MAURY USCG vessel records Sign in
← All vessels

SEA BIRD

SEA BIRD is a 1984 freight ship. The Coast Guard has recorded 32 inspections since 1984, most recently in November 2008, along with 32 deficiencies and 3 operational controls.

Records from 1984 to 2008. Most recent: inspection, 3 November 2008.

Built
1984
Last inspected
3 November 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8117328 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
234409
Flag
SOUTH KOREA
—
Maury page id
psix-234409

Inspections, by type

…with no type recorded27
Years with a record 22 calendar years (1984–2008)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it21910 - Convention (Subpart B), Net Ton
35915 - Convention (Subpart B), Gross Ton
63788 - Dead Weight, Ton
75608 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

3 November 2008 MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3349070
2 October 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3069675
26 January 2005 ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2280678
24 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2280665
5 November 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1942855
14 January 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1484683
4 April 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 289434
23 March 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 288126
22 June 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 279384
23 August 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 431813
24 March 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 426858
18 October 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 421661
4 November 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 409358
16 April 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 402433
25 September 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 395419
31 July 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 393678
10 June 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 379064
24 January 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 374273
4 August 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 369387
3 June 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 367633
3 June 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1171858
17 September 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 361021
6 July 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 351789
13 August 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 345241
10 April 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 521217
22 June 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 337817
15 October 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 326136
25 September 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 318669
9 September 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 311322
14 May 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 301924
8 January 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 534412
3 July 1984 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 297419

Deficiency record · 32

Engineering › Bilge Water Management System › Piping
Issued 2 October 2007 Resolved
The supply pipe from the bilge pump to the Oily Water Separator is leaking while bilge pump is running.
Action required: 705 - Other - as specified
Due 9 October 2007
Resolved 8 October 2007
Resolution: Received class report from BV satisfying requirement.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 5 November 2003 Resolved
Vessel's sewage treatment plant is not operating as designed. Opening for the addition of chemical was replaced with a plastic jar and lid. The jar is broken and allowing vapors to escape into the engine room. Make repairs to the origin LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2003
Resolved 26 January 2005
Resolution: A new sewage treatment plant was installed.
Unknown
Issued 23 March 2001 Resolved
OILY WATER SEPERATOR OVERBOARD/BILGE ALARM PANEL INOPERABLE.
Condition: Unknown
Due 22 August 2001
Resolved 22 August 2001
Accommodation/Occupational Safety
Issued 23 March 2001 Resolved
MARINE SANITATION DEVICE IN THE HOSPITAL SPACE DOES NOT PROPERLY FLUSH.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Construction/Loadline
Issued 23 March 2001 Resolved
Starboard side loadline needs to be painted in a contrasting color to the hull.
Condition: Unknown
Due 23 April 2001
Resolved 27 March 2001
Documentation
Issued 22 June 2000 Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE FLAG STATE APPROVAL LETTER OF NON FLAG STATE ISSUED LISENCES.
Condition: Unknown
Due 22 June 2000
Resolved 6 July 2000
Fire Fighting
Issued 23 August 1999 Resolved
POST WRITTEN INSTRUCTIONS FOR OPERATION OF EMERGENCY FIRE PUMP PRIOR TO NEXT U.S. PORT. SOLAS 74 II-2/52 AND II-2/15.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Fire Fighting
Issued 23 August 1999 Resolved
POST WRITTEN INSTRUCTIONS FOR OPERATION OF FIXED FOAM SYSTEM PRIOR TO NEXT U.S. PORT. SOLAS 74 II-2/9
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Fire Fighting
Issued 23 August 1999 Resolved
INSTALL MACHINERY GUARD AT FLYWHEEL OF EMERGENCY FIRE PUMP MOTOR PRIOR TO NEXT U.S. PORT. ILO-147
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Fire Fighting
Issued 23 August 1999 Resolved
INSTALL LOCK BOXES AT EACH EMERGENCY GEAR LOCKER TO MAKE THEM ACCESSIBLE ATALL TIMES. SOLAS 74 II-2/15. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Engineering
Issued 23 August 1999 Resolved
MAKE PERMANENT REPAIR TO LEAKING LINE ON #1 LUBE OIL PURIFIER PRIOR TO NEXTU.S. PORT. SOLAS 74 I/II
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Electrical
Issued 23 August 1999 Resolved
MAKE PERMANENT REPAIR TO LEAKING LINE AT DIESEL GENERATOR COOLER PRIOR TO NEXT U.S. PORT. SOLAS 74 I/II
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Construction/Loadline
Issued 18 October 1998 Resolved
Structural fire integrity of bulkhead seperating main engine room and steering flat is not intact in accordance with SOLAS, CH II-2, Regulation 44, Table 44.1.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Documentation
Issued 18 October 1998 Resolved
Vessel's master unable to provide complete file of survey reports (when classed by Korean Registry); i.e. results of thickness/steel plating, statement of structural work. This is required by SOLAS CH. I, Regulation 10.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Lifesaving
Issued 18 October 1998 Resolved
Embarkation ladder for starboard lifeboat parted in violation of SOLAS Ch. III, Regulation 2, Section 7.
Condition: Unknown
Due 20 October 1998
Resolved 12 November 1998
Lifesaving
Issued 18 October 1998 Resolved
Due to questionable command and control and communications, vessel crew is to perform lifeboat drill using port lifeboat in accordance with SOLAS CH. III, Regulation 18, SEction 3.6 and SOLAS CH II, Section 8.
Condition: Unknown
Due 20 October 1998
Resolved 12 November 1998
Documentation
Issued 18 October 1998 Resolved
According to Bureau Veritas issued class survey records,(vessel recently re-classed) continuous machinery survey was to be put on board no later than October 2, 1998 in accordance with SOLAS Ch. XI, Regulation 2. The Master or Chief Engineer were unable to provide the survey.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Engineering
Issued 31 July 1996 Resolved
The Oil Transfer Procedures are missing cargo information (155.750 a-1) andProcedures for operating the emergency shutdown and means of communication (155.750 a-6)
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Engineering
Issued 31 July 1996 Resolved
All F.O. vent containment on deck have wood plugs, not mechanical plugs as required by 33 CFR 156.120 (o) ref 155.310 b-3.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Accommodation/Occupational Safety
Issued 10 June 1995 Resolved
Have class society make proposal for permanent repairs to sanitary stop- check overboard valve(stbd engine room) and salt water supplu line located under deck, stbd side engineroom-both in way of soft patch. SOLAS II-2 Reg 18 and Ch.II Reg 22
Condition: Unknown
Due 10 June 1996
Resolved 13 June 1995
Electrical
Issued 10 June 1995 Resolved
Repair broken light bulb receptacle in forward stores and replace missing globe and wire guard on fixture above work bench. SOLAS CH II-1, Reg 41.2.1
Condition: Unknown
Due 10 June 1996
Resolved 13 June 1995
Fire Fighting
Issued 10 June 1995 Resolved
Replace fractured coupling on port fire main at forward corner on #2 cargo hold. SOLAS Ch II-2, Reg 4(6).
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Navigation
Issued 3 June 1994 Resolved
REPAIR INOPERATIVE STOP BUTTON ON PORT STEERING PUMP PANEL IN STEERING ROOMAND PROVE OPERATION. TO BE CORRECTED PRIOR TO RETURNING TO NEXT U. S. PORT. SOLAS CH. II-1, PT.C, REG 29.7.3
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Electrical
Issued 3 June 1994 Resolved
REPLACE MISSING GLOBES AND WIRE GUARDS IN OVERHEAD LIGHTING FIXTURE IN FORWARD STORES. TO BE CORRECTED PRIOR TO RETURNING TO NEXT U. S. PORT. SOLAS CH. II-1, REG 41.2.1
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Documentation
Issued 3 June 1994 Resolved
PROVIDE VALID LICENSE FOR IN ACCORDANCE WITH SAFETY MANNING CERTIFICATE. VESSEL NOT TO DEPART FROM CONTINENTAL GRAIN CO. UNTIL COARD GUARD RECEIVE PROOF OF VALIDITY OF MASTER'S LICENSE WHICH EXPIRED 31MAR94. SOLAS CH. 1, PTB, REG 18
Condition: Unknown
Due 3 June 1994
Resolved 8 June 1994
Electrical
Issued 3 June 1994 Resolved
REPLACE BULB IN EXPLOSION PROOF LIGHTING FIXTURE IN PAINT LOCKER AND PROPERLY SECURE FIXTURE. TO BE CORRECTED PRIOR TO RETURNING TO NEXT U. S. PORT. SOLAS CH. II-1, REG 45
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Electrical
Issued 3 June 1994 Resolved
REPLACE BROKEN BULB IN EXPLOSION PROOF LIGHTING FIXTURE IN EMERGENCY BATTERY ROOM AND SECURE FIXTURE. TO BE CORRECTED PRIOR RETURNING TO NEXT U. S. PORT. SOLAS CH. II-1, REG. 45
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Deck/Cargo
Issued 6 July 1992 Resolved
Vessels drains and scuppers were not plugged during the transfer of oil.
Condition: Unknown
Due 7 July 1992
Resolved 7 July 1992
Navigation
Issued 6 July 1992 Resolved
Vessels N.O.S. chart 18720 was not corrected to date.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Documentation
Issued 6 July 1992 Resolved
Vessel did not have a discharge of oil placard posted in each machinery space.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Navigation
Issued 6 July 1992 Resolved
Vessels crew could not operate the emergancy steering gear.
Condition: Unknown
Due 7 July 1992
Resolved 7 July 1992
Documentation
Issued 6 July 1992 Resolved
Vessels oil transfer procedures were not readily available to persons engaged in the transfer of oil.
Condition: Unknown
Due 7 July 1992
Resolved 7 July 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.