Records from 1984 to 2012. Most recent: inspection, 30 January 2012.
Inspection history · 54
30 January 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4234771
26 August 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4149366
17 February 2011
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3947539
15 February 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3947294
27 October 2010
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3879281
24 March 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3706031
2 February 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3673710
17 December 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3652427
24 December 2008
Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3378100
6 November 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3357129
15 August 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3305095
7 August 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3291988
28 March 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3175190
11 January 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3175341
27 November 2007
Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3105161
19 January 2007
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2860350
11 January 2007
Internal Structural Exam · Deficiency Check · Annual Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2854008
28 January 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2588241
7 December 2004
Examination of Repairs · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2254764
12 December 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1963114
5 December 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1729812
25 November 2002
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1710227
4 June 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1626315
26 April 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1609668
21 June 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384801
9 May 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403135
18 January 2000
Type not recorded
No type recorded · CGC POINT BAKER · USCG Heartland District (CGD-H) · Activity 1515605
1 June 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423188
20 September 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 38140
4 May 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409901
5 February 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 776571
2 May 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461821
2 May 1996
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1385706
23 May 1995
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1187405
20 March 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 868415
17 January 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 759999
14 January 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 195321
9 September 1994
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 461420
19 May 1994
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466878
27 May 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431228
28 May 1992
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1256736
15 April 1992
Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1269386
30 May 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1217976
31 May 1990
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1218035
27 November 1989
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232096
2 June 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1206668
2 June 1988
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 886790
9 December 1987
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1313871
5 June 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314689
9 June 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000059
11 December 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988539
13 June 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981557
21 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975695
15 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975694
Fire Fighting › Fire Hoses › Condition
Issued 30 January 2012
Resolved
One 50' foot length of 1 1/2" fire hose leaking. Fire hose was destroyed in presence of marine inspectors.
Action required: 705 - Other - as specified
Due 7 February 2012
Resolved 31 January 2012
Resolution: New fire hose purchased.
Lifesaving › Lifebuoys › Approval
Issued 30 January 2012
Resolved
One lifebuoy had no uscg approval. Lifebuoy removed from vessel.
Action required: 705 - Other - as specified
Due 7 February 2012
Resolved 31 January 2012
Resolution: Lifebuoy with uscg approval purchased.
Construction/Loadline › Hull › Bottom Plating
Issued 22 February 2011
Resolved
Proceed to Superior Shipyard in Golden Meadows to complete repairs of the bottom hull plating that was punctured during grounding on rocks.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2011
Construction/Loadline › Hull › Bottom Plating
Issued 17 February 2011
Resolved
Crop and renew damaged plating to original scantling with approved aluminum plate.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 March 2011
Resolved 11 March 2011
Construction/Loadline › Hull › Longitudinal Frame
Issued 17 February 2011
Resolved
Survey the internal structures of the entire vsl and crop and renew damaged framing/longitudinals to original and to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 17 February 2011
Resolved
Renew the three damaged propellers to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2011
Engineering › Fuel Oil Service System › Valve
Issued 27 October 2010
Resolved
Port fuel oil emergency shutoff valve reach rod is broken
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2010
Resolution: Entered in error
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 October 2010
Resolved
Port side fuel shut off reach rod is broken.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 October 2010
Resolved
Lagging on port inbd engine not properly fastened
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 8 November 2010
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 27 October 2010
Resolved
Port inbd and stbd out board tachometers on the bridge do not work. Not required on old - T needs to remove or repair.
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 8 November 2010
Electrical › Electric Generation Source (service) › Generator
Issued 2 February 2010
Resolved
Both service generators overspeed settings were not set properly and the armatures and windings in both need to be cleaned.
Condition: Improper/Lack of Maintenance
Due 2 March 2010
Resolved 10 February 2010
Resolution: Both generator armatures and windings were inspected and cleaned and the overspeeds were adjusted.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 2 February 2010
Resolved
Vessel did not have an up to date set of charts onboard for the operating area it worked in.
Condition: Improper/Lack of Maintenance
Due 2 March 2010
Resolved 10 February 2010
Resolution: Vessel has updated paper charts and updated cartography card for electronic chartplotter unit.
Fire Fighting › Fire Hoses › Condition
Issued 2 February 2010
Resolved
Vessel had one fire hose that was worn through and leaking and one hose that would not connect to the portable foam eductor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2010
Resolution: All fire hoses were replaced with new and correct fitting sizes.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 February 2010
Resolved
All fire extinguishers onboard the vessel had not been serviced/ inspected since 12/2008.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2010
Resolution: All fire extinguishers were serviced and inspected by a third party, attending marine inspector reviewed the third party certificate.
Lifesaving › Lifefloat › Serviceable
Issued 2 February 2010
Resolved
(1) of the vessels 25 person lifefloats had a 4 inch rip in the outer shell, inside material appeared to be saturated. Was noted on CG 835 that until the lifefloat was either repaired by a service facility or replaced that the passenger capacity would be diminished by 25.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2010
Resolution: The lifefloat was serviced and repaired by certified facility and placed back on the vessel.
Engineering › Fuel Oil Service System › Piping
Issued 2 February 2010
Resolved
A crimped fuel pipe was found beneath the centerline deck plates in front of the Main Engines.
Condition: Improper Installation
Due 2 March 2010
Resolved 10 February 2010
Resolution: Crimped fuel line was replaced with new line and fitting.
Engineering › Fuel Oil Service System › Piping
Issued 2 February 2010
Resolved
Numerous compression type fittings were discovered on the fuel piping system of the vessel.
Condition: Improper Installation
Due 2 March 2010
Resolved 10 February 2010
Resolution: Replaced all compression fittings were replaced with flare type fittings.
Documentation › Logs/Records › Logbook (official)
Issued 2 February 2010
Resolved
Vessel has not been making proper log entries for pre arrival and departure checks
Condition: Unknown
Due 2 March 2010
Resolved 10 February 2010
Resolution: Logs have been updated to reflect checks.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 2 February 2010
Resolved
Vessel had EAP information displayed, when the contact numbers were called all three phone numbers were out of service.
Condition: Unknown
Due 2 March 2010
Resolved 10 February 2010
Resolution: All EAP numbers have been updated and were tested in presence of the attending marine inspector.
Communications › Radio Communications › EPIRB
Issued 2 February 2010
Resolved
Vessels EPIRB registration was expired
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2010
Resolution: Vessel''s EPIRB registration was updated.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 February 2010
Resolved
Numerous lights in the engine room were found to be extinguished.
Condition: Improper/Lack of Maintenance
Due 2 March 2010
Resolved 10 February 2010
Resolution: All extinguished lights were replaced and burning brightly.
Engineering › Fuel Oil Service System › Filter
Issued 2 February 2010
Resolved
Two of the six fuel filter assemblies were missing flame shields.
Condition: Improper/Lack of Maintenance
Due 2 March 2010
Resolved 10 February 2010
Resolution: Both missing flame shields have been replaced.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 27 November 2007
Resolved
Oil piping used to fill the starboard generator was not properly blanked off.
Action required: 705 - Other - as specified
Resolved 7 December 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 November 2007
Resolved
Several sections of exhaust lagging were not properly attached throughout the engine room.
Action required: 705 - Other - as specified
Resolved 7 December 2007
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 27 November 2007
Resolved
Wiring for the engine temperature gauges needed to be secured with metal bands.
Action required: 705 - Other - as specified
Resolved 7 December 2007
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 November 2007
Resolved
Non-conductive matting was not present at the switchboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2007
Navigation › Piloting/Steering › Marine Charts
Issued 11 January 2007
Resolved
Renew nav charts for areas transitted.
Due 11 February 2007
Resolved 12 January 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 January 2007
Resolved
Post lifejacket donning placard for proper style of lifejackets.
Due 11 February 2007
Resolved 12 January 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 11 January 2007
Resolved
Properly label emergency escape hatch in engine room.
Due 11 February 2007
Resolved 12 January 2007
Fire Fighting › Portable Foam Applicators › General
Issued 11 January 2007
Resolved
Provide proper eductor or adapter for current eductor for foam firefighting equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2007
Stability › Watertight Integrity
Issued 12 December 2003
Resolved
Fwd escape hatch required adjusting in order for it to be watertight.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2004
Resolved 12 December 2003
Resolution: Adjusted dogs to create a watertight seal. This was completed prior to departure from the vessel.
Lifesaving › Lifejacket/PFD (General)
Issued 12 December 2003
Resolved
Cracked retro reflective tape on 17 life preservers LEGACY COMPONENT DESC: Retro reflective Material
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2004
Resolved 15 December 2003
Resolution: Replaced retroreflective tape on 17 id''''d lifepreservers.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 December 2003
Resolved
Only had a copy of COD. Need to get a new copy of COD from VDOC.
Condition: Unknown
Due 12 January 2004
Resolved 15 December 2003
Resolution: applied for new COD and will be recieving it next week.
Accommodation/Occupational Safety › Cooking Systems
Issued 12 December 2003
Resolved
Missing Latch to prevent stove from opening.
Due 12 January 2004
Resolved 15 December 2003
Resolution: Installed slide latch that will prevent the stove from opening
Documentation
Issued 2 May 1996
Resolved
PROVIDE VERIFICATION OF UPDATED SAFETY RADIOTELEPHONE LICENSE.
Condition: Unknown
Due 2 June 1996
Resolved 15 May 1996