MAURY USCG vessel records Sign in
← All vessels

VALHALLA

VALHALLA is a 1984 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1985, most recently in June 2016, along with 110 deficiencies, 2 operational controls and 7 casualty investigations between 2008 and 2012.

Records from 1985 to 2016. Most recent: inspection, 16 June 2016.

Built
1984
Last inspected
16 June 2016
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WRD6087
233981
Flag
UNITED STATES
367408520 (licence lapsed)
Maury page id
psix-233981

Inspections, by type

…with no type recorded17
Years with a record 29 calendar years (1985–2016)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)120.0 ft × 25.0 ft × 5.8 ft
Registered tonnagegross 99 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderH E WILMUNDER DBA WENTCO · RANCHO CORDOVA, CA, UNITED STATES · built 1984
Hull materialSteel
PropulsionSteam Reciprocating
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 20 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
169 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE8699MMSI 367408520 · expired · compulsorily equipped · granted 7 May 2009, cancelled 13 July 2019
WRD6087MMSI not assigned · expired · compulsorily equipped · granted 28 February 1994, cancelled 11 April 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 74

16 June 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5900643
6 June 2012 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4335857
5 June 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4335793
10 January 2012 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4222495
6 January 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4222996
6 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203264
1 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4201719
6 December 2010 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3919520
12 February 2010 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3677148
1 July 2009 Excursion Permit
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3520409
5 February 2009 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3415099
26 November 2008 Examination of Repairs
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3372324
12 September 2008 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3323576
9 September 2008 Damage Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3321355
9 September 2008 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3326172
8 July 2008 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3261530
13 June 2008 COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3235820
30 May 2008 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3276995
14 May 2008 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3206652
27 March 2007 Deadweight Survey · Construction Oversight · Inclining Experiment · Permit to Proceed
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2896002
24 January 2007 Deficiency Check · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2861118
24 April 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2632402
19 October 2005 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2487620
25 February 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2013234
9 February 2004 Deficiency Check · In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1994161
28 August 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1867777
1 July 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1639841
9 May 2002 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1613472
31 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 773082
20 September 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1074241
30 August 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387158
16 August 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1071968
17 April 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1420495
3 May 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1361453
5 May 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1434867
3 November 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 803630
20 June 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 220479
6 May 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1402657
4 March 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 783974
13 May 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1383553
9 May 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1383238
18 April 1996 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1360482
29 September 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 146038
9 June 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 4249
7 June 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 876085
11 May 1995 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 903482
5 March 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1390224
23 June 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1331497
18 May 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1170536
11 May 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 859600
8 May 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 166730
9 July 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1153940
10 June 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1356317
12 May 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 833534
28 May 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1268209
13 May 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1268501
14 May 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 909093
18 March 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 921937
5 February 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 910300
31 May 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1237502
7 September 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1038050
2 August 1989 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1339506
10 August 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1037023
12 November 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1330097
7 October 1987 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012698
12 August 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1337834
12 January 1987 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1005132
22 August 1986 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 988731
1 April 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 996860
13 February 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1295540
3 October 1985 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 992565
20 September 1985 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1297618
22 August 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1292977
22 August 1985 Initial Certification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1294754

Deficiency record · 110

Engineering › Steam Boiler (propulsion) › Piping
Issued 6 June 2012 Resolved
Vessel owner reports loss of starboard propulsion boiler. Troubleshooting commenced 05 June 2012.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2012
Resolution: Repairs effected, cleared no-sail CG-835.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 January 2012 Resolved
Clean all oil and oily waste from engine room, to the satisfaction of the attending Coast Guard marine inspector, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2012
Resolution: Crew cleaned all standing oil out of the engine room.
Engineering › Generator (propulsion-electric) › Wiring
Issued 10 January 2012 Resolved
Identify cause of recent generator failure and make satisfactory repairs prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2012
Resolution: Vessel proposed use of Detroit generator in lieu of Fairbanks generator. OCMI approved this proposal with the conditon that the Fairbanks generator be locked out/tagged out and all fluids drained.
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 February 2010 Resolved
Prove proper full penetration weld on through-hull fittings IAW 177.300 prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2010
Resolved 18 February 2010
Resolution: All through-hull penetrations were properly welded.
Construction/Loadline › Penetrations › Weld
Issued 12 February 2010 Resolved
Firemain sea chest was installed improperly. Prove full penetration weld on aft, starboard sea chest IAW 177.300 prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 March 2010
Resolved 18 February 2010
Resolution: Sea chest properly welded in accordance with weld specifications.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 February 2010 Resolved
Steam condenser cooling pump piping was originally installed with a seamed pipe that is leaking. Prove proper installation of piping system IAW 182.220 prior to carrying passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 March 2010
Resolved 18 February 2010
Resolution: Moved steam conderser cooling pump to a different location that allows for a shortened pipe suction. Installed new electrical wire, a sea chest, and piping IAW applicable regulations.
Engineering › Steering Gear System › Linkage
Issued 12 February 2010 Resolved
Fix broken keyway on helm steering shaft in forward dressing room IAW 46 CFR 115.814.
Due 12 February 2010
Resolved 12 February 2010
Resolution: Visited vessel in drydock and observed functional test of steering system.
Engineering › Thrusters › Shaft
Issued 9 September 2008 Resolved
Make permanent repairs to vessels main propulsion wheel. Submit repair proposal and findings as to cause of failure to the Coast Guard. Repairs will be to the satisfaction of the Attending Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2008
Resolved 16 June 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 13 June 2008 Resolved
Vessel could not provide current FCC Station License.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 16 June 2009
Resolution: Received
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 June 2008 Resolved
Provide operational magnetic compass with calibration record.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 12 September 2008
Engineering › Steam Boiler (propulsion) › Valve, Relief
Issued 13 June 2008 Resolved
Relief Valves must be tested to prove relief at calibrated pressures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 8 July 2008
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 13 June 2008 Resolved
Prove proper operation of all Ship Service Generator overcurrent / overspeed devices.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 July 2008
Resolved 12 September 2008
Engineering › Steam Boiler (propulsion) › Piping
Issued 27 March 2007 Resolved
Attach steam piping to support brackets in upper engine room
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 September 2007
Resolved 27 September 2007
Construction/Loadline › Hull › Side Shell
Issued 4 January 2007 Resolved
Deep pitting and wastage in Sea Chest, ascertain original Scantlings to calculate wastage and pitting. Proposed crop and renew chest.
Condition: Improper/Lack of Maintenance
Due 31 January 2007
Resolved 18 January 2007
Resolution: Completed to the satisfaction of the marine inspector.
Construction/Loadline › Hull › Hull Plating
Issued 4 January 2007 Resolved
Provide audio gauging and repair proposal for bow thruster tunnel where wastage has occurred. Recommend complete crop and renew.
Condition: Design Flaw
Due 18 January 2007
Resolved 18 March 2007
Resolution: Completed to the satisfaction of the marine inspector.
Construction/Loadline › Penetrations › Valve Flange
Issued 4 January 2007 Resolved
Wastage in Spool pieces. Blast or otherwise mechanically/hand prep internally ALL spool pieces (5 Active, 1 capped forward) between skin of vessel and first valve flange. Recommend full replacement of pieces.
Condition: Improper/Lack of Maintenance
Due 31 January 2007
Resolved 18 January 2007
Resolution: Completed to the satisfaction of the marine inspector.
Construction/Loadline › Structures › Door
Issued 4 January 2007 Resolved
Watertight Door repairs.. COnduct Chalk test on all watertight doors, report results to USCG.
Condition: Improper/Lack of Maintenance
Due 31 January 2007
Resolved 18 January 2007
Resolution: Completed to the satisfaction of the marine inspector.
Construction/Loadline › Penetrations › Bottom Plug
Issued 4 January 2007 Resolved
Install Spiget patch on forward penetration that is currently capped off
Due 31 January 2007
Resolved 18 January 2007
Resolution: Completed to the satisfaction of the marine inspector.
Construction/Loadline › Hull › Side Shell
Issued 4 January 2007 Resolved
Crop and renew four tripped flat bar stiffeners under forward sponson
Condition: Damaged By Earlier Event
Due 31 January 2007
Resolved 18 January 2007
Resolution: Completed to the satisfaction of the marine inspector.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 1 May 2006 Resolved
Complete credit Hull Exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 18 January 2007
Resolution: Credit DDX
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 October 2005 Resolved
Provide proof of current Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 October 2005 Resolved
Provide current publications as follows: charts, U.S. Coast Pilot [name withheld] List.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 October 2005 Resolved
Renew to original dry-rotted navigation light wiring electrical cable on port and starboard lights IAW 46 CFR 120.340.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 October 2005 Resolved
Install corrected bulbs in navigation lights IAW 46 CFR 120.420.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Electrical › Electric Generation Source (service) › Conductor
Issued 19 October 2005 Resolved
Install electrical switch plate in way of second forward cabin port side of O2 deck.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Electrical › Electric Generation Source (service) › Conductor
Issued 19 October 2005 Resolved
Complete installation of electrical circuit consisting of outlet, light switch and light fixture in way of aft most cabin port side of O2 deck.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 October 2005 Resolved
Prove proper operation of all emergency lighting IAW 46 CFR 120.432.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Electrical › Electric Generation Source (service) › Panelboard
Issued 19 October 2005 Resolved
Install 2 proper knock-outs in way of electrical panel for air compressor.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 October 2005 Resolved
Renew ring buoy water light and lanyard and attached IAW 46 CFR 117.70(d)(3).
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Electrical › Electric Generation Source (service) › Conductor
Issued 19 October 2005 Resolved
Renew cracked electrical outlet in #2 void.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Construction/Loadline › Structures › Door
Issued 19 October 2005 Resolved
Renew both engine room watertight door gaskets.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 19 October 2005 Resolved
Provide covers for missing fluorescent light covers throughout vessel.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 19 October 2005 Resolved
Provide proof of compliance with mandatory Drug and Alcohol program.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 18 January 2007
Resolution: Cleared for continuity. (Vessel under new ownership)
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 October 2005 Resolved
Provide current training logbook and lifesaving equipment maintenance records.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 18 January 2007
Resolution: Cleared for continuity. (Vessel under new ownership)
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 October 2005 Resolved
Provide protective guard at reversing star of both engines.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 19 October 2005 Resolved
Designate in writing of Senior Deckhead IAW NVIC 1-91.
Action required: 15 - Rectify deficiencies by next port
Due 18 November 2005
Resolved 18 January 2007
Resolution: Cleared for continuity. (Vessel under new ownership)
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 19 October 2005 Resolved
Provide one Type 1 PFD, for adult.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 October 2005 Resolved
Properly label storage of PFD's.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Communications › Alarms/Indicators › General Alarm
Issued 19 October 2005 Resolved
Provide proper operation of ship's horn.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Communications › Internal Communications System › Engine Order Telegraph System
Issued 19 October 2005 Resolved
Prove proper operation of engine order telegraph.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Personnel › Training › First Aid/CPR
Issued 19 October 2005 Resolved
Provide proof that 50% of crew has current CPR/First Aid card.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 18 January 2007
Resolution: Cleared for continuity. (Vessel under new ownership)
Operations/Management › Passenger Operations › Safety Orientation
Issued 19 October 2005 Resolved
Provide signage for max passenger on O3 deck.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 7 December 2005
Engineering › Steam Boiler (propulsion)
Issued 9 February 2004 Resolved
Install correct ASME fasteners in boiler mounts.
Action required: 705 - Other - as specified
Due 11 March 2004
Resolved 11 March 2004
Engineering › Steam Boiler (propulsion)
Issued 9 February 2004 Resolved
Renew lower blow down valves
Action required: 705 - Other - as specified
Due 4 March 2004
Resolved 11 March 2004
Fire Fighting › Combustible Materials
Issued 28 August 2003 Resolved
Remove galley charcoal grill from vessel. LEGACY COMPONENT DESC: Furniture/Furnishings
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 9 February 2004
Electrical › Electrical Distribution System (service)
Issued 28 August 2003 Resolved
Label circuit breakers in the E panel in galley. LEGACY COMPONENT DESC: Circuit Breaker
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 9 February 2004
Engineering › Steam Boiler (propulsion)
Issued 28 August 2003 Resolved
Renew or repair main steam pressure relief valve on stbd boiler and prove proper operation. LEGACY COMPONENT DESC: Valve, Relief
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 9 February 2004
Engineering › Diesel Engine (auxiliary)
Issued 28 August 2003 Resolved
Provide proof of operation of the over speed motor for #2 ship service generator. LEGACY COMPONENT DESC: Overspeed Device
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 9 February 2004
Operations/Management › Pollution
Issued 14 August 2003 Resolved
Remove oil from engine room and condensor space bilges. LEGACY COMPONENT DESC: Retention of Oily Mixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 9 February 2004
Fire Fighting › Combustible Materials
Issued 14 August 2003 Resolved
Renew oil soaked exhaust blankets on primary SSDG. LEGACY COMPONENT DESC: Insulation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 27 February 2004
Electrical › Electric Supply System (service)
Issued 14 August 2003 Resolved
Provide plan for replacement of starting battery cables. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 9 February 2004
Electrical › Electrical Distribution System (service)
Issued 14 August 2003 Resolved
Label circuit breakers in the C panel on 2nd deck. LEGACY COMPONENT DESC: Circuit Breaker
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 9 February 2004
Lifesaving › Lifejacket/PFD (General)
Issued 14 August 2003 Resolved
Separate child size PFD's from adult PFD's in each stowage space. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 9 February 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 9 May 2002 Resolved
Vessel is restricted to 399 passengers until a new jacket is obtained or a lifejacket is repaired. LEGACY COMPONENT DESC: Number
Due 9 August 2002
Resolved 1 July 2002
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 May 2002 Resolved
Provide a means to better separate adult and child lifejackets in stowage areas.
Due 9 May 2002
Resolved 9 May 2002
Documentation › Manuals/Policy Documentation
Issued 9 May 2002 Resolved
Obtain copies of applicable sections of the Coast Pilot and keep onboard vessel. LEGACY COMPONENT DESC: Coast Pilot
Due 9 May 2002
Resolved 9 May 2002
Documentation › Logs/Records
Issued 9 May 2002 Resolved
Develop and keep onboard a station bill. LEGACY COMPONENT DESC: Station Bill
Due 9 May 2002
Resolved 9 May 2002
Documentation › Markings/Placards
Issued 9 May 2002 Resolved
Post an emergency broadcast placard near the radio on the bridge. LEGACY COMPONENT DESC: Emergency Broadcast Placard
Due 9 May 2002
Resolved 9 May 2002
Fire Fighting
Issued 30 August 2001 Resolved
Provide proof of annual servicing of portable fire extinguishers.
Condition: Unknown
Due 11 September 2001
Resolved 11 September 2001
Documentation
Issued 30 August 2001 Resolved
Post copy of vessel stability letter.
Condition: Unknown
Due 11 September 2001
Resolved 11 September 2001
Documentation
Issued 16 August 2001 Resolved
PRIOR TO CARRYING PASSENGERS, COMPLETE THE FOLLOWING TO THE SATISFACTION OFAN ATTENDING MARINE INSPECTOR: AN INSPECTION FOR CERTIFICATION (COI) REINSPECTION, FIRESIDE AND WATERSIDE INSPECTIONS OF BOTH BOILERS, HYDROSTATIC TESTING OF BOTH BOILERS AND PIPING SYSTEMS.
Condition: Unknown
Due 16 August 2001
Resolved 16 August 2001
Electrical
Issued 11 May 1995 Resolved
Install a proper electrical fixture in the 2nd state room portside.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Engineering
Issued 11 May 1995 Resolved
Demonstrate proper operation of starboard boiler safety valve.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Fire Fighting
Issued 11 May 1994 Resolved
PROPERLY SERVICE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Accommodation/Occupational Safety
Issued 11 May 1994 Resolved
PROPERLY SECURE SANITARY WATER (IN PORT) HOSE IN ENGINEROOM.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Electrical
Issued 11 May 1994 Resolved
DEMONSTRATE PROPER OPERATION OF THE PORT AFT EMERGENCY LIGHT ON MAIN DECK.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Construction/Loadline
Issued 11 May 1994 Resolved
PROPERLY REPAIR CRACKED WELD ON MSD SUPPORT BRACKET (INBOARD).
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Engineering
Issued 11 May 1994 Resolved
PROPERLY OPEN BOILER MOUNTS.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Documentation
Issued 11 May 1994 Resolved
PROVIDE A WRITTEN DRUG TESTING PROGRAM.
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Lifesaving
Issued 11 May 1994 Resolved
PROVIDE ONE ADDITIONAL CHILD PFD FOR A TOTAL OF 41 ABOARD.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Navigation
Issued 12 May 1993 Resolved
TIGHTEN PORT RUDDER BOLTS.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Electrical
Issued 12 May 1993 Resolved
REPLACE THE VALVE HANDLE ON THE EMERGENCY GENERATOR FUEL SHUT OFF VALVE.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 12 May 1993 Resolved
PROVIDE TWO ADDITIONAL ADULT LIFE PRESERVERS FOR A TOTAL OF 408. UNTIL THIS REQUIREMENT IS ACCOMPLISHED VESSEL MAY ONLY CARRY 406 ADULT PERSONS.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Construction/Loadline
Issued 12 May 1993 Resolved
ADJUST WATERTIGHT DOOR BETWEEN FRESH WATER TANK AND FUEL TANK VOIDS, TO THESATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Engineering
Issued 12 May 1993 Resolved
REPLACE INSULATION ON THROTTLE VALVE.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Construction/Loadline
Issued 12 May 1993 Resolved
PLACE A 3/4" CAP ON OLD CIRC. PUMP DISCHARGE OVERBOARD LINE.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Engineering
Issued 12 May 1993 Resolved
PROVIDE MANUFACTURES DATA ON LUBE FINDER LRP-02100-C.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Engineering
Issued 12 May 1993 Resolved
TIGHTEN FUEL OIL BURNER ASSEMBLY SUPPLY LINE STARBOARD BOILER.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Electrical
Issued 12 May 1993 Resolved
REPAIR ELECTRICAL CONDUIT ON COOLING PUMP MOTOR FOR LOAD BANK.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Engineering
Issued 12 May 1993 Resolved
TIGHTEN THE SUPPLY CIRC. VALVE STEM PACKING ON PORTSIDE.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Engineering
Issued 12 May 1993 Resolved
DEMONSTRATE A PROPER HYDROSTATIC PRESSURE TEST AND PROPER OPERATION OF THE PORT BOILER.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 12 May 1993 Resolved
REMOVE SPRAY PAINT CANS FROM VESSEL OR PLACE AN APPROVED PAINT LOCKER ABOARD.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Electrical
Issued 12 May 1993 Resolved
LABEL CIRCUIT BREAKERS IN ELECTRICAL PANEL BEHIND BAR.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Engineering
Issued 12 May 1993 Resolved
RENEW LEAKING PIPE NIPPLE ON STARBOARD BOILER.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Electrical
Issued 12 May 1993 Resolved
DEMONSTRATE PROPER OPERATION OF THE STARBOARD BOILER DECK AFT "E" LIGHT.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 13 May 1992 Resolved
SECURE ALL SODA PRESSURE BOTTLES FROM MOVEMENT.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Construction/Loadline
Issued 13 May 1992 Resolved
PROPERLY MARK ALL WATERTIGHT DOORS WITH "MUST BE CLOSED WHILE UNDERWAY" ON BOTH SIDES OF DOOR.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Fire Fighting
Issued 13 May 1992 Resolved
PROPERLY MARK ALL FIRE HOSE STATIONS.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Documentation
Issued 13 May 1992 Resolved
PROVIDE A COPY OF VESSEL'S DRUG TESTING PROGRAM ABOARD THE VESSEL.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Lifesaving
Issued 2 August 1989 Resolved
PROVIDE WATER TIGHT CONTAINER FOR DISTRESS FLARES AND MARK WITH VESSEL'S NAME.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Fire Fighting
Issued 2 August 1989 Resolved
PROVIDE WEIGHT CERTIFICATES FOR ALL PORTABLE HALON EXTINGUISHERS.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Construction/Loadline
Issued 2 August 1989 Resolved
WELD UNDER DECK SIDE OF MAIN DECK INSERT IN FOREPEAK(PRESENTLY WELDED ONE SIDE ONLY).
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Electrical
Issued 2 August 1989 Resolved
INSTALL PROTECTIVE GUARD FOR SHORE TIE BUSS LOCATED BENEATH BOILER ROOM SWITCHBOARD.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Lifesaving
Issued 2 August 1989 Resolved
PROVIDE DISTRESS FLARES AS PER 46 CFR 180-35 ( 6 ORANGE , 6 RED)
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Accommodation/Occupational Safety
Issued 12 August 1987 Resolved
REMOVE OR REPAIR EXPOSED STUD ON FORWARD MAIN DECK STAIRS.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Electrical
Issued 12 August 1987 Resolved
INSTALL LOW LUBE OIL ALARM ON DIESEL GENERATOR.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Electrical
Issued 12 August 1987 Resolved
INSTALL HIGH WATER TEMP ALARM ON DIESEL GENERATOR.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Electrical
Issued 12 August 1987 Resolved
DOUBLE CLAMP ALL FLEXABLE HOSES ON DIESEL GENERATOR.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Construction/Loadline
Issued 12 August 1987 Resolved
PROPERLY DISPLAY OFFICIAL NR. AND NET TONS ON MAIN BEAM.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Electrical
Issued 12 August 1987 Resolved
INSTALL MISSING GLOBE AND GUARD TO LIGHT FIXTURE IN #2 HOLD.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Engineering
Issued 22 August 1986 Resolved
SUBMIT FOR APPROVAL A AUTOMATION CHECK OFF LIST FOR BOILERS.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Documentation
Issued 22 August 1985 Resolved
PROVIDE ANNUAL ENDORCEMENT TO DOCUMENT PAPERS.
Condition: Unknown
Due 22 August 1985
Resolved 22 August 1985
Construction/Loadline
Issued 22 August 1985 Resolved
DRYDOCK VESSEL WITHIN THIRTY DAYS OF THE ABOVE DATE OR REQUEST AN EXTENTION
Condition: Unknown
Due 22 August 1985
Resolved 22 August 1985
Engineering
Issued 22 August 1985 Resolved
PROVIDE 15 SECOND PURGE ON BOILERS
Condition: Unknown
Due 22 August 1985
Resolved 22 August 1985
Fire Fighting
Issued 22 August 1985 Resolved
PROVIDE FIRE HOSE WITH PROPER UNDERWRITER LABS. ENDORSEMENT OR PROVE IT IS EQUIVALENT.
Condition: Unknown
Due 22 August 1985
Resolved 22 August 1985
Lifesaving
Issued 22 August 1985 Resolved
INSTALL FLOAT FREE PIPES FOR BOYANT APPARATUS.
Condition: Unknown
Due 22 August 1985
Resolved 22 August 1985
Electrical
Issued 22 August 1985 Resolved
PROVIDE PERMINATE WIRE INSTALLATION IN GALLEY AND ACCOMODATION SPACE.
Condition: Unknown
Due 22 August 1985
Resolved 22 August 1985
Unknown
Issued 22 August 1985 Resolved
PROVIDE A SYSTEM FOR OVERSPEED TRIP EMERGENCY GENERATOR SO ENGINE WILL SHUT DOWN A LOT SOONER.
Condition: Unknown
Due 22 August 1985
Resolved 22 August 1985
Unknown
Issued 22 August 1985 Resolved
PROVIDE C.G. APPROVED FUEL OIL HOSE TO EMERGENCY GENERATOR.
Condition: Unknown
Due 22 August 1985
Resolved 22 August 1985
Unknown
Issued 22 August 1985 Resolved
PROVIDE EXHAUST COVERING ON EMERGENCY GENERATOR EXHAUST LINE.
Condition: Unknown
Due 22 August 1985
Resolved 22 August 1985

Casualty record · 7

30 May 2008Routine · role: Involved in a Marine Casualty · activity 3276995
9 September 2008Routine · role: Involved in a Marine Casualty · activity 3326172
24 June 2009Routine · role: Involved in a Marine Casualty · activity 3513954
3 September 2009Routine · role: Involved in a Marine Casualty · activity 3584226
6 January 2012Routine · role: Involved in a Marine Casualty · activity 4222996
5 June 2012Routine · role: Involved in a Marine Casualty · activity 4335793
9 September 2012Routine · role: Involved in a Marine Casualty · activity 4437487
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

ALASKA QUEEN (2008–2009), QUEEN OF SEATTLE (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.