MAURY USCG vessel records Sign in
← All vessels

ROBERT C. SEAMANS

ROBERT C. SEAMANS is a 2001 school ship. The Coast Guard has recorded 46 inspections since 2001, most recently in October 2025, along with 37 deficiencies, 2 operational controls and 2 casualty investigations between 2007 and 2011.

Records from 2001 to 2025. Most recent: inspection, 15 October 2025.

Built
2001
Last inspected
15 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9245483 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA4486
Flag
UNITED STATES
369503000
Maury page id
psix-23381

Inspections, by type

…with no type recorded4
Years with a record 22 calendar years (2001–2025)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)92.9 ft × 25.5 ft × 16.7 ft
Registered tonnagegross 211 / net 104
ITC dimensions (L × B × D)92.9 ft × 25.5 ft × 16.7 ft
ITC tonnagegross 211 / net 104
BuilderJ.M.MARTINAC SHIPBLDG INC · TACOMA, WA, UNITED STATES · built 2001
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWOODS HOLE, MA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 March 2026 · expires 30 April 2027
Service, as the file records itSchool Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it211 - Convention (Subpart B), Gross Ton
104 - Convention (Subpart B), Net Ton
350 - Displacement, Ton
157 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA4486MMSI 369503000 · active · compulsorily equipped · granted 9 March 2021, expires 4 May 2031
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA FALCON Commercial Fishing Vessel · MISLE 54043 · 23 June 2007 · activity 3007482

Inspection history · 46

15 October 2025 Internal Structural Exam · Vessel Attendance · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8253646
13 August 2025 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8150125
7 November 2024 Drydock Exam
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8031672
12 August 2024 Periodic Inspection · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7885553
18 January 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7858342
17 May 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7634736
30 September 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7588450
24 August 2022 Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7548293
14 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7476881
21 April 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7435802
21 June 2021 Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7226406
22 March 2021 Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7160930
2 February 2021 Internal Structural Exam · Examination of Repairs · Hull Examination · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7134437
14 September 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7058028
11 June 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6974012
24 June 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6724505
31 August 2018 Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6532121
27 June 2018 Deficiency Check · Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6457182
8 January 2018 Drydock Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6333880
23 August 2017 In-Service Inspection
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6249086
20 June 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6180977
7 June 2016 COI Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5900559
10 December 2015 Hull Examination · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5778727
13 June 2014 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4890385
5 June 2014 Administrative Inspection · Damage Survey · Plan Review (Other than "T")
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4881267
12 May 2014 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4857044
12 June 2012 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4342046
25 August 2011 Construction Oversight · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4119852
29 July 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4098108
28 July 2011 Deficiency Check · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4102160
27 July 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4109433
16 September 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3326363
4 September 2008 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3278006
22 July 2008 Attraction Vessel Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3268149
6 September 2007 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3008225
23 June 2007 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3007482
5 July 2006 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2702693
26 June 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2692367
2 September 2005 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2480520
8 September 2004 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2191525
2 September 2004 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2168104
22 June 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2134600
20 November 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1951777
28 August 2003 Deficiency Check · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1889655
20 October 2002 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1693067
26 July 2001 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1382373

Deficiency record · 37

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 August 2024 Resolved
Cylinders must be tested and marked on fixed carbon dioxide systems must be tested or renewed, as required by 46 CFR 147.60/147.65. Hydrostatic test for CO2 is at 12 years and requires recertification.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2024
Resolved 15 August 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 August 2024 Resolved
Each crew berthing/public areas shall be equipped with information regarding procedures and resources to report crimes, including sexual assault and sexual harassment (SASH), including information on the telephone number, website address, and email address for reporting allegations of sexual assault and sexual harassment to the Coast Guard. Vessel has no posters/pamphlets posted providing instruction to report directly to USCG. Provide posters that specifically instruct victims to report incidents directly to USCG. Additionally, vessel does not have updated SASH training program as required.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2024
Resolved 9 September 2024
Resolution: Vsl has required signs with phone number and email. However, due to vsl construction, no video monitoring can be accomplished without privacy invasion. Vessel does not have staterooms...it has bunks with curtain over each bunk for privacy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 May 2023 Resolved
Class 1 doors fitting in watertight bulkheads must be equipped with a remote position indicator at the main navigating station of the vessel. The indicators for the saloon and focsle doors were inoperable. Provide door position indicators as required. 46 CFR 173.057(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 23 May 2023
Resolution: The proper operation of the watertight door position indicator lights was verified.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 June 2022 Resolved
Radiotelephone installations are required on certain vessels; a valid certificate issued by the FCC is evidence that the radio installation is in compliance with the requirements of that agency. Every power driven vessel of 20 meters or more length must comply with the requirements in the Bridge-to-Bridge Act. No documentation certifying the installation of the ships radio installation could be provided. Provide a valid Bridge-to-bridge certificate. 46 CFR 169.715 46 CFR 80.1001
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2022
Resolved 15 June 2022
Resolution: Vessel owner provided a 1992 FCC determination stating that the FCC Communications act of 1934 did not apply to this vessel becuase it did not carry passengers. A copy of the determination has been uploaded to vessel documents.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2021 Resolved
Dead end wiring coming through bulkhead penetration in EDG space. Needs to be properly capped or removed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2021
Resolved 25 June 2021
Resolution: Photos and Class report sent to CG MI...[name withheld]
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 June 2020 Resolved
Install emergency egress lighting in way of emergency escape located in the aft head compartment. 46 CFR 112.01-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2020
Resolved 8 July 2020
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 19 June 2020 Resolved
Properly label the exterior of the emergency escape hatches located in the aft cabin, aft head, and dry store lockers. 46 CFR 169.745
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2020
Resolved 8 July 2020
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 19 June 2020 Resolved
Install "T" handle on exterior side of escape located on the mess deck. 46 CFR 169.313
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2020
Resolved 8 July 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 June 2020 Resolved
Replace emergency lighting fixture in dry store lockers. 46 CFR 112.01-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2020
Resolved 8 July 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 June 2020 Resolved
Cracks were identified on both sides of the bowsprit sheath collar. Clean up the rust and remove paint from the cracked area for inspection by USCG marine inspectors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2020
Resolved 8 July 2020
Resolution: The cracks were not in a weld, but in the paint between the bowsprit and a wooden sheath collar.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 June 2020 Resolved
Remove stray gasoline fuel hose and filter from emergency generator space, and place in an appropriate location such as the paint locker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2020
Resolved 8 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 June 2020 Resolved
Re-install fan covers or replace fans in the galley and forward berthing area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2020
Resolved 8 July 2020
Resolution: Fans removed from vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 June 2020 Resolved
All fuel tanks must be emptied, opened, and certified as gas-free by a certified marine chemist for internal inspection by USCG marine inspectors at the next dry dock exam.
Action required: 705 - Other - as specified
Due 31 January 2021
Resolved 8 March 2021
Resolution: Inspected by attending MI's.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2018 Resolved
PROVE PROPER OPERATION OF OVERSPEED DEVICE ON GENERATOR PRIME MOVER THAT IS INDEPENDENT OF THE NORMAL OPERATING GOVERNOR AND ADJUSTED SO THAT THE SPEED CANNOT EXCEED THE MAXIMUM RATED SPEED BY MORE THAN 15 PERCENT. 46 CFR 169.601(b) 46 CFR 111.12-1
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2018
Resolved 2 July 2018
Resolution: Operator purchased a new overspeed device for the portside generator. Overspeed trip tested and found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2018 Resolved
VITAL PIPING SYSTEMS MUST MEET THE MATERIAL AND PRESSRE DESIGN REQUIREMENTS OF SUBCHAPTER F. GENERATOR COOLING WATER PIPING FOUND LEAKING IN ENGINE ROOM. 46 CFR 169.640 (a)
Action required: 10 - Deficiency Rectified
Due 2 July 2018
Resolved 28 June 2018
Resolution: Repaired in kind. Verified adequate repairs made.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 June 2018 Resolved
A FIXED EXTINGUISHING SYSTEM MUST BE INSTALLED TO PROTECT ANY VESSEL MACHINERY SPACE. INSTALL AN APPROVED FIXED EXTINGUISHING SYSTEM IN THE AUXILIARY GENERATOR SPACE. VESSEL RESTRICTED FROM USING AUXILARY GENERATOR. 46 CFR 169.564
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2018
Resolved 31 August 2018
Resolution: Installed aprroved FM-200 system in auxiliary generator space.
Lifesaving › Inflatable Liferafts › Servicing
Issued 20 June 2017 Resolved
Have life rafts seviced by the end of September 2017. Issued an extendion on servicing per 46CFR169.837(b)(4)(i).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 22 August 2017
Resolution: Vessel purchased new life rafts.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 20 June 2017 Resolved
Provide emergency placard for E/R escape hatch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 22 August 2017
Resolution: Complete
Sail Rigging › Mast Step › Mast Partners
Issued 5 June 2014 Resolved
Submit repair plan for foremast structure. Plan shall be approved by OCMI piro to commencemnt of repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2014
Resolved 13 June 2014
Resolution: Work completed prior to check ride
Sail Rigging › Mast Step › Mast Partners
Issued 5 June 2014 Resolved
Make proper repairs to the satisfaction of CG Marine inspector prior to conducting underway operations with instructor/student complement.
Action required: 705 - Other - as specified
Due 5 June 2014
Resolved 13 June 2014
Resolution: test ride sat
Sail Rigging › Stays/Shrouds › Terminals/End Fittings
Issued 5 June 2014 Resolved
Provide 3rd party survey report attesting to the material conditon of spars and rigging.
Action required: 705 - Other - as specified
Due 27 June 2014
Resolved 11 July 2014
Resolution: Rcvd report, attached to file. Allowed for extension to obtain report.
Documentation › Certificates/Documents › Stability Letter
Issued 12 June 2012 Resolved
Total persons allowed on exposed waters reduced to 34 persons until completion of MSC review of current stability letter to account for increase in personnel weight.
Action required: 705 - Other - as specified
Resolved 15 March 2013
Electrical › Electric Generation Source (service) › Generator
Issued 12 June 2012 Resolved
Provide proof of proper operation on all alarms and trips on # 1 and # 2 S/S generators.
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 19 June 2012
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 12 June 2012 Resolved
Complete company DAPI Audit.
Action required: 705 - Other - as specified
Due 31 July 2012
Resolved 26 July 2012
Resolution: Completed DAPI Audit with 02 requirements. See Activity #4376600.
Lifesaving › Inflatable Liferafts › Capacity
Issued 25 August 2011 Resolved
Vsl Captain request to sail to Ensenada with only 01 of 03, 25 person life rafts, to facilitate annual servicing during scheduled dry dock period. An 835 was issued authorizing this request with the stipulation that no more than 25 people will sail onboard during either the trip down to Mexico or on the return voyage to San Diego, or at any time between.
Due 30 September 2011
Resolved 27 September 2011
Resolution: Verified installation of 02 of 3 serviced life rafts (sat.)
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 29 July 2011 Resolved
Provide proof that overboard discharge valves for the #4 grey water tank and MSD are secure to prevent discharge of fuel contaminated fluids from the #4 F/O tank.
Action required: 705 - Other - as specified
Due 30 July 2011
Resolved 30 July 2011
Resolution: Verified the valve was closed and locked.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 29 July 2011 Resolved
Provide proof of permanent repairs to the sewage vacuum pipe in the #4 F/O tank, prior to refilling and usage of the tank. Plans for repairs to be submitted to the local Coast Guard- Vessel Inspections Department, for review and approval. Shore Side Rep [name withheld] at [phone withheld].
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 27 September 2011
Resolution: See Activity # 4119852 for coments.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 29 July 2011 Resolved
Provide proof that all fluids and residues from the #4 grey water tank and MSD have been properly discharged ashore and proof of tank cleaning prior to reactivation of each tank.
Action required: 705 - Other - as specified
Due 30 July 2011
Resolved 30 July 2011
Resolution: MSD and #4 Grey water tank pumped out power washed by NRC Environmental Services.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 29 July 2011 Resolved
Provided proof that all remaining grey and black water (sewage) tanks are not contaminated, prior to allowing overboard discharge.
Action required: 705 - Other - as specified
Due 30 July 2011
Resolved 30 July 2011
Resolution: All grey and black water (sewage) tanks pumped out and power washed by NRC Environmental Services.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 29 July 2011 Resolved
Provide repair proposal to make #4 F/O tank and fore & aft bulkheads watertight.
Action required: 705 - Other - as specified
Due 29 July 2011
Resolved 30 July 2011
Resolution: Bulkhead penetrations returned to original condition and manhole cover reinstalled.
Lifesaving › Inflatable Liferafts › Servicing
Issued 2 September 2004 Resolved
Service and install inflatable liferafts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2004
Resolution: Witnessed service certs for ILR''s
Engineering › Fuel Oil Service System › Valve
Issued 28 August 2003 Resolved
Prove proper operation of emergency fuel shut off valves. (valve doesn't close fully)
Condition: Design Flaw
Due 12 September 2003
Resolved 8 October 2003
Resolution: Cable brace repositioned. Valve operates satisfactorily.
Lifesaving
Issued 26 July 2001 Resolved
PROVIDE 4 CHILD LIFEJACKETS.
Condition: Unknown
Due 2 August 2001
Resolved 27 August 2001
Navigation
Issued 26 July 2001 Resolved
PROVIDE LABELS FOR NORMALLY OPEN VALVS AND 'BY PASS' VALVE FOR STEERING GEAR.
Condition: Unknown
Due 2 August 2001
Resolved 27 August 2001
Fire Fighting
Issued 26 July 2001 Resolved
POST OPERATING INSTRUCTIONS FOR E/R CO2 SYSTEM IN CONTROL ROOM.
Condition: Unknown
Due 2 August 2001
Resolved 27 August 2001
Operations/Management
Issued 26 July 2001 Resolved
Provide an operating plan per 46 CFR 169.218(b)(2). LEGACY COMPONENT DESC: operating plan
Condition: Unknown
Due 26 September 2001
Resolved 7 December 2001
Construction/Loadline › Hull
Issued 26 July 2001 Resolved
Upon recieving loadline assignment, properly mark hull. LEGACY COMPONENT DESC: loadline
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 11 February 2002

Casualty record · 2

23 June 2007Routine · role: Involved in a Marine Casualty · activity 3007482
27 July 2011Routine · role: Acknowledged Pollution Source · activity 4109433
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.