MAURY USCG vessel records
← All vessels

ANN RENEE

Built
1984
Last inspected
5 August 2020
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 5 August 2020
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 6 calendar years (1998–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY2892
233861
Flag
UNITED STATES
Maury page id
psix-233861

Documentation record

Registered dimensions (L × B × D)37.5 ft × 16.0 ft × 6.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRANDY LEE · ORANGE, TX, UNITED STATES · built 1984
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portJACKSONVILLE, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 8 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 14 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

5 August 2020 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7024460
9 July 2013 Deficiency Check · Industry Initiated Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4648093
30 March 2012 Administration
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4275452
2 August 2001 Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1070140
25 November 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 159238
16 November 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 115185
22 June 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 726813
18 June 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 212622
15 April 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 723923
14 April 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 727010
9 April 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 769917
7 April 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 209214
7 April 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 211897
7 April 1998 Uninspected Towing Vessel
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 788970

Deficiency record · 13

Engineering › Diesel Engine (propulsion/auxiliary-electric) › Gear/Clutch Starter (air motor)
Issued 7 April 1998 Resolved
INSTALL SAFETY GUARDS ON BOTH MAINS AND GENERATOR.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Engineering › Fuel Oil Service System › Vent Pipe
Issued 7 April 1998 Resolved
INSTALL FLAME SCREENS ON FUEL VENTS.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Lifesaving › Work Vest › Condition
Issued 7 April 1998 Resolved
PLACE GUARDS OVER AFT STEERING AND HYDROLIC LINES.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Lifesaving › Work Vest › Condition
Issued 7 April 1998 Resolved
INSTALL HANDRAIL ON AFT LADDER.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Lifesaving › Lifejacket/PFD (Type V) › Retroreflective Material
Issued 7 April 1998 Resolved
REPLACE LIFERING ON STBD SIDE. AFFIX RETRO ON PORT LIFERING.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Navigation › Piloting/Steering › Binnacle
Issued 7 April 1998 Resolved
TURN PIN RIGHT SIDE UP AND PUT CARTER PINS IN STEERING ARM PINS.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Lifesaving › Work Vest › Readily Accessible
Issued 7 April 1998 Resolved
TIGHTEN OR REPLACE SHAFT PACKING.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Lifesaving › Work Vest › Readily Accessible
Issued 7 April 1998 Resolved
REMOVE ALL WIRES NOT BEING USED.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 7 April 1998 Resolved
SERVICE ALL FIRE EXTINGUISHES.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Lifesaving › Work Vest › General
Issued 7 April 1998 Resolved
COVER EXPOSED ELECTRICAL WIRING.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Lifesaving › Work Vest › General
Issued 7 April 1998 Resolved
REPLACE MISSING LIGHT COVERS.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Lifesaving › Work Vest › General
Issued 7 April 1998 Resolved
TIGHTEN FUEL LINES ON THE GENERATOR._x001C_
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013
Lifesaving › Work Vest › General
Issued 7 April 1998 Resolved
COVER EXPOSED WIRING ON THE FRESH WATER PUMP.
Condition: Unknown
Due 7 May 1998
Resolved 9 July 2013

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.