Records from 1992 to 2011. Most recent: inspection, 3 August 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 37
3 August 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4104265
26 July 2011
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4094708
12 October 2010
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3872231
9 July 2009
Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3530041
11 September 2008
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3323149
13 September 2007
Annual Inspection · Internal Structural Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3068081
25 July 2007
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3006030
28 March 2007
Damage Survey · Construction Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2924207
14 July 2006
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2715841
12 September 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2493138
6 July 2005
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2422824
19 April 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2047438
6 October 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1922432
2 October 2003
Hull Examination · Examination of Repairs · Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1919395
12 September 2002
Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1674506
10 June 2002
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1636747
13 May 2002
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1627175
7 June 2001
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1376724
21 August 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1382044
12 April 2000
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1464946
15 September 1999
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1120967
24 June 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 773394
10 December 1998
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 807745
23 July 1998
Deficiency Check · Inclining Experiment
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 800277
21 May 1998
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1127208
3 April 1998
Deficiency Check · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1123614
2 September 1997
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1123459
8 July 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1446516
1 May 1997
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1099973
15 May 1996
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1083229
7 June 1995
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 884459
7 June 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1449836
4 May 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1178649
10 February 1994
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 853297
25 May 1993
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1139195
27 May 1992
Initial Certification · Plan Review "T" Boat
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1266579
14 April 1992
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 952656
Construction/Loadline › Hull › Bottom Plating
Issued 26 July 2011
Resolved
Re-caulk port side forward plank as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: Port side was re-caulked and coated with Interlux underwater seam compound.
Construction/Loadline › Hull › Bottom Plating
Issued 26 July 2011
Resolved
Re-caulk starboard side in 03 spots as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: Replaced 01 plank, re-caulked starboard side and coated with Interlux underwater seam compound.
Construction/Loadline › Penetrations › Bottom Plug
Issued 26 July 2011
Resolved
Re-seal and install 03 bungs starboard side as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: Re-sealed 03 bungs and coated with Interlux underwater seam compound.
Construction/Loadline › Hull › Transverse Frame
Issued 26 July 2011
Resolved
Port side transom, fill in small checking area as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: Re-caulked and coated with Interlux sealing compound.
Construction/Loadline › Hull › Side Shell
Issued 12 October 2010
Resolved
While underway, small leak noted in the port bow in the vicinity of the chine. Repair to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2010
Resolution: A 24" section of packing replaced port side in the vecinity of the chine. A 20 minute check ride on the vessel confirmed that the repair was to the satisfaction of the CG marine inspector.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 July 2009
Resolved
Rot on the plank above chine in forward compt to include 2 full spaces starboard and 3 full spaces port. Additional rot on chine and transverse rib in vicinity of plank rot. Prepare a repair proposal and submit to OCMI prior to conducting any repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2009
Resolution: Plank aboce chine repaired to the satisfaction of the CG marine inspector.
Construction/Loadline › Hull › Side Shell
Issued 9 July 2009
Resolved
Rot on the exterior starboard side forward in the vicinity of the stem. Prepare a repair propsal and forward to OCMI for review prior to conducting any repairs to vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2009
Resolution: Repair to the exterior starboard side in vicinity of the stem satisfactory to the CG Marine Inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 July 2009
Resolved
Fixed CO2 fire exinguishing system not UL listed or CG approved. Replace as new with a CG approved UL listed system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2009
Resolved 15 April 2010
Resolution: Exsiting CO2 fire extinguishing system is CG approved and all parts are UL listed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 July 2009
Resolved
Water observed entering near the first frame port side near chine. Determine source of leak and submit a repair proposal to CG Marine Inspector prior to making repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2009
Resolved 15 April 2010
Resolution: Proper repairs made to the area near the 1st frame port side chine. A 15 minute underway test showed no signs of leakage in the area of repairs.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 July 2009
Resolved
Water observed entering in stern of vessel in the vicinity of the strut pad. Determine the source of the leak and submit a repair proposal to CG Marine Inspector for review prior to making repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2009
Resolved 15 April 2010
Resolution: Proper repairs made to the stern of the vessel in vicinity of the strut pad. A 15 minute underway test revealed that there were no leaks in the area of repair.
Construction/Loadline › Structures › Superstructure
Issued 9 July 2009
Resolved
Port side bridge window cracked - replace as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2009
Resolved 15 April 2010
Resolution: Bridge windows replaced.
Construction/Loadline › Structures › Manhole
Issued 9 July 2009
Resolved
Lanyards missing from hatches o/b vessel. Install lanyards on every hatch as directed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2009
Resolved 15 April 2010
Resolution: Lanyards added to the hatches.
Construction/Loadline › Hull › Keel
Issued 14 September 2007
Resolved
Keel was found to be wasted to the first void space forward of the steering compartment. Excessive leaking was found in the space when the vessel was floated.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2008
Resolution: Area around keel was repaired.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 September 2007
Resolved
Excessive water leaking into the spaces along port and starboard chine, port side aft corner, port side adjacent to the battery boxes, stbd side forward of new repairs under cabin, and one area aft of new repairs.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2008
Resolution: Areas at chine were repaired around the entire length of the vessel.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 13 September 2007
Resolved
Vessel has the correct amount of Fire Extinguishers onboard. However, one of their B-II portable extinguishers was empty.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2008
Resolution: Vessel placed new B-II extinguisher onboard.
Engineering › Bilge Water Management System › Pump
Issued 13 September 2007
Resolved
Provide portable hand bilge pump with enough discharge hose capable of reaching overboard from the cabin.
Due 1 May 2008
Resolved 21 April 2008
Resolution: Hand bilge pump purchased and placed onboard.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 September 2007
Resolved
Post a current and original COI onboard vessel.
Due 1 May 2008
Resolved 21 April 2008
Resolution: Vessel received new COI.
Construction/Loadline › Hull › Stiffener
Issued 13 September 2007
Resolved
Vessel rep ordered to effect repairs to numerous areas of the hull to stop leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2008
Resolution: Repairs made to damaged areas.
Engineering › Steering Gear System › Rudder
Issued 13 September 2007
Resolved
Rudder packing glands leaking excessively into vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2007
Resolution: Rudder Post leaks were repaired and showed no leaks while vessel was in the water.
Lifesaving › Lifefloat › Serviceable
Issued 13 September 2007
Resolved
Vessel's current 22 Person Life float is no longer good and serviceable. Excessive damage was noted on the entire exterior. Vessel will need to replace life float if operated during cold water months.
Due 1 May 2008
Resolved 21 April 2008
Resolution: Vessel removed lifefloat from vessel. Max persons allowed on vessel during warm weather months is 16.
Lifesaving › Lifefloat › Serviceable
Issued 13 September 2007
Resolved
Vessel's 07 person Life Float has a small, 1" piece missing. Vessel Rep will buy a repair kit and fix Life Float.
Due 1 May 2008
Resolved 21 April 2008
Resolution: Area around lifefloat was repaired.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 September 2007
Resolved
Vessel's original, current COD was not present on the vessel.
Due 1 May 2008
Resolved 21 April 2008
Resolution: Vessel has new COD onboard.
Electrical › Electric Supply System (service) › Cable
Issued 25 July 2007
Resolved
Replace welding cable on anchor winch with UL approved boat electric cable.
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 27 July 2007
Resolution: Visited vessel, approved replacement cable.
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 25 July 2007
Resolved
Renew brackets for hydraulic oil tank.
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 27 July 2007
Resolution: Visited vessel, observed new replacement brackets.
Electrical › Electric Supply System (service) › Cable
Issued 25 July 2007
Resolved
Remove or secure properly all wires in cabin compartment.
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 27 July 2007
Resolution: Visited vessel, observed all wires properly attached.
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2007
Resolved
Prior to carrying passengers conduct a underway check ride following repairs to transom and steering.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2007
Resolved 2 May 2007
Resolution: satisfactory check ride completed following satisfactory repairs.
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 14 July 2006
Resolved
Repair small leak in exhaust at elbow in laz.
Due 21 July 2006
Resolved 27 July 2006
Resolution: repair completed.
Construction/Loadline › Hull › Sheerstrake
Issued 14 July 2006
Resolved
Make repairs to plank portside one up from chine.
Due 21 July 2006
Resolved 27 July 2006
Resolution: vessel hauled and repairs completed.
Construction/Loadline › Hull › Bottom Plating
Issued 12 September 2005
Resolved
Make repairs to planking where leaking, starbord side under fuel filter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2005
Resolved 13 September 2005
Resolution: Repairs made, check ride sat.
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 September 2005
Resolved
Make repairs to leaking stuffing box port shaft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2005
Resolved 13 September 2005
Resolution: Stufing box repacked.
Lifesaving › Lifebuoys
Issued 19 April 2004
Resolved
Replace ring buoy grab line.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2004
Resolved 14 May 2004
Resolution: New ring buoy provided.
Lifesaving › Buoyant Apparatus
Issued 19 April 2004
Resolved
Replace or renew seven person life float.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2004
Resolved 14 May 2004
Resolution: New life float purchased and installed correctly.
Lifesaving › Buoyant Apparatus
Issued 19 April 2004
Resolved
Replace weak link for twenty two person life float with correct size.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2004
Resolved 19 April 2004
Resolution: New weak link provided.
Electrical › Electrical Distribution System (service)
Issued 19 April 2004
Resolved
Install cover for console electrical.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2004
Resolved 19 April 2004
Resolution: Cover installed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 19 April 2004
Resolved
Show proper operation of port engine tach.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2004
Resolved 19 April 2004
Resolution: Proper operation demonstrated.
Construction/Loadline › Hull
Issued 19 April 2004
Resolved
Make all necessary repairs to hull where indicated and discussed with operator and ship wright.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2004
Resolved 19 April 2004
Resolution: Vessel hauled and repairs completed.
Lifesaving › Line-Throwing Appliances
Issued 6 October 2003
Resolved
Provide 3/8 inch line for life ring water light lanyard. LEGACY COMPONENT DESC: Lines
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Lifesaving › Buoyant Apparatus
Issued 6 October 2003
Resolved
Provide reflective tape on buoyant appartatus
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Lifesaving › Buoyant Apparatus
Issued 6 October 2003
Resolved
Provide 18 ft of line for waterlight on BA & Lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Lifesaving › Lifebuoys
Issued 6 October 2003
Resolved
Label lifefloat paddles.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Lifesaving › Lifebuoys
Issued 6 October 2003
Resolved
Repair cracks in life float.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 21 October 2003
Lifesaving › Buoyant Apparatus
Issued 6 October 2003
Resolved
Fasten painter to BA/life float hull.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Lifesaving › Buoyant Apparatus
Issued 6 October 2003
Resolved
Provide weak link for BA and lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 21 October 2003
Communications › Alarms/Indicators
Issued 6 October 2003
Resolved
Provide lights for high water bilge alarms. LEGACY COMPONENT DESC: High Water Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 6 October 2003
Resolved
Mount BII fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 6 October 2003
Resolved
Provide donning instructions for Kapok PFD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Electrical › Electrical Distribution System (service)
Issued 6 October 2003
Resolved
Provide cover for bus bar behind console.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 6 October 2003
Resolved
Label PFD stowage. Provide separate stowage for child PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Engineering › Fuel Oil Service System
Issued 6 October 2003
Resolved
Provide second hose clamp for port MDE fuel line return.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Engineering › Steering Gear System
Issued 6 October 2003
Resolved
Tighten rudder post packing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Electrical › Electrical Distribution System (service)
Issued 6 October 2003
Resolved
Secure wires in bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 7 October 2003
Construction/Loadline
Issued 21 August 2000
Resolved
PROVIDE GASKET AND LATCHES TO MAKE ENGINE BOXS WATERTIGHT.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Construction/Loadline
Issued 12 April 2000
Resolved
REPLACE BOTTOM PLANK ON TRANSOM.
Condition: Unknown
Due 18 April 2000
Resolved 1 June 2000
Construction/Loadline
Issued 12 April 2000
Resolved
REPLACE BOTTOM PLANK ON PORTSIDE 10-FT AFT OF BOW 4-FT OUT FROM KEEL.
Condition: Unknown
Due 18 April 2000
Resolved 1 June 2000
Construction/Loadline
Issued 12 April 2000
Resolved
REPLACE BOTTOM PLANK STARBOARD SIDE IN VOID BELOW PILOTHOUSE.
Condition: Unknown
Due 18 April 2000
Resolved 1 June 2000
Fire Fighting
Issued 24 June 1999
Resolved
PROVIDE PERMANENT INSTALLATION FOR FIXED FIRE EXTINGUISHER.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Accommodation/Occupational Safety
Issued 24 June 1999
Resolved
MAKE HANDRAIL ACROSS STERN CONTINUOUS.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Navigation
Issued 24 June 1999
Resolved
PROVIDE PROPER VERTICAL SPACING BETWEEN MASTHEAD LIGHT AND SIDE LIGHTS.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Fire Fighting
Issued 24 June 1999
Resolved
COMPLETE BULKHEADS FORWARD, AFT AND OUTBOARD OF MDE'S.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 24 June 1999
Resolved
MOVE ALL ALARMS AND INDICATORS TO OPERATING STATION.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Navigation
Issued 24 June 1999
Resolved
PROVIDE PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Accommodation/Occupational Safety
Issued 24 June 1999
Resolved
PROVIDE CREW ONLY SIGN AT LADDER TO UPPER DECK.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Navigation
Issued 21 May 1998
Resolved
PROVIDE NEW MASTHEAD LIGHT. LIMITED TO DAYLIGHT OPERATION ONLY UNTIL CORRECTED.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Documentation
Issued 21 May 1998
Resolved
PROVIDE CURRENT FCC OPERATORS LICENSE.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Lifesaving
Issued 21 May 1998
Resolved
PROVIDE 5 ADDITIONAL ADULT PFD'S. VESSEL IS LIMITED TO 44 PERSONS UNTIL COMPLETED.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Documentation
Issued 21 May 1998
Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Lifesaving
Issued 21 May 1998
Resolved
PROVIDE NEW L/F. VESSEL LIMITED TO 23 PERSONS (21 PASSENGERS) UNTIL COMPLETED.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Lifesaving
Issued 21 May 1998
Resolved
PROVIDE NEW REFLECTIVE TAPE FOR 7 PERSON BUOYANT APPARATUS. VSL LIMITED TODAYLIGHT OPERATION ONLY UNTIL COMPLETED.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Engineering
Issued 8 July 1997
Resolved
Replace flexible fuel hose with USCG approved fuel hose._x001C_
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Documentation
Issued 8 July 1997
Resolved
Provide valid FCC station license._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Construction/Loadline
Issued 8 July 1997
Resolved
Address leak at outboard backing block for starboard strut.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Lifesaving
Issued 8 July 1997
Resolved
Repair surface of one adult PFD.
Condition: Unknown
Due 22 July 1997
Resolved 21 July 1997
Lifesaving
Issued 15 May 1996
Resolved
The painter on the 7 man bouyant apparatus. Line is deteriorated._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1996
Resolved 16 May 1996
Lifesaving
Issued 15 May 1996
Resolved
The safety line on the 7 man bouyant apparatus is deteriorated._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1996
Resolved 16 May 1996
Lifesaving
Issued 15 May 1996
Resolved
The retro reflective tape on the B/A's are worn._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1996
Resolved 16 May 1996