MAURY USCG vessel records Sign in
← All vessels

LOK PRAGATI

LOK PRAGATI is a 1984 freight ship. The Coast Guard has recorded 9 inspections since 1984, most recently in April 2000, along with 32 deficiencies and 1 operational control.

Records from 1984 to 2000. Most recent: inspection, 29 April 2000.

Built
1984
Last inspected
29 April 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7503855 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
234292
Flag
INDIA
—
Maury page id
psix-234292

Inspections, by type

…with no type recorded9
Years with a record 7 calendar years (1984–2000)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10020 - Regulatory (Subpart C or D), Net Ton
16040 - Regulatory (Subpart C or D), Gross Ton
26928 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

29 April 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 277389
17 December 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 424021
1 December 1998 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 423213
16 December 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 398432
23 December 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 385919
2 May 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 366427
2 November 1988 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 326618
13 August 1984 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 297442
3 August 1984 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 297324

Deficiency record · 32

Navigation › Piloting/Steering › Swing Meter
Issued 29 April 2000 Resolved
DEMONSTRATE PROPER OPERATION OF LOCAL CONTROL (STEERING FLAT) OF STARBOARD STEERING PUMP IAW SOLAS II-1/29,30.(ACTUATOR APPEARS TO STICK WHEN MANUALLYOPERATED, BUT NORMAL OPERATION IS SAT.)
Condition: Unknown
Due 29 May 2000
Resolved 14 November 2006
Navigation › Piloting/Steering › Steering Magnetic Compass
Issued 29 April 2000 Resolved
DEMONSTRATE PROPER OPERATION OF STEERING GEAR LOSS OF POWER ALARM ON BRIDGEIAW SOLAS II-1/29.
Condition: Unknown
Due 29 May 2000
Resolved 14 November 2006
Construction/Loadline
Issued 1 December 1998 Resolved
Weathertight doors in aft bulkhead on boat deck are wasted (ILLC 66).
Condition: Unknown
Due 15 January 1999
Resolved 15 January 1999
Lifesaving
Issued 1 December 1998 Resolved
Liferafts have servicing documentation but are in a very poor and wasted condition. Banding installed to hold casing together is wasted and missing on Port and Starboard aft liferafts (Solas 60 Chp III, Reg. 15(g)._x001C_
Condition: Unknown
Due 15 January 1999
Resolved 15 January 1999
Unknown
Issued 1 December 1998 Resolved
Lower deck plating in machinery spaces is loose, unsecure and missing._x001C_ (Solas 74 Reg.1/11)
Condition: Unknown
Due 15 January 1999
Resolved 15 January 1999
Lifesaving
Issued 16 December 1996 Resolved
Replace the missing belt drive covers on the emergency fire pump engine andMSD pump & compressor prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Accommodation/Occupational Safety
Issued 16 December 1996 Resolved
Secure all loose deck plates in the machinery space with screws as needed. Rebuild under supports as needed (such as between the M/E turbo chargers). Complete prior to return to a U. S. port. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Accommodation/Occupational Safety
Issued 16 December 1996 Resolved
Remove the excessive chemicals from about the MSD to an adequate storage space prior to return to a U. S. port. _x001C_ _x001C_ 33 CFR 159
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Fire Fighting
Issued 16 December 1996 Resolved
Remove the paint from the forecastle space and E/R stores and place in the approved paint locker prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 amd II-2/18.7
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Accommodation/Occupational Safety
Issued 16 December 1996 Resolved
Replace the missing door handle on the access door to the port lifeboat deck prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 III/19
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Accommodation/Occupational Safety
Issued 16 December 1996 Resolved
Provide running water in the sinks and toilet in the hospital space prior to return to a U. S. port. _x001C_ _x001C_ ILO 147
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Construction/Loadline
Issued 16 December 1996 Resolved
Repair the handle on the stbd, aft vent to the number 1 cargo hold to allowfor closure prior to return to a U. S. port. _x001C_ _x001C_ ICLL 66 II/19
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Fire Fighting
Issued 16 December 1996 Resolved
Repair the broken valve handle on the fire station aft of the #1 cargo holdprior to departure. _x001C_ _x001C_ SOLAS 60 II/65
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Fire Fighting
Issued 16 December 1996 Resolved
Remove the hooks on all stairway fire doors and maintain in a closed position prior to departure. _x001C_ _x001C_ SOLAS 60 II/54
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Deck/Cargo
Issued 16 December 1996 Resolved
Clean the heavy accumulations of hydraulic oil from about the anchor windlass and the base of forward crane. Identify source of leaks and permanently repair prior to departure. _x001C_ 33 CFR 151.10.b
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Engineering
Issued 16 December 1996 Resolved
Permanently repair the patched piping on the M/E heat exchangers as required prior to departure. _x001C_ _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Electrical
Issued 16 December 1996 Resolved
Replace the burned out lights and missing guards in the emergency fire pumpspace prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/65.b
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Accommodation/Occupational Safety
Issued 16 December 1996 Resolved
Secure the missing deck plates in the emergency fire pump space prior to departure. _x001C_ _x001C_ SOLAS 60 II/65.b
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Electrical
Issued 16 December 1996 Resolved
Replace the 230V ground detector lights with similar wattage bulbs. Determine if any grounds exist and repair prior to return to a U. S. port. _x001C_ SOLAS 60 II/27
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Lifesaving
Issued 16 December 1996 Resolved
Renew the wasted supports under the stbd liferafts prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 III/29
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Accommodation/Occupational Safety
Issued 16 December 1996 Resolved
Renew the wasted sewage lines about the MSD prior to return to a U. S. port. _x001C_ _x001C_ 33 CFR 159
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Accommodation/Occupational Safety
Issued 16 December 1996 Resolved
Repair the wasted deck hand rail in the area about the number 2 cargo hatch(stbd) prior to return to a U. S. port. _x001C_ _x001C_ ICLL 66 II/25
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Lifesaving
Issued 16 December 1996 Resolved
Repair the watertight storage compartments on both lifeboats prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 III/17
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Lifesaving
Issued 16 December 1996 Resolved
Renew the wasted lifeboat canopy (rotted) and supports (wasted) as needed prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 III/17
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Engineering
Issued 16 December 1996 Resolved
Make permanent repairs to the exhaust line for the emergency fire pump engine prior to departure._x001C_ _x001C_ SOLAS 60 II/65.b
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Engineering
Issued 16 December 1996 Resolved
Permanently repair the wasted overhead deck where it is leaking water onto the M/E pump & F/P motor controllers prior to departure. _x001C_ _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Fire Fighting
Issued 16 December 1996 Resolved
Perform a detailed cleaning of the oil accumulations on the E/R oil pumps, generator engines & bilges, steering gear and E/R deck plates. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Construction/Loadline
Issued 16 December 1996 Resolved
Remove the bilge line passing through the watertight door from the steeringgear space and hard pipe the system to the main machinery space. Complete prior to departure. _x001C_ SOLAS 60 II/54
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Navigation
Issued 23 December 1995 Resolved
CALIBRATE MAGNETIC COMPASS ON BRIDGE. (INOPERABLE)
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Lifesaving
Issued 23 December 1995 Resolved
REPLACE 04 BRACKETS THAT ATTACH GRAB RAILS, STARBOARD LIFE BOAT. (BROKEN)_x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Electrical
Issued 23 December 1995 Resolved
PLACE LIGHT COVERS ON LIGHTS IN PAINT LOCKER AND ENGINE ROOM. (MISSING)
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Documentation
Issued 3 August 1984 Resolved
NEW VESSEL. DID NOT HAVE ON BOARD A VALID IOPP CERTIFICATE EQUIVALENCY.
Condition: Unknown
Due 15 August 1984
Resolved 3 August 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.