Records from 1984 to 2003. Most recent: inspection, 12 September 2003.
Inspection history · 58
12 September 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1924965
2 August 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1879619
3 October 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1686078
28 August 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1667617
29 May 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1626166
20 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607015
25 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073134
29 May 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452819
13 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064147
14 April 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061606
1 March 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 117553
19 January 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 825338
9 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 84079
8 September 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 822385
31 May 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1361552
30 November 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 812697
10 November 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 806085
1 June 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402885
31 May 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2555
24 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799903
5 August 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 796641
4 June 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468450
6 May 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791370
10 December 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 138535
1 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774904
19 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1108537
13 August 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1120821
4 August 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1117847
21 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115605
3 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777984
2 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777373
9 June 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1437265
24 January 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762245
23 January 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 190116
13 June 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390278
28 February 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1081358
26 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 873343
26 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1079150
23 July 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 879750
15 June 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1450986
22 August 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 870987
9 June 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398101
13 July 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 846842
12 July 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 843915
28 June 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1157570
27 June 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 52287
23 June 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1153309
9 June 1993
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434015
11 June 1992
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1141341
30 July 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 934337
12 June 1991
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1230760
12 June 1989
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 902227
20 June 1988
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 896118
29 June 1987
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1316667
2 July 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 987602
14 May 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1291303
25 September 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 979003
16 May 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1281998
Construction/Loadline
Issued 31 May 2000
Resolved
Crop and renew wasted cleats - 1 at port midship and 1 at starboard midship.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 1 June 1999
Resolved
Provide approved plans for paint locker fixed CO2 system, and conduct satisfactory test in presence of uscg or class surveyor.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Lifesaving
Issued 5 August 1998
Resolved
CONDUCT LIFEBOAT RELEASE GEAR TEST UNDER A LOAD OF 1.1 TIMES THE TOTAL MASSOF THE LIFEBOAT WHEN LOADED WITH ITS FULL COMPLEMENT OF PERSONS AND EQUIPMENT.
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Lifesaving
Issued 9 June 1997
Resolved
PROVE CURRENT EXPIRATION DATES FOR EXISTING RING BUOY SMOKES OR PROVIDE 2 NEW ONES.
Condition: Unknown
Due 24 June 1997
Resolved 16 July 1997
Fire Fighting
Issued 9 June 1997
Resolved
REPAIR NOZZLE LEAKS AT FIRE STATIONS #6,3,AND 2.
Condition: Unknown
Due 24 June 1997
Resolved 16 July 1997
Accommodation/Occupational Safety
Issued 9 June 1997
Resolved
REPLACE/REPAIR WASTED RAILING IN WAY OF LIFEBOAT STATION #2.
Condition: Unknown
Due 17 June 1997
Resolved 16 July 1997
Lifesaving
Issued 9 June 1997
Resolved
PROVIDE APPROVED HOSE CLAMP FOR SCBA OR REPLACE IN KIND.
Condition: Unknown
Due 17 June 1997
Resolved 16 July 1997
Construction/Loadline
Issued 9 June 1997
Resolved
CROP AND RENEW WASTED OVERHEAD FRAMES/STRENGTH MEMBERS IN MUD PIT ROOM.
Condition: Unknown
Due 9 July 1997
Resolved 30 July 1997
Documentation
Issued 9 June 1997
Resolved
MAKE FIRE SAFETY PLAN UPDATES TO ACCURATELY REFLECT NEW GALLEY, MOTOR ROOM EXTINGUISHERS.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Construction/Loadline
Issued 9 June 1997
Resolved
FULLY WELD DRILL WATER PIPE AT BULKHEAD INTERSECTION AT STBD SIDE MUD PIT ROOM.
Condition: Unknown
Due 9 July 1997
Resolved 16 July 1997
Fire Fighting
Issued 9 June 1997
Resolved
PROVE ALL PORTABLE AND SEMIPORTABLE FIRE EXTINGUISHERS ARE WITHIN HYDRO TEST DATES BY PANAMANIAN RULES.
Condition: Unknown
Due 17 June 1997
Resolved 16 July 1997
Electrical
Issued 9 June 1997
Resolved
PROVIDE PROPER ILLUMINATION TO BOTH LIFEBOAT EMBARKATION AREAS.
Condition: Unknown
Due 17 June 1997
Resolved 16 July 1997
Lifesaving
Issued 9 June 1997
Resolved
PROVIDE NEW LIFE RING BUOYS FOR PORT/STARBOARD KEYWAY STATIONS AND PORT SIDE STATION ADJACENT TO LIFE RAFT #3.
Condition: Unknown
Due 17 June 1997
Resolved 16 July 1997
Lifesaving
Issued 9 June 1997
Resolved
LABEL SIREN ON AFT OUTSIDE OF ACCOMODATIONS SPACE.
Condition: Unknown
Due 17 June 1997
Resolved 16 July 1997
Documentation
Issued 9 June 1997
Resolved
PROVIDE COPY OF REPORT TO SURVEYOR FOR PANAMA BUREAU OF SHIPPING TO THE _x001C_ U.S. COAST GUARD ON REPAIRS TO THE PRELOAD TANK #1.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Lifesaving
Issued 9 June 1997
Resolved
REPAIR PURGE ALARM IN DRILL MONITOR
Condition: Unknown
Due 17 June 1997
Resolved 16 July 1997
Lifesaving
Issued 9 June 1997
Resolved
REPAIR/RENEW WASTED HELODECK SAFETY NETTING WHERE WORN AS WELL AS WASTED SAFETY NETTING SUPPORTS.
Condition: Unknown
Due 17 June 1997
Resolved 16 July 1997
Fire Fighting
Issued 13 June 1996
Resolved
PROVIDE LATCHES FOR ALL CLASS "A" DOORS.
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Navigation
Issued 13 June 1996
Resolved
ENSURE FOGHORN INTERVAL IS 2 SECONDS ON, 18 SECONDS OFF.
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Lifesaving
Issued 13 June 1996
Resolved
PROVIDE BOARDING LADDERS FOR BOTH LIFEBOATS.
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Documentation
Issued 13 June 1996
Resolved
PROVIDE FULL TERM MODU SARETY CERTIFICATE.
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Documentation
Issued 15 June 1995
Resolved
Provide a list of exemptions from IMO MODU code being applied to rig. Specificly comment on exemptions granted for the following: helo deck lighting and overspeed controls on main generator prime mover.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Construction/Loadline
Issued 15 June 1995
Resolved
Repair/replace leaking seal to bilge pump #2 in motor room.
Condition: Unknown
Due 15 July 1995
Resolved 7 July 1995
Electrical
Issued 15 June 1995
Resolved
Repair exposed wires to electric pump for drill water in motor room.
Condition: Unknown
Due 15 July 1995
Resolved 7 July 1995
Electrical
Issued 15 June 1995
Resolved
Install and hard wire battery charge to batteries located under stair way in motor room.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Electrical
Issued 15 June 1995
Resolved
Install blank or circuit breaker in open block of 220V circuit breaker panel in motor room.
Condition: Unknown
Due 15 July 1995
Resolved 7 July 1995
Fire Fighting
Issued 15 June 1995
Resolved
Repair/replac nozzle at fire station #12 in mud pump room.
Condition: Unknown
Due 15 July 1995
Resolved 7 July 1995
Accommodation/Occupational Safety
Issued 9 June 1994
Resolved
Provide Statement of Fact from flag state representative attesting to the following inspections/tests: 1) Internal exams of pressure vessels including bulk tanks. 2) Test relief valves on drilling air receivers.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Lifesaving
Issued 9 June 1994
Resolved
Replace General Alarm actuator on drill floor with explosion proof type.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Electrical
Issued 9 June 1994
Resolved
Provide emergency lighting of helicopter deck as per IMO MODU Code 5.3.2.1.8 and Panamanian Technote 1/83 Part "B".
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Electrical
Issued 9 June 1993
Resolved
CLEAN PERIMETER LIGHTS ON HELO DECK.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Electrical
Issued 9 June 1993
Resolved
PERMANENTLY INSTALL GAS DETECTOR WIRE AND J-BOX FROM SHALE SHAKER TO DRILLER'S CONSOLE.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Lifesaving
Issued 9 June 1993
Resolved
PROVE PROPER OPERATION OF INTERIOR LIGHTS FOR L/B #1.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Fire Fighting
Issued 9 June 1993
Resolved
REPLACE OR INSTALL KEEPER CHAINS ON NOZZLE TIPS AS REQUIRED AT ALL FIRE STATIONS.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Accommodation/Occupational Safety
Issued 9 June 1993
Resolved
INSTALL ASME APPROVED RELIEF VALVES ON TWO (2) S/S AIR RECEIVERS AND DRILL FLOOR AIR RECEIVER WITH RELIEVING HANDLES AND NOT MORE THAN MAWP.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Lifesaving
Issued 9 June 1993
Resolved
CLEAN LENSES ON ALL WATERLIGHTS.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Lifesaving
Issued 9 June 1993
Resolved
PROVIDE MOUNTING BRACKET FOR WATERLIGHT UNDER V-DOOR.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Lifesaving
Issued 9 June 1993
Resolved
PROPERLY SET TENSION ON HYDROSTATIC RELEASES ON LIFERAFTS.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Engineering
Issued 9 June 1993
Resolved
INSTALL FLAME SCREEN ON DIESEL FUEL TANK VENT FOR HALLIBURTON UNIT.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Electrical
Issued 9 June 1993
Resolved
RELOCATE TRANSFORMER FOR SCHLUMBERGER WIRELINE UNIT OUTSIDE THE HAZARDOUS AREA.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Electrical
Issued 9 June 1993
Resolved
PROVIDE PROPER VENTILATION FOR MAIN POWER BREAKER FOR DC BOARD AND REINSTALL COVER TO BOX.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Electrical
Issued 9 June 1993
Resolved
REPLACE MISSING BOLT ON EXPLOSION PROOF BOX FOR OUTBOARD MUD CLEANER ON/OFFSWITCH AT DEGASSER UNIT.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Lifesaving
Issued 9 June 1993
Resolved
ADJUST EYEWASH UNIT AT SHAKER SO THAT HANDLE IS NOT JAMMED AGAINST RAIL ANDSTRAIGHTEN HANDLE.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Accommodation/Occupational Safety
Issued 9 June 1993
Resolved
RENEW DECK GRATING ANGLE AND HANDRAIL OUTBOARD OF SCHLUMBERGER WIRELINE UNIT.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Electrical
Issued 9 June 1993
Resolved
REMOVE DEAD END WIRE OVER DEGASSER UNIT.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Accommodation/Occupational Safety
Issued 9 June 1993
Resolved
REPLACE DRYER PLASTIC VENT HOSE WITH METAL VENT HOSE.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 11 June 1992
Resolved
PROVE PROPER OPERATION OF TOTAL RIG SHUTDOWN.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Electrical
Issued 11 June 1992
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHT BATTLE LANTERN AT PORT LIFE CAPSULE STATION.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Lifesaving
Issued 11 June 1992
Resolved
PROVIDE SEA ANCHOR FOR 28 MAN LIFE CAPSULE.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Accommodation/Occupational Safety
Issued 11 June 1992
Resolved
RENEW LOWER PRESSURE VESSEL (AIR RECEIVER) IN GENERATOR ROOM DUE TO UNAPPROVED INSERT REPAIR.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Lifesaving
Issued 11 June 1992
Resolved
CHANGE HOMEPORT ON LIFE RINGS TO PANAMA.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Fire Fighting
Issued 12 June 1989
Resolved
PROVIDE TWO INDEPENDANT FIRE PUMPS IAW 8.3 DCMA MODU CODE FOR EXISTING VESSELS. (PITO PRESSURE CHECKED TWO HOSES 16 PSI ON DEEP WELLS).
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Fire Fighting
Issued 12 June 1989
Resolved
REPLACE THE RECALLED ANSUL EX607 HOSE ON THE HELO DECK B-V (150LB UNIT) WITH A EX589 HOSE. (PROVIDED IN EXCHANGE BY ANSUL).
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
PROVIDE ELECTRICAL EQUIPMENT IN THE PAINT LOCKER THAT IS IAW 7.3 & 7.5 DCMA MODU CODE.
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Fire Fighting
Issued 12 June 1989
Resolved
PROVIDE TWO 1-1/2" 50FT FIRE HOSES.
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
RENEW TYPE SO CABLE ON MUD MONITORING ALARM, MSI MOD SENSING PANEL AND PHONE ON THE DRILL FLOOR WITH APPROVED CABLE (7.5 DCMA MODU CODE).
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
MAKE MSI MUD SENSING PANEL INTRINSICALLY SAFE OR PURGE AND OVER PRESSURE IN ACCORDANCE WITH NFPA 496 INCLUDING INSTALLATION OF AN AUDIBLE OR VISUAL LOSS OF PURGE ALARM (7.5 DCMA MODU CODE).
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
ENSURE ALL EYS FITTINGS ON THE DRILL FLOOR, SHALE SHAKER AREA AND MUD PITROOM ARE POURED. POUR ALL THOSE THAT ARE NOT ENSURING THAT CABLE INSULATION IS STRIPPED BACK AS REQUIRED. (7.5 DCMA MODU CODE).
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
REMOVE IMPROPER CABLE SPLICE IN BLOCK OF MARTIN-DECKER PANEL IN INSTALL APPROVED SPLICE OR MAKE THE CABLE A CONTINOUS RUN. (7.5 DCMA MODU CODE).
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
RENEW LIGHT FIXTURE ON THE CUTTINGS CLEANER DECK WITH AN APPROVED HAZARDOUSLOCATION CLASSIFIED FIXTURE.(DCMA 7.5 MODU CODE)
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Construction/Loadline
Issued 12 June 1989
Resolved
REINSTALL THE DOORS FROM THE MUD PUMP ROOM SO THAT THEY OPEN INTO THE MUD PUMP ROOM, WITH POSITIVE MEANS OF CLOSURE, OR CLASSIFY THE MUD PUMP ROOM AS A CLASS I DIVISION II HAZARDOUS LOCATION.(7.5 DCMA MODU CODE)
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
RENEW THE ELECTRICAL KICK PIPES ON THE PORTSIDE OF THE DRILL FLOOR.
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Construction/Loadline
Issued 12 June 1989
Resolved
SEAL ALL NON USED CABLE WAYS AND CLOSE ALL THROUGH BULKHEAD PENETRATIONS IN THE MUDPIT ROOM. (7.5 DCMA MODU CODE.
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
REMOVE UNUSED MARTIN DECKER PANEL LIGHT AND ASSOCIATED ELECTRICAL CABLING (7.5 DCMA MODU CODE).
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
SHOW EVIDENCE THAT THE ELECTRICAL FITTINGS USED ON THE DRILL FLOOR, SHALE SHAKERS AND MUD PIT ROOMS ARE APPROVED FOR HAZARDOUS LOCATIONS. IF NOT, RE-PLACE WITH APPROVED FITTINGS AS EYS FITTINGS. (7.5 DCMA MODU CODE)
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
SHOW EVIDENCE THAT THE WATER COOLER ON THE DRILL FLOOR IS EXPLOSION PROOF OR INTRINSICALLY SAFE. IF IT IS NOT, RENEW WITH INTRINSICALLY SAFE OR EXPLOSION PROOF COOLER. (7.5 DCMA MODU CODE).
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
RENEW EMERGENCY ENGINE STOP SWITCH ON DRILL FLOOR WITH EXPLOSION PROOF OR INTRINSICALLY SAFE SWITCH (7.5 DCMA MODU CODE)
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Unknown
Issued 12 June 1989
Resolved
PROVIDE SAFETY BELTS AND RIDING BELTS THAT MEET ANSI 10:14 33CFR 142.42 (SUB CHAPTER N).
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Electrical
Issued 12 June 1989
Resolved
RENEW THE JUNCTION BOX ON THE OUTSIDE OF THE STARBOARD SIDE OF THE CONTROL (LEG) ROOM (7.5 DCMA MODU CODE).
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Unknown
Issued 16 May 1984
Resolved
INSTALL INDIVIDUAL RELIEF VALVES ON EACH BULK CHEMICAL TANK FOR PROTECTION AGAINST DAMAGE IN ALL MODES OF LOADING.
Condition: Unknown
Due 16 May 1984
Resolved 16 May 1984
Fire Fighting
Issued 16 May 1984
Resolved
PROVIDE EQUIPMENT FOR WEIGHING CO2 CARTRIDGES OF PORTABLE EXTINGUISHERS IN FIELD AND HYDROTEST ALL EXTINGUISHERS MORE THAN 8 YEARS OLD.
Condition: Unknown
Due 16 May 1984
Resolved 16 May 1984