOOD COVERS FOR ENGINE ROOM AC METERS AND MAIN CIRCUIT BREAKER WITH METAL COVERS AND ENCLOSURES.
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Electrical
Issued 2 July 1990
Resolved
REWMOVE UNUSED BILGE PUMP SWITCH
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Fire Fighting
Issued 2 July 1990
Resolved
PROVIDE CG APPROVED BRACKET FOR BII FIRE EXTINGUISHER POORT SIDE LADDER OR PROVIDE CG APPROVED BI FIRE EXT WITH BRACKER FOR PILOT HOUSE
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Fire Fighting
Issued 2 July 1990
Resolved
CLEAN AND REMOVE RUST FROM BII FIRE EXTINGUISHER.
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Electrical
Issued 2 July 1990
Resolved
PROVIDE GLOBE FOR MENS HEAD LIGHT
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Electrical
Issued 2 July 1990
Resolved
PROVIDE RECEPTACLE FOR TV 120VOLT CIRCUIT
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Documentation
Issued 2 July 1990
Resolved
RENEW FCC CERTIFICATES BY 31 AUG90
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Electrical
Issued 2 July 1990
Resolved
REPAIR OR REPLACE 120V GEN PRIOR TO 31AUG 1990
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Electrical
Issued 2 July 1990
Resolved
REPAIR OR REMOVE ENGINE ROOM LIGHTS
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Electrical
Issued 2 July 1990
Resolved
REINFORCE BATTERY BOX BOTTOM (24VDC) OR REINFORCE
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Electrical
Issued 2 July 1990
Resolved
LABEL JUNCTION BOXES IN ENG ROOM FWD BULKHEAD
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Engineering
Issued 2 July 1990
Resolved
MAKE PROPER CONNECTION TO BILGE PUMP OVERBOARD LINE PORT SIDE.
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Engineering
Issued 2 July 1990
Resolved
RENEW SALTWATER LINE TO PORT ENGINE
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Engineering
Issued 2 July 1990
Resolved
CAP OFF GENERATOR SALTWATER SEA SUCTION LINE WHILE GENERATOR IS BEING OVER-HAULED.
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Electrical
Issued 27 June 1989
Resolved
WIRE FATHOMETER TO MAIN 24 VOLT DC PILOTHOUSE PANEL.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Electrical
Issued 27 June 1989
Resolved
MAKE GENERATOR FUEL LINES FROM FUEL FILTER TO GEN AND RETURN LINES WITH METAL PIPING & APPROVED FLEX HOSE LESS THAN 30 INCHES LONG.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Electrical
Issued 27 June 1989
Resolved
MAKE PERMANENT REPAIRS TO AC GENERATOR.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Electrical
Issued 2 June 1988
Resolved
RENEW GENERATOR AIR INTAKES BOX COVER.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Electrical
Issued 2 June 1988
Resolved
PROVIDE PROPER COVER FOR MAIN GEN JUNCTION BOX AND MAIN BREAKER BOX.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Electrical
Issued 2 June 1988
Resolved
RENEW MAIN ENGINE BATTERY BOX.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Engineering
Issued 2 June 1988
Resolved
RENEW PORT & STBD MAIN ENGINE SALT WATER INTAKES HOSE.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Engineering
Issued 2 June 1988
Resolved
PROVIDE CHAFING GUARD ON ACC HOSES RUBBING ON METAL.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Electrical
Issued 2 June 1988
Resolved
PROVIDE FUSE BOX FOR 12 VOLT BATTERY CIRCUITS.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Engineering
Issued 2 June 1988
Resolved
MAKE OPERATIONAL PORT MAIN TACHOMETER.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Navigation
Issued 30 July 1986
Resolved
PROVIDE FCC STATION LICENSE
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Navigation
Issued 30 July 1986
Resolved
PAINT LIGHT SCREENS MAT, BLACK.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Lifesaving
Issued 30 July 1986
Resolved
PROVIDE THREE (3) OPERATIONAL LIFE FLOAT LIGHTS ON LIFE FLOATS.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Lifesaving
Issued 30 July 1986
Resolved
MAKE RING BUOY LIGHT LINE SECURE TO RING BUOY
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Unknown
Issued 30 July 1986
Resolved
PROVIDE ENGINE ROOM COMPARTMENT WITH POLLUTION PLACARD.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Electrical
Issued 30 July 1986
Resolved
PROVIDE PROPER ELECTRICAL CABLE FOR SHORETIE BOX TO CIRCUIT BREAKER PANEL.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Engineering
Issued 30 July 1986
Resolved
PROVIDE RACOR FILTER COVERS.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Electrical
Issued 30 July 1986
Resolved
PROVIDE VOLT, AMPERE, AND CYCLE METERS FOR AC GENERATOR.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Lifesaving
Issued 30 July 1986
Resolved
PROVIDE ONE (1) ADDITIONAL ADULT AND ONE (1) ADDITIONAL CHILD PFD.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986